期刊文献+
共找到3,384篇文章
< 1 2 170 >
每页显示 20 50 100
Dynamic response characteristics of super high-rise buildings subjected to long-period ground motions 被引量:5
1
作者 陈清军 袁伟泽 +1 位作者 李英成 曹丽雅 《Journal of Central South University》 SCIE EI CAS 2013年第5期1341-1353,共13页
Spectrum characteristics of different types of seismic waves and dynamic response characteristics of super high-rise building structures under long-period ground motions were comparatively analyzed. First, the ground ... Spectrum characteristics of different types of seismic waves and dynamic response characteristics of super high-rise building structures under long-period ground motions were comparatively analyzed. First, the ground response wave (named LS-R wave) of a soft soil site with deep deposit, taking long-period bedrock seismic record as input, was calculated by wave propagation method. After that, a TOMAKOMAI station long-period seismic record from the Tokachi-Oki earthquake and conventional E1-Centro wave were also chosen. Spectrum characteristics of these waves were analyzed and compared. Then, a series of shaking table tests were performed on a 1:50 scale super high-rise structural model under these seismic waves. Furthermore, numerical simulation of the prototype structure under these excitations was conducted, and structure damages under different intensive ground motions were discussed. The results show that: 1) Spectrum characteristics of ground response wave are significantly influenced by soft soil site with deep deposit, and the predominant period has an increasing trend. 2) The maximum acceleration amplification factor of the structure under the TOM wave is two times that under the E1-Centro wave; while the maximum displacement response of the structure under the TOM wave is 4.4 times that under the E1-Centro wave. Long-period ground motions show greater influences on displacement responses than acceleration responses for super high-rise building structures. 3) Most inelastic damage occurs at the upper 1/3 part of the super high-rise building when subjected to long-period ground motions. 展开更多
关键词 long-period ground motion super high-rise building shaking table model test numerical simulation spectrumcharacteristic analysis
在线阅读 下载PDF
Effects of high modes on the wind-induced response of super high-rise buildings 被引量:2
2
作者 Feng Ruoqiang Guirong Yan Ge Jinming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第3期427-434,共8页
For super high-rise buildings, the vibration period of the basic mode is several seconds, and it is very close to the period of the fluctuating wind. The damping of super high-rise buildings is low, so super high-rise... For super high-rise buildings, the vibration period of the basic mode is several seconds, and it is very close to the period of the fluctuating wind. The damping of super high-rise buildings is low, so super high-rise buildings are very sensitive to fluctuating wind. The wind load is one of the key loads in the design of super high-rise buildings. It is known that only the basic mode is needed in the wind-response analysis of tall buildings. However, for super high-rise buildings, especially for the acceleration response, because of the frequency amplification of the high modes, the high modes and the mode coupling may need to be considered. Three typical super high-rise projects with the SMPSS in wind tunnel tests and the random vibration theory method were used to analyze the effect of high modes on the wind-induced response. The conclusions can be drawn as follows. First, for the displacement response, the basic mode is dominant, and the high modes can be neglected. Second, for the acceleration response, the high modes and the mode coupling should be considered. Lastly, the strain energy of modes can only give the vibration energy distribution of the high-rise building, and it cannot describe the local wind-induced vibration of high-rise buildings, especially for the top acceleration response. 展开更多
关键词 super high-rise building wind tunnel test mode couple wind-induced response
在线阅读 下载PDF
Discussion on Installation Technology of Horizontal Embedded Glass Curtain Wall in Super High-rise Building
3
作者 CHEN Bing 《外文科技期刊数据库(文摘版)工程技术》 2021年第10期667-671,共8页
This paper introduces the installation technology of horizontal embedded glass curtain wall in super high-rise building from aspects of construction technology and key technology, etc. The technology has the advantage... This paper introduces the installation technology of horizontal embedded glass curtain wall in super high-rise building from aspects of construction technology and key technology, etc. The technology has the advantages of simple installation, high construction precision, high speed, low labor intensity, material saving, low construction cost, good construction quality, saving construction period, good fire-proof and impermeability, etc. It can effectively overcome the difficulties encountered in the construction of traditional glass curtain walls, meet the construction requirements of super-high-rise buildings, and has a wider application range. The application of this technology in the construction of super-high-rise buildings has remarkable technical and economic benefits, and it is worth spreading. 展开更多
