The turbine blades operate under high temperature and high pressure conditions,and when using radiation thermometry,the influence of radiation from surrounding blades leads to measurement errors.To address this issue,...The turbine blades operate under high temperature and high pressure conditions,and when using radiation thermometry,the influence of radiation from surrounding blades leads to measurement errors.To address this issue,this paper develops a three-dimensional discretized dynamic radiation transfer model based on the blade shape of the turbine.The relationship between the radiation angle coefficient of the surrounding blades and the rotation angle of the blade under test is analyzed.The radiation angle coefficient is calculated using the triangular element method,and temperature inversion is performed based on the effective emissivity to compute the measurement error.The results show that under dynamic high temperature conditions,the temperature measurement error caused by reflection at the selected 60%leaf height point varies with the rotation angle,and the maximum reaches 25.58K.The angular coefficient exhibits periodic fluctuations with changes in rotation angle,and the maximum effective emissivity increases as the rotation angle increases.As the blade height increases,the impact of reflected radiation on radiometric temperature measurement errors shows a decreasing trend.This study provides a reference for radiation thermometry in dynamic high-temperature environments.展开更多
With the widespread adoption of ultra-precision machining(UPM)in manufacturing,accurately monitoring the temperature within micro-scale cutting zones has become crucial for ensuring machining quality and tool longevit...With the widespread adoption of ultra-precision machining(UPM)in manufacturing,accurately monitoring the temperature within micro-scale cutting zones has become crucial for ensuring machining quality and tool longevity.This review comprehensively evaluates modern in-process cutting temperature measurement methods,comparing conventional approaches and emerging technologies.Thermal conduction-based and radiation-based measurement paradigms are analyzed in terms of their merits,limitations,and domain-specific applicability,particularly with regard to the unique challenges involving micro-scale cutting zones in UPM.Special emphasis is placed on micro-scale sensor-integrated tools and self-sensing tools that enable real-time thermal monitoring at cutting edges.Furthermore,we explore thermal monitoring and management techniques for atomic and close-to-atomic scale manufacturing(ACSM),as well as the transformative potential of emerging technologies like artificial intelligence(AI),internet of things(IoT),and data fusion for machining temperature measurement.This review may serve as a reference for UPM cutting temperature measurement research,helping foster the development of optimized process control technologies.展开更多
Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This pap...Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This paper proposes an alternative approach of extracting temperature information in real time from the visible light images of the monitoring target using a convolutional neural network(CNN).A mean-square error of<1.119℃was reached in the temperature measurements of low to medium range using the CNN and the visible light images.Imaging angle and imaging distance do not affect the temperature detection using visible optical images by the CNN.Moreover,the CNN has a certain illuminance generalization ability capable of detection temperature information from the images which were collected under different illuminance and were not used for training.Compared to the conventional machine learning algorithms mentioned in the recent literatures,this real-time,contact-free temperature measurement approach that does not require any further image processing operations facilitates temperature monitoring applications in the industrial and civil fields.展开更多
The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic com...The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat.展开更多
A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearin...A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearing inclusions. For constraining the time and depth of hydrocarbon accumulation by the laser in-situ U-Pb isotope age and clumped isotope temperature, there are two key steps:(1) Investigating feature, abundance and distribution patterns of liquid and gaseous hydrocarbon inclusions with optical microscopes.(2) Dating laser in-situ U-Pb isotope age and measuring clumped isotope temperature of the host minerals of hydrocarbon inclusions. These technologies have been applied for studying the stages of hydrocarbon accumulation in the Sinian Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin. By dating the U-Pb isotope age and measuring the temperature of clumped isotope((35)47) of the host minerals of hydrocarbon inclusions in dolomite, three stages of hydrocarbon accumulation were identified:(1) Late Silurian: the first stage of oil accumulation at(416±23) Ma.(2) Late Permian to Early Triassic: the second stage of oil accumulation between(248±27) Ma and(246.3±1.5) Ma.(3) Yanshan to Himalayan period: gas accumulation between(115±69) Ma and(41±10) Ma. The reconstructed hydrocarbon accumulation history of the Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin is highly consistent with the tectonic-burial history, basin thermal history and hydrocarbon generation history, indicating that the new method is a reliable way for reconstructing the hydrocarbon accumulation history.展开更多
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS...A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.展开更多
