期刊文献+
共找到4,590篇文章
< 1 2 230 >
每页显示 20 50 100
A novel intelligent adaptive control of laser-based ground thermal test 被引量:1
1
作者 Gan Zhengtao Yu Gang +4 位作者 Li Shaoxia He Xiuli Chen Ru Zheng Caiyun Ning Weijian 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2016年第4期1018-1026,共9页
Laser heating technology is a type of potential and attractive space heat flux simulation technology, which is characterized by high heating rate, controlled spatial intensity distribution and rapid response. However,... Laser heating technology is a type of potential and attractive space heat flux simulation technology, which is characterized by high heating rate, controlled spatial intensity distribution and rapid response. However, the controlled plant is nonlinear, time-varying and uncertainty when implementing the laser-based heat flux simulation. In this paper, a novel intelligent adaptive controller based on proportion-integration-differentiation (PID) type fuzzy logic is proposed to improve the performance of laser-based ground thermal test. The temperature range of thermal cycles is more than 200 K in many instances. In order to improve the adaptability of controller, output scaling factors are real time adjusted while the thermal test is underway. The initial values of scaling factors are optimized using a stochastic hybrid particle swarm optimization (H-PSO) algorithm. A validating system has been established in the laboratory. The performance of the proposed controller is evaluated through extensive experiments under different operating conditions (reference and load disturbance). The results show that the proposed adaptive controller performs remarkably better compared to the conventional PID (PID) controller and the conventional PID type fuzzy (F-PID) controller considering performance indicators of overshoot, settling time and steady state error for laser-based ground thermal test. It is a reliable tool for effective temperature control of laser-based ground thermal test. (C) 2016 Chinese Society of Aeronautics and Astronautics. Production and hosting by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license. 展开更多
关键词 Adaptive control Fuzzy logic Ground thermal test Laser heating thermal control
原文传递
Virtual Thermal Test System Based on Simulink and Comsol Co-Simulation 被引量:1
2
作者 ZHOU Xingguang LIU Bo +3 位作者 JIANG Gang WANG Zhaoxi LIANG Di LIU Shiling 《Aerospace China》 2022年第3期38-43,共6页
A virtual thermal test system was built through the co-simulation using Simulink and Comsol to realize the complete virtualization of the thermal test.Using the co-simulation technology,comprehensive simulation analys... A virtual thermal test system was built through the co-simulation using Simulink and Comsol to realize the complete virtualization of the thermal test.Using the co-simulation technology,comprehensive simulation analysis of the control system,electric field and thermal field was realized.The data state of each observation point could be directly observed at one time,including the output state information of the power amplifier,the output state information of the heater,and the thermal state information of the test unit.The virtual thermal test system has a predictive and guiding role for engineering thermal tests,and can realize thermal environment simulation beyond the existing thermal environment ground simulation capabilities,providing a basis for the development of future models. 展开更多
关键词 SIMULINK Comsol CO-SIMULATION virtual thermal test system
在线阅读 下载PDF
Thermal test and numerical simulation of cooling stave with internal ribbed tube
3
作者 Xun Xu Li-jun Wu Zhao-kuo Yuan 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2022年第8期1194-1204,共11页
