期刊文献+
共找到168篇文章
< 1 2 9 >
每页显示 20 50 100
Chattering-free terminal sliding mode control based on adaptive exponential reaching barrier function for a chaotic permanent magnet synchronous generator in offshore wind turbine system
1
作者 Aissa Benabdeseelam Manal Messadi +1 位作者 Karim Kemih Hamid Hamiche 《Chinese Physics B》 2025年第9期104-113,共10页
This paper introduces a novel chattering-free terminal sliding mode control(SMC)strategy to address chaotic behavior in permanent magnet synchronous generators(PMSG)for offshore wind turbine systems.By integrating an ... This paper introduces a novel chattering-free terminal sliding mode control(SMC)strategy to address chaotic behavior in permanent magnet synchronous generators(PMSG)for offshore wind turbine systems.By integrating an adaptive exponential reaching law with a continuous barrier function,the proposed approach eliminates chattering and ensures robust performance under model uncertainties.The methodology combines adaptive SMC with dynamic switching to estimate and compensates for unknown uncertainties,providing smooth and stable control.Finally,the performance and effectiveness of the proposed approach are compared with those of a previous study. 展开更多
关键词 permanent magnet synchronous generator chaotic system terminal sliding mode control exponential reaching adaptive barrier function chattering-free unknown uncertainty
原文传递
Improved Strategy of Grid-Forming Virtual Synchronous Generator Based on Transient Damping 被引量:2
2
作者 Lei Zhang Rongliang Shi +2 位作者 Junhui Li Yannan Yu Yu Zhang 《Energy Engineering》 EI 2024年第11期3181-3197,共17页
The grid-forming virtual synchronous generator(GFVSG)not only employs a first-order low-pass filter for virtual inertia control but also introduces grid-connected active power(GCAP)dynamic oscillation issues,akin to t... The grid-forming virtual synchronous generator(GFVSG)not only employs a first-order low-pass filter for virtual inertia control but also introduces grid-connected active power(GCAP)dynamic oscillation issues,akin to those observed in traditional synchronous generators.In response to this,an improved strategy for lead-lag filter based GFVSG(LLF-GFVSG)is presented in this article.Firstly,the grid-connected circuit structure and control principle of typical GFVSG are described,and a closed-loop small-signal model for GCAP in GFVSG is established.The causes of GCAP dynamic oscillation of GFVSG under the disturbances of active power command as well as grid frequency are analyzed.On this basis,the LLF-GFVSG improvement strategy and its parameter design method are given.Finally,the efficiency of the proposed control strategy in damping GCAP dynamic oscillations under various disturbances is verified using MATLAB simulations and experimental comparison results. 展开更多
关键词 Grid-forming virtual synchronous generator first-order low-pass filter lead-lag filter small-signal model parameter design
在线阅读 下载PDF
Transient Damping of Virtual Synchronous Generator for Enhancing Synchronization Stability during Voltage Dips
3
作者 Shitao Sun Yu Lei +4 位作者 Guowen Hao Yi Lu Jindong Liu Zhaoxin Song Jie Zhang 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期143-151,共9页
Virtual synchronous generators(VSGs)are widely introduced to the renewable power generation,the variablespeed pumped storage units,and so on,as a promising gridforming solution.It is noted that VSGs can provide virtua... Virtual synchronous generators(VSGs)are widely introduced to the renewable power generation,the variablespeed pumped storage units,and so on,as a promising gridforming solution.It is noted that VSGs can provide virtual inertia for frequency support,but the larger inertia would worsen the synchronization stability,referring to keeping synchronization with the grid during voltage dips.Thus,this paper presents a transient damping method of VSGs for enhancing the synchronization stability during voltage dips.It is revealed that the loss of synchronization(LOS)of VSGs always accompanies with the positive frequency deviation and the damping is the key factor to remove LOS when the equilibrium point exists.In order to enhance synchronization stability during voltage dips,the transient damping is proposed,which is generated by the frequency deviation in active power loop.Additionally,the proposed method can realize seamless switching between normal state and grid fault.Moreover,detailed control design for transient damping gain is given to ensure the synchronization stability under different inertia requirements during voltage dips.Finally,the experimental results are presented to validate the analysis and the effectiveness of the improved transient damping method. 展开更多
关键词 Virtual synchronous generator(VSG) Transient damping Synchronization stability Voltage dips
在线阅读 下载PDF
An Adaptive Control Strategy for Energy Storage Interface Converter Based on Analogous Virtual Synchronous Generator
4
作者 Feng Zhao Jinshuo Zhang +1 位作者 Xiaoqiang Chen Ying Wang 《Energy Engineering》 EI 2024年第2期339-358,共20页