This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction o...This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.展开更多
We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position...We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry.展开更多
Biochemical reaction in microfluidic chip is sensitive to temperature.Temperature precise control in a small size device requires the temperature measurement with high measurement precision.Traditional temperature mea...Biochemical reaction in microfluidic chip is sensitive to temperature.Temperature precise control in a small size device requires the temperature measurement with high measurement precision.Traditional temperature measurement method usually measures the voltage drop of the thermistor,which is excited by a constant current source.This method requires the constant current source with high precision and stability.The output of the constant current source is influenced by environmental factors,resulting in a larger measurement error.To solve this problem,a proportion method,a two-layer filtering algorithm,and a power management technique were applied to improve the temperature measurement precision.The proportion method can reduce the low frequency fluctuation error.The two-layer filtering algorithm can reduce the high frequency fluctuation error furtherly.The power management technique used can improve the system stability.Through testing the temperature measurement system built,the experimental results show that the fluctuation error can be significantly decreased from 0.5◦C to 0.2◦C.展开更多
Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electron...Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electronic temperature ranges from 0.1keV to 20 keV. The results show that the temperature sensitivities are higher at the electronic temperature less than 5000 eV and the temperature sensitivities will decrease with the increase of electronic temperature.展开更多
In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and i...In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and improved monotonic spectrum emissivity model, the characteristics of radiation temperature measurement area restricted by the measurement coordinates were theoretically analyzed, through the investigations of the temperature and emissivity coordinate axes. Choosing the specific primary spectrum pyrometer as an example in applications, the theoretical area of radiation temperature measurement of this pyrometer was given and it was verified through blackbody experiments. The discussions of this paper will provide the necessary foundation for the theory research development of primary spectrum pyrometry and the realization of technical applications.展开更多
In the phase of the normalized COVID-19 prevention and control,non-contact temperature measurement is one of the most efficient and convenient methods for initial screening of suspected cases.In the year of 2020 in Wu...In the phase of the normalized COVID-19 prevention and control,non-contact temperature measurement is one of the most efficient and convenient methods for initial screening of suspected cases.In the year of 2020 in Wuhan,such non-contact equipment was urgently demanded,standards development in the traditional way cannot satisfy the market needs.So,the research and development of this standard for infrared intelligent body temperature measurement system was carried out in a rapid way.展开更多
Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram....Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.展开更多
This paper addresses some of the problems related to direct surface temperature measurement of a salient pole synchronous generator excitation winding in rotation. Excitation winding temperature is used for determinin...This paper addresses some of the problems related to direct surface temperature measurement of a salient pole synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the contact DS 18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement of the excitation winding surface conducted in the salient pole synchronous generator in the rotation.展开更多
The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key poin...The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key points of design and revamping experience on the site layout,device protection,lance tool,probe container,measuring position control,and system safety were summarized.Furthermore,a valuable reference for the application of automatic temperature measuring and sampling robots in EAF steelmaking plants will be provided.展开更多
Backward Monte Carlo method of the complicated and exact three-dimensional turbine with the spectral emission and reflection characteristics of the turbine blades materials and the spectral absorption and emission cha...Backward Monte Carlo method of the complicated and exact three-dimensional turbine with the spectral emission and reflection characteristics of the turbine blades materials and the spectral absorption and emission characteristics of combustion gas is established.The factors affecting the accuracy of the radiation temperature measurement are analyzed.The results show that reducing the distance from the probe to the target surface can reduce the effect of the environment on the measurement accuracy.Increasing the temperature and emissivity of the target surface can improve the measurement accuracy.The reflection characteristics of the surfaces have little influence on the radiation temperature measurement,so the blades can be considered as diffuse reflectors in order to improve the calculation efficiency.The temperature measurement accuracy decreases rapidly as the temperature of the combustion gas increases.The temperature measurement accuracy decreases with the increase of total gas pressure and H_(2)O concentration.When measuring the temperature of rotating blades,the apparent emissivity of the target surface is inversely proportional to the measurement accuracy.展开更多