关键词 super high-rise building horizontal embedded glass curtain wall rear plate hook embedded parts tu
原文传递
Analysis on Design Points of Generic Cabling System for Super High-rise Buildings
4
作者 ZHUHaiqing 《外文科技期刊数据库(文摘版)工程技术》 2022年第4期022-025,共4页
Integrated wiring system is an important infrastructure in ultra-high-rise buildings. Only by ensuring the rationality of the design of integrated wiring system can the use function of ultra-high-rise buildings be ens... Integrated wiring system is an important infrastructure in ultra-high-rise buildings. Only by ensuring the rationality of the design of integrated wiring system can the use function of ultra-high-rise buildings be ensured. In this paper, the concept of ultra-high-rise building and integrated wiring system is briefly introduced at first, then the importance of integrated wiring system to ultra-high-rise building is clarified, then the design points of integrated wiring system of ultra-high-rise building are analyzed combined with actual projects, and finally the management optimization scheme of integrated wiring system of ultra-high-rise building is discussed. 展开更多
关键词 super high-rise buildings generic cabling system key design points
原文传递
Application of BIM Technology in Construction of Super High-rise Building
5
作者 WUYun ZHANGLiliang 《外文科技期刊数据库(文摘版)工程技术》 2022年第5期040-043,共4页
Deep foundation pit engineering actually refers to the earthwork excavation, support or precipitation engineering of the foundation pit with an excavation depth greater than 5m, where BIM technology can achieve twice ... Deep foundation pit engineering actually refers to the earthwork excavation, support or precipitation engineering of the foundation pit with an excavation depth greater than 5m, where BIM technology can achieve twice the result with half the effort. In addition, the depth of the foundation pit is insufficient, but the surrounding geological environment and the more complex earthwork excavation of underground pipelines can also be used. In recent years, in the process of urban development in China, the utilization rate of underground space has been significantly improved. In the common subway, underground shopping malls and tunnels and other large-scale engineering excavation, using BIM technology is also a very reasonable choice. Based on this, this article studies the application of BIM technology in the construction of deep foundation pit of super high-rise buildings for reference. 展开更多
关键词 BIM technology super high-rise building deep foundation pit
原文传递
Discussion on the Construction of Anti-smoke Construction Technology in Super High-rise Buildings
6
作者 Xiaolong Ruan 《Journal of World Architecture》 2019年第4期1-4,共4页
In recent years with the increasing number of super high-rise buildings and the ever-expanding scale the anti-smoke construction technology has attracted more and more attention.Based on this situation,this paper anal... In recent years with the increasing number of super high-rise buildings and the ever-expanding scale the anti-smoke construction technology has attracted more and more attention.Based on this situation,this paper analyzes the smoke control technology of super high-rise buildings.The paper analyzes the importance of the application of anti-smoke construction technology in super high-rise buildings,analyzes the problems in the construction of smoke control and super high-rise buildings.The anti-smoke construction technology was studied and I hope that it can benefit the application of anti-smoke construction technology in high-rise buildings. 展开更多
关键词 super high-rise building SMOKE control CONSTRUCTION technology Problem and optimization
在线阅读 下载PDF
Design and force analysis of steel truss of intelligent construction machine for super high-rise buildings
7
作者 Zhongyuan Zhang Fankui Zeng +4 位作者 Jiaquan Liu Haiying Guo Yanping Niu Guanghui Du Xinzhao Liu 《Advances in Engineering Innovation》 2025年第3期1-24,共24页
Super high-rise buildings are typically located in bustling urban areas.Due to their considerable height and limited construction space,numerous challenges arise during the construction process.To enhance the safety a... Super high-rise buildings are typically located in bustling urban areas.Due to their considerable height and limited construction space,numerous challenges arise during the construction process.To enhance the safety and efficiency of super highrise building construction,this paper designs an intelligent construction machine steel truss platform suitable for the core tube structure of such buildings.Numerical analyses of the designed steel truss platform were conducted during the construction,jacking,and self-climbing phases.The analysis results indicate that the strength and stiffness of the intelligent construction machine steel truss platform meet the design standards for steel structures,ensuring the overall safety and reliability of the structure.However,stress and deformation are relatively high at the connections between primary and secondary trusses,particularly in the chords and webs,as well as at the joints between truss beams and columns.To facilitate construction and improve structural safety reserves,technical and structural optimization suggestions are proposed based on the analysis results.This study provides valuable insights for the design of similar intelligent construction machine steel truss platforms in engineering projects. 展开更多