In the DC microgrid,the lack of inertia and damping in power electronic converters results in poor stability of DC bus voltage and low inertia of the DC microgrid during fluctuations in load and photovoltaic power.To ... In the DC microgrid,the lack of inertia and damping in power electronic converters results in poor stability of DC bus voltage and low inertia of the DC microgrid during fluctuations in load and photovoltaic power.To address this issue,the application of a virtual synchronous generator(VSG)in grid-connected inverters control is referenced and proposes a control strategy called the analogous virtual synchronous generator(AVSG)control strategy for the interface DC/DC converter of the battery in the microgrid.Besides,a flexible parameter adaptive control method is introduced to further enhance the inertial behavior of the AVSG control.Firstly,a theoretical analysis is conducted on the various components of the DC microgrid,the structure of analogous virtual synchronous generator,and the control structure’s main parameters related to the DC microgrid’s inertial behavior.Secondly,the voltage change rate tracking coefficient is introduced to adjust the change of the virtual capacitance and damping coefficient flexibility,which further strengthens the inertia trend of the DC microgrid.Additionally,a small-signal modeling approach is used to analyze the approximate range of the AVSG’s main parameters ensuring system stability.Finally,conduct a simulation analysis by building the model of the DC microgrid system with photovoltaic(PV)and battery energy storage(BES)in MATLAB/Simulink.Simulation results from different scenarios have verified that the AVSG control introduces fixed inertia and damping into the droop control of the battery,resulting in a certain level of inertia enhancement.Furthermore,the additional adaptive control strategy built upon the AVSG control provides better and flexible inertial support for the DC microgrid,further enhances the stability of the DC bus voltage,and has a more positive impact on the battery performance. 展开更多
关键词 Adaptive control analogous virtual synchronous generator DC/DC converter inertia of DC microgrid DC microgrid with PV and BES BATTERY DC bus voltage
在线阅读 下载PDF
Adaptive Control Strategy for Inertia and Damping of Virtual Synchronous Generator Based on CNN-LSTM Data-Driven Model
5
作者 LUAN Xiyu ZENG Guohui +3 位作者 ZHAO Jinbin TIAN Jiangbin ZHANG Zhenhua LIU Jin 《Wuhan University Journal of Natural Sciences》 CSCD 2024年第6期579-588,共10页
With the application of distributed power sources,the stability of the power system has been dramatically affected.Therefore,scholars have proposed the concept of a virtual synchronous generator(VSG).However,after the... With the application of distributed power sources,the stability of the power system has been dramatically affected.Therefore,scholars have proposed the concept of a virtual synchronous generator(VSG).However,after the system is disturbed,how to make it respond quickly and effectively to maintain the stability of the system becomes a complex problem.To address this problem,a frequency prediction component is incorporated into the control module of the VSG to enhance its performance.The Convolutional Neural NetworkLong Short-Term Memory(CNN-LSTM)model is used for frequency prediction,ensuring that the maximum energy capacity released by the storage system is maintained.Additionally,it guarantees that the inverter's output power does not exceed its rated capacity,based on the predicted frequency limit after the system experiences a disturbance.The advantage of real-time adjustment of inverter parameters is that the setting intervals for inertia and damping can be increased.The selection criteria for inertia and damping can be derived from the power angle oscillation curve of the synchronous generator.Consequently,an adaptive control strategy for VSG parameters is implemented to enhance the system's frequency restoration following disturbances.The validity and effectiveness of the model are verified through simulations in Matlab/Simulink. 展开更多
关键词 virtual synchronous generator(VSG) adaptive control frequency restoration convolutional neural network-long short-term memory(CNN-LSTM)
原文传递
A fault warning for inter-turn short circuit of excitation winding of synchronous generator based on GRU-CNN 被引量:7
6
作者 Junqing Li Jing Liu Yating Chen 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期236-248,共13页
Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding ... Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally. 展开更多
关键词 synchronous generator Inter-turn short circuit Excitation winding Fault warning GRU-CNN IPSO
在线阅读 下载PDF
Maximum Power Point Tracking in Variable Speed Wind Turbine Based on Permanent Magnet Synchronous Generator Using Maximum Torque Sliding Mode Control Strategy 被引量:3
7
作者 Esmaeil Ghaderi Hossein Tohidi Behnam Khosrozadeh 《Journal of Electronic Science and Technology》 CAS CSCD 2017年第4期391-399,共9页
The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, th... The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG). 展开更多
关键词 Maximum power point tracking permanent magnet synchronous generator(PMSG) sliding mode control wind turbine
