期刊文献+
共找到109篇文章
< 1 2 6 >
每页显示 20 50 100
Test-retest reliability of the Mini Nutritional Assessment–Short Form(MNA-SF)in older patients undergoing cardiac rehabilitation 被引量:3
1
作者 Fritz Kather Miralem Hadzic +4 位作者 Teresa Hehle Sarah Eichler Julia Klein Heinz Völler Annett Salzwedel 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第9期574-579,共6页
Malnutrition is described as a state of insufficient intake of energy,protein and other nutrients leading to changes in body composition(weight loss,reduced fat-free mass)as well as adverse functional and clinical out... Malnutrition is described as a state of insufficient intake of energy,protein and other nutrients leading to changes in body composition(weight loss,reduced fat-free mass)as well as adverse functional and clinical outcomes.[1]Depending on the assessments and definition used,the prevalence in older patients ranges between 12%in communitydwelling adults to 60%of patients in geriatric care facilities.[2–5]Older populations are at high risk of nutritional deficiencies because of risk factors such as multimorbidity,polypharmacy,cognitive and physical decline,poor appetite,depressive syndromes and socioeconomic changes.[4,6]. 展开更多
关键词 Cardiac rehabilitation MALNUTRITION OCTOGENARIANS test-retest reliability
暂未订购
Aging effect and test-retest reliability of the sinusoidal harmonic acceleration test and velocity step test using nanotorque rotatory chair 被引量:1
2
作者 Nourhan Ghoraba Samir Assal Doaa Elmoazen 《Journal of Otology》 CAS CSCD 2023年第3期125-131,共7页
Introduction:Rotatory chair testing has been used to evaluate horizontal canal function.Frequently used tests include sinusoidal harmonic acceleration test(SHAT)and velocity step test(VST).Objectives:Assessment of age... Introduction:Rotatory chair testing has been used to evaluate horizontal canal function.Frequently used tests include sinusoidal harmonic acceleration test(SHAT)and velocity step test(VST).Objectives:Assessment of age effect on the SHAT and VST and assessment of test-retest reliability of the parameters of those two tests.Methods:A prospective study was performed on 100 subjects with no ear or vestibular complaints and normal vestibular evaluation.They were divided into two groups;Group A:below 50 years of age and Group B:50 years of age or above.SHAT was presented at frequencies 0.02,0.04,0.08,0.16,0.32,0.64 Hz with a peak velocity of 60°/s.VST was performed using a maximum velocity of 100°/s with acceleration and deceleration of 200°/s2.Thirty subjects were tested twice to assess reliability.Results:Study participants ranged in age from 20 to 67 years.Regarding group A,the mean age was30.92±7.31 and 55.36±4.61 for group B.No significant differences were found in SHAT parameters between the two groups.As well,there was no