关键词 super high-rise buildings steel truss platform numerical analysis
在线阅读 下载PDF
Technical Management and Risk Management Practices for a High-Rise Public Building Project in Guangzhou Nansha Free Trade Zone
8
作者 Fuxuan Lin 《Journal of World Architecture》 2025年第5期82-88,共7页
The construction project of a non-super high-rise public building in Guangzhou’s Nansha Free Trade Zone faces unique challenges.The project established a full-cycle technical management system,encompassing technical ... The construction project of a non-super high-rise public building in Guangzhou’s Nansha Free Trade Zone faces unique challenges.The project established a full-cycle technical management system,encompassing technical management across various sectors and BIM collaboration.Simultaneously,it introduced advanced technical management such as deep foundation pits and core tube construction,along with a risk management system and special weather response strategies.Through these measures,the project achieved numerous significant results,forming a unique management paradigm that offers valuable insights for similar engineering projects. 展开更多
关键词 Nansha Free Trade Zone Non-super high-rise public building Engineering management
在线阅读 下载PDF
Collapse simulation of a super high-rise building subjected to extremely strong earthquakes 被引量:49
9
作者 LU Xiao LU XinZheng +1 位作者 ZHANG WanKai YE LiePing 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第10期2549-2560,共12页
In recent years, super high-rise buildings (>500 m) are developing very quickly and become an important frontier of civil engineering. The collapse resistance of super high-rise buildings subjected to extremely str... In recent years, super high-rise buildings (>500 m) are developing very quickly and become an important frontier of civil engineering. The collapse resistance of super high-rise buildings subjected to extremely strong earthquake is a critical problem that must be intensively studied. This paper builds up a nonlinear finite element model of the tallest building in China, Shang- hai Tower (632 m), and proposes the modeling method and failure criteria for different structural elements. The dynamic char- acters of this building are then analyzed, and the possible failure modes and collapse processes due to earthquakes are pre- dicted, as well as the corresponding collapse mechanism. This work will be helpful in collapse prevention and the seismic design of super high-rise buildings. 展开更多
关键词 super high-rise building collapse simulation extremely strong earthquake finite element method
原文传递
An improved ground motion intensity measure for super high-rise buildings 被引量:10
10
作者 LU Xiao YE LiePing +2 位作者 LU XinZheng LI MengKe MA XiaoWei 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第6期1525-1533,共9页
Ground motion intensity measure (IM) is an important part in performance-based seismic design. A reasonable and efficient IM can make the prediction of the structural seismic responses more accurate. Therefore, a more... Ground motion intensity measure (IM) is an important part in performance-based seismic design. A reasonable and efficient IM can make the prediction of the structural seismic responses more accurate. Therefore, a more reasonable IM for super high-rise buildings is proposed in this paper. This IM takes into account the significant characteristic that higher-order vibration modes play important roles in the seismic response of super high-rise buildings, as well as the advantages of some existing IMs. The key parameter of the proposed IM is calibrated using a series of time-history analyses. The collapse simulations of two super high-rise buildings are used to discuss the suitability of the proposed IM and some other existing IMs. The results indicate that the proposed IM yields a smaller coefficient of variation for the critical collapse status than other existing IMs and performs well in reflecting the contribution of higher-order vibration modes to the structural response. Hence, the proposed IM is more applicable to seismic design for super high-rise buildings than other IMs. 展开更多
关键词 ground motion intensity measure super high-rise building time-history analysis collapse analysis
原文传递
Study on Evacuation Strategy of Commercial High-Rise Building under Fire Based on FDS and Pathfinder
11
作者 Zheng Yan Ying Wang +1 位作者 Longxiao Chao Jian Guo 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第2期1077-1102,共26页
