Solar evaporation is recognized as a prospective technique to produce freshwater from non-drinkable water using inexhaustible solar energy.However,it remains a challenge to fabricate low-cost solar evaporators with ob...Solar evaporation is recognized as a prospective technique to produce freshwater from non-drinkable water using inexhaustible solar energy.However,it remains a challenge to fabricate low-cost solar evaporators with obviously reduced water evaporation enthalpy to achieve high evaporation rates.Herein,N,O dual-doped carbon foam(NCF)is fabricated from the lowtemperature carbonization of poly(ethylene terephthalate)(PET)waste by melamine/molten salts at 340℃.During carbonization,melamine reacts with carboxylic acids of PET degradation products to yield a crosslinking network,and then molten salts catalyze the decarboxylation and dehydration to construct a stable framework.Owing to rich N,O-containing groups,3D interconnected pores,super-hydrophilicity,and ultra-low thermal conductivity(0.0599 W m^(−1) K^(−1)),NCF not only achieves high light absorbance(ca.99%)and solar-to-thermal conversion,but also promotes the formation of water cluster to reduce water evaporation enthalpy by ca.37%.Consequently,NCF exhibits a high evaporation rate(2.4 kg m^(−2) h^(−1)),surpassing the-state-of-the-art solar evaporators,and presents good antiacid/basic abilities,long-term salt-resistance,and self-cleaning ability.Importantly,a large-scale NCF-based outdoor solar desalination device is developed to produce freshwater.The daily freshwater production amount per unit area(6.3 kg)meets the two adults’daily water consumption.The trash-to-treasure strategy will give impetus to the development of low-cost,advanced solar evaporators from waste plastics for addressing the global freshwater shortage.展开更多
Steam generator tube rupture(SGTR) accident is an important scenario needed to be considered in the safety analysis of lead-based fast reactors. When the steam generator tube breaks close to the main pump, water vapor...Steam generator tube rupture(SGTR) accident is an important scenario needed to be considered in the safety analysis of lead-based fast reactors. When the steam generator tube breaks close to the main pump, water vapor will enter the reactor core, resulting in a two-phase flow of heavy liquid metal and water vapor in fuel assemblies. The thermal-hydraulic problems caused by the SGTR accident may seriously threaten reactor core's safety performance. In this paper, the open-source CFD calculation software OpenFOAM was used to encapsulate the improved Euler method into the self-developed solver LBEsteamEulerFoam. By changing different heating boundary conditions and inlet coolant types, the two-phase flow in the fuel assembly with different inlet gas content was simulated under various accident conditions. The calculation results show that the water vapor may accumulate in edge and corner channels. With the increase in inlet water vapor content, outlet coolant velocity increases gradually. When the inlet water vapor content is more than 15%, the outlet coolant temperature rises sharply with strong temperature fluctuation. When the inlet water vapor content is in the range of 5–20%, the upper part of the fuel assembly will gradually accumulate to form large bubbles. Compared with the VOF method, Euler method has higher computational efficiency. However, Euler method may cause an underestimation of the void fraction, so it still needs to be calibrated with future experimental data of the two-phase flow in fuel assembly.展开更多
The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics...The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics behavior,so the transient analysis of the steam generator should firstly solve their mathematical models.For determination of dynamic behavior and design and testing of the control system, a nonlinear math model is developed using one dimensional conservation equations of mass,momentum and energy of primary and secondary sides of the steam generator. The nonlinear model is verified with standard power plant data available in the references, then the steady states and transient calculations are performed for full power to 5% power reactor operation of the steam generator of Chinese Qinshan Nuclear Power Plant.展开更多
This paper presents a novel method to solve old problem of water level control system of pressurized water reactor (PWR) steam generator (SG) of nuclear power plant (NPP) .The level control system of SG plays an impo...This paper presents a novel method to solve old problem of water level control system of pressurized water reactor (PWR) steam generator (SG) of nuclear power plant (NPP) .The level control system of SG plays an important role which effects the reliablity,safty,cost of SG and its mathematical models have been solved.A model of the conventional controller is presented and the existing problems are discussed. A novel rule based realtime control technique is designed with a computerized water level control (CWLC) system for SG of PWR NPP.The performance of this is evaluated for full power reactor operating conditions by applying different transient conditions of SG′s data of Qinshan Nuclear Power Plant (QNPP).展开更多
Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level ...Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level controlling, influence factors on the drum level sloshing were investigated. Firstly, drum sub-modules were developed using the method of modularization modeling, and then the model of drum level sloshing was set up as well. Experiments were carried out on the experimental rig, and the model was validated using the obtained experimental results. Dynamic simulation was made based on the model to get a 3-D graph of drum level sloshing, which shows a vivid procedure of drum level sloshing. The effect of feed-water flow rate, main-steam flow rate and heating quantity on the drum level sloshing was analyzed. The simulation results indicate that the signals with frequency higher than 0.05 Hz are that of drum level sloshing, the signals with frequency of 0.0-0.05 Hz are that of drum level trendy and "false water level", and variation of the feed-water flow rates, main-steam flow rates and heating quantities can change the frequency of drum level sloshing, i.e., the frequency of sloshing increases with the increase of feed-water flow rate, or the decrease of the main-steam flow rate and the heating quantity. This research work is fundamental to improve signal-to-noise ratio of drum level signal and precise controlling of drum level.展开更多
Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps, a mathematical model...Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps, a mathematical model of marine steam generator feedwater control system was developed which includes mathematical models of two steam generators and parallel turbine-driven feed pumps as well as mathematical models of feedwater pipes and feed regulating valves. The operating condition points of the parallel ttu-bine-driven feed pumps were calculated by the Chebyshev curve fit method. A water level controller for the steam generator and a rotary speed controller for the turbine-driven feed pumps were also included in the model. The accuracy of the mathematical models and their controllers was verified by comparing their results with those from a simulator.展开更多
The once-through steam generator (OTSG) in concentric annuli tube is a new type of steam generator which applies double side to transfer heat. The heat flux between the water of centric tube, outside annuli tube and t...The once-through steam generator (OTSG) in concentric annuli tube is a new type of steam generator which applies double side to transfer heat. The heat flux between the water of centric tube, outside annuli tube and that of annulus channel is assumed to be equal, and then the steam generator’s model is built by lumped parameters with moving boundary. In the basis of the built model, static and dynamic characteristics are analyzed. The static characteristics are proved by experiment results in a 19-tube once-through steam generator of Babcock & Wilcox. The characteristics that the lengths of three regions (subcooled region, nucleate boiling region, superheat region) change with power can be explained by theory analysis. The dynamic characteristics accord with the heat and hydraulics and the results of analysis according to the mechanism.展开更多
Steam generator passive heat removal system(SG-PHRS) is used as a passively safe mode to provide decay heat removal in some advanced pressurized water reactors. Due to the structure characteristics of steam generator(...Steam generator passive heat removal system(SG-PHRS) is used as a passively safe mode to provide decay heat removal in some advanced pressurized water reactors. Due to the structure characteristics of steam generator(SG), there are two natural circulation loops coupling in SG-PHRS in case of a safety-related event. The existing natural circulation scaling criteria could be used to simulate the natural circulation inside SG. Two-phase natural circulation loop is studied carefully, and the dominant effects of SG on behaviors of natural circulation in passive heat removal system are presented. Based on the understanding of SG-PHRS operation, system pressure transient scaling and two-phase natural circulation scaling are analyzed by establishing the relevant continuity,integral momentum and energy equations in one-dimensional area-averaged forms. With modified equations,similarity criteria for SG-PHRS are obtained for engineering application. In addition, equal height simulation and reduced height simulation are studied.展开更多
The decommissioning of nuclear power plants is in the Slovak Republic an actual issue. In 2015 started the second decommissioning stage of nuclear power plant V1 in Jaslovské Bohunice. This stage involves the dis...The decommissioning of nuclear power plants is in the Slovak Republic an actual issue. In 2015 started the second decommissioning stage of nuclear power plant V1 in Jaslovské Bohunice. This stage involves the dismantling and segmentation of activated (reactor pressure vessel, reactor internals) and contaminated parts (steam generators, pressurizer). From this reason it is necessary to investigate the radiation situation in the vicinity of the component to be cut. The presented results show that during remote dismantling the exposure is small (compared with the fragmentation tasks). Moreover, when the pre-dismantling decontamination with decontamination factor of 100 is applied, the total collective effective dose is below the yearly limit of 20 mSv for workers.展开更多
This paper assessed the benefit of the in-situ pressure test to support steam generator tube integrity assessment and reviewed a conservatism of currently applied structural integrity assessment methodology against de...This paper assessed the benefit of the in-situ pressure test to support steam generator tube integrity assessment and reviewed a conservatism of currently applied structural integrity assessment methodology against defected tubes. According to the steam generator program requirement, condition monitoring assessment was performed to the all detected flaws. For condition monitoring assessments, the limiting structural integrity requirement should be demonstrated for all detected degraded tubes at a probability of at least 0.95 at 50% confidence. Some flaws were slightly exceeded the structural integrity threshold values of the condition monitoring performance limits using analytical method. As a direct evaluation of tube integrity with degraded tubes, in-situ pressure testing performed on some selected flaws and passed all proof and leakage test criteria with no leakage. From this pressure testing, the authors have verified that degraded tubes met a specified value containing a defined safety margins. Also, the authors have confirmed that existing structural assessment methodology has enough margins to retain integrity of steam generator tubes.展开更多
A solar steam generator(SSG)is an effective method for solving water shortages and protecting the environment,but its evaporation rate remains limited.Herein,Ga@EOG/PVA aerogel-based SSG with excellent photothermal se...A solar steam generator(SSG)is an effective method for solving water shortages and protecting the environment,but its evaporation rate remains limited.Herein,Ga@EOG/PVA aerogel-based SSG with excellent photothermal seawater purification capabilities was prepared using liquid metal gallium(Ga),edge oxidized graphene(EOG),and polyvinyl alcohol(PVA).The‘‘nut-cake-like''structure formed by electrochemical oxidation of EOG encapsulated Ga nanoparticles enhances light absorption and heat conversion efficiency through multiple light scattering and surface plasmon resonance.Furthermore,the vertical pore structure of the aerogel mimics the xylem conduit in tree trunks,allowing rapid transmission of heat and water,thus increasing its evaporation capacity.Based on these attributes,the SSG demonstrated a light absorption rate of 98.2%and an evaporation rate of 5.13 kg.m^(-2).h^(-1)under one-sun illumination,surpassing previously reported values in the literature.Moreover,the SSG effectively treated heavy metal salts,organic dyes,wastewaters,and acidic or alkaline solutions.These findings highlight the potential effectiveness of the prepared aerogel for numerous of environmental remediation applications,especially in ensuring high water quality and safety for human consumption.展开更多
