To explore the technical solution for independently-developed wireless synchronous control of locomotives based on 5G-R,this study investigates the service demands of such control and analyzes the insufficiency of the...To explore the technical solution for independently-developed wireless synchronous control of locomotives based on 5G-R,this study investigates the service demands of such control and analyzes the insufficiency of the existing communication system of China's heavy-haul railway.Giving full consideration of the high bandwidth,low delay,IP-based links,packet domain transmission,quality of service priority guarantee and other characteristics of the 5G-R network,an overall technical solution is proposed,focusing on the implementation of functions such as master-slave locomotive data transmission,controllable end-of-train data transmission,marshaling requests,and multi-driver calls.The findings contribute to enhancing the advancement of the independently-developed wireless synchronous control system of locomotives,ensuring its reliable operation in complex environments,providing valuable guidance for improving the safety and efficiency of heavy-haul railway transportation,and offering robust technical support for the modernization and intelligence development of heavy-haul railway.展开更多
The vertical position of plasma in the HT-7U Tokamak is inherently unstable. In order to realize active stabilization, the response rate of the high-power high-frequency amplifier feeding the active control coils must...The vertical position of plasma in the HT-7U Tokamak is inherently unstable. In order to realize active stabilization, the response rate of the high-power high-frequency amplifier feeding the active control coils must be fast enough. This paper analyzes the paralleling scheme of the power amplifier through two kinds of control mode. One is the synchronous control; the other is the asynchronous control. Via the comparison of the two kinds of control mode, both of their characteristics are given in the text. At last, the analyzed result is verified by a small power experiment.展开更多
The increasing adoption of grid-forming converters(GFMCs)stems from their capacity to furnish voltage and frequency support for power grids.Nevertheless,GFMCs employing the current reference saturation limiting method...The increasing adoption of grid-forming converters(GFMCs)stems from their capacity to furnish voltage and frequency support for power grids.Nevertheless,GFMCs employing the current reference saturation limiting method often exhibit instability during various transient disturbances including grid voltage sags,frequency variations,and phase jumps.To address this problem,this paper proposes a virtual power angle synchronous(δv-SYN)control method.The fundamental of this method is to achieve synchronization with the grid using the virtual power angleδv instead of the active power.The transient stability characteristics of the proposed method are theoretically elucidated using a novel virtual power angle-power angle(δv-δ)model.The key benefit of the proposed method is its robustness to various grid strengths and diverse forms of transient disturbances,eliminating the requirement for fault identification or control switching.Moreover,it can offer grid-forming support to the grid during grid faults.Hardware-in-the-loop experimental results validate the theoretical analysis and the performance of the proposed method.展开更多
The brushless doubly-fed induction generator(BDFIG)presents significant potential for application in wind power systems,primarily due to the elimination of slip rings and brushes.The application of virtual synchronous...The brushless doubly-fed induction generator(BDFIG)presents significant potential for application in wind power systems,primarily due to the elimination of slip rings and brushes.The application of virtual synchronous control(VSynC)has been demonstrated to effectively augment the inertia of BDFIG systems.However,the dynamic characteristics and stability of BDFIG under weak grid conditions remain largely unexplored.The critical stabilizing factors for BDFIG-based wind turbines(WTs)are methodically investigated,and an enhanced VSynC method based on linear active disturbance rejection control(LADRC)is proposed.The stability analysis reveals that the proposed method can virtually enhance the stability of the grid-connected system under weak grid conditions.The accuracy of the theoretical analysis and the effectiveness of the proposed method are affirmed through extensive simulations and detailed experiments.展开更多
Dear Editor,This letter proposes a deep synchronization control(DSC) method to synchronize grid-forming converters with power grids. The method involves constructing a novel controller for grid-forming converters base...Dear Editor,This letter proposes a deep synchronization control(DSC) method to synchronize grid-forming converters with power grids. The method involves constructing a novel controller for grid-forming converters based on the stable deep dynamics model. To enhance the performance of the controller, the dynamics model is optimized within the deep reinforcement learning(DRL) framework. Simulation results verify that the proposed method can reduce frequency deviation and improve active power responses.展开更多
This paper explores the issue of secure synchronization control in piecewise-homogeneous Markovian jump delay neural networks affected by denial-of-service(DoS)attacks.Initially,a novel memory-based adaptive event-tri...This paper explores the issue of secure synchronization control in piecewise-homogeneous Markovian jump delay neural networks affected by denial-of-service(DoS)attacks.Initially,a novel memory-based adaptive event-triggered mechanism(MBAETM)is designed based on sequential growth rates,focusing on event-triggered conditions and thresholds.Subsequently,from the perspective of defenders,non-periodic DoS attacks are re-characterized,and a model of irregular DoS attacks with cyclic fluctuations within time series is further introduced to enhance the system's defense capabilities more effectively.Additionally,considering the unified demands of network security and communication efficiency,a resilient memory-based adaptive event-triggered mechanism(RMBAETM)is proposed.A unified Lyapunov-Krasovskii functional is then constructed,incorporating a loop functional to thoroughly consider information at trigger moments.The master-slave system achieves synchronization through the application of linear matrix inequality techniques.Finally,the proposed methods'effectiveness and superiority are confirmed through four numerical simulation examples.展开更多