The accurate characterization of thermoelectric properties at low temperatures is crucial for the development of high-performance thermoelectric cooling devices. While measurement errors of thermoelectric properties a...The accurate characterization of thermoelectric properties at low temperatures is crucial for the development of high-performance thermoelectric cooling devices. While measurement errors of thermoelectric properties at temperatures above room temperature have been extensively discussed, there is a lack of standard measurement protocols and error analyses for low-temperature transport properties. In this study, we present a measurement system capable of characterizing all three key thermoelectric parameters, i.e., Seebeck coefficient, electrical conductivity, and thermal conductivity, for a single sample across a temperature range of 10 K to 300 K. We investigated six representative commercial Bi_(2)Te_(3)-based samples(three N-type and three P-type). Using an error propagation model, we systematically analyzed the measurement uncertainties of the three intrinsic parameters and the resulting thermoelectric figure of merit. Our findings reveal that measurement uncertainties for both N-type and P-type Bi_(2)Te_(3)-based materials can be effectively maintained below 5% in the temperature range of 40 K to 300 K. However, the uncertainties increase to over 10% at lower temperatures, primarily due to the relatively smaller values of electrical resistivity and Seebeck coefficients in this regime. This work establishes foundational data for Bi_(2)Te_(3)-based thermoelectric materials and provides a framework for broader investigations of advanced low-temperature thermoelectrics.展开更多
In this paper,a series of calibration-free temperature measurement methods based on light-induced thermoelastic spectroscopy(LITES)are proposed for the first time.These techniques utilize the steady-state and transien...In this paper,a series of calibration-free temperature measurement methods based on light-induced thermoelastic spectroscopy(LITES)are proposed for the first time.These techniques utilize the steady-state and transient response characteristics of the quartz tuning fork(QTF),namely,the calibration-free LITES(CF-LITES)and calibration-free heterodyne LITES(CF-H-LITES)methods.Four methods,first harmonic(1f)difference signal to normalize the second harmonic(2f)fundamental signal(method Ⅰ,2f_(fund)/1f_(diff)),1f overtone signal to normalize the 2f fundamental signal(method Ⅱ,2f_(fund)/1f_(over)),1f heterodyne difference signal to normalize the 2f heterodyne fundamental signal(method Ⅲ,2f-H_(fund)/1f-H_(diff)),and 1f heterodyne overtone signal to normalize the 2f heterodyne fundamental signal(method Ⅳ,2f-H_(fund)/1f-H_(over)),for simultaneously detecting 1f and 2f within the frequency response range of the QTF are proposed to achieve calibration-free measurement.A self-designed T-shaped QTF with low fundamental and overtone frequencies was used to increase the energy accumulation time,thereby enhancing the sensor signal level.A 3-stage tube furnace was adopted to verify the performance of these 4 methods.Experimental results showed that the errors for the 4 methods were less than 4%,with a standard deviation below 11℃.Furthermore,the calibration-free method,which employs normalization of the 2f signal with the 1f signal,effectively mitigates the impact of laser beam jitter and power fluctuations on detection performance.A superior performance can be obtained by adopting the CF-H-LITES technique based on method Ⅳ.It not only has excellent detection performance but also reduces the measurement period to 4 s,which is about 5 times faster.This development shows substantial promise for expanding the application of the CF-LITES and CF-H-LITES techniques in harsh environments.展开更多
Traditional cross-correlation algorithms are prone to time-of-flight(TOF)calculation errors under conditions of strong noise interference and complex temperature gradients,resulting in a decline in the accuracy of ult...Traditional cross-correlation algorithms are prone to time-of-flight(TOF)calculation errors under conditions of strong noise interference and complex temperature gradients,resulting in a decline in the accuracy of ultrasonic temperature measurement.To this end,this paper proposes an ultrasonic temperature measurement method that combines YOLOv11 target detection with energy-type weighted cross-correlation algorithm.The YOLOv11 model is utilized to conduct target detection and key area positioning on the ultrasonic signal waveform diagram,automatically identifying characteristic waveforms such as node waves and end face waves,and achieving adaptive extraction of the effective signal interval.Further introduce the energy-based weighted cross-correlation algorithm.Based on the signal energy distribution,the cross-correlation results are weighted and processed to enhance the main wave response and suppress noise interference.Experiments show that the YOLOv11 model has high detection accuracy(Precision=0.987,Recall=0.958,mAP@50=0.988);The proposed method maintains the stability of time delay estimation under strong noise and high temperature(>1200℃),with the average time delay error reduced by approximately 35%to 50%compared to traditional algorithms.This verifies its high robustness and temperature measurement accuracy in complex environments,and it has a promising engineering application prospect.展开更多