A 10MW High Temperature Gas Cooled Reactor (HTR-10) designed by the Institute of Nuclear Energy Technology (INET) is now being constructed. The steam generator (SG) in the HTR-10 is one of the most important component...A 10MW High Temperature Gas Cooled Reactor (HTR-10) designed by the Institute of Nuclear Energy Technology (INET) is now being constructed. The steam generator (SG) in the HTR-10 is one of the most important components for reactor safety. The thermal-hydraulic performance of the SG was investigated. A full scale HTR-10 Steam Generator Two Tube Engineering Model Test Facility (SGTM-10) was installed and tested at INET. This paper describes the SGTM-10 thermal hydraulic experimental system in detail. The SGTM-10 simulates the actual thermal and structural parameters of the HTR-10. The SGTM-10 includes three separated loops: the primary helium loop, the secondary water loop, and the tertiary cooling water loop. Two parallel tubes are arranged in the test assembly. The main experimental equipment is shown in the paper. Expermental results are given illustrating the effects of the outlet pressures, the heating power, and the inlet subcooling.展开更多
Steam generator is optimized by applying entransy dissipation extremum principle and constructal theory and adopting analyti-cal method.The obtained results show that the optimal spacing between adjacent tubes,the mas...Steam generator is optimized by applying entransy dissipation extremum principle and constructal theory and adopting analyti-cal method.The obtained results show that the optimal spacing between adjacent tubes,the mass flow rate of gas and the maximum entransy dissipation rate all depend on the dimensionless diameter of one tube,the dimensionless pressure difference number and the dimensionless length of flow channel of gas.Besides the three dimensionless groups,the optimal numbers of riser tubes and downcomer tubes and their summation all depend on the dimensionless height of one tube.The maximum entransy dissipation rate increases as the pressure difference that drives the gas flowing increases,and as the diameter of one tube and the length of flow channel both decrease.The mean heat flux in the heat transfer process of hot gas grows greatly,and the performance of the system is improved.Compared with the optimal construct with heat transfer rate maximization,the optimal construct with entransy dissipation rate maximization can improved the heat transfer effect of the steam generator more.展开更多
Graphite dust has an important effect on the safety of high-temperature gas-cooled reactors(HTR).The flow field in the steam generator was studied by the computational fluid dynamics(CFD) method,with the results i...Graphite dust has an important effect on the safety of high-temperature gas-cooled reactors(HTR).The flow field in the steam generator was studied by the computational fluid dynamics(CFD) method,with the results indicating that the friction velocity in the windward and the leeward of the heat transfer tubes is relatively low and is higher at the sides.Further analysis of the resuspension of graphite dust indicates that the resuspension fraction reaches nearly zero for particles with a diameter less than 1 μm,whereas it will increases as the helium velocity in the steam generator increases for particle size larger than 1 μm.Moreover,the resuspension fraction increases as the particle size increases.The results also indicate that resuspension of the particles with sizes larger than 1 μm exhibited obvious differences in different parts of the steam generator.展开更多
Many heat transfer tubes are distributed on the tube plates of a steam generator that requires periodic inspection by robots.Existing inspection robots are usually involved in issues:Robots with manipulators need comp...Many heat transfer tubes are distributed on the tube plates of a steam generator that requires periodic inspection by robots.Existing inspection robots are usually involved in issues:Robots with manipulators need complicated installation due to their fixed base;tube mobile robots suffer from low running efficiency because of their structural restricts.Since there are thousands of tubes to be checked,task planning is essential to guarantee the precise,orderly,and efficient inspection process.Most in-service robots check the task tubes using row-by-row and column-bycolumn planning.This leads to unnecessary inspections,resulting in a long shutdown and affecting the regular operation of a nuclear power plant.Therefore,this paper introduces the structure and control system of a dexterous robot and proposes a task planning method.This method proceeds into three steps:task allocation,base position search,and sequence planning.To allocate the task regions,this method calculates the tool work matrix and proposes a criterion to evaluate a sub-region.And then all tasks contained in the sub-region are considered globally to search the base positions.Lastly,we apply an improved ant colony algorithm for base sequence planning and determine the inspection orders according to the planned path.We validated the optimized algorithm by conducting task planning experiments using our robot on a tube sheet.The results show that the proposed method can accomplish full task coverage with few repetitive or redundant inspections and it increases the efficiency by 33.31% compared to the traditional planning algorithms.展开更多
The operation of complex systems can drift away from the initial design conditions,due to environmental condi-tions,equipment wear or specific restrictions.Steam generators are complex equipment and their proper opera...The operation of complex systems can drift away from the initial design conditions,due to environmental condi-tions,equipment wear or specific restrictions.Steam generators are complex equipment and their proper opera-tion relies on the identification of their most relevant parameters.An approach to rank the operational parameters of a subcritical steam generator of an actual 360 MW power plant is presented.An Artificial Neural Network-ANN delivers a model to estimate the steam generator efficiency,electric power generation and flue gas outlet temperature as a function of seven input parameters.The ANN is trained with a two-year long database,with training errors of 0.2015 and 0.2741(mean absolute and square error)and validation errors of 0.32%and 2.350(mean percent and square error).That ANN model is explored by means of a combination of situations proposed by a Design of Experiment-DoE approach.All seven controlled parameters showed to be relevant to express both steam generator efficiency and electric power generation,while primary air flow rate and speed of the dynamic classifier can be neglected to calculate flue gas temperature as they are not statistically significant.DoE also shows the prominence of the primary air pressure in respect to the steam generator efficiency,electric power generation and the coal mass flow rate for the calculation of the flue gas outlet temperature.The ANN and DoE combined methodology shows to be promising to enhance complex system efficiency and helpful whenever a biased behavior must be brought back to stable operation.展开更多