The rapid development of new energy power generation technology and the transformation of power electronics in the core equipment of source-grid-load drives the power system towards the“double-high”development patte...The rapid development of new energy power generation technology and the transformation of power electronics in the core equipment of source-grid-load drives the power system towards the“double-high”development pattern of“high proportion of renewable energy”and“high proportion of power electronic equipment”.To enhance the transient performance of AC/DC hybrid microgrid(HMG)in the context of“double-high,”aπtype virtual synchronous generator(π-VSG)control strategy is applied to bidirectional interface converter(BIC)to address the issues of lacking inertia and poor disturbance immunity caused by the high penetration rate of power electronic equipment and new energy.Firstly,the virtual synchronous generator mechanical motion equations and virtual capacitance equations are used to introduce the virtual inertia control equations that consider the transient performance of HMG;based on the equations,theπ-type equivalent control model of the BIC is established.Next,the inertia power is actively transferred through the BIC according to the load fluctuation to compensate for the system’s inertia deficit.Secondly,theπ-VSG control utilizes small-signal analysis to investigate howthe fundamental parameters affect the overall stability of the HMG and incorporates power step response curves to reveal the relationship between the control’s virtual parameters and transient performance.Finally,the PSCAD/EMTDC simulation results show that theπ-VSG control effectively improves the immunity of AC frequency and DC voltage in the HMG system under the load fluctuation condition,increases the stability of the HMG system and satisfies the power-sharing control objective between the AC and DC subgrids.展开更多
A synchronous control of relative attitude and position is required in separated ultraquiet spacecraft, such as drag-free, disturbance-free, and distributed spacecraft. Thus, a twistorbased synchronous sliding mode co...A synchronous control of relative attitude and position is required in separated ultraquiet spacecraft, such as drag-free, disturbance-free, and distributed spacecraft. Thus, a twistorbased synchronous sliding mode control is investigated in this paper to solve the control problem of relative attitude and position among separated spacecraft modules. The twistor-based control design and the stability proof are implemented using the Modified Rodrigues Parameter(MRP).To evaluate the effectiveness of the proposed control method, this paper presents a case study of separated spacecraft flying control considering the mass uncertainty and external disturbances. In addition, a simulation study of the Proportional-Derivative(PD) control is also presented for comparison. The results indicate that the twistor-based sliding mode controller can ensure global asymptotic stability. The states converge fast with ultra-precision and ultra-stability in both the attitude and position. Moreover, the proposed twistor-based sliding mode control system is robust to the mass uncertainty and external disturbances.展开更多
Grid-tie voltage source converters(VSCs)can operate in three distinct modes:AC-dominant,DC-dominant,and balanced,depending on the placement of the stiff voltage sources.The distinct operation modes of the VSCs traditi...Grid-tie voltage source converters(VSCs)can operate in three distinct modes:AC-dominant,DC-dominant,and balanced,depending on the placement of the stiff voltage sources.The distinct operation modes of the VSCs traditionally demand different synchronization control techniques,leading to heterogeneous VSCs.It is challenging for the power system to accommodate and coordinate heterogeneous VSCs.A promising universal synchronization control technique for VSCs is the DC-link voltage synchronization control(DVSC)based on a lead compensator(LC).The LC DVSC stabilizes both the DC and AC voltages of a VSC while achieving synchronization with the AC grid.This results in a dual-port grid-forming(DGFM)characteristic for the VSC.However,there has been very limited study on the stability and synchronization controller design of the VSCs with the LC DVSC operating in various modes.To bridge this gap,the paper presents a quantitative analysis on the stability and steady-state performance of the LC DVSC in all three operation modes of the DGFM VSC.Based on the analysis,the paper provides step-by-step design guidelines for the LC DVSC.Furthermore,the paper uncovers an instability issue related to the LC DVSC when the DGFM VSC operates in the balanced mode.To tackle the instability issue,a virtual resistance control is proposed and integrated with the LC DVSC.Simulation results validate the analysis and demonstrate the effectiveness of the DGFM VSC with the LC DVSC designed using the proposed guidelines in all three operation modes.Overall,the paper demonstrates the feasibility of employing the DGFM VSC with the LC DVSC for all three possible operation modes,which can help overcome the challenges associated with accommodating and coordinating heterogeneous VSCs in the power system.展开更多
The development of subsea all-electric Christmas trees is an area of focus in the offshore oil industry worldwide.The main difficulties are associated with the development and control strategies for subsea all-electri...The development of subsea all-electric Christmas trees is an area of focus in the offshore oil industry worldwide.The main difficulties are associated with the development and control strategies for subsea all-electric actuators,which are the most criti-cal components of subsea Christmas trees.A single-motor-level fuzzy PID control with an integrated working condition detection mod-ule and a three-motor redundant-level deviation strategy with coupled joint synchronous control were proposed in this paper to real-ize the real time determination of algorithm parameters according to the working conditions,solve the rapid redistribution problems,and maintain the fast speed of the servo motor of the subsea all-electric tree valve actuator.A synchronous control electrical system was built,tested,and verified through simulation analysis.Test results show that the two redundant servo motors can still control the all-electric valve actuator and provide good synchronization control capabilities despite the failure of one servo motor,and the verti-cal and horizontal vibration values of the system are within reasonable ranges.The synchronous control strategy can be applied to the synchronous control problem of subsea all-electric production systems,which is of considerable importance for the development of subsea all-electric production systems.展开更多