The concept of emissivity has been with the scientific and engineering world since Planck formulated his blackbody radiation law more than a century ago.Nevertheless,emissivity is an elusive concept even for ex⁃perts....The concept of emissivity has been with the scientific and engineering world since Planck formulated his blackbody radiation law more than a century ago.Nevertheless,emissivity is an elusive concept even for ex⁃perts.It is a vague and fuzzy concept for the wider community of engineers.The importance of remote sensing of temperature by measuring IR radiation has been recognized in a wide range of industrial,medical,and environ⁃mental uses.One of the major sources of errors in IR radiometry is the emissivity of the surface being measured.In real experiments,emissivity may be influenced by many factors:surface texture,spectral properties,oxida⁃tion,and aging of surfaces.While commercial blackbodies are prevalent,the much-needed grey bodies with a known emissivity,are unavailable.This study describes how to achieve a calibrated and stable emissivity with a blackbody,a perforated screen,and a reliable and linear novel IR thermal sensor,18 dubbed TMOS.The Digital TMOS is now a low-cost commercial product,it requires low power,and it has a small form factor.The method⁃ology is based on two-color measurements,with two different optical filters,with selected wavelengths conform⁃ing to the grey body definition of the use case under study.With a photochemically etched perforated screen,the effective emissivity of the screen is simply the hole density area of the surface area that emits according to the blackbody temperature radiation.The concept is illustrated with ray tracing simulations,which demonstrate the approach.Measured results are reported.展开更多
文摘The turbine blades operate under high temperature and high pressure conditions,and when using radiation thermometry,the influence of radiation from surrounding blades leads to measurement errors.To address this issue,this paper develops a three-dimensional discretized dynamic radiation transfer model based on the blade shape of the turbine.The relationship between the radiation angle coefficient of the surrounding blades and the rotation angle of the blade under test is analyzed.The radiation angle coefficient is calculated using the triangular element method,and temperature inversion is performed based on the effective emissivity to compute the measurement error.The results show that under dynamic high temperature conditions,the temperature measurement error caused by reflection at the selected 60%leaf height point varies with the rotation angle,and the maximum reaches 25.58K.The angular coefficient exhibits periodic fluctuations with changes in rotation angle,and the maximum effective emissivity increases as the rotation angle increases.As the blade height increases,the impact of reflected radiation on radiometric temperature measurement errors shows a decreasing trend.This study provides a reference for radiation thermometry in dynamic high-temperature environments.
基金supported by the National Natural Science Foundation of China(Nos.52425505 and U22A20207)the National Key R&D Program of China(No.2022YFB3403302)the Zhejiang Provincial Key R&D Program of China(No.2023C01056).
文摘With the widespread adoption of ultra-precision machining(UPM)in manufacturing,accurately monitoring the temperature within micro-scale cutting zones has become crucial for ensuring machining quality and tool longevity.This review comprehensively evaluates modern in-process cutting temperature measurement methods,comparing conventional approaches and emerging technologies.Thermal conduction-based and radiation-based measurement paradigms are analyzed in terms of their merits,limitations,and domain-specific applicability,particularly with regard to the unique challenges involving micro-scale cutting zones in UPM.Special emphasis is placed on micro-scale sensor-integrated tools and self-sensing tools that enable real-time thermal monitoring at cutting edges.Furthermore,we explore thermal monitoring and management techniques for atomic and close-to-atomic scale manufacturing(ACSM),as well as the transformative potential of emerging technologies like artificial intelligence(AI),internet of things(IoT),and data fusion for machining temperature measurement.This review may serve as a reference for UPM cutting temperature measurement research,helping foster the development of optimized process control technologies.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.61975072 and 12174173)the Natural Science Foundation of Fujian Province,China (Grant Nos.2022H0023,2022J02047,ZZ2023J20,and 2022G02006)。
文摘Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This paper proposes an alternative approach of extracting temperature information in real time from the visible light images of the monitoring target using a convolutional neural network(CNN).A mean-square error of<1.119℃was reached in the temperature measurements of low to medium range using the CNN and the visible light images.Imaging angle and imaging distance do not affect the temperature detection using visible optical images by the CNN.Moreover,the CNN has a certain illuminance generalization ability capable of detection temperature information from the images which were collected under different illuminance and were not used for training.Compared to the conventional machine learning algorithms mentioned in the recent literatures,this real-time,contact-free temperature measurement approach that does not require any further image processing operations facilitates temperature monitoring applications in the industrial and civil fields.