在线阅读 下载PDF
Adaptive H-infinity control of synchronous generators with steam valve via Hamiltonian function method 被引量:2
8
作者 Shujuan LI Yuzhen WANG 《控制理论与应用(英文版)》 EI 2006年第2期105-110,共6页
Based on Hamiltonian formulation, this paper proposes a design approach to nonlinear feedback excitation control of synchronous generators with steam valve control, disturbances and unknown parameters. It is shown tha... Based on Hamiltonian formulation, this paper proposes a design approach to nonlinear feedback excitation control of synchronous generators with steam valve control, disturbances and unknown parameters. It is shown that the dynamics of the synchronous generators can be expressed as a dissipative Hamiltonian system, based on which an adaptive H-infinity controller is then designed for the systems by using the structure properties of dissipative Hamiltonian systems. Simulations show that the controller obtained in this paper is very effective. 展开更多
关键词 synchronous generator Excitation control Steam valve control Hamiltonian function method Adaptive H-infinity controller.
在线阅读 下载PDF
Research on Control Strategy of Grid-connected Brushless Doubly-fed Wind Power System Based on Virtual Synchronous Generator Control 被引量:7
9
作者 Shuai Liang Shi Jin Long Shi 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期404-412,共9页
The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of ... The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation. 展开更多
关键词 Virtual synchronous generator Brushless doubly-fed relutance generator Grid support ability Voltage source control
在线阅读 下载PDF
Predictive control of a chaotic permanent magnet synchronous generator in a wind turbine system 被引量:1
10
作者 Manal Messadi Adel Mellit +1 位作者 Karim Kemih Malek Ghanes 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期177-183,共7页
This paper investigates how to address the chaos problem in a permanent magnet synchronous generator(PMSG) in a wind turbine system. Predictive control approach is proposed to suppress chaotic behavior and make oper... This paper investigates how to address the chaos problem in a permanent magnet synchronous generator(PMSG) in a wind turbine system. Predictive control approach is proposed to suppress chaotic behavior and make operating stable;the advantage of this method is that it can only be applied to one state of the wind turbine system. The use of the genetic algorithms to estimate the optimal parameter values of the wind turbine leads to maximization of the power generation.Moreover, some simulation results are included to visualize the effectiveness and robustness of the proposed method. 展开更多
关键词 permanent magnet synchronous generator chaotic system genetic algorithm predictive control
原文传递
Two-stage Voltage Closed Loop Control Scheme for Hybrid Excited Synchronous Generator-matrix Converter Generation System 被引量:1
11
作者 SHI Mingming ZHOU Bo +1 位作者 WEI Jiadan MAO Yiran 《中国电机工程学报》 EI CSCD 北大核心 2012年第3期I0001-I0023,共23页
Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power el... Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power electronics systems.This paper investigated a novel generationsystem,which is composed of hybrid excitedsynchronous generator(HESG)and matrix converter(MC),as shown in Fig.1.Owing to the voltage clampcircuit,this structure waived an external DC sourcecommonly used for the excitation for HESG.Thevoltage clamp circuit shared a DC bus with afull-bridge converter and the excitation winding ofHESG is directly connected to the output of thefull-bridge converter achieving a bidirectional currentflow. 展开更多
关键词 matrix converter hybrid excited synchronous generator variable speed constant frequency
原文传递
A Fault Feature Extraction Model in Synchronous Generator under Stator Inter-Turn Short Circuit Based on ACMD and DEO3S 被引量:1
12
作者 Yuling He Shuai Li +1 位作者 Chao Zhang Xiaolong Wang 《Structural Durability & Health Monitoring》 EI 2023年第2期115-130,共16页
This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fa... This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model. 展开更多
关键词 synchronous generator stator inter-turn short circuit vibration signal processing adaptive chirp mode decomposition demodulation energy operator of symmetrical differencing
在线阅读 下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics 被引量:2
13
作者 Masaki Yagami Takahiko Hasegawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2012年第12期762-768,共7页
As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the... As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the generator transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the generator transient stability in the power system with significant PV penetration is assessed by a numerical simulation. In order to assess the impact from various angles, simulation parameters such as levels of PV penetration, variety of power sources (inverter or rotational machine), and existence of LVRT capability are considered. The simulation is performed by using PSCAD/EMTDC software. 展开更多
关键词 High-penetration photovoltaics low-voltage ride-through (LVRT) synchronous generator transient stability.