A new type of cooling stave with internal ribbed tube was proposed,and the heat transfer performance of the stave was studied by means of thermal test and numerical simulation.The temperature of cooling stave was moni... A new type of cooling stave with internal ribbed tube was proposed,and the heat transfer performance of the stave was studied by means of thermal test and numerical simulation.The temperature of cooling stave was monitored in the conditions of furnace gas temperature of 200-700 C and cooling water velocity of 0.2-1.0 m/s.The thermal test results show that the internal rib structure can form swirl in the water pipe and improve the cooling capacity of the cooling stave.The higher the furnace temperature or the lower the cooling water flow rate,the more obvious the advantage of the cooling stave with internal ribbed tube.The mathematical model of the cooling stave with internal ribbed tube was established by FLUENT software,and the influence of the internal rib structure parameters on the heat transfer performance of the cooling stave was discussed.It is suggested that the parameters of the internal ribbed tube should be 4 ribs,1 mm in height,5-7 mm in width,and 20-30 mm in lead.In the same common working conditions of the cooling stave,the maximum temperature of the newly designed cooling stave with internal ribbed tube is reduced by 5.6%compared with that of common cooling stave with round tube.The water flow rate in the internal ribbed tube only needs 0.9 m/s to reach the cooling effect of 2 m/s in the common tube cooling stave,which can save 55%of water.In case of water shortage accident of cooling stave,the maximum temperature of the cooling stave with internal ribbed tube is decreased by 22.4%compared with that of common round tube,which can effectively reduce the harm of water shortage and protect the cooling stave. 展开更多
关键词 Cooling stave Internal ribbed tube Heat transfer thermal test Numerical simulation
原文传递
Chang'e 5 Undergoing Thermal Test
4
作者 QI Guangming LI Zhenwei CAI Xiaomao 《Aerospace China》 2017年第1期59-59,共1页
Chang’e 5 probe has entered its critical phase of AIT.Units,except the lander,are undergoing thermal test.The flight model of Chang’e 5 is composed of an orbiter,a return capsule,a lander and an ascent unit.The ther... Chang’e 5 probe has entered its critical phase of AIT.Units,except the lander,are undergoing thermal test.The flight model of Chang’e 5 is composed of an orbiter,a return capsule,a lander and an ascent unit.The thermal tests on the ascent unit,the lander-as- 展开更多
关键词 test Chang’e 5 Undergoing thermal test
在线阅读 下载PDF
Site Test of Thermal Environment of Rammed Earth Construction in Anji County of China
5
作者 马金柱 高璞 《Journal of Landscape Research》 2012年第4期3-9,共7页
The scientific evaluation on heat insulation and preservation capacity of rammed earth construction can provide an effective evidence for its superiority in preserving thermal environment of the construction. By takin... The scientific evaluation on heat insulation and preservation capacity of rammed earth construction can provide an effective evidence for its superiority in preserving thermal environment of the construction. By taking an eco-hotel in Zhejiang Anji County as the research object, 33 test points have been set. The indoor and outdoor air temperature of eco-hotel and the surface temperature of building envelopes had been recorded by using data acquisition instrument, temperature transmitter and other equipments from January 27 to February 2 in 2007. Then, the data of a period had been selected for comparison and analysis and the results had been obtained as follows. In January when the temperature difference between day and night in Anji was not large, without particular thermal insulation measures and equipments, the indoor temperature of eco-hotel fluctuated very little, showing that rammed earth construction was of obvious capacity for heat preservation and insulation, that its heat stability was evident and that it could ensure excellent indoor thermal environment. 展开更多
关键词 Rammed EARTH construction INDOOR thermal ENVIRONMENT SITE test
在线阅读 下载PDF
Investigation on the test method of rupture forces of thermal bonding seams in nonwovens shopping bags
6
作者 王来力 吴雄英 丁雪梅 《产业用纺织品》 北大核心 2009年第11期41-44,共4页
超声波热黏合的非织造布接缝不同于普通机织物和针织物等的车缝接缝。运用正交试验设计方法,对纺粘法PP非织造布购物袋热黏合接缝断裂强力测试中的试样宽度、拉伸速率和隔距三个因素进行优化。试验结果表明,试样宽度对纺粘法PP非织造... 超声波热黏合的非织造布接缝不同于普通机织物和针织物等的车缝接缝。运用正交试验设计方法,对纺粘法PP非织造布购物袋热黏合接缝断裂强力测试中的试样宽度、拉伸速率和隔距三个因素进行优化。试验结果表明,试样宽度对纺粘法PP非织造布热黏合接缝断裂强力的测试结果影响最大,并且接缝的断裂强力随着试样宽度的增加而增加。选用试样宽度为200mm、拉伸速率为50mm/min、隔距为100mm的组合所得出的测试结果能比较真实地反映实际的接缝断裂强力。 展开更多
关键词 非织造布 热黏合接缝 测试方法 正交试验
在线阅读 下载PDF