GP algorithm of correlation dimension computation is ameliorated which overcomes the shortage of traditional one. Improved process of GP algorithm takes the influence of temporal correlative pairs of points on correla...GP algorithm of correlation dimension computation is ameliorated which overcomes the shortage of traditional one. Improved process of GP algorithm takes the influence of temporal correlative pairs of points on correlation dimension into account and promotes the computational efficiency prominently. Iterative SVD method is applied to remove the influence of noise on the result of correlation dimension. The faults of steam flow turbulence and oil film disturbance which occur in 600 MW Steam Turbine Generator are analyzed and whose correlation dimensions are computed. More distinct quantitative index than FFT is gained to distinguish two faults and it’s of little importance to apply correlation dimension to study the influence of various factors on steam flow turbulence fault for nonexistence of convergent floor in correlation integral curve, which presents a new way to learn the operational function of large capacity steam turbine generator and carry out comprehensive condition monitoring.展开更多
In the scenario of a steam generator tube rupture accident in a lead-cooled fast reactor,secondary circuit subcooled water under high pressure is injected into an ordinary-pressure primary vessel,where a molten lead-b...In the scenario of a steam generator tube rupture accident in a lead-cooled fast reactor,secondary circuit subcooled water under high pressure is injected into an ordinary-pressure primary vessel,where a molten lead-based alloy(typically pure lead or lead-bismuth eutectic(LBE))is used as the coolant.To clarify the pressure build-up characteristics under water-jet injection,this study conducted several experiments by injecting pressurized water into a molten LBE pool at Sun Yat-sen University.To obtain a further understanding,several new experimental parameters were adopted,including the melt temperature,water subcooling,injection pressure,injection duration,and nozzle diameter.Through detailed analyses,it was found that the pressure and temperature during the water-melt interaction exhibited a consistent variation trend with our previous water-droplet injection mode LBE experiment.Similarly,the existence of a steam explosion was confirmed,which typically results in a much stronger pressure build-up.For the non-explosion cases,increasing the injection pressure,melt-pool temperature,nozzle diameter,and water subcooling promoted pressure build-up in the melt pool.However,a limited enhancement effect was observed when increasing the injection duration,which may be owing to the continually rising pressure in the interaction vessel or the isolation effect of the generated steam cavity.Regardless of whether a steam explosion occurred,the calculated mechanical and kinetic energy conversion efficiencies of the melt were relatively small(not exceeding 4.1%and 0.7%,respectively).Moreover,the range of the conversion efficiency was similar to that of previous water-droplet experiments,although the upper limit of the jet mode was slightly lower.展开更多
In complex systems,there is a kind of parameters having only a minor impact on the outputs in most cases,but their accurate values are still critical for the operation of systems.In this paper,the authors focus on the...In complex systems,there is a kind of parameters having only a minor impact on the outputs in most cases,but their accurate values are still critical for the operation of systems.In this paper,the authors focus on the identification of these weak influence parameters in the complex systems and propose a identification model based on the parameter recursion.As an application,three parameters of the steam generator are identified,that is,the valve opening,the valve CV value,and the reference water level,in which the valve opening and the reference water level are weak influence parameters under most operating conditions.Numerical simulation results show that,in comparison with the multi-layer perceptron(MLP),the identification error rate is decreased.Actually,the average identification error rate for the valve opening decreases by 0.96%,for the valve CV decreases by 0.002%,and for the reference water level decreases by 12%after one recursion.After two recursions,the average identification error rate for the valve opening decreases by 11.07%,for the valve CV decreases by 2.601%,and for the reference water level decreases by 95.79%.This method can help to improve the control of the steam generator.展开更多
Harvesting solar energy in an effective manner for steam and electricity generation is a promising technique to simultaneously cope with the energy and water crises.However,the construction of efficient and easy scale...Harvesting solar energy in an effective manner for steam and electricity generation is a promising technique to simultaneously cope with the energy and water crises.However,the construction of efficient and easy scale-up photothermal materials for steam and electricity cogeneration remains challenging.Herein,we report a facile and cost-effective strategy to prepare MnO_(2)-decorated cotton cloth(MCx).The wide adsorption spectrum and excellent photothermal conversion ability of the in situ-formed MnO_(2)nanoparticles make the MCx to be advanced photothermal materials.Consequently,the hybrid device integrated with MCx as the photothermal layer and the thermoelectric(TE)module for electricity power conversion exhibits an extremely high evaporation rate of 2.24 kg m^(−2)h^(−1)under 1 kW m^(−2)irradiation,which is ranked among the most powerful solar evaporators.More importantly,during solar evaporation,the hybrid device produces an open-circuit voltage of 0.3 V and a power output of 1.6 W m^(−2)under 3 Sun irradiation,and outperforms most of the previously reported solar-driven electricity generation devices.Therefore,the integrated device with synergistic solar-thermal utilization opens up a green way toward simultaneous solar vapor and electric power generation in remote and resource-constrained areas.展开更多
基金supported by National Natural Science Foundation of China(No.51903099 and 51991353)100 Talents Program of Hubei Provincial Government,Huazhong University of Science and Technology(No.3004013134 and 2021XXJS036)+1 种基金the Innovation and Talent Recruitment Base of New Energy Chemistry and Device(No.B21003)the Open Research Fund of State Key Laboratory of Polymer Physics and Chemistry,Changchun Institute of Applied Chemistry,Chinese Academy of Sciences.