With the development of economy and society and the growth of population,the high-rise and multi-function of commercial buildings have become an international trend.But it also poses huge fire hazards.Most of the exis... With the development of economy and society and the growth of population,the high-rise and multi-function of commercial buildings have become an international trend.But it also poses huge fire hazards.Most of the existing studies’research objects are predominantly high-rise residential buildings,without considering the impact of different functional zones(Standard floor,entertainment zone,office zone,equipment room and so on)and personnel distribution of commercial buildings evacuation.And the influence of using elevators to carry evacuees on the refuge floor on personnel evacuation is rarely studied.In this work,the fire scenario of the Yangtze River InternationalConferenceCenter,a high-rise commercial building,is simulated with the Pyrosim programto get the necessary parameters under various fire scenarios and to calculate the available evacuation time TASET.At the same time,according to the complex functional zone of the commercial high-rise building and the distribution of people in different time periods,a reasonable evacuation strategy is developed and simulated by Pathfinder software.The results indicate that unorganized evacuation will lead individuals to take the erroneous evacuation route,resulting in a vast region of congestion;comprehensive consideration of the time staggering and the reasonable distribution of evacuation routes can significantly improve evacuation efficiency,and the TRSET of night and working hours is 36.6%–55.3%and 49.9%–79.6%of unorganized evacuation,respectively.For the night fire,60%of the people use elevator-refuge floor to evacuate is the optimal strategy;for the fire during working hours,half of the people on standard floors use the elevator to evacuate and people on multifunctional floors evacuate in four batches is the best plan.The results of this study can provide viable solutions and a foundation for analyzing the fire evacuation and safety of big commercial high-rise buildings. 展开更多
关键词 high-rise building fire personnel evacuation refuge floor safety analysis
在线阅读 下载PDF
A Stroke-Limitation AMD Control System with Variable Gain and Limited Area for High-Rise Buildings
12
作者 Zuo-Hua Li Qing-Gui Wu +1 位作者 Jun Teng Chao-Jun Chen 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期865-884,共20页
Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a ... Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a strokelimited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power.To solve this problem,the design approach with variable gain and limited area(VGLA)is proposed in this study.First,the boundary of variable-limited areas is calculated based on the real-time status of the moving mass.The variable gain(VG)expression at the variable limited area is deduced by considering the saturation of AMD stroke.Then,numerical simulations of a stroke-limited AMD control system with VGLA are conducted on a high-rise building structure.These numerical simulations show that the proposed approach has superior strokelimitation performance compared with a stroke-limited AMD control system with a fixed limited area.Finally,the proposed approach is validated through experiments on a four-story steel frame. 展开更多
关键词 high-rise buildings active control stroke limitations variable gain variable limited area
在线阅读 下载PDF
A novel control strategy for reproducing the floor motions of high-rise buildings by earthquake-simulating shake tables
13
作者 Yuteng Cao Zhe Qu Xiaodong Ji 《Earthquake Research Advances》 CSCD 2024年第1期67-75,共9页
To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Tab... To enable the experimental assessment of the seismic performance of full-scale nonstructural elements with multiple engineering parameters(EDPs),a three-layer testbed named Nonstructural Element Simulator on Shake Table(NEST)has been developed.The testbed consists of three consecutive floors of steel structure.The bottom two floors provide a space to accommodate a full-scale room.To fully explore the flexibility of NEST,we propose a novel control strategy to generate the required shake table input time histories for the testbed to track the target floor motions of the buildings of interest with high accuracy.The control strategy contains two parts:an inverse dynamic compensation via simulation of feedback control systems(IDCS)algorithm and an offline iteration procedure based on a refined nonlinear numerical model of the testbed.The key aspects of the control strategy were introduced in this paper.Experimental tests were conducted to simulate the seismic responses of a full-scale office room on the 21^(st)floor of a 42-story high-rise building.The test results show that the proposed control strategy can reproduce the target floor motions of the building of interest with less than 20%errors within the specified frequency range. 展开更多
关键词 Shake table test Nonstructural element high-rise building Open-loop IDCS algorithm Off-line iteration
在线阅读 下载PDF