在线阅读 下载PDF
On linear observers and application to fault detection in synchronous generators
14
作者 Jan Erik STELLET Tobias ROGG 《Control Theory and Technology》 EI CSCD 2014年第4期345-356,共12页
This work introduces an observer structure and highlights its distinct advantages in fault detection and isolation. Its application to the issue of shorted turns detection in synchronous generators is demonstrated. Fo... This work introduces an observer structure and highlights its distinct advantages in fault detection and isolation. Its application to the issue of shorted turns detection in synchronous generators is demonstrated. For the theoretical foundation, the convergence and design of Luenberger-type observers for disturbed linear time-invariant (LTI) single-input single-output (SISO) systems are reviewed with a particular focus on input and output disturbances. As an additional result, a simple observer design for stationary output disturbances that avoids a system order extension, as in classical results, is proposed. 展开更多
关键词 synchronous generators Field winding Fault detection Unknown input observer (UIO) Disturbance observer Residual generation
原文传递
Modelling and Implementation of Multi-source Isolated Microgrid Using Virtual Synchronous Generator Technology
15
作者 CHEN Xing QIAN Shengnan +2 位作者 LI Fei GE Zhaohui CAO Xin 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2021年第5期747-757,共11页
To improve the living standards,economical efficiency and environmental protection of isolated islands,remote areas and other areas with weak electric power facilities construction,a multi-source independent microgrid... To improve the living standards,economical efficiency and environmental protection of isolated islands,remote areas and other areas with weak electric power facilities construction,a multi-source independent microgrid system is studied,including diesel generators,photovoltaic power generation system,wind power generation system and energy storage unit.Meanwhile,in order to realize the voltage and frequency stability control of AC bus of multisource microgrid,the virtual synchronous generator technology is introduced into the energy storage unit,and the charge and discharge control of the energy storage battery are simulated as the control behavior characteristics of synchronous motors,so as to provide damping and inertia support for the microgrid.The operation mode and control principle of each energy subsystem are expounded and analyzed.The algorithm principle of virtual synchronous generator and the control method of energy storage unit are given.Then,the working modes of the microgrid system under different environmental conditions are analyzed,and the multi-source microgrid system simulation model is built based on MATLAB/Simulink.The simulation results show that the microgrid system can run stably under different working modes and the energy storage unit using the virtual synchronous generator technology can provide good voltage and frequency support for the microgrid system.Finally,experiments verify the supporting function of energy storage unit on the voltage and frequency of the microgrid system. 展开更多
关键词 isolated microgrid wind/solar/diesel/storage virtual synchronous generator MODELLING
在线阅读 下载PDF
Transient Stability Analysis of Synchronous Generator in Power System with Renewable Power Sources Installed
16
作者 Masaki Yagami Yoshihiro Ichinohe +2 位作者 Yohichiro Kojima Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2016年第8期400-407,共8页
The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magn... The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated. 展开更多
关键词 Fault ride-through variable speed wind generator PHOTOVOLTAIC synchronous generator transient stability.