significant difference in VST per-rotatory time constant,however,post-rotatory time constant was significantly longer for Group B(P value<0.05).Intraclass correlation coefficient(ICC)values showed moderate to good reliability(ICC 0.5800.818)for SHAT parameters for the lower frequencies and indicated moderate reliability for VST time constant(ICC 0.5090.652).Conclusions:Age has no significant effect on the parameters of SHAT and VST.Test-retest reliability is generally good for both tests. 展开更多
关键词 Rotatory chair testing Sinusoidal harmonic acceleration test Velocity step test Age effect test-retest reliability
暂未订购
Test-Retest Reliability of Functional Magnetic Resonance Imaging Activation for a Vergence Eye Movement Task 被引量:1
3
作者 Cristian Morales Suril Gohel +5 位作者 Xiaobo Li Mitchell Scheiman Bharat B.Biswal Elio M.Santos Chang Yaramothu Tara L.Alvarez 《Neuroscience Bulletin》 SCIE CAS CSCD 2020年第5期506-518,共13页
Vergence eye movements are the inward and outward rotation of the eyes responsible for binocular coordination.While studies have mapped and investigated the neural substrates of vergence,it is not well understood whet... Vergence eye movements are the inward and outward rotation of the eyes responsible for binocular coordination.While studies have mapped and investigated the neural substrates of vergence,it is not well understood whether vergence eye movements evoke the blood oxygen level-dependent signal reliably in separate experimental visits.The test-retest reliability of stimulus-induced vergence eye movement tasks during a functional magnetic resonance imaging(fMRI)experiment is important for future randomized clinical trials(RCTs).In this study,we established region of interest(ROI)masks for the vergence neural circuit.Twenty-seven binocularly normal young adults participated in two functional imaging sessions measured on different days on the same 3 T Siemens scanner.The fMRI experiments used a block design of sustained visual fixation and rest blocks interleaved between task blocks that stimulated eight or four vergence eye movements.The test-retest reliability of task-activation was assessed using the intraclass correlation coefficient(ICC),and that of spatial extent was assessed using the Dice coefficient.Functional activation during the vergence eye movement task of eight movements compared to rest was repeatable within the primary visual cortex(ICC=0.8),parietal eye fields(ICC=0.6),supplementary eye field(ICC=0.5),frontal eye fields(ICC=0.5),and oculomotor vermis(ICC=0.6).The results demonstrate significant test-retest reliability in the ROIs of the vergence neural substrates for functional activation magnitude and spatial extent using the stimulus protocol of a task block stimulating eight vergence eye movements compared to sustained fixation.These ROIs can be used in future longitudinal RCTs to study patient populations with vergence dysfunctions. 展开更多