Thermal Performance Analysis of Plaster Reinforced with Raffia Vinifera Particles for Use as Insulating Materials in Building
7
作者 Etienne Malbila Danielle Manuella Djouego Tagne +3 位作者 Bouto Kossi Imbga Lareba Adelaide Ouedraogo Sié Kam David Yemboini Kader Toguyeni 《Journal of Minerals and Materials Characterization and Engineering》 2024年第2期112-138,共27页
The present study focuses on the formulation of new composite consisting of plaster and raffia vinifera particle (RVP) with the purpose to reducing energy consumption. The aim of this study is to test this new compoun... The present study focuses on the formulation of new composite consisting of plaster and raffia vinifera particle (RVP) with the purpose to reducing energy consumption. The aim of this study is to test this new compound as an insulating eco-material in building in a tropical climate. The composites samples were developed by mixing plaster with raffia vinifera particles (RVP) using three different sizes (1.6 mm, 2.5 mm and 4 mm). The effects of four different RVP incorporations rates (i.e., 0wt%, 5wt%;10wt%;15wt%) on physical, thermal, mechanicals properties of the composites were investigated. In addition, the use of the raffia vinifera particles and plaster based composite material as building envelopes thermal insulation material is studied by the habitable cell thermal behavior instrumentation. The results indicate that the incorporation of raffia vinifera particle leads to improve the new composite physical, mechanical and thermal properties. And the parametric analysis reveals that the sampling rate and the size of raffia vinifera particles are the most decisive factor to impact these properties, and to decreases in the thermal conductivity which leads to an improvement to the thermal resistance and energy savings. The best improvement of plaster composite was obtained at the raffia vinifera particles size between 2.5 and 4.0 mm loading of 5wt% (C95P5R) with a good ratio of thermo-physical-mechanical properties. Additionally, the habitable cell experimental thermal behavior, with the new raffia vinifera particles and plaster-based composite as thermal insulating material for building walls, gives an average damping of 4°C and 5.8°C in the insulated house interior environment respectively for cold and hot cases compared to the outside environment and the uninsulated house interior environment. The current study highlights that this mixture gives the new composite thermal insulation properties applicable in the eco-construction of habitats in tropical environments. 展开更多
关键词 Fibres PLASTER thermal test Mechanical test Insulating Material Indoor Comfort
在线阅读 下载PDF
Thermal fatigue behaviors of SiC power module by Ag sinter joining under harsh thermal shock test 被引量:5
8
作者 Chen Chuantong Zhang Hao +2 位作者 Jiu Jinting Long Xu Suganuma Katsuaki 《China Welding》 CAS 2022年第1期15-21,共7页
The excellent properties of SiC bring new challenges for the device packaging.In this study,the bonding strength,fracture behaviors and microstructural evolution of micron-porous Ag joint were elevated during thermal ... The excellent properties of SiC bring new challenges for the device packaging.In this study,the bonding strength,fracture behaviors and microstructural evolution of micron-porous Ag joint were elevated during thermal cycling(–50 ℃–250 ℃) in SiC/DBC(direct bonding copper) die attachment structure for different time.During harsh thermal shock test,the strength of sintered joint deceased gradually with the increase of cycling number,and the value just was half of the value of as-sintered after 1 000 cycles.Coarsening of Ag grains was observed in micron-porous joint with the structure inhomogeneity and defects increasing,which were the reasons of the strength decease.In addition,it was also found that the fracture behavior of sintered joints was changed from ductile deformation of Ag grain to brittle fracture of crack propagation after 1 000 cycles.This study will add the understanding in the mechanical properties of Ag sinter joining and its applications at high temperature. 展开更多
关键词 power module high-temperature reliability Ag sinter joining low stress structure thermal shock test