Two-lap sequential control converters are usually adopted to supply and improve the power factor of input side. The line harmonic damage generated by a sequential control thyristor converter can be serious. To solve t...Two-lap sequential control converters are usually adopted to supply and improve the power factor of input side. The line harmonic damage generated by a sequential control thyristor converter can be serious. To solve this prob-lem and seek an optimum control strategy,we derived the changeable regular of the line-input-current,the fundamen-tal-frequency-current,the harmonic-current-content and the harmonic total distortion ratio of the converter at different firing angles. We obtained relevant data from experiments with a sequential control system of a DC 2.2kW/220V motor. With the example of the operating condition of a DC mine elevator,the harmonic current is two times approximately in sequential control compared to synchronous control when the firing angle of the two converters differs in 30°. At dif-ferent operating states of a two-lap connection converter,the ideal strategy is an exchange between sequential control and synchronous control,by which we can achieve the complementary goal of improving the power factor and har-monic effect. All analytical conclusions are supported by simulation and experimental results.展开更多
We present a compact optical delay line(ODL)with wide-range continuous tunability on thin-film lithium niobate platform.The proposed device integrates an unbalanced Mach-Zehnder interferometer(MZI)architecture with du...We present a compact optical delay line(ODL)with wide-range continuous tunability on thin-film lithium niobate platform.The proposed device integrates an unbalanced Mach-Zehnder interferometer(MZI)architecture with dual tunable couplers,where each coupler comprises two 2×2 multimode interferometers and a MZI phase-tuning section.Experimental results demonstrate continuous delay tuning from 0 to 293 ps through synchronized control of coupling coefficients,corresponding to a 4 cm path difference between interferometer arms.The measured delay range exhibits excellent agreement with theoretical predictions derived from ODL waveguide parameters.This result addresses critical challenges in integrated photonic systems that require precise temporal control,particularly for applications in optical communications and quantum information processing,where a wide tuning range is paramount.展开更多
With the help of adaptive control theory to chaos synchronization, this paper provides a kind of controlling strategy that is adaptive control by which we can synchronize the Lorenz chaotic dynamical system. The theor...With the help of adaptive control theory to chaos synchronization, this paper provides a kind of controlling strategy that is adaptive control by which we can synchronize the Lorenz chaotic dynamical system. The theoretical analysis and simulation show using this controlling strategy, we can synchronize chaotic systems with the unknown parameters and the different initial conditions.展开更多
A new dual-actuator fatigue loading system of wind turbine blades was designed.Compared with the traditional pendulum loading mode,the masses in this system only moved linearly along the loading direction to increase ...A new dual-actuator fatigue loading system of wind turbine blades was designed.Compared with the traditional pendulum loading mode,the masses in this system only moved linearly along the loading direction to increase the exciting force.However,the two actuators and the blade constituted a complicated non-linear energy transferring system,which led to the non-synchronization of actuators.On-site test results showed that the virtual spindle synchronous strategy commonly used in synchronous control was undesirable and caused the instability of the blade’s amplitude eventually.A cross-coupled control strategy based on the active disturbance rejection algorithm was proposed.Firstly,a control system model was built according to the synchronization error and tracking error.Furthermore,based on arranging the transition process,estimating the system state and error feedback,and compensating disturbance,an active disturbance rejection controller was designed by adopting the optimal control function.Finally,on-site test results showed that the cross-coupled control strategy based on the active disturbance rejection algorithm could ensure the synchronization of two actuators.The maximum speed synchronization error of the two motors was less than 16 RPM,the displacement synchronization error of the two actuators was less than 0.25 mm and approaching zero after 4 seconds,and the peak value of vibration of the blade was less than 5 mm,which satisfied the fatigue test requirement.展开更多
In this article,the robust control problem of discrete-time Markov jump systems(MJSs)with actuator saturation is investigated via the passivity theory.Under the assumption of mode synchronization between the system an...In this article,the robust control problem of discrete-time Markov jump systems(MJSs)with actuator saturation is investigated via the passivity theory.Under the assumption of mode synchronization between the system and the controller,sufficient conditions are established to guarantee the system to be mean-square stable and stochastically passive in the domain of attraction via the saturation-dependent Lyapunov function approach and the linear matrix inequality(LMI)technique.The coupling between the system variables is decoupled,which greatly facilitates the design of the synchronization controller.,Moreover,the estimation of the domain of attraction for the considered MJSs is accomplished through the solution of an optimization problem(OP).By degenerating the mode-dependent controller into its mode-independent counterpart,we derive sufficient conditions to ensure system robustness under the mode-independent control strategy,and then systematically summarize these conditions.Finally,the effectiveness of the proposed integrated design methodology is validated through numerical simulations.展开更多