基金supported by the National Nature Science Foundation of China (Grants 11132011 and 11472288)
文摘The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat.
基金Supported by the China National Science and Technology Major Project(2016ZX05004-002)Basic Research and Strategic Reserve Technology Research Fund of Institutes Directly Under CNPC(2018D-5008-03)PetroChina Science and Technology Project(2019D-5009-16)。
文摘A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearing inclusions. For constraining the time and depth of hydrocarbon accumulation by the laser in-situ U-Pb isotope age and clumped isotope temperature, there are two key steps:(1) Investigating feature, abundance and distribution patterns of liquid and gaseous hydrocarbon inclusions with optical microscopes.(2) Dating laser in-situ U-Pb isotope age and measuring clumped isotope temperature of the host minerals of hydrocarbon inclusions. These technologies have been applied for studying the stages of hydrocarbon accumulation in the Sinian Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin. By dating the U-Pb isotope age and measuring the temperature of clumped isotope((35)47) of the host minerals of hydrocarbon inclusions in dolomite, three stages of hydrocarbon accumulation were identified:(1) Late Silurian: the first stage of oil accumulation at(416±23) Ma.(2) Late Permian to Early Triassic: the second stage of oil accumulation between(248±27) Ma and(246.3±1.5) Ma.(3) Yanshan to Himalayan period: gas accumulation between(115±69) Ma and(41±10) Ma. The reconstructed hydrocarbon accumulation history of the Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin is highly consistent with the tectonic-burial history, basin thermal history and hydrocarbon generation history, indicating that the new method is a reliable way for reconstructing the hydrocarbon accumulation history.
基金supported by the National Natural Science Foundation of China(10772188)
文摘A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.
基金The project supported by the China Aerodynamics Project for Basic Researches(J13.5.2 ZK04)
文摘This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms.
基金supported by the National Natural Science Foundation of China (Grant No. 61703025)。
文摘We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry.
基金the Professional Technical Service Platform of Science and Technology Commission of Shanghai Municipality(No.19DZ2291103)。
文摘Biochemical reaction in microfluidic chip is sensitive to temperature.Temperature precise control in a small size device requires the temperature measurement with high measurement precision.Traditional temperature measurement method usually measures the voltage drop of the thermistor,which is excited by a constant current source.This method requires the constant current source with high precision and stability.The output of the constant current source is influenced by environmental factors,resulting in a larger measurement error.To solve this problem,a proportion method,a two-layer filtering algorithm,and a power management technique were applied to improve the temperature measurement precision.The proportion method can reduce the low frequency fluctuation error.The two-layer filtering algorithm can reduce the high frequency fluctuation error furtherly.The power management technique used can improve the system stability.Through testing the temperature measurement system built,the experimental results show that the fluctuation error can be significantly decreased from 0.5◦C to 0.2◦C.
文摘Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electronic temperature ranges from 0.1keV to 20 keV. The results show that the temperature sensitivities are higher at the electronic temperature less than 5000 eV and the temperature sensitivities will decrease with the increase of electronic temperature.
基金This research was supported by the National Natural Science Foundation of China ( Grant No. 50606033);National High Technology Research and Development Program of China (Grant No. 2007AA04Z178 )
文摘In the research of primary spectrum pyrometry, this paper discussed the definition problem of radiation temperature measurement area based on the measurement coordinates. For the linear spectrum emissivity model and improved monotonic spectrum emissivity model, the characteristics of radiation temperature measurement area restricted by the measurement coordinates were theoretically analyzed, through the investigations of the temperature and emissivity coordinate axes. Choosing the specific primary spectrum pyrometer as an example in applications, the theoretical area of radiation temperature measurement of this pyrometer was given and it was verified through blackbody experiments. The discussions of this paper will provide the necessary foundation for the theory research development of primary spectrum pyrometry and the realization of technical applications.