关键词 Vergence eye movement test-retest reliability Functional MRI Vergence region of interest masks
原文传递
Frequency-Resolved Connectome Hubs and Their Test-Retest Reliability in the Resting Human Brain
4
作者 Lei Wang Xiaodan Chen +3 位作者 Yuehua Xu Miao Cao Xuhong Liao Yong He 《Neuroscience Bulletin》 SCIE CAS CSCD 2022年第5期519-532,共14页
Functional hubs with disproportionately extensive connectivities play a crucial role in global information integration in human brain networks.However,most resting-state functional magnetic resonance imaging(R-fMRI)st... Functional hubs with disproportionately extensive connectivities play a crucial role in global information integration in human brain networks.However,most resting-state functional magnetic resonance imaging(R-fMRI)studies have identified functional hubs by examining spontaneous fluctuations of the blood oxygen level-dependent signal within a typical low-frequency band(e.g.,0.01–0.08 Hz or 0.01–0.1 Hz).Little is known about how the spatial distributions of functional hubs depend on frequency bands of interest.Here,we used repeatedly measured R-fMRI data from 53 healthy young adults and a degree centrality analysis to identify voxelwise frequency-resolved functional hubs and further examined their test-retest reliability across two sessions.We showed that a wide-range frequency band(0.01–0.24 Hz)accessible with a typical sampling rate(fsample=0.5 Hz)could be classified into three frequency bands with distinct patterns,namely,low-frequency(LF,0.01–0.06 Hz),middle-frequency(MF,0.06–0.16 Hz),and high-frequency(HF,0.16–0.24 Hz)bands.The functional hubs were mainly located in the medial and lateral frontal and parietal cortices in the LF band,and in the medial prefrontal cortex,superior temporal gyrus,parahippocampal gyrus,amygdala,and several cerebellar regions in the MF and HF bands.These hub regions exhibited fair to good test-retest reliability,regardless of the frequency band.The presence of the three frequency bands was well replicated using an independent R-fMRI dataset from 45 healthy young adults.Our findings demonstrate reliable frequency-resolved functional connectivity hubs in three categories,thus providing insights into the frequency-specific connectome organization in healthy and disordered brains. 展开更多
关键词 CONNECTOME HUBS FREQUENCY Degree centrality test-retest reliability
原文传递
Test-Retest Reliability, Convergent Validity and Practice Effects of the RBANS in a Memory Clinic Setting: A Pilot Study
5
作者 Yanhong Dong Claire L. Thompson +3 位作者 Shi Huey Joanne Tan Leon Ben Swie Lim Wanshin Pang Christopher Li-Hsian Chen 《Open Journal of Medical Psychology》 2013年第4期11-16,共6页