文摘Solar evaporation is recognized as a prospective technique to produce freshwater from non-drinkable water using inexhaustible solar energy.However,it remains a challenge to fabricate low-cost solar evaporators with obviously reduced water evaporation enthalpy to achieve high evaporation rates.Herein,N,O dual-doped carbon foam(NCF)is fabricated from the lowtemperature carbonization of poly(ethylene terephthalate)(PET)waste by melamine/molten salts at 340℃.During carbonization,melamine reacts with carboxylic acids of PET degradation products to yield a crosslinking network,and then molten salts catalyze the decarboxylation and dehydration to construct a stable framework.Owing to rich N,O-containing groups,3D interconnected pores,super-hydrophilicity,and ultra-low thermal conductivity(0.0599 W m^(−1) K^(−1)),NCF not only achieves high light absorbance(ca.99%)and solar-to-thermal conversion,but also promotes the formation of water cluster to reduce water evaporation enthalpy by ca.37%.Consequently,NCF exhibits a high evaporation rate(2.4 kg m^(−2) h^(−1)),surpassing the-state-of-the-art solar evaporators,and presents good antiacid/basic abilities,long-term salt-resistance,and self-cleaning ability.Importantly,a large-scale NCF-based outdoor solar desalination device is developed to produce freshwater.The daily freshwater production amount per unit area(6.3 kg)meets the two adults’daily water consumption.The trash-to-treasure strategy will give impetus to the development of low-cost,advanced solar evaporators from waste plastics for addressing the global freshwater shortage.
基金supported partly by the Ministry of Science and Technology of the People's Republic of China (No. 2020YFB1902100)the Shanghai Municipal Commission of Economy and Informatization (No. GYQJ-2018-2-02)。
文摘Steam generator tube rupture(SGTR) accident is an important scenario needed to be considered in the safety analysis of lead-based fast reactors. When the steam generator tube breaks close to the main pump, water vapor will enter the reactor core, resulting in a two-phase flow of heavy liquid metal and water vapor in fuel assemblies. The thermal-hydraulic problems caused by the SGTR accident may seriously threaten reactor core's safety performance. In this paper, the open-source CFD calculation software OpenFOAM was used to encapsulate the improved Euler method into the self-developed solver LBEsteamEulerFoam. By changing different heating boundary conditions and inlet coolant types, the two-phase flow in the fuel assembly with different inlet gas content was simulated under various accident conditions. The calculation results show that the water vapor may accumulate in edge and corner channels. With the increase in inlet water vapor content, outlet coolant velocity increases gradually. When the inlet water vapor content is more than 15%, the outlet coolant temperature rises sharply with strong temperature fluctuation. When the inlet water vapor content is in the range of 5–20%, the upper part of the fuel assembly will gradually accumulate to form large bubbles. Compared with the VOF method, Euler method has higher computational efficiency. However, Euler method may cause an underestimation of the void fraction, so it still needs to be calibrated with future experimental data of the two-phase flow in fuel assembly.
文摘The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics behavior,so the transient analysis of the steam generator should firstly solve their mathematical models.For determination of dynamic behavior and design and testing of the control system, a nonlinear math model is developed using one dimensional conservation equations of mass,momentum and energy of primary and secondary sides of the steam generator. The nonlinear model is verified with standard power plant data available in the references, then the steady states and transient calculations are performed for full power to 5% power reactor operation of the steam generator of Chinese Qinshan Nuclear Power Plant.
文摘This paper presents a novel method to solve old problem of water level control system of pressurized water reactor (PWR) steam generator (SG) of nuclear power plant (NPP) .The level control system of SG plays an important role which effects the reliablity,safty,cost of SG and its mathematical models have been solved.A model of the conventional controller is presented and the existing problems are discussed. A novel rule based realtime control technique is designed with a computerized water level control (CWLC) system for SG of PWR NPP.The performance of this is evaluated for full power reactor operating conditions by applying different transient conditions of SG′s data of Qinshan Nuclear Power Plant (QNPP).
基金Project(51276023) supported by the National Natural Science Foundation of ChinaProject(09k069) supported by the Open Project Funded by Universities Innovation Platform, Hunan Province, ChinaProject(2011GK311) supported by the Office of Science and Technology of Hunan Province, China
文摘Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level controlling, influence factors on the drum level sloshing were investigated. Firstly, drum sub-modules were developed using the method of modularization modeling, and then the model of drum level sloshing was set up as well. Experiments were carried out on the experimental rig, and the model was validated using the obtained experimental results. Dynamic simulation was made based on the model to get a 3-D graph of drum level sloshing, which shows a vivid procedure of drum level sloshing. The effect of feed-water flow rate, main-steam flow rate and heating quantity on the drum level sloshing was analyzed. The simulation results indicate that the signals with frequency higher than 0.05 Hz are that of drum level sloshing, the signals with frequency of 0.0-0.05 Hz are that of drum level trendy and "false water level", and variation of the feed-water flow rates, main-steam flow rates and heating quantities can change the frequency of drum level sloshing, i.e., the frequency of sloshing increases with the increase of feed-water flow rate, or the decrease of the main-steam flow rate and the heating quantity. This research work is fundamental to improve signal-to-noise ratio of drum level signal and precise controlling of drum level.