在线阅读 下载PDF
Thermal Response Test by Improved Test Rig with Heating or Cooling Soil 被引量:1
9
作者 付文成 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2014年第1期15-20,共6页
An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature differ... An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature difference between the inlet and outlet of test well can keep the heating or cooling rate constant, along with a reduced size of test rig. Among the influencial factors of the line source model, the temperature difference was determined as the most important, which agreed with the test results. When the gravel was taken as the backfill material, the soil thermal conductivities of heating and cooling at the test place were 1.883 W/(m&#183;K) and 1.754 W/(m&#183;K), respectively, and the deviation of TRT between heating and cooling soil was 6.8%. In the case of fine sand, the thermal conductivities of heating and cooling were 1.541 W/(m&#183;K) and 1.486 W/(m&#183;K), respectively, and the corresponding deviation was 6%. It was also concluded that different velocities of water had less influence on TRT than the temperature difference. 展开更多
关键词 ground source heat pump thermal response test thermal conductivity backfill material
在线阅读 下载PDF
Characterization of Failure Mechanisms of Duplex and Graded Thermal Barrier Coatings Exposed to Thermal Shock Test 被引量:1
10
作者 A.F.Waheed and H.M.Soliman(Dept. of Metallurgy, Nuclear Research Center, Atomic Energy Authority, Cairo, Egypt) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1996年第1期35-40,共6页
The beginning of failure of a (ZrO2-7%Y2O3)/(Ni-22%Co-17%Cr-12.5%Al-0.6%Y) duplex andgraded coating systems on lnconel 617 and IN738LC in burner rig tests has been characterized.The test conditions are 40 s heating up... The beginning of failure of a (ZrO2-7%Y2O3)/(Ni-22%Co-17%Cr-12.5%Al-0.6%Y) duplex andgraded coating systems on lnconel 617 and IN738LC in burner rig tests has been characterized.The test conditions are 40 s heating up to 75O℃ substrate temperature followed by 80 s aircooling. Failure is considered at the appearance of the first bright spot during heating period.Stresses due to thermal expansion mismatch strains on cooling are the probable cause of life-limiting in this conditions of testing. 展开更多
关键词 Co MILLER Characterization of Failure Mechanisms of Duplex and Graded thermal Barrier Coatings Exposed to thermal Shock test
在线阅读 下载PDF
A test method for evaluating the thermal environment of underground coal mine refuge alternatives
11
作者 D.S.Yantek L.Yan +2 位作者 N.W.Damiano M.A.Reyes J.R.Srednicki 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第3期343-355,共13页
Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the r... Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment.In 30 CFR 7.504,the maximum allowable apparent temperature(AT)for an occupied RA is specified as 35℃(95°F).Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35℃(95°F)AT limit.For these tests,heat input devices are used to input the metabolic heat of actual miners.A wide variety of test methods,sensors,and heat input devices could be used when conducting such tests.Since 2012,the National Institute for Occupational Safety and Health(NIOSH)has conducted over thirty 96-hour heat/humidity tests on four different RAs.This paper discusses the test equipment and procedures used during these investigations.This information is useful for RA manufacturers conducting RA heat/humidity tests,for other researchers investigating RA heat/humidity buildup,and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge. 展开更多
关键词 REFUGE CHAMBER REFUGE ALTERNATIVE CONFINED space thermal environment test method Temperature
在线阅读 下载PDF
Extended application of the tension test in thermal simulator Thermecmastor-Z
12
作者 ZHANG Ge ZHENG Fang YAO Lei 《Baosteel Technical Research》 CAS 2013年第4期43-47,共5页