This paper builds up an accurate nonlinear mathematical model of anelectro-hydraulic force/ torque servo control system, and provides a thorough theoretical analysison the feedforward compensation for extraneous force...This paper builds up an accurate nonlinear mathematical model of anelectro-hydraulic force/ torque servo control system, and provides a thorough theoretical analysison the feedforward compensation for extraneous force/torque, whose limitation is analyzed andrevealed. The nonlinear factors and the servo valve dynamics have much influence on the systemcharacteristics. Subsequently a velocity syn-chronizing-compensation method by using the controlsignal of the control actuator is proposed, which can reduce the lagging effects for the betterperformance. For the reason of similarity between the model of control actuator and that of the loadsimulator, the proposed method performs well against the influence of nonlinear factors. Thesimulations and the experiments confirm that this control scheme results in a quick response,robustness, and excellent ability against disturbance.展开更多
Grid-forming(GFM)converters can provide inertia support for power grids through control technology,stabilize voltage and frequency,and improve system stability,unlike traditional grid-following(GFL)converters.Therefor...Grid-forming(GFM)converters can provide inertia support for power grids through control technology,stabilize voltage and frequency,and improve system stability,unlike traditional grid-following(GFL)converters.Therefore,in future“double high”power systems,research on the control technology of GFM converters will become an urgent demand.In this paper,we first introduce the basic principle of GFM control and then present five currently used control strategies for GFM converters:droop control,power synchronization control(PSC),virtual synchronous machine control(VSM),direct power control(DPC),and virtual oscillator control(VOC).These five strategies can independently establish voltage phasors to provide inertia to the system.Among these,droop control is the most widely used strategy.PSC and VSM are strategies that simulate the mechanical characteristics of synchronous generators;thus,they are more accurate than droop control.DPC regulates the active power and reactive power directly,with no inner current controller,and VOC is a novel method under study using an oscillator circuit to realize synchronization.Finally,we highlight key technologies and research directions to be addressed in the future.展开更多
The synchronous conditions of two kinds of the small-world (SW) network are studied. The small world topology can affect on dynamical behaviors of the beam transport network (BTN) largely, if the BTN is constructe...The synchronous conditions of two kinds of the small-world (SW) network are studied. The small world topology can affect on dynamical behaviors of the beam transport network (BTN) largely, if the BTN is constructed with the SW topology, the global linear coupling and special linear feedback can realize the synchronization control of beam halo-chaos as well as periodic state in the BTN with the SW topology, respectively. This important result can provide an effective way for the experimental study and the engineering design of the BTN in the high-current accelerator driven radioactive clean nuclear power systems, and may have potential use in prospective applications for halo-chaos secure communication.展开更多
In this paper we present the control and synchronization of a coupled Bragg acousto-optic bistable map system using nonlinear feedback technology. This nonlinear feedback technology is useful to control a temporally c...In this paper we present the control and synchronization of a coupled Bragg acousto-optic bistable map system using nonlinear feedback technology. This nonlinear feedback technology is useful to control a temporally chaotic system as well as a spatiotemporally chaotic system. It can be extended to synchronize the spatiotemporal chaos. It can work in a wide range of the controlled and synchronized signals, so it can decrease the sensitivity down to a noise level. The synchronization can be obtained by the analysis of the largest conditional Lyapunov exponent spectrum, and easily implemented in practical systems just by adjusting the coupled strength without any pre-knowledge of the dynamic system required.展开更多
For the outputs of two nth-order linear control systems to work insynchronization and meanwhile to track their commands, a H_(infinity) synchronization control schemeis presented. In terms of two uncoupled single vari...For the outputs of two nth-order linear control systems to work insynchronization and meanwhile to track their commands, a H_(infinity) synchronization control schemeis presented. In terms of two uncoupled single variable linear systems, a multivariable coupledsystem is established by choosing one output and the difference of the two outputs as a new outputvector, so that both command tracking and synchronization properties can be demonstrated by aH_(infinity) performance index. To improve the synchronization and trailing performance and toguarantee the system robust stability, the mixed sensitivity H_(infinity), design methodology isadopted. The presented synchronization scheme is then extended to the case where one of the twosystems include two input variables, and then applied to the position synchronization control of awafer-retical stage. The wafer-reticle stage consists of a wafer stage, a reticle coarse stage, anda reticle fine stage. The reticle coarse stage picks up the reticle fine stage. The three stagesought to tack their commands, but synchronization between the wafer stage and the reticle fine stagemust be stressed in the tracking process. In the application, by appropriately determining theweighting matrices for the sensitivity function and the complementary sensitivity function, asatisfactory KL synchronization controller is obtained to realize highly accurate positionsynchronization, and to guarantee tracking performance. The above results are verified by simulationexperiments.展开更多
文摘To explore the technical solution for independently-developed wireless synchronous control of locomotives based on 5G-R,this study investigates the service demands of such control and analyzes the insufficiency of the existing communication system of China's heavy-haul railway.Giving full consideration of the high bandwidth,low delay,IP-based links,packet domain transmission,quality of service priority guarantee and other characteristics of the 5G-R network,an overall technical solution is proposed,focusing on the implementation of functions such as master-slave locomotive data transmission,controllable end-of-train data transmission,marshaling requests,and multi-driver calls.The findings contribute to enhancing the advancement of the independently-developed wireless synchronous control system of locomotives,ensuring its reliable operation in complex environments,providing valuable guidance for improving the safety and efficiency of heavy-haul railway transportation,and offering robust technical support for the modernization and intelligence development of heavy-haul railway.