This pilot study examined the psychometric properties and clinical utility of a brief neuropsychological instrument (Repeatable Battery for the Assessment of Neuropsychological Status (RBANS). The test-retest reliabil... This pilot study examined the psychometric properties and clinical utility of a brief neuropsychological instrument (Repeatable Battery for the Assessment of Neuropsychological Status (RBANS). The test-retest reliability, practice effects and convergent validity of RBANS were examined in participants without objective cognitive impairment. The tests were administered at two time points at approximately a two weeks’ interval, with 30 cognitively intact participants with a mean age of 63.3 ± 5.8 years. Adequate test-retest reliabilities were found for RBANS subtests, index and total scale scores with significant gain scores in immediate memory and visuospatial function. The RBANS showed good convergent validity and the RBANS supplemented with executive and language measures (Colour Trails Test and 30-item modified Boston Naming Test, respectively) demonstrated excellent convergent validity with a formal neuropsychological battery. This pilot study has provided the preliminary evidence of reliability and convergent validity of the RBANS. Additionally, it also provides insight on the practice effects so that clinicians may assess significant changes in RBANS subtests and domain indexes for clinical practice. 展开更多
关键词 RBANS NEUROPSYCHOLOGICAL Tests test-retest Reliability Validity Practice Effect
暂未订购
Test-retest strength reliability of the Electronic Push/Pull Dynamometer (EPPD) in the measurement of the quadriceps and hamstring muscles on a new chair
6
作者 Mikhled F. Maayah Mohammad D. Al-Jarrah +7 位作者 Saad S. El Zahrani Ali H. Alzahrani Emad T. Ahmedv Amr A. Abdel-Aziem Gopichandran Lakshmanan Nabeel A. Almawajdeh Muhsen B. Alsufiany Yaser O. M. Abu Asi 《Open Journal of Internal Medicine》 2012年第2期123-128,共6页
Background: Test-retest strength reliability of the Electronic Push/Pull Dynamometer (EPPD) in the measurement of the extensor and flexor muscles on a new constructed chair. The objective of the study was to assess re... Background: Test-retest strength reliability of the Electronic Push/Pull Dynamometer (EPPD) in the measurement of the extensor and flexor muscles on a new constructed chair. The objective of the study was to assess reliability of Electronic Push/Pull Dynamometer in the measurement of the knee flexion and extension at 90° and 60° on a new constructed chair. The aims of the author: To assess reliability of Electronic Push/Pull Dynamometer in the measurement of the knee flexion and extension at 90° and 60° on a new constructed chair. Design: A test-retest reliability study. Subjects: One hundred healthy students