文摘Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps, a mathematical model of marine steam generator feedwater control system was developed which includes mathematical models of two steam generators and parallel turbine-driven feed pumps as well as mathematical models of feedwater pipes and feed regulating valves. The operating condition points of the parallel ttu-bine-driven feed pumps were calculated by the Chebyshev curve fit method. A water level controller for the steam generator and a rotary speed controller for the turbine-driven feed pumps were also included in the model. The accuracy of the mathematical models and their controllers was verified by comparing their results with those from a simulator.
文摘The once-through steam generator (OTSG) in concentric annuli tube is a new type of steam generator which applies double side to transfer heat. The heat flux between the water of centric tube, outside annuli tube and that of annulus channel is assumed to be equal, and then the steam generator’s model is built by lumped parameters with moving boundary. In the basis of the built model, static and dynamic characteristics are analyzed. The static characteristics are proved by experiment results in a 19-tube once-through steam generator of Babcock & Wilcox. The characteristics that the lengths of three regions (subcooled region, nucleate boiling region, superheat region) change with power can be explained by theory analysis. The dynamic characteristics accord with the heat and hydraulics and the results of analysis according to the mechanism.
基金the National Science and TechnologyMajor Project of China(No.2011ZX06004-008)
文摘Steam generator passive heat removal system(SG-PHRS) is used as a passively safe mode to provide decay heat removal in some advanced pressurized water reactors. Due to the structure characteristics of steam generator(SG), there are two natural circulation loops coupling in SG-PHRS in case of a safety-related event. The existing natural circulation scaling criteria could be used to simulate the natural circulation inside SG. Two-phase natural circulation loop is studied carefully, and the dominant effects of SG on behaviors of natural circulation in passive heat removal system are presented. Based on the understanding of SG-PHRS operation, system pressure transient scaling and two-phase natural circulation scaling are analyzed by establishing the relevant continuity,integral momentum and energy equations in one-dimensional area-averaged forms. With modified equations,similarity criteria for SG-PHRS are obtained for engineering application. In addition, equal height simulation and reduced height simulation are studied.
文摘The decommissioning of nuclear power plants is in the Slovak Republic an actual issue. In 2015 started the second decommissioning stage of nuclear power plant V1 in Jaslovské Bohunice. This stage involves the dismantling and segmentation of activated (reactor pressure vessel, reactor internals) and contaminated parts (steam generators, pressurizer). From this reason it is necessary to investigate the radiation situation in the vicinity of the component to be cut. The presented results show that during remote dismantling the exposure is small (compared with the fragmentation tasks). Moreover, when the pre-dismantling decontamination with decontamination factor of 100 is applied, the total collective effective dose is below the yearly limit of 20 mSv for workers.
文摘This paper assessed the benefit of the in-situ pressure test to support steam generator tube integrity assessment and reviewed a conservatism of currently applied structural integrity assessment methodology against defected tubes. According to the steam generator program requirement, condition monitoring assessment was performed to the all detected flaws. For condition monitoring assessments, the limiting structural integrity requirement should be demonstrated for all detected degraded tubes at a probability of at least 0.95 at 50% confidence. Some flaws were slightly exceeded the structural integrity threshold values of the condition monitoring performance limits using analytical method. As a direct evaluation of tube integrity with degraded tubes, in-situ pressure testing performed on some selected flaws and passed all proof and leakage test criteria with no leakage. From this pressure testing, the authors have verified that degraded tubes met a specified value containing a defined safety margins. Also, the authors have confirmed that existing structural assessment methodology has enough margins to retain integrity of steam generator tubes.
基金financially supported by the National Natural Science Foundation of China(No.52403116)the Opening Project of State Key Laboratory of Polymer Materials Engineering(Sichuan University)(No.sklpme2024-1-27)+2 种基金Sichuan Science and Technology Program(No.MZGC20240046)the Science Foundation of Sichuan Province(No.2023NSFSC0978)the Natural Science Starting Project of SWPU(No.2023QHZ018)。
文摘A solar steam generator(SSG)is an effective method for solving water shortages and protecting the environment,but its evaporation rate remains limited.Herein,Ga@EOG/PVA aerogel-based SSG with excellent photothermal seawater purification capabilities was prepared using liquid metal gallium(Ga),edge oxidized graphene(EOG),and polyvinyl alcohol(PVA).The‘‘nut-cake-like''structure formed by electrochemical oxidation of EOG encapsulated Ga nanoparticles enhances light absorption and heat conversion efficiency through multiple light scattering and surface plasmon resonance.Furthermore,the vertical pore structure of the aerogel mimics the xylem conduit in tree trunks,allowing rapid transmission of heat and water,thus increasing its evaporation capacity.Based on these attributes,the SSG demonstrated a light absorption rate of 98.2%and an evaporation rate of 5.13 kg.m^(-2).h^(-1)under one-sun illumination,surpassing previously reported values in the literature.Moreover,the SSG effectively treated heavy metal salts,organic dyes,wastewaters,and acidic or alkaline solutions.These findings highlight the potential effectiveness of the prepared aerogel for numerous of environmental remediation applications,especially in ensuring high water quality and safety for human consumption.