基金The project supported by the National Meg-Science Engineering Project of Chinese Goverment
文摘The vertical position of plasma in the HT-7U Tokamak is inherently unstable. In order to realize active stabilization, the response rate of the high-power high-frequency amplifier feeding the active control coils must be fast enough. This paper analyzes the paralleling scheme of the power amplifier through two kinds of control mode. One is the synchronous control; the other is the asynchronous control. Via the comparison of the two kinds of control mode, both of their characteristics are given in the text. At last, the analyzed result is verified by a small power experiment.
基金supported in part by the National Natural Science Foundation of China(No.52377186)the Natural Science Foundation of Guangdong Province(No.2024A1515012428)+1 种基金the Science and Technology Planning Project of Guangdong Province,China(No.2023A1111120023)the Basic and Applied Basic Research Foundation of Guangdong Province(No.2022A1515240026)。
文摘The increasing adoption of grid-forming converters(GFMCs)stems from their capacity to furnish voltage and frequency support for power grids.Nevertheless,GFMCs employing the current reference saturation limiting method often exhibit instability during various transient disturbances including grid voltage sags,frequency variations,and phase jumps.To address this problem,this paper proposes a virtual power angle synchronous(δv-SYN)control method.The fundamental of this method is to achieve synchronization with the grid using the virtual power angleδv instead of the active power.The transient stability characteristics of the proposed method are theoretically elucidated using a novel virtual power angle-power angle(δv-δ)model.The key benefit of the proposed method is its robustness to various grid strengths and diverse forms of transient disturbances,eliminating the requirement for fault identification or control switching.Moreover,it can offer grid-forming support to the grid during grid faults.Hardware-in-the-loop experimental results validate the theoretical analysis and the performance of the proposed method.
基金supported by the National Natural Science Foundation of China(No.52077222)the Shandong Provincial Natural Science Foundation(No.ZR2023QE156)。
文摘The brushless doubly-fed induction generator(BDFIG)presents significant potential for application in wind power systems,primarily due to the elimination of slip rings and brushes.The application of virtual synchronous control(VSynC)has been demonstrated to effectively augment the inertia of BDFIG systems.However,the dynamic characteristics and stability of BDFIG under weak grid conditions remain largely unexplored.The critical stabilizing factors for BDFIG-based wind turbines(WTs)are methodically investigated,and an enhanced VSynC method based on linear active disturbance rejection control(LADRC)is proposed.The stability analysis reveals that the proposed method can virtually enhance the stability of the grid-connected system under weak grid conditions.The accuracy of the theoretical analysis and the effectiveness of the proposed method are affirmed through extensive simulations and detailed experiments.
基金supported in part by the National Natural Science Foundation of China(62033005,62273270)the Natural Science Foundation of Shaanxi Province(2023JC-XJ17)
文摘Dear Editor,This letter proposes a deep synchronization control(DSC) method to synchronize grid-forming converters with power grids. The method involves constructing a novel controller for grid-forming converters based on the stable deep dynamics model. To enhance the performance of the controller, the dynamics model is optimized within the deep reinforcement learning(DRL) framework. Simulation results verify that the proposed method can reduce frequency deviation and improve active power responses.
文摘This paper explores the issue of secure synchronization control in piecewise-homogeneous Markovian jump delay neural networks affected by denial-of-service(DoS)attacks.Initially,a novel memory-based adaptive event-triggered mechanism(MBAETM)is designed based on sequential growth rates,focusing on event-triggered conditions and thresholds.Subsequently,from the perspective of defenders,non-periodic DoS attacks are re-characterized,and a model of irregular DoS attacks with cyclic fluctuations within time series is further introduced to enhance the system's defense capabilities more effectively.Additionally,considering the unified demands of network security and communication efficiency,a resilient memory-based adaptive event-triggered mechanism(RMBAETM)is proposed.A unified Lyapunov-Krasovskii functional is then constructed,incorporating a loop functional to thoroughly consider information at trigger moments.The master-slave system achieves synchronization through the application of linear matrix inequality techniques.Finally,the proposed methods'effectiveness and superiority are confirmed through four numerical simulation examples.