male and female (mean age, 21y). Methods: Maximum isometric strength of the quadriceps and hamstring muscle groups was measured using the EPPD were recorded at 60° and 90° for 3 trials on 2 occasions. Reliability was assessed with the Intraclass correlation coefficient (ICC), mean and standard deviation (SD) of measurements, and smallest real differences were calculated for the maximum and for the mean and work of the 3 repetitions. Results: Mean strength ranged from 50.44 kg for knee flexion to 55.76 kg for knee extension 50.44 kg to 61.98 kg at 90° hip flexion. Test-retest reliability Intraclass correlation coefficients (ICCs) ranged from 0.85 to 0.99. ICCs for test-retest reliability ranged from 0.780 to 0.998. Conclusions: The results of the reliability study indicate that the EPPD in reliable dynamometer to use in determining lower limb muscle force production. It can be used to measure disease progression and to evaluate changes in knee extension and flexion strength at the individual patient level. 展开更多
关键词 Muscle Strength Reliability test-retest Hand-Held DYNAMOMETER ELECTRONIC Pull/Push DYNAMOMETER
暂未订购
Cortical Morphological Networks Difer Between Gyri and Sulci
7
作者 Qingchun Lin Suhui Jin +4 位作者 Guole Yin Junle Li Umer Asgher Shijun Qiu Jinhui Wang 《Neuroscience Bulletin》 2025年第1期46-60,共15页
This study explored how the human cortical folding pattern composed of convex gyri and concave sulci afected single-subject morphological brain networks,which are becoming an important method for studying the human br... This study explored how the human cortical folding pattern composed of convex gyri and concave sulci afected single-subject morphological brain networks,which are becoming an important method for studying the human brain connectome.We found that gyri-gyri networks exhibited higher morphological similarity,lower small-world parameters,and lower long-term test-retest reliability than sulci-sulci networks for cortical thickness-and gyrifcation index-based networks,while opposite patterns were observed for fractal dimension-based networks.Further behavioral association analysis revealed that gyri-gyri networks and connections between gyral and sulcal regions signifcantly explained inter-individual variance in Cognition and Motor domains for fractal dimension-and sulcal depth-based networks.Finally,the clinical application showed that only sulci-sulci networks exhibited morphological similarity reductions in major depressive disorder for cortical thickness-,fractal dimension-,and gyrifcation index-based networks.Taken together,these fndings provide novel insights into the constraint of the cortical folding pattern to the network organization of the human brain. 展开更多
关键词 Morphological connectivity Magnetic resonance imaging test-retest reliability Cortical folding Graph theory