基金the State High- Tech Developments Plan of China!(No.86 3- 6 14- 0 2
文摘A 10MW High Temperature Gas Cooled Reactor (HTR-10) designed by the Institute of Nuclear Energy Technology (INET) is now being constructed. The steam generator (SG) in the HTR-10 is one of the most important components for reactor safety. The thermal-hydraulic performance of the SG was investigated. A full scale HTR-10 Steam Generator Two Tube Engineering Model Test Facility (SGTM-10) was installed and tested at INET. This paper describes the SGTM-10 thermal hydraulic experimental system in detail. The SGTM-10 simulates the actual thermal and structural parameters of the HTR-10. The SGTM-10 includes three separated loops: the primary helium loop, the secondary water loop, and the tertiary cooling water loop. Two parallel tubes are arranged in the test assembly. The main experimental equipment is shown in the paper. Expermental results are given illustrating the effects of the outlet pressures, the heating power, and the inlet subcooling.
基金supported by the National Natural Science Foundation of China (Grant No 10905093)the Program for New Century Excellent Talents in University of China (Grant No NCET-04-1006)the Foun-dation for the Author of National Excellent Doctoral Dissertation of China (Grant No 200136)
文摘Steam generator is optimized by applying entransy dissipation extremum principle and constructal theory and adopting analyti-cal method.The obtained results show that the optimal spacing between adjacent tubes,the mass flow rate of gas and the maximum entransy dissipation rate all depend on the dimensionless diameter of one tube,the dimensionless pressure difference number and the dimensionless length of flow channel of gas.Besides the three dimensionless groups,the optimal numbers of riser tubes and downcomer tubes and their summation all depend on the dimensionless height of one tube.The maximum entransy dissipation rate increases as the pressure difference that drives the gas flowing increases,and as the diameter of one tube and the length of flow channel both decrease.The mean heat flux in the heat transfer process of hot gas grows greatly,and the performance of the system is improved.Compared with the optimal construct with heat transfer rate maximization,the optimal construct with entransy dissipation rate maximization can improved the heat transfer effect of the steam generator more.
基金supported by the Tsinghua University Initiative Scientific Research Program(Nos.20131089216 and 20111080959)the National S&T Major Project(Grant No.2008ZX06901-001)
文摘Graphite dust has an important effect on the safety of high-temperature gas-cooled reactors(HTR).The flow field in the steam generator was studied by the computational fluid dynamics(CFD) method,with the results indicating that the friction velocity in the windward and the leeward of the heat transfer tubes is relatively low and is higher at the sides.Further analysis of the resuspension of graphite dust indicates that the resuspension fraction reaches nearly zero for particles with a diameter less than 1 μm,whereas it will increases as the helium velocity in the steam generator increases for particle size larger than 1 μm.Moreover,the resuspension fraction increases as the particle size increases.The results also indicate that resuspension of the particles with sizes larger than 1 μm exhibited obvious differences in different parts of the steam generator.
基金supported by the National Natural Science Foundation of China(Grant No.U2013214)the Self-Planned Task of the State Key Laboratory of Robotics and System(HIT),China(Grant No.SKLRS202001A03).
文摘Many heat transfer tubes are distributed on the tube plates of a steam generator that requires periodic inspection by robots.Existing inspection robots are usually involved in issues:Robots with manipulators need complicated installation due to their fixed base;tube mobile robots suffer from low running efficiency because of their structural restricts.Since there are thousands of tubes to be checked,task planning is essential to guarantee the precise,orderly,and efficient inspection process.Most in-service robots check the task tubes using row-by-row and column-bycolumn planning.This leads to unnecessary inspections,resulting in a long shutdown and affecting the regular operation of a nuclear power plant.Therefore,this paper introduces the structure and control system of a dexterous robot and proposes a task planning method.This method proceeds into three steps:task allocation,base position search,and sequence planning.To allocate the task regions,this method calculates the tool work matrix and proposes a criterion to evaluate a sub-region.And then all tasks contained in the sub-region are considered globally to search the base positions.Lastly,we apply an improved ant colony algorithm for base sequence planning and determine the inspection orders according to the planned path.We validated the optimized algorithm by conducting task planning experiments using our robot on a tube sheet.The results show that the proposed method can accomplish full task coverage with few repetitive or redundant inspections and it increases the efficiency by 33.31% compared to the traditional planning algorithms.
文摘The operation of complex systems can drift away from the initial design conditions,due to environmental condi-tions,equipment wear or specific restrictions.Steam generators are complex equipment and their proper opera-tion relies on the identification of their most relevant parameters.An approach to rank the operational parameters of a subcritical steam generator of an actual 360 MW power plant is presented.An Artificial Neural Network-ANN delivers a model to estimate the steam generator efficiency,electric power generation and flue gas outlet temperature as a function of seven input parameters.The ANN is trained with a two-year long database,with training errors of 0.2015 and 0.2741(mean absolute and square error)and validation errors of 0.32%and 2.350(mean percent and square error).That ANN model is explored by means of a combination of situations proposed by a Design of Experiment-DoE approach.All seven controlled parameters showed to be relevant to express both steam generator efficiency and electric power generation,while primary air flow rate and speed of the dynamic classifier can be neglected to calculate flue gas temperature as they are not statistically significant.DoE also shows the prominence of the primary air pressure in respect to the steam generator efficiency,electric power generation and the coal mass flow rate for the calculation of the flue gas outlet temperature.The ANN and DoE combined methodology shows to be promising to enhance complex system efficiency and helpful whenever a biased behavior must be brought back to stable operation.