文摘In the phase of the normalized COVID-19 prevention and control,non-contact temperature measurement is one of the most efficient and convenient methods for initial screening of suspected cases.In the year of 2020 in Wuhan,such non-contact equipment was urgently demanded,standards development in the traditional way cannot satisfy the market needs.So,the research and development of this standard for infrared intelligent body temperature measurement system was carried out in a rapid way.
文摘Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.
文摘This paper addresses some of the problems related to direct surface temperature measurement of a salient pole synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the contact DS 18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement of the excitation winding surface conducted in the salient pole synchronous generator in the rotation.
文摘The function,features,and architecture of a robot that performs automatic temperature measurement and sampling applied on a 150-t AC electric arc furnace(EAF)production line of Baosteel were presented,and the key points of design and revamping experience on the site layout,device protection,lance tool,probe container,measuring position control,and system safety were summarized.Furthermore,a valuable reference for the application of automatic temperature measuring and sampling robots in EAF steelmaking plants will be provided.
基金supported by the Scientific Instrument Developing Project of the Chinese Academy of Sciences(Grant No.YJKYYQ20200016)the National Science and Technology Major Project of China(Grant No.J2019-V-0006-0100)。
文摘Backward Monte Carlo method of the complicated and exact three-dimensional turbine with the spectral emission and reflection characteristics of the turbine blades materials and the spectral absorption and emission characteristics of combustion gas is established.The factors affecting the accuracy of the radiation temperature measurement are analyzed.The results show that reducing the distance from the probe to the target surface can reduce the effect of the environment on the measurement accuracy.Increasing the temperature and emissivity of the target surface can improve the measurement accuracy.The reflection characteristics of the surfaces have little influence on the radiation temperature measurement,so the blades can be considered as diffuse reflectors in order to improve the calculation efficiency.The temperature measurement accuracy decreases rapidly as the temperature of the combustion gas increases.The temperature measurement accuracy decreases with the increase of total gas pressure and H_(2)O concentration.When measuring the temperature of rotating blades,the apparent emissivity of the target surface is inversely proportional to the measurement accuracy.
基金supported by the National Natural Science Foundation of China (Grant No. 52172259)the National Key Research and Development Program of China (Grant Nos. 2021YFA0718700 and 2022YFB3803900)the Fundamental Research Funds for the Inner Mongolia Normal University (Grant No. 2022JBTD008)。
文摘The accurate characterization of thermoelectric properties at low temperatures is crucial for the development of high-performance thermoelectric cooling devices. While measurement errors of thermoelectric properties at temperatures above room temperature have been extensively discussed, there is a lack of standard measurement protocols and error analyses for low-temperature transport properties. In this study, we present a measurement system capable of characterizing all three key thermoelectric parameters, i.e., Seebeck coefficient, electrical conductivity, and thermal conductivity, for a single sample across a temperature range of 10 K to 300 K. We investigated six representative commercial Bi_(2)Te_(3)-based samples(three N-type and three P-type). Using an error propagation model, we systematically analyzed the measurement uncertainties of the three intrinsic parameters and the resulting thermoelectric figure of merit. Our findings reveal that measurement uncertainties for both N-type and P-type Bi_(2)Te_(3)-based materials can be effectively maintained below 5% in the temperature range of 40 K to 300 K. However, the uncertainties increase to over 10% at lower temperatures, primarily due to the relatively smaller values of electrical resistivity and Seebeck coefficients in this regime. This work establishes foundational data for Bi_(2)Te_(3)-based thermoelectric materials and provides a framework for broader investigations of advanced low-temperature thermoelectrics.
基金supported by the National Natural Science Foundation of China(Grant Nos.62335006,62022032,62275065,62405078,and 61875047)the Key Laboratory of Opto-Electronic Information Acquisition and Manipulation(Anhui University),the Ministry of Education(Grant No.OEIAM202202)the Fundamental Research Funds for the Central Universities(Grant No.HIT.OCEF.2023011).