With the redesigned jigs for the Thermecmastor-Z thermal simulator,the feasibility of using 3 kinds of Gleeble specimens in the Thermecmastor-Z simulator was investigated. Results show that Gleeble specimens can be us... With the redesigned jigs for the Thermecmastor-Z thermal simulator,the feasibility of using 3 kinds of Gleeble specimens in the Thermecmastor-Z simulator was investigated. Results show that Gleeble specimens can be used in the Thermecmastor-Z simulator. The tension tests in the Gleeble and Thermecmastor-Z simulators produced results with the same trend,which proves that the high temperature ductility of Gleeble specimens can be reflected by the Thermecmastor- Z simulator. In addition,as the Thermecmastor-Z simulator offers a wider heating zone,better cross-section shrinkage and elongation of specimens can be achieved under the same test conditions. 展开更多
关键词 thermal simulation tension test GLEEBLE Thermecmastor-Z
在线阅读 下载PDF
Thermal analysis and tests of W/Cu brazing for primary collimator scraper in CSNS/RCS
13
作者 Jie-Bing Yu Jia-Xin Chen +2 位作者 Ling Kang Jie-Feng Wu Yi-Qing Zou 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第4期19-23,共5页
To the transverse beam collimation system in a rapid cycling synchrotron,an important component is the primary collimator,which improves emittance of the beam halo particles such that the particles outside the predefi... To the transverse beam collimation system in a rapid cycling synchrotron,an important component is the primary collimator,which improves emittance of the beam halo particles such that the particles outside the predefined trajectory can be absorbed by the secondary collimators.Given the material properties and power deposition distribution,the beam scraper of the primary collimator is a0.17 mm tungsten foil on a double face-wedged copper block of 121.5 mm x 20 mm.The heat is transferred to the outside by a φ34 mm copper rod.In this paper,for minimizing brazing thermal stress,we report our theoretical analysis and tests on brazing the tungsten and copper materials which differ greatly in size.We show that the thermal stress effect can be controlled effectively by creating stress relief grooves on the copper block and inserting a tungsten transition layer into the copper block.This innovation contributes to the successful R&D of the primary collimator.And this study may be of help for working out a brazing plan of similar structures. 展开更多
关键词 SCRAPER of PRIMARY COLLIMATOR of CSNS/RCS W/Cu BRAZING thermal analysis BRAZING tests
在线阅读 下载PDF
Determination of the Thermal Expansion Coefficient of Concrete at Early Ages by Using Temperature-stress Testing Machine
14
作者 霍凯成 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第4期146-149,共4页
By using the uptodate temperatuer-stress testing machine, the thermal expansion coefficient of concrete at early ages was studied and indicative conclusions were achieved : temperature rising due to hydration heat is... By using the uptodate temperatuer-stress testing machine, the thermal expansion coefficient of concrete at early ages was studied and indicative conclusions were achieved : temperature rising due to hydration heat is not directly correlated with cracking, but the temperature and stress evolation process should be taken into consideration in the same time. Proper chemical admixtures and mineral cornpasitions can improve the mechanical properties of concrete such as thermal expansion coefficient, which is very indicative in practice. 展开更多
关键词 CONCRETE coefficient of thermal expansion temperature-stress test
在线阅读 下载PDF
Thermal Vacuum Test of a Telecommunication Satellite in KM6 Chamber
15
《Aerospace China》 2014年第1期F0003-F0003,共1页
关键词 KM test thermal Vacuum test of a Telecommunication Satellite in KM6 Chamber
在线阅读 下载PDF
Pilot Test Conducted for Thermal Recoveryof Viscous Crude in Baisc Basin
16
《China Oil & Gas》 CAS 1997年第1期38-38,共1页
关键词 test Pilot test Conducted for thermal Recoveryof Viscous Crude in Baisc Basin
在线阅读 下载PDF
Interface fracture toughness and fracture mechanisms of thermal barrier coatings investigated by indentation test and acoustic emission technique 被引量:1
17
作者 Han Jiceng Guo Ping +2 位作者 Luo Jianxia Zhang Zhichao Li Qiang 《China Welding》 EI CAS 2016年第3期63-70,共8页