在线阅读 下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)
17
作者 Masaki Yagami Seiichiro lshikawa +2 位作者 Yoshihiro Ichinohe Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2015年第7期401-406,共6页
In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ... In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated. 展开更多
关键词 High-penetration photovoltaics LVRT (low-voltage ride-through) synchronous generator transient stability
在线阅读 下载PDF
Problems Related to Excitation Winding Surface Temperature Measurement of a Salient Pole Synchronous Generator in Rotation
18
作者 Zlatko Hanic Mario Vrazic Stjepan Stipetic 《Journal of Energy and Power Engineering》 2012年第5期826-832,共7页
This paper addresses some of the problems related to direct surface temperature measurement of a salient pole synchronous generator excitation winding in rotation. Excitation winding temperature is used for determinin... This paper addresses some of the problems related to direct surface temperature measurement of a salient pole synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the contact DS 18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement of the excitation winding surface conducted in the salient pole synchronous generator in the rotation. 展开更多
关键词 Temperature measurement AC machines synchronous generators excitation winding wireless sensing digital temperature sensors.
在线阅读 下载PDF
Virtual Synchronous Generator Based Current Synchronous Detection Scheme for a Virtual Inertia Emulation in SmartGrids
19
作者 Arvind Parwal Martin Fregelius +7 位作者 Dalmo Cardosa Silva Tatiana Potapenko Johannes Hjalmarsson James Kelly Irina Temiz Janaina Goncalves de Oliveira Cecilia Bostrom Mats Leijon 《Energy and Power Engineering》 2019年第3期99-131,共33页
Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy... Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy demand means that the interest for the integration of renewable energy sources in the existing power system is growing, but such integration poses challenges to the operating stability. Power converters play a major role in the evolution of power system towards SmartGrids, by regulating as virtual synchronous generators. The concept of virtual synchronous generators requires an energy storage system with power converters to emulate virtual inertia similar to the dynamics of traditional synchronous generators. In this paper, a dynamic droop control for the estimation of fundamental reference sources is implemented in the control loop of the converter, including active and reactive power components acting as a mechanical input to the virtual synchronous generator and the virtual excitation controller. An inertia coefficient and a droop coefficient are implemented in the control loop. The proposed controller uses a current synchronous detection scheme to emulate a virtual inertia from the virtual synchronous generators. In this study, a wave energy converter as the power source is used and a power management of virtual synchronous generators to control the frequency deviation and the terminal voltage is implemented. The dynamic control scheme based on a current synchronous detection scheme is presented in detail with a power management control. Finally, we carried out numerical simulations and verified the scheme through the experimental results in a microgrid structure. 展开更多
关键词 Current synchronous Detection Dynamic Droop Control Energy Storage Virtual Inertia Virtual synchronous generator
暂未订购
Adaptive Inertia Control for Virtual Synchronous Generators to Enhance Response Performance of a Wind-solar-storage Combined Power Generation System 被引量:1
20
作者 Haibo Zhang Haoyu Zhu +1 位作者 Zhe Zhang Xianfu Gong 《CSEE Journal of Power and Energy Systems》 2025年第3期1358-1369,共12页
The damage of extreme disasters to a power grid is becoming increasingly severe,and energy storage control technology is emerging as a measure to enhance grid resilience.In this study,a novel adaptive inertia control ... The damage of extreme disasters to a power grid is becoming increasingly severe,and energy storage control technology is emerging as a measure to enhance grid resilience.In this study,a novel adaptive inertia control for virtual synchronous generators is proposed for the control of wind-solar-storage combined power generation systems to form the ability for long-term power supply for load.This technology can not only provide inertia for the system but also dynamically adjust inertia according to frequency variation caused by power disturbance,avoiding rapid rise and drop of frequency in the transient process and increasing damping of a wind-solar-storage combined power generation system when the main network fails.Through low pass filtering of the sampled signal and design of the inertia control law,frequent inertia adjustment caused by measurement noise and random small fluctuation of wind speed can be avoided,and the inertia adjustment amount would not exceed the limit under any large power disturbance.The inertial boundary of the system is discussed according to the primary energy storage capacity and the tolerant power of the inverter.Convergence of a novel adaptive control algorithm is proved.Finally,a simulation model is built on PSCAD/EMTDC platform,and the effectiveness of the proposed control strategy is verified. 展开更多
关键词 Adaptive inertia control energy storage frequency response power oscillation virtual synchronous generator(VSG)
原文传递
上一页 1 2 9 下一页 到第
使用帮助 返回顶部