原文传递
羽毛球专项重复冲刺能力(RSA)测试的构建与应用
8
作者 盛怡 陈国涵 +3 位作者 路恒 项晓琰 唐文静 王然 《天津体育学院学报》 北大核心 2025年第2期235-242,共8页
目的:开发一种符合羽毛球专项特征的重复冲刺能力(RSA)测试并评估其重测信度,探讨该测试与羽毛球运动员运动能力之间的相关性以及在区分不同水平运动员方面的应用价值。方法:招募24名男性受试者(入门组8名、熟练组8名和精英组8名),熟练... 目的:开发一种符合羽毛球专项特征的重复冲刺能力(RSA)测试并评估其重测信度,探讨该测试与羽毛球运动员运动能力之间的相关性以及在区分不同水平运动员方面的应用价值。方法:招募24名男性受试者(入门组8名、熟练组8名和精英组8名),熟练组完成2次专项RSA测试,通过最快冲刺时间(FT)、平均冲刺时间(MT)、减量百分数(%Dec)评估测试的重测信度;并通过反向纵跳(CMJ)和Yo-Yo间歇恢复一级有氧能力测试(YYIR1)分析熟练组下肢爆发力和有氧能力与羽毛球专项RSA测试之间的相关性;所有受试者完成1次RSA测试,记录测试中FT、MT、%Dec、平均心率和测试后1 min的血乳酸浓度,通过单因素方差分析不同组别的差异。结果:(1)羽毛球专项RSA测试总体具有较好的重测信度,其中FT(组内相关系数=0.768,P=0.008)、MT(ICC=0.961,P<0.001)具有较好的重测信度,%Dec(ICC=0.702,P=0.021)的重测信度一般;(2)CMJ高度与MT(r=-0.753,P=0.031)、FT(r=-0.734,P=0.038)呈负相关;YYIR1跑动距离与MT(r=-0.718,P=0.045)呈负相关;(3)精英组、熟练组、入门组在FT(F=150.235,η^(2)=0.935)、MT(F=160.111,η^(2)=0.938)、%Dec(F=15.824,η^(2)=0.601)、血乳酸浓度(F=38.729,η^(2)=0.787)方面均存在显著差异(P<0.001)。结论:羽毛球专项RSA测试具有良好的重测信度,并能有效区分不同水平羽毛球运动员的运动能力。建议将羽毛球专项RSA测试作为评估和监控羽毛球运动员体能水平的工具,用于评价运动员能力并区分竞技水平。 展开更多
关键词 羽毛球 重复冲刺测试 重测信度 区分度
在线阅读 下载PDF
无损检验新技术在核电领域应用的要求研究
9
作者 凌礼恭 贾亚鹏 马瀚洋 《核安全》 2025年第3期33-41,共9页
核电机组无损检验工作量逐年增加,新堆型新设备带来更多的检验挑战,行业亟待引入新技术破解难题。应从法规与标准、管理、技术三个层面解决无损检验新技术在核电领域应用的问题。明确无损检验新技术应用的管理范围、归口、适用标准。以... 核电机组无损检验工作量逐年增加,新堆型新设备带来更多的检验挑战,行业亟待引入新技术破解难题。应从法规与标准、管理、技术三个层面解决无损检验新技术在核电领域应用的问题。明确无损检验新技术应用的管理范围、归口、适用标准。以管理办法或者程序的形式引导无损检验新技术应用申请。建立无损检验新技术评定方案和实施程序,通过自评价、审评、实测复验开展评定工作。以一定倍数的技术论证基数范围,由低安全级向高安全级逐步扩大示范应用,在示范反馈、技术迭代和总结评审中推广应用。 展开更多
关键词 无损检验 新技术 自评价 审评 实测复验
在线阅读 下载PDF
海上油田油管内陀螺复测轨迹技术应用与思考
10
作者 陈国宏 吴占民 +3 位作者 龚明 王攀 王凯 倪益民 《石油工业技术监督》 2025年第7期20-24,共5页
海上油田开发为降低综合成本均采用丛式定向井,一个平台最多可布40~60口井,槽口间距一般为1.8 m×2.0 m;井多、槽口间距小易引起定向井测量仪器磁干扰,导致无法获得浅部轨迹精确数据,增加了井眼之间的碰撞风险;尤其在后期调整井或... 海上油田开发为降低综合成本均采用丛式定向井,一个平台最多可布40~60口井,槽口间距一般为1.8 m×2.0 m;井多、槽口间距小易引起定向井测量仪器磁干扰,导致无法获得浅部轨迹精确数据,增加了井眼之间的碰撞风险;尤其在后期调整井或开窗侧钻作业时,为确保作业的安全顺利,需对老井进行上部陀螺复测轨迹。采用常规做法,则需停井后起出井内电泵及生产管柱进行套管内复测轨迹,这无疑将增加作业成本,并严重影响油田的生产任务。为了降低对油田产量和收益的影响,改进工具和工艺,尝试不停产复测轨迹。通过多个油田尝试,采用不动生产管柱陀螺复测轨迹技术既可降低作业成本,也可最大限度降低对油田生产的影响。 展开更多
关键词 丛式井 防碰 油管陀螺复测 不停产复测
在线阅读 下载PDF
量表条目筛选的统计学方法研究 被引量:185
11
作者 郝元涛 孙希凤 +2 位作者 方积乾 吴少敏 朱淑明 《中国卫生统计》 CSCD 北大核心 2004年第4期209-211,共3页
目的 研究量表条目筛选的统计学方法 ,重点考察克朗巴赫系数法和重测系数法的功能。方法 除离散程度法、相关系数法等常用方法外新增克朗巴赫系数法和重测系数法从内部一致性和稳定性角度对老年人生存质量量表条目池中的条目进行筛选... 目的 研究量表条目筛选的统计学方法 ,重点考察克朗巴赫系数法和重测系数法的功能。方法 除离散程度法、相关系数法等常用方法外新增克朗巴赫系数法和重测系数法从内部一致性和稳定性角度对老年人生存质量量表条目池中的条目进行筛选。结果 将多种方法选中的条目保留下来形成世界卫生组织生存质量测定量表的老年人模块 ,克朗巴赫系数法和重测系数法能使内部一致性和稳定性较好的条目入选。结论 以往常用的 4种方法有助于选择代表性、独立性和区分性较好的条目 ,克朗巴赫系数法和重测系数法则从内部一致性和稳定性角度选择较好的条目 ,建议与前4种方法结合起来运用于条目筛选。 展开更多
关键词 量表条目筛选 统计学 生存质量 克朗巴赫系数 重测系数法
暂未订购
渥太华自我伤害调查表中文版信效度研究 被引量:46
12
作者 张芳 程文红 +1 位作者 肖泽萍 刘文敬 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2015年第3期460-464,共5页