Interface fracture toughness and fracture mechanisms of plasma-/sprayed thermal barrier coatings (TBCs) were investigated by interfacial indentation test ( HT) in combination with acoustic emission ( AE ) measur... Interface fracture toughness and fracture mechanisms of plasma-/sprayed thermal barrier coatings (TBCs) were investigated by interfacial indentation test ( HT) in combination with acoustic emission ( AE ) measurement. Critical load and AE energy were employed to calculate interface fracture toughness. The critical point at which crack appears at the interface was determined by the HT. AE signals produced during total indentation test not only are used to investigate the interface cracking behavior by Fast Fourier Transform (FFT) and wavelet transforms but also supply the mechanical information. The result shows that the AE signals associated with coating plastic deformation during indentation are of a more continuous type with a lower characteristic frequency content (30 -60 kHz) , whereas the instantaneous relaxation associated with interface crack initiation produces burst type AE signals with a characteristic frequency in the range 70 - 200 kHz. The AE signals energy is concentrated on different scales for the coating plastic deformation, interface crack initiation and interface crack propagation. Interface fracture toughness calculated by AE energy was 1. 19 MPam1/2 close to 1.58 MPam1/2 calculated by critical load. It indicates that the acoustic emission energy is suitable to reflect the interface fracture toughness. 展开更多
关键词 thermal barrier coating acoustic emission interface indentation test interface fracture toughness
在线阅读 下载PDF
基于加热电缆的地源热泵岩土导热系数测试与验证研究 被引量:1
18
作者 关鹏 沈振强 +1 位作者 段新胜 焦玉勇 《太阳能学报》 北大核心 2025年第1期328-334,共7页
岩土导热系数对地源热泵系统的设计和运行有重要影响。获取岩土导热系数的常规热响应试验设备水路电路复杂,存在易受外界干扰、稳定性差、成本高等问题。为解决上述问题,设计一种基于加热电缆的岩土热响应试验仪,以位于武汉市汉阳区的... 岩土导热系数对地源热泵系统的设计和运行有重要影响。获取岩土导热系数的常规热响应试验设备水路电路复杂,存在易受外界干扰、稳定性差、成本高等问题。为解决上述问题,设计一种基于加热电缆的岩土热响应试验仪,以位于武汉市汉阳区的一口地埋管换热孔为研究对象,分别进行常规及加热电缆型热响应和热恢复试验,结合无限长线热源理论和热流叠加原理对各测试阶段的数据进行分析。结果显示加热电缆型热恢复试验精度较高,与常规热响应试验所测岩土导热系数相差仅为0.14 W/(m·K)。研究表明加热电缆型热响应和热恢复试验具有成本低、简单易操作且能获得不同深度地层的岩土导热系数等优势。 展开更多
关键词 地源热泵 导热系数 电加热 热响应试验 热恢复试验 线热源理论
原文传递
Design and experimental performance verification of a thermal property test-bed for lunar drilling exploration 被引量:5
19
作者 Zhang Tao Zhao Zeng +5 位作者 Liu Shuting Li Jinglin Ding Xilun Yin Shen Wang Guoxin Lai Xiaoming 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2016年第5期1455-1468,共14页
Chinese Chang'e lunar exploration project aims to collect and return subsurface lunar soil samples at a minimum penetration depth of 2 m in 2017. However, in contrast to those on the Earth, automated drilling and sam... Chinese Chang'e lunar exploration project aims to collect and return subsurface lunar soil samples at a minimum penetration depth of 2 m in 2017. However, in contrast to those on the Earth, automated drilling and sampling missions on the Moon raise the risk of burning bits. Test-beds are required for testing the thermal properties of drill tools in a lunar environment. In this paper, a novel temperature measuring method based on thermocouples and a slip ring was proposed. Furthermore, a data acquisition system for a drilling process was designed. A vacuous, cryogenic, and anhydrous soil environment simulating the lunar surface was established. A drilling test-bed that can reach a depth of 2.2 m was developed. A control strategy based on online monitoring signals was proposed to improve the drilling performance. Vacuum and non-vacuum experiments were performed to test the temperature rising effect on drill tools. When compared with the non-vacuum experiment, the vacuum temperature rise resulted in a 12 ℃ increase. These experimental results provide significant support for Chinese lunar exploration missions. 展开更多
关键词 Drilling test bed Lunar drill Lunar environment simulator Temperature measurement thermal property
原文传递
真空低温环境下碳泡沫吸波材料电磁性能测试研究
20
作者 杜春林 秦家勇 +1 位作者 王宇辰 申彬 《真空科学与技术学报》 北大核心 2025年第4期326-331,共6页
随着低轨互联网卫星星座的兴起和卫星天线技术的发展,开展热真空环境下卫星与天线联合无线测试成为新的试验模式,以增加测试覆盖性。为此,需要建立一个具备高真空、低温、低微波反射率的综合热试验环境。文章通过分析确定了吸波材料应... 随着低轨互联网卫星星座的兴起和卫星天线技术的发展,开展热真空环境下卫星与天线联合无线测试成为新的试验模式,以增加测试覆盖性。为此,需要建立一个具备高真空、低温、低微波反射率的综合热试验环境。文章通过分析确定了吸波材料应用于真空低温环境下需要关注的关键参数,并给出了参考指标;提出了基于碳泡沫吸波材料的低微波反射率和低无源互调(Passive Intermodulation,PIM)指标的吸波热沉的研制技术流程、测试内容及结果。 展开更多
关键词 热真空试验 碳泡沫 无源互调 吸波热沉
原文传递
上一页 1 2 230 下一页 到第
使用帮助 返回顶部