文摘GP algorithm of correlation dimension computation is ameliorated which overcomes the shortage of traditional one. Improved process of GP algorithm takes the influence of temporal correlative pairs of points on correlation dimension into account and promotes the computational efficiency prominently. Iterative SVD method is applied to remove the influence of noise on the result of correlation dimension. The faults of steam flow turbulence and oil film disturbance which occur in 600 MW Steam Turbine Generator are analyzed and whose correlation dimensions are computed. More distinct quantitative index than FFT is gained to distinguish two faults and it’s of little importance to apply correlation dimension to study the influence of various factors on steam flow turbulence fault for nonexistence of convergent floor in correlation integral curve, which presents a new way to learn the operational function of large capacity steam turbine generator and carry out comprehensive condition monitoring.
基金supported by Basic and Applied Basic research foundation of Guangdong province(Nos.2021A1515010343 and 2022A1515011582)the Science and Technology Program of Guangdong Province(Nos.2021A0505030026 and 2022A0505050029).
文摘In the scenario of a steam generator tube rupture accident in a lead-cooled fast reactor,secondary circuit subcooled water under high pressure is injected into an ordinary-pressure primary vessel,where a molten lead-based alloy(typically pure lead or lead-bismuth eutectic(LBE))is used as the coolant.To clarify the pressure build-up characteristics under water-jet injection,this study conducted several experiments by injecting pressurized water into a molten LBE pool at Sun Yat-sen University.To obtain a further understanding,several new experimental parameters were adopted,including the melt temperature,water subcooling,injection pressure,injection duration,and nozzle diameter.Through detailed analyses,it was found that the pressure and temperature during the water-melt interaction exhibited a consistent variation trend with our previous water-droplet injection mode LBE experiment.Similarly,the existence of a steam explosion was confirmed,which typically results in a much stronger pressure build-up.For the non-explosion cases,increasing the injection pressure,melt-pool temperature,nozzle diameter,and water subcooling promoted pressure build-up in the melt pool.However,a limited enhancement effect was observed when increasing the injection duration,which may be owing to the continually rising pressure in the interaction vessel or the isolation effect of the generated steam cavity.Regardless of whether a steam explosion occurred,the calculated mechanical and kinetic energy conversion efficiencies of the melt were relatively small(not exceeding 4.1%and 0.7%,respectively).Moreover,the range of the conversion efficiency was similar to that of previous water-droplet experiments,although the upper limit of the jet mode was slightly lower.
文摘In complex systems,there is a kind of parameters having only a minor impact on the outputs in most cases,but their accurate values are still critical for the operation of systems.In this paper,the authors focus on the identification of these weak influence parameters in the complex systems and propose a identification model based on the parameter recursion.As an application,three parameters of the steam generator are identified,that is,the valve opening,the valve CV value,and the reference water level,in which the valve opening and the reference water level are weak influence parameters under most operating conditions.Numerical simulation results show that,in comparison with the multi-layer perceptron(MLP),the identification error rate is decreased.Actually,the average identification error rate for the valve opening decreases by 0.96%,for the valve CV decreases by 0.002%,and for the reference water level decreases by 12%after one recursion.After two recursions,the average identification error rate for the valve opening decreases by 11.07%,for the valve CV decreases by 2.601%,and for the reference water level decreases by 95.79%.This method can help to improve the control of the steam generator.
基金supported by Huazhong University of Science and Technology(No.2021XXJS036,3004013134)National Natural Science Foundation of China(No.51903099,22102059)+1 种基金the National Key Technology R&D Program of China(No.2020YFB1709301,2020YFB1709304,2021YFC2101705)the Innovation and Talent Recruitment Base of New Energy Chemistry and Device(No.B21003)。
文摘Harvesting solar energy in an effective manner for steam and electricity generation is a promising technique to simultaneously cope with the energy and water crises.However,the construction of efficient and easy scale-up photothermal materials for steam and electricity cogeneration remains challenging.Herein,we report a facile and cost-effective strategy to prepare MnO_(2)-decorated cotton cloth(MCx).The wide adsorption spectrum and excellent photothermal conversion ability of the in situ-formed MnO_(2)nanoparticles make the MCx to be advanced photothermal materials.Consequently,the hybrid device integrated with MCx as the photothermal layer and the thermoelectric(TE)module for electricity power conversion exhibits an extremely high evaporation rate of 2.24 kg m^(−2)h^(−1)under 1 kW m^(−2)irradiation,which is ranked among the most powerful solar evaporators.More importantly,during solar evaporation,the hybrid device produces an open-circuit voltage of 0.3 V and a power output of 1.6 W m^(−2)under 3 Sun irradiation,and outperforms most of the previously reported solar-driven electricity generation devices.Therefore,the integrated device with synergistic solar-thermal utilization opens up a green way toward simultaneous solar vapor and electric power generation in remote and resource-constrained areas.