目的对渥太华自我伤害调查表中文版的信效度进行评价。方法对163名上海在校学生和20例临床就诊患者应用渥太华自我伤害调查表中文版进行调查,评价该问卷的重测信度和内部一致性信度。结果除抵制非自杀性自伤(NSSI)行为最有效方式中"... 目的对渥太华自我伤害调查表中文版的信效度进行评价。方法对163名上海在校学生和20例临床就诊患者应用渥太华自我伤害调查表中文版进行调查,评价该问卷的重测信度和内部一致性信度。结果除抵制非自杀性自伤(NSSI)行为最有效方式中"做任何可以让双手忙碌起来的事情"条目外,其他所有条目的重测信度系数均在0.400以上,总体重测信度较佳;功能分量表的内部一致性Cronbach'sα系数为0.952,其4个因子的内部一致性Cronbach'sα系数范围为0.637~0.896。因子分析中共提取6个因子,解释总变异的75.0%。结论渥太华自我伤害调查表中文版具有较好的重测信度和结构效度,可用于有关NSSI行为特征和原因等内容的调查。 展开更多
关键词 非自杀性自伤行为 自我伤害调查表 重测信度 效度
暂未订购
Jamar握力器对老年男性的重测信度和测量误差 被引量:14
13
作者 瓮长水 侯惠如 +6 位作者 王娜 闫雅凤 杨微 朱才兴 刘立明 焦伟国 成忠实 《中国康复理论与实践》 CSCD 2010年第1期3-5,共3页
目的分析Jamar握力器在老年人握力测量时的重测信度和测量误差。方法40位老年志愿者,平均年龄(82.2±8.4)岁。接受间隔1周共2次Jamar握力器测量握力。结果组内相关系数为0.99。测量标准误(SEM、SEM%)为1.18~1.69、4.11%~6.41%;个... 目的分析Jamar握力器在老年人握力测量时的重测信度和测量误差。方法40位老年志愿者,平均年龄(82.2±8.4)岁。接受间隔1周共2次Jamar握力器测量握力。结果组内相关系数为0.99。测量标准误(SEM、SEM%)为1.18~1.69、4.11%~6.41%;个案最小真实改善程度值(SRD、SRD%)为3.27~4.68、11.39%~17.75%;Bland-Altman分析显示没有系统误差。结论在老年男性中,Jamar握力器具有良好的重测信度与可接受的测量误差。 展开更多
关键词 老年人 握力 Jamar握力器 重测信度 测量误差
暂未订购
中文版简明疼痛量表在癌症患者中内在一致性和重测信度分析 被引量:49
14
作者 高丽萍 陈典璇 +2 位作者 韩富莲 霍学佳 瓮长水 《军医进修学院学报》 CAS 2010年第10期1009-1011,共3页
目的探讨中文版简明疼痛量表在癌症患者中的内在一致性和重测信度。方法 50例癌症患者参与本研究。在上午和下午由护士各自独立地应用中文版简明疼痛量表对患者进行调查,检验简明疼痛量表的内在一致性和重测信度。结果内在一致性统计分... 目的探讨中文版简明疼痛量表在癌症患者中的内在一致性和重测信度。方法 50例癌症患者参与本研究。在上午和下午由护士各自独立地应用中文版简明疼痛量表对患者进行调查,检验简明疼痛量表的内在一致性和重测信度。结果内在一致性统计分析结果显示,在前后两次调查中简明疼痛量表的Cronbach′sα系数为0.954和0.958。简明疼痛量表的12个项目Cronbach′sα系数范围为0.947-0.961。重测信度统计分析结果显示,简明疼痛量表12个项目的 ICC值范围在0.774-0.89之间。结论中文版简明疼痛量表具有良好的内在一致性和重测信度。 展开更多
关键词 疼痛测定 肿瘤 患者 重测信度
原文传递
老年人生存质量量表条目的初步筛选 被引量:20
15
作者 孙希凤 郝元涛 方积乾 《中国心理卫生杂志》 CSSCI CSCD 北大核心 2004年第7期455-457,454,共4页
目的 :对世界卫生组织生存质量测定量表老年人模块条目池中的条目用 6种方法进行筛选 ,考察克朗巴赫系数法和重测系数法的功能。方法 :利用多阶段抽样的方法收集资料 ,除离散程度法、相关系数法等常用方法外新增克朗巴赫系数法和重测系... 目的 :对世界卫生组织生存质量测定量表老年人模块条目池中的条目用 6种方法进行筛选 ,考察克朗巴赫系数法和重测系数法的功能。方法 :利用多阶段抽样的方法收集资料 ,除离散程度法、相关系数法等常用方法外新增克朗巴赫系数法和重测系数法从内部一致性和稳定性角度筛选条目。结果 :将多种方法选中的条目保留下来形成世界卫生组织生存质量测定量表的老年人模块 ,克朗巴赫系数法和重测系数法能使内部一致性和稳定性较好的条目入选。结论 :以往常用的 4种方法有助于选择代表性、独立性和区分性较好的条目 ,克朗巴赫系数法和重测系数法则从内部一致性和稳定性角度选择较好的条目 ,建议与前 4种方法结合起来运用于条目筛选。 展开更多
关键词 老年人 生存质量 心理测量学 克朗巴赫系数 重测系数法 精神卫生
暂未订购
汉语单音节测听表在北京听力正常人群中的复测信度评估 被引量:10
16
作者 郗昕 赵乌兰 +4 位作者 冀飞 陈艾婷 赵阳 王永华 韩东一 《听力学及言语疾病杂志》 CAS CSCD 北大核心 2009年第2期95-99,共5页
目的评价22张等价的单音节测听表在正常人群中的复测信度,以利于采用该言语测听材料时得出合理可靠的结论。方法招募北京22名18~30岁耳科正常人,在10 dB HLSpeech强度下,以拉丁方实验设计方案,依次进行22张单音节表的识别率测试。间隔6... 目的评价22张等价的单音节测听表在正常人群中的复测信度,以利于采用该言语测听材料时得出合理可靠的结论。方法招募北京22名18~30岁耳科正常人,在10 dB HLSpeech强度下,以拉丁方实验设计方案,依次进行22张单音节表的识别率测试。间隔6~35天,在完全相同的条件下重新进行第二轮次的识别率测试。结果两轮测试的识别率分别为74.0%±12.2%和72.4%±10.3%,经配对t检验显示P=0.000152。逐表汇总两轮测试得分的差值,统计该差值在22名受试者中的标准差为9.3%,转化成95%置信度下的临界差值(crit-ical difference)为18.3%。两轮测试得分的相关系数为0.684。结论正常人使用该套单音节测听表进行有关言语工程的评价研究时,同一受试者前后两次识别率之差只有高于18.3%时,方可认为处置有效。 展开更多
关键词 言语测听 复测信度 单音节
暂未订购
《药品质量抽查检验管理办法》与《药品质量抽查检验管理规定》中检验和复验内容的对比分析 被引量:16
17
作者 刘文 朱炯 +2 位作者 胡骏 王翀 胡增峣 《中国药房》 CAS 北大核心 2020年第14期1665-1670,共6页