文摘In this paper,a series of calibration-free temperature measurement methods based on light-induced thermoelastic spectroscopy(LITES)are proposed for the first time.These techniques utilize the steady-state and transient response characteristics of the quartz tuning fork(QTF),namely,the calibration-free LITES(CF-LITES)and calibration-free heterodyne LITES(CF-H-LITES)methods.Four methods,first harmonic(1f)difference signal to normalize the second harmonic(2f)fundamental signal(method Ⅰ,2f_(fund)/1f_(diff)),1f overtone signal to normalize the 2f fundamental signal(method Ⅱ,2f_(fund)/1f_(over)),1f heterodyne difference signal to normalize the 2f heterodyne fundamental signal(method Ⅲ,2f-H_(fund)/1f-H_(diff)),and 1f heterodyne overtone signal to normalize the 2f heterodyne fundamental signal(method Ⅳ,2f-H_(fund)/1f-H_(over)),for simultaneously detecting 1f and 2f within the frequency response range of the QTF are proposed to achieve calibration-free measurement.A self-designed T-shaped QTF with low fundamental and overtone frequencies was used to increase the energy accumulation time,thereby enhancing the sensor signal level.A 3-stage tube furnace was adopted to verify the performance of these 4 methods.Experimental results showed that the errors for the 4 methods were less than 4%,with a standard deviation below 11℃.Furthermore,the calibration-free method,which employs normalization of the 2f signal with the 1f signal,effectively mitigates the impact of laser beam jitter and power fluctuations on detection performance.A superior performance can be obtained by adopting the CF-H-LITES technique based on method Ⅳ.It not only has excellent detection performance but also reduces the measurement period to 4 s,which is about 5 times faster.This development shows substantial promise for expanding the application of the CF-LITES and CF-H-LITES techniques in harsh environments.
文摘Traditional cross-correlation algorithms are prone to time-of-flight(TOF)calculation errors under conditions of strong noise interference and complex temperature gradients,resulting in a decline in the accuracy of ultrasonic temperature measurement.To this end,this paper proposes an ultrasonic temperature measurement method that combines YOLOv11 target detection with energy-type weighted cross-correlation algorithm.The YOLOv11 model is utilized to conduct target detection and key area positioning on the ultrasonic signal waveform diagram,automatically identifying characteristic waveforms such as node waves and end face waves,and achieving adaptive extraction of the effective signal interval.Further introduce the energy-based weighted cross-correlation algorithm.Based on the signal energy distribution,the cross-correlation results are weighted and processed to enhance the main wave response and suppress noise interference.Experiments show that the YOLOv11 model has high detection accuracy(Precision=0.987,Recall=0.958,mAP@50=0.988);The proposed method maintains the stability of time delay estimation under strong noise and high temperature(>1200℃),with the average time delay error reduced by approximately 35%to 50%compared to traditional algorithms.This verifies its high robustness and temperature measurement accuracy in complex environments,and it has a promising engineering application prospect.
文摘The concept of emissivity has been with the scientific and engineering world since Planck formulated his blackbody radiation law more than a century ago.Nevertheless,emissivity is an elusive concept even for ex⁃perts.It is a vague and fuzzy concept for the wider community of engineers.The importance of remote sensing of temperature by measuring IR radiation has been recognized in a wide range of industrial,medical,and environ⁃mental uses.One of the major sources of errors in IR radiometry is the emissivity of the surface being measured.In real experiments,emissivity may be influenced by many factors:surface texture,spectral properties,oxida⁃tion,and aging of surfaces.While commercial blackbodies are prevalent,the much-needed grey bodies with a known emissivity,are unavailable.This study describes how to achieve a calibrated and stable emissivity with a blackbody,a perforated screen,and a reliable and linear novel IR thermal sensor,18 dubbed TMOS.The Digital TMOS is now a low-cost commercial product,it requires low power,and it has a small form factor.The method⁃ology is based on two-color measurements,with two different optical filters,with selected wavelengths conform⁃ing to the grey body definition of the use case under study.With a photochemically etched perforated screen,the effective emissivity of the screen is simply the hole density area of the surface area that emits according to the blackbody temperature radiation.The concept is illustrated with ray tracing simulations,which demonstrate the approach.Measured results are reported.