Fire Safety Problems and Fire Prevention Supervision Strategies of High-rise Buildings
14
作者 LING Yan LIU Lei 《外文科技期刊数据库(文摘版)工程技术》 2021年第12期671-674,共6页
With the further development of economy and society, in order to meet people's living needs, high-rise buildings have been developed to a certain extent. They can save floor area and provide more living space, whi... With the further development of economy and society, in order to meet people's living needs, high-rise buildings have been developed to a certain extent. They can save floor area and provide more living space, which plays a very key role in the process of urban development. However, due to the complex structure of high-rise buildings and the lack of guarantee of safety, fire safety problems may occur, which will not only bring people unnecessary economic losses, but also casualties. Therefore, we must pay attention to this problem and formulate appropriate measures to improve the fire prevention supervision ability. Next, the paper discusses the fire safety problems of high-rise buildings and their fire prevention supervision strategies. 展开更多
关键词 high-rise building fire safety fire prevention supervision
原文传递
Quantitative investigation on collapse margin of steel high-rise buildings subjected to extremely severe earthquakes 被引量:11
15
作者 Lin Xuchuan Mikiko Kato +1 位作者 Zhang Lingxin Masayoshi Nakashima 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第3期445-457,共13页
Reponses of structures subjected to severe earthquakes sometimes significantly surpass what was considered in the design.It is important to investigate the failure mechanism and collapse margin of structures beyond de... Reponses of structures subjected to severe earthquakes sometimes significantly surpass what was considered in the design.It is important to investigate the failure mechanism and collapse margin of structures beyond design,especially for high-rise buildings.In this study,steel high-rise buildings using either square concrete-filled-tube(CFT) columns or steel tube columns are designed.A detailed three-dimensional(3 D) structural model is developed to analyze the seismic behavior of a steel high-rise towards a complete collapse.The effectiveness is verified by both component tests and a full-scale shaking table test.The collapse margin,which is defined as the ratio of PGA between the collapse level to the design major earthquake level(Level 2),is quantified by a series of numerical simulations using incremental dynamic analyses(IDA).The baseline building using CFT columns collapsed with a weak first story mechanism and presented a collapse margin ranging from 10 to 20.The significant variation in the collapse margin was caused by the different characteristics of the input ground motions.The building using equivalent steel columns collapsed earlier due to the significant shortening of the locally buckled columns,exhibiting only 57% of the collapse margin of the baseline building.The influence of reducing the height of the first story was quite significant.The shortened first story not only enlarged the collapse margin by 20%,but also changed the collapse mode. 展开更多
关键词 collapse quantification steel high-rise building numerical models local buckling collapse mechanism
在线阅读 下载PDF
Vibration Control of a High-Rise Building Structure:Theory and Experiment 被引量:6
16
作者 Yuhua Song Wei He +1 位作者 Xiuyu He Zhiji Han 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2021年第4期866-875,共10页
In this study,an innovative solution is developed for vibration suppression of the high-rise building.The infinite dimensional system model has been presented for describing high-rise building structures which have a ... In this study,an innovative solution is developed for vibration suppression of the high-rise building.The infinite dimensional system model has been presented for describing high-rise building structures which have a large inertial load with the help of the Hamilton’s principle.On the basis of this system model and with the use of the Lyapunov’s direct method,a boundary controller is proposed and the closed-loop system is uniformly bounded in the time domain.Finally,by using the Smart Structure laboratory platform which is produced by Quancer,we conduct a set of experiments and find that the designed method is resultful. 展开更多
关键词 Boundary control distributed parameter systems high-rise building structure vibration control
在线阅读 下载PDF
Multi-hazard performance assessment of a transfer-plate high-rise building 被引量:3
17
作者 Xiangming Zhou 徐幼麟 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第4期371-382,共12页