基金funded by“The Fourth Phase of 2022 Advantage Discipline Engineering-Control Science and Engineering”,grant number 4013000063.
文摘The rapid development of new energy power generation technology and the transformation of power electronics in the core equipment of source-grid-load drives the power system towards the“double-high”development pattern of“high proportion of renewable energy”and“high proportion of power electronic equipment”.To enhance the transient performance of AC/DC hybrid microgrid(HMG)in the context of“double-high,”aπtype virtual synchronous generator(π-VSG)control strategy is applied to bidirectional interface converter(BIC)to address the issues of lacking inertia and poor disturbance immunity caused by the high penetration rate of power electronic equipment and new energy.Firstly,the virtual synchronous generator mechanical motion equations and virtual capacitance equations are used to introduce the virtual inertia control equations that consider the transient performance of HMG;based on the equations,theπ-type equivalent control model of the BIC is established.Next,the inertia power is actively transferred through the BIC according to the load fluctuation to compensate for the system’s inertia deficit.Secondly,theπ-VSG control utilizes small-signal analysis to investigate howthe fundamental parameters affect the overall stability of the HMG and incorporates power step response curves to reveal the relationship between the control’s virtual parameters and transient performance.Finally,the PSCAD/EMTDC simulation results show that theπ-VSG control effectively improves the immunity of AC frequency and DC voltage in the HMG system under the load fluctuation condition,increases the stability of the HMG system and satisfies the power-sharing control objective between the AC and DC subgrids.
基金supported by the National Natural Science Foundation of China(Nos.51675430,11402044,and U1537213)
文摘A synchronous control of relative attitude and position is required in separated ultraquiet spacecraft, such as drag-free, disturbance-free, and distributed spacecraft. Thus, a twistorbased synchronous sliding mode control is investigated in this paper to solve the control problem of relative attitude and position among separated spacecraft modules. The twistor-based control design and the stability proof are implemented using the Modified Rodrigues Parameter(MRP).To evaluate the effectiveness of the proposed control method, this paper presents a case study of separated spacecraft flying control considering the mass uncertainty and external disturbances. In addition, a simulation study of the Proportional-Derivative(PD) control is also presented for comparison. The results indicate that the twistor-based sliding mode controller can ensure global asymptotic stability. The states converge fast with ultra-precision and ultra-stability in both the attitude and position. Moreover, the proposed twistor-based sliding mode control system is robust to the mass uncertainty and external disturbances.
基金supported in part by the Nebraska Center for Energy Sciences Research.
文摘Grid-tie voltage source converters(VSCs)can operate in three distinct modes:AC-dominant,DC-dominant,and balanced,depending on the placement of the stiff voltage sources.The distinct operation modes of the VSCs traditionally demand different synchronization control techniques,leading to heterogeneous VSCs.It is challenging for the power system to accommodate and coordinate heterogeneous VSCs.A promising universal synchronization control technique for VSCs is the DC-link voltage synchronization control(DVSC)based on a lead compensator(LC).The LC DVSC stabilizes both the DC and AC voltages of a VSC while achieving synchronization with the AC grid.This results in a dual-port grid-forming(DGFM)characteristic for the VSC.However,there has been very limited study on the stability and synchronization controller design of the VSCs with the LC DVSC operating in various modes.To bridge this gap,the paper presents a quantitative analysis on the stability and steady-state performance of the LC DVSC in all three operation modes of the DGFM VSC.Based on the analysis,the paper provides step-by-step design guidelines for the LC DVSC.Furthermore,the paper uncovers an instability issue related to the LC DVSC when the DGFM VSC operates in the balanced mode.To tackle the instability issue,a virtual resistance control is proposed and integrated with the LC DVSC.Simulation results validate the analysis and demonstrate the effectiveness of the DGFM VSC with the LC DVSC designed using the proposed guidelines in all three operation modes.Overall,the paper demonstrates the feasibility of employing the DGFM VSC with the LC DVSC for all three possible operation modes,which can help overcome the challenges associated with accommodating and coordinating heterogeneous VSCs in the power system.
基金support of the Shandong Provincial Natural Science Foundation(No.ZR2021QE059)the National Natural Science Foundation of China(No.51974169)the Key R&D Program of Shandong Province(No.2019GGX101020).