目的:为药品抽检工作相关人员理解并执行《药品质量抽查检验管理办法》中的新要求提供参考。方法:对比《药品质量抽查检验管理办法》和《药品质量抽查检验管理规定》中对检验和复验工作的要求,分析修订或新增内容并提出实施建议。结果... 目的:为药品抽检工作相关人员理解并执行《药品质量抽查检验管理办法》中的新要求提供参考。方法:对比《药品质量抽查检验管理办法》和《药品质量抽查检验管理规定》中对检验和复验工作的要求,分析修订或新增内容并提出实施建议。结果与结论:针对药品监管需要,在《药品质量抽查检验管理规定》的基础上,《药品质量抽查检验管理办法》对检验和复验工作的相关要求进行了修订和补充。在对检验工作的要求中,该办法修订了检验项目要求,明确了检验时限要求,新增了检验报告、原始记录、质量管理体系要求以及“严重风险”的定义及报告要求,对检验机构提出了开展探索性研究的要求,并新增了检验机构和检验人员行为要求。在对复验工作的要求中,该办法修订了申请复验应提交的资料,增加了经办人身份证明、时限证明,修订了不得复验的情况,增加了检出为明显可见异物时的处理方式,并新增了复验报告传递要求。建议药品检验工作的相关人员关注上述变更内容,加强检验能力建设,加强检验时间和检验质量管理,重视严重质量风险,积极开展探索性研究,并加强对自身检验行为的规范;严格审核复验资料,重视新修订的不得复验的情形,并应按要求和实际情况全面传递复验报告,积极执行并落实《药品质量抽验管理办法》。 展开更多
关键词 药品质量抽检管理 检验 复验 对比分析
暂未订购
疲劳量表在癌症患者应用中内在一致性和重测信度的研究 被引量:22
18
作者 高丽萍 朱秀勤 +2 位作者 赵红 焦华梅 陈典璇 《解放军护理杂志》 2009年第8期1-3,共3页
目的探讨中文版简明疲劳量表在癌症患者应用中的内在一致性和重测信度。方法50例癌症患者参与本研究。在上午和下午由护士各自独立地应用中文版简明疲劳量表对患者进行调查,以检验简明疲劳量表的内在一致性和重测信度。结果内在一致性... 目的探讨中文版简明疲劳量表在癌症患者应用中的内在一致性和重测信度。方法50例癌症患者参与本研究。在上午和下午由护士各自独立地应用中文版简明疲劳量表对患者进行调查,以检验简明疲劳量表的内在一致性和重测信度。结果内在一致性统计分析结果显示,在前后两次调查中简明疲劳量表的Cronbach’sα系数均为0.944;简明疲劳量表的9个项目Cronbach’sα系数范围为0.929~0.944。重测信度统计分析结果显示,简明疲劳量表9个项目的ICC值范围为0.742~0.869。结论中文版简明疲劳量表具有良好的内在一致性和重测信度,本研究为癌症患者应用中文版简明疲劳量表提供了参考依据。 展开更多
关键词 简易疲劳量表 内在一致性 重测信度 癌症患者
暂未订购
健康成人等张肌力测试的重测信度研究 被引量:6
19
作者 周谋望 杨延砚 +3 位作者 葛杰 姜军 吕铮 陈亚平 《中国康复医学杂志》 CAS CSCD 北大核心 2005年第10期724-727,共4页
目的:研究等张肌力测试系统所测健康成年人股四头肌、腘绳肌等张肌力各项参数的重测信度,为等张肌力测试的临床推广应用提供基础依据。方法:成年人20名,分别对左右侧股四头肌、腘绳肌进行等张肌力测试,1周后在一天内的同一时间由同一施... 目的:研究等张肌力测试系统所测健康成年人股四头肌、腘绳肌等张肌力各项参数的重测信度,为等张肌力测试的临床推广应用提供基础依据。方法:成年人20名,分别对左右侧股四头肌、腘绳肌进行等张肌力测试,1周后在一天内的同一时间由同一施测者进行重复测试。以组内相关系数(intraclasscorrelationcoefficient,ICC)检验重测信度,α≥0.4视为可信。结果:除左侧股四头肌及右侧腘绳肌疲劳系数的ICC<0.4外,其他参数(包括左右侧股四头肌和腘绳肌前后两次向心/离心收缩最大输出功率、平均最大输出功率、最大输出功率所处平均位置、平均输出功率、最大收缩速率、平均最大收缩速率、最大力量、平均最大力量及总功)前后两次测量的ICC均≥0.4。结论:使用等张肌力测试系统进行等张肌力的测试与评价,具有稳定、可靠、易于操作的特点,是徒手肌力检查的数字化补充,在临床推广应用方面有一定的价值。 展开更多
关键词 等张肌力测试 重测信度 股四头肌 胭绳肌
暂未订购
正常成人听皮层磁共振动脉自旋标记灌注成像的可重复性研究 被引量:10
20
作者 娄昕 吴冰 +4 位作者 吴新淮 纵亮 黄点点 王秋菊 马林 《中华耳科学杂志》 CSCD 北大核心 2013年第1期54-58,共5页
目的研究正常成人听皮层磁共振三维动脉自旋标记灌注成像(three dimensional arterial spin labeling,3D ASL)技术的可重复性.方法8例健康成年人在2台同一机型的3.0T磁共振扫描仪上进行了3次全脑3D ASL序列扫描,在1号扫描仪上进行第1... 目的研究正常成人听皮层磁共振三维动脉自旋标记灌注成像(three dimensional arterial spin labeling,3D ASL)技术的可重复性.方法8例健康成年人在2台同一机型的3.0T磁共振扫描仪上进行了3次全脑3D ASL序列扫描,在1号扫描仪上进行第1次和第3次扫描,在2号扫描仪上进行第2次扫描,三次扫描间隔时间均为10~15天.每次扫描两次3D ASL序列,标记延迟时间(post labeling delay time, PLD)分别选择1.5s和2.5s.对3D结构像进行听皮层结构分割,计算脑血流(cerebral blood flow, CBF)图,并提取听皮层CBF值.对于3次测量结果采用组内相关系数(intraclass correlation coefficient, ICC)及Bland-Altman法进行统计分析.结果听皮层CBF值在51~61 ml/min/100g(PLD=1.5s)和43~54 ml/min/100g之间(PLD=2.5s).第1次与第2次扫描结果比较,PLD为1.5s时ICC值为0.50,PLD为2.5s时为0.76;第2次与第3次扫描结果比较,PLD为1.5s时ICC值为0.83,PLD为2.5s时为0.89;第1次与第3次扫描结果比较,PLD为1.5s时ICC值为0.85,PLD为2.5s时为0.88.Bland-Altman图显示PLD为2.5s数据的分布范围比PLD为1.5s有明显的缩小.结论3D-ASL序列可以进行听皮层CBF值测量,PLD较长时测量的可重复性较好,可用于听皮层血流灌注的多中心研究. 展开更多
关键词 动脉自旋标记 可重复性 磁共振成像 听皮层
暂未订购
上一页 1 2 6 下一页 到第
使用帮助 返回顶部