Many urban areas are located in regions of moderate seismicity and are subjected to strong wind. Buildings in these regions are often designed without seismic provisions. As a result, in the event of an earthquake, th... Many urban areas are located in regions of moderate seismicity and are subjected to strong wind. Buildings in these regions are often designed without seismic provisions. As a result, in the event of an earthquake, the potential for damage and loss of lives may not be known. In this paper, the performance of a typical high-rise building with a thick transfer plate (TP), which is one type of building structure commonly found in Hong Kong, is assessed against both earthquake and wind hazards. Seismic- and wind-resistant performance objectives are first reviewed based on relevant codes and design guidelines for high-rise buildings. After a brief introduction of wind-resistant design of the building, various methodologies, including equivalent static load analysis (ESLA), response spectrum analysis (RSA), pushover analysis (POA), linear and nonlinear time-history analysis (LTHA and NTHA), are employed to assess the seismic performance of the building when subjected to frequent earthquakes, design based earthquakes and maximum credible earthquakes. The effects of design wind and seismic action with a common 50-year return period are also compared. The results indicate that most performance objectives can be satisfied by the building, but there are some objectives, such as inter-story drift ratio, that cannot be achieved when subjected to the frequent earthquakes. It is concluded that in addition to wind, seismic action may need to be explicitly considered in the design of buildings in regions of moderate seismicity. 展开更多
关键词 multi-hazard performance-based design SEISMIC moderate seismicity WIND pushover analysis transferplate high-rise building
在线阅读 下载PDF
Safety analysis of optimal outriggers location in high-rise building structures 被引量:3
18
作者 ZHANG Jiet ZHANG Zhong-xian +2 位作者 ZHAO Wen-guang ZHU Hong-ping ZHOU Chun-sheng 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第2期264-269,共6页
This paper presents the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions betwe... This paper presents the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions between outriggers and core wall as well as the finite rigidities of outriggers are also considered. One case study was carried out to analyze the horizontal top deflection and the mutation of the restraining moments caused by the variation of outrigger location. The results showed that the method adopted in the paper is simple and reasonable. Some conclusions are valuable to the safety design of high-rise building structures. 展开更多
关键词 high-rise building Frame-core structure OUTRIGGER Internal force mutation Horizontal top deflection Safety
在线阅读 下载PDF
Optimization of Grouping Evacuation Strategy in High-rise Building Fires Based on Graph Theory and Computational Experiments 被引量:5
19
作者 Yuling Hu Xiwei Liu 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2018年第6期1104-1112,共9页
It is difficult to rescue people from outside, and emergency evacuation is still a main measure to decrease casualties in high-rise building fires. To improve evacuation efficiency, a valid and easily manipulated grou... It is difficult to rescue people from outside, and emergency evacuation is still a main measure to decrease casualties in high-rise building fires. To improve evacuation efficiency, a valid and easily manipulated grouping evacuation strategy is proposed. Occupants escape in groups according to the shortest evacuation route is determined by graph theory. In order to evaluate and find the optimal grouping, computational experiments are performed to design and simulate the evacuation processes. A case study shown the application in detail and quantitative research conclusions is obtained. The thoughts and approaches of this study can be used to guide actual high-rise building evacuation processes in future. 展开更多
关键词 Computational experiments grouping evacuation graph theory high-rise building fire management strategies
在线阅读 下载PDF
A review on research of fire dynamics in high-rise buildings 被引量:3
20
作者 Jinhua Sun Longhua Hu Ying Zhang 《Theoretical & Applied Mechanics Letters》 CAS 2013年第4期1-13,共13页
Since serious fire occurred frequently in recent years, fire safety of high-rise building has attracted extensive attention. A National Basic Research Program (973 program) of China has been set up by Ministry of Sc... Since serious fire occurred frequently in recent years, fire safety of high-rise building has attracted extensive attention. A National Basic Research Program (973 program) of China has been set up by Ministry of Science and Technology (MOST) of China in 2012 to meet the research requirements of fire safety in high-rise buildings. This paper reviews the current state of art of research on fire dynamics of high-rise buildings, including the up-to-date progress of this project. The following three subjects on fire dynamics of high-rise buildings are addressed in this review: the ejected flame and fire plume behavior over facade out of the compartment window, the flame spread behavior over facade thermal insulation materiMs, and the buoyancy-driven smoke transportation characteristics along long vertical channels in high-rise buildings. Prospective future works are discussed and summarized. 展开更多
关键词 high-rise building fire dynamics facade flame fire spread smoke transportation
在线阅读 下载PDF
上一页 1 2 170 下一页 到第
使用帮助 返回顶部