文摘The development of subsea all-electric Christmas trees is an area of focus in the offshore oil industry worldwide.The main difficulties are associated with the development and control strategies for subsea all-electric actuators,which are the most criti-cal components of subsea Christmas trees.A single-motor-level fuzzy PID control with an integrated working condition detection mod-ule and a three-motor redundant-level deviation strategy with coupled joint synchronous control were proposed in this paper to real-ize the real time determination of algorithm parameters according to the working conditions,solve the rapid redistribution problems,and maintain the fast speed of the servo motor of the subsea all-electric tree valve actuator.A synchronous control electrical system was built,tested,and verified through simulation analysis.Test results show that the two redundant servo motors can still control the all-electric valve actuator and provide good synchronization control capabilities despite the failure of one servo motor,and the verti-cal and horizontal vibration values of the system are within reasonable ranges.The synchronous control strategy can be applied to the synchronous control problem of subsea all-electric production systems,which is of considerable importance for the development of subsea all-electric production systems.
基金Project GC06A523 supported by the Science and Technology Department of Heilongjiang Province
文摘Two-lap sequential control converters are usually adopted to supply and improve the power factor of input side. The line harmonic damage generated by a sequential control thyristor converter can be serious. To solve this prob-lem and seek an optimum control strategy,we derived the changeable regular of the line-input-current,the fundamen-tal-frequency-current,the harmonic-current-content and the harmonic total distortion ratio of the converter at different firing angles. We obtained relevant data from experiments with a sequential control system of a DC 2.2kW/220V motor. With the example of the operating condition of a DC mine elevator,the harmonic current is two times approximately in sequential control compared to synchronous control when the firing angle of the two converters differs in 30°. At dif-ferent operating states of a two-lap connection converter,the ideal strategy is an exchange between sequential control and synchronous control,by which we can achieve the complementary goal of improving the power factor and har-monic effect. All analytical conclusions are supported by simulation and experimental results.
基金supported by the National Natural Science Foundation of China(Grant Nos.12192251,12334014,12404378,92480001,12134001,12174113,12174107,12474325,12404379,and 12474378)the Innovation Program for Quantum Science and Technology(Grant No.2021ZD0301403)+1 种基金Shanghai Municipal Science and Technology Major Project(Grant No.2019SHZDZX01)Fundamental Research Funds for the Central Universities,the Engineering Research Center for Nanophotonics&Advanced Instrument,Ministry of Education,East China Normal University(Grant No.2023nmc005).
文摘We present a compact optical delay line(ODL)with wide-range continuous tunability on thin-film lithium niobate platform.The proposed device integrates an unbalanced Mach-Zehnder interferometer(MZI)architecture with dual tunable couplers,where each coupler comprises two 2×2 multimode interferometers and a MZI phase-tuning section.Experimental results demonstrate continuous delay tuning from 0 to 293 ps through synchronized control of coupling coefficients,corresponding to a 4 cm path difference between interferometer arms.The measured delay range exhibits excellent agreement with theoretical predictions derived from ODL waveguide parameters.This result addresses critical challenges in integrated photonic systems that require precise temporal control,particularly for applications in optical communications and quantum information processing,where a wide tuning range is paramount.
文摘With the help of adaptive control theory to chaos synchronization, this paper provides a kind of controlling strategy that is adaptive control by which we can synchronize the Lorenz chaotic dynamical system. The theoretical analysis and simulation show using this controlling strategy, we can synchronize chaotic systems with the unknown parameters and the different initial conditions.
基金the National Key R&D Program of China,Grant No.2018YFB1501203Meanwhile,this research was funded by the Natural Science Foundation of Shandong,Grant No.ZR2019MEE076And the work in this paper has partly received funding from the National Key R&D Program of Shandong,Grant No.2019GGX104001.
文摘A new dual-actuator fatigue loading system of wind turbine blades was designed.Compared with the traditional pendulum loading mode,the masses in this system only moved linearly along the loading direction to increase the exciting force.However,the two actuators and the blade constituted a complicated non-linear energy transferring system,which led to the non-synchronization of actuators.On-site test results showed that the virtual spindle synchronous strategy commonly used in synchronous control was undesirable and caused the instability of the blade’s amplitude eventually.A cross-coupled control strategy based on the active disturbance rejection algorithm was proposed.Firstly,a control system model was built according to the synchronization error and tracking error.Furthermore,based on arranging the transition process,estimating the system state and error feedback,and compensating disturbance,an active disturbance rejection controller was designed by adopting the optimal control function.Finally,on-site test results showed that the cross-coupled control strategy based on the active disturbance rejection algorithm could ensure the synchronization of two actuators.The maximum speed synchronization error of the two motors was less than 16 RPM,the displacement synchronization error of the two actuators was less than 0.25 mm and approaching zero after 4 seconds,and the peak value of vibration of the blade was less than 5 mm,which satisfied the fatigue test requirement.
基金Project supported by the National Natural Science Foundation of China(No.62303421)the Zhejiang Provincial Natural ScienceFoundation of China(No.LQ23F030018)。
文摘In this article,the robust control problem of discrete-time Markov jump systems(MJSs)with actuator saturation is investigated via the passivity theory.Under the assumption of mode synchronization between the system and the controller,sufficient conditions are established to guarantee the system to be mean-square stable and stochastically passive in the domain of attraction via the saturation-dependent Lyapunov function approach and the linear matrix inequality(LMI)technique.The coupling between the system variables is decoupled,which greatly facilitates the design of the synchronization controller.,Moreover,the estimation of the domain of attraction for the considered MJSs is accomplished through the solution of an optimization problem(OP).By degenerating the mode-dependent controller into its mode-independent counterpart,we derive sufficient conditions to ensure system robustness under the mode-independent control strategy,and then systematically summarize these conditions.Finally,the effectiveness of the proposed integrated design methodology is validated through numerical simulations.
文摘This paper builds up an accurate nonlinear mathematical model of anelectro-hydraulic force/ torque servo control system, and provides a thorough theoretical analysison the feedforward compensation for extraneous force/torque, whose limitation is analyzed andrevealed. The nonlinear factors and the servo valve dynamics have much influence on the systemcharacteristics. Subsequently a velocity syn-chronizing-compensation method by using the controlsignal of the control actuator is proposed, which can reduce the lagging effects for the betterperformance. For the reason of similarity between the model of control actuator and that of the loadsimulator, the proposed method performs well against the influence of nonlinear factors. Thesimulations and the experiments confirm that this control scheme results in a quick response,robustness, and excellent ability against disturbance.
基金supported by the National Natural Science Foundation of China(No.52177122)the“Transformational Technologies for Clean Energy and Demonstration”,Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA 21050100)the Youth Innovation Promotion Association CAS(No.2018170)。
文摘Grid-forming(GFM)converters can provide inertia support for power grids through control technology,stabilize voltage and frequency,and improve system stability,unlike traditional grid-following(GFL)converters.Therefore,in future“double high”power systems,research on the control technology of GFM converters will become an urgent demand.In this paper,we first introduce the basic principle of GFM control and then present five currently used control strategies for GFM converters:droop control,power synchronization control(PSC),virtual synchronous machine control(VSM),direct power control(DPC),and virtual oscillator control(VOC).These five strategies can independently establish voltage phasors to provide inertia to the system.Among these,droop control is the most widely used strategy.PSC and VSM are strategies that simulate the mechanical characteristics of synchronous generators;thus,they are more accurate than droop control.DPC regulates the active power and reactive power directly,with no inner current controller,and VOC is a novel method under study using an oscillator circuit to realize synchronization.Finally,we highlight key technologies and research directions to be addressed in the future.
基金The project supported by the Key Projects of National Natural Science Foundation of China under Grant No. 70431002 and National Natural Science Foundation of China under Grant Nos. 70371068 and 10247005
文摘The synchronous conditions of two kinds of the small-world (SW) network are studied. The small world topology can affect on dynamical behaviors of the beam transport network (BTN) largely, if the BTN is constructed with the SW topology, the global linear coupling and special linear feedback can realize the synchronization control of beam halo-chaos as well as periodic state in the BTN with the SW topology, respectively. This important result can provide an effective way for the experimental study and the engineering design of the BTN in the high-current accelerator driven radioactive clean nuclear power systems, and may have potential use in prospective applications for halo-chaos secure communication.
文摘In this paper we present the control and synchronization of a coupled Bragg acousto-optic bistable map system using nonlinear feedback technology. This nonlinear feedback technology is useful to control a temporally chaotic system as well as a spatiotemporally chaotic system. It can be extended to synchronize the spatiotemporal chaos. It can work in a wide range of the controlled and synchronized signals, so it can decrease the sensitivity down to a noise level. The synchronization can be obtained by the analysis of the largest conditional Lyapunov exponent spectrum, and easily implemented in practical systems just by adjusting the coupled strength without any pre-knowledge of the dynamic system required.
基金This project is supported by Japan Society for the Promotion of Sci-ence(No.P01208)National Natural Science Foundation of China (No.60104003).
文摘For the outputs of two nth-order linear control systems to work insynchronization and meanwhile to track their commands, a H_(infinity) synchronization control schemeis presented. In terms of two uncoupled single variable linear systems, a multivariable coupledsystem is established by choosing one output and the difference of the two outputs as a new outputvector, so that both command tracking and synchronization properties can be demonstrated by aH_(infinity) performance index. To improve the synchronization and trailing performance and toguarantee the system robust stability, the mixed sensitivity H_(infinity), design methodology isadopted. The presented synchronization scheme is then extended to the case where one of the twosystems include two input variables, and then applied to the position synchronization control of awafer-retical stage. The wafer-reticle stage consists of a wafer stage, a reticle coarse stage, anda reticle fine stage. The reticle coarse stage picks up the reticle fine stage. The three stagesought to tack their commands, but synchronization between the wafer stage and the reticle fine stagemust be stressed in the tracking process. In the application, by appropriately determining theweighting matrices for the sensitivity function and the complementary sensitivity function, asatisfactory KL synchronization controller is obtained to realize highly accurate positionsynchronization, and to guarantee tracking performance. The above results are verified by simulationexperiments.