Review on squeaking hips 被引量:1
1
作者 Yadin David Levy Selin Munir +1 位作者 Shane Donohoo William Lindsay Walter 《World Journal of Orthopedics》 2015年第10期812-820,共9页
Squeaking is a well-recognized complication for hardon-hard bearings.The nature of squeaking is not yet completely understood however it is considered a multifactorial phenomenon.Patient,implant,and surgical factors p... Squeaking is a well-recognized complication for hardon-hard bearings.The nature of squeaking is not yet completely understood however it is considered a multifactorial phenomenon.Patient,implant,and surgical factors play a role in squeaking.It is believed that mechanisms damaging the fluid film lubrication in which these bearings function optimally have a critical role.Such mechanisms include edge loading,stripe wear,impingement,third body particles and ceramic fracture.The resonance of metallic parts can produce noise in the human audible range hence the implant metallurgic composition and design may play a role.Implant positioning can facilitate impingement and edge loading enhancing the occurrence of squeaking.The recent introduction of large heads(> 36 mm) 4th generation ceramic-on-ceramic bearing may accentuate the conditions facilitating noise formation; however the current literature is insufficient.Clinically,squeaking may manifest in extreme hip positions or during normal gait cycle however it is rarely associated with pain.Evaluations of patients with squeaking include clinical and radiographic assessments.Computer tomography is recommended as it can better reveal ceramic breakage and implant malposition.The treatments for most squeaking patients include reassurance and activity modification.However for some,noise can be a problem,requiring further surgical intervention.In the occurrence of ceramic fracture,implant failure,extreme components malposition,instability and impingement,surgery should be advised.This review will aim to discuss the current literature regarding squeaking. 展开更多
关键词 squeaking Total HIP ARTHROPLASTY Ceramicon-ceramic LUBRICATION Edge loading METAL-ON-METAL
暂未订购
Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty 被引量:3
2
作者 Guo-Liang Wu Wei Zhu +2 位作者 Yan Zhao Qi Ma Xi-Sheng Weng 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第15期1861-1866,共6页
Objective: The present study aimed to review the characteristics and influencing factors of squeaking after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and to analyze the possible mechanisms of the audi... Objective: The present study aimed to review the characteristics and influencing factors of squeaking after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and to analyze the possible mechanisms of the audible noise. Data Sources: The data analyzed in this review were based on articles from PubMed and Web of Science. Study Selection: The articles selected for review were original articles and reviews found based on the following search terms: “total hip arthroplasty”, “ceramic-on-ceramic”, “hip squeaking”, and “hip noise.” Results: The mechanism of the squeaking remains unknown. The possible explanations included stripe wear, edge loading, a third body, fracture of the ceramic liner, and resonance of the prosthesis components. Squeaking occurrence is influenced by patient, surgical, and implant factors. Conclusions: Most studies indicated that squeaking after CoC THA was the consequence of increasing wear or impingement, caused by prosthesis design, patient characteristics, or surgical factors. However, as conflicts exist among different articles, the major reasons for the squeaking rernain to be identified. 展开更多
关键词 CERAMIC-ON-CERAMIC squeaking Total Hip Arthroptasty
原文传递
整车玻璃升降异响机理及消除方法研究
3
作者 范翠锋 王坤 胡广军 《汽车维修》 2025年第3期20-22,23,24,共5页
“异响”用英文BSR表示,是由Buzz,Squeak,Rattle三个英文首字母组成的名称。异响是发生和持续时间没有规律的非正常的声响,这些声响对于一个正常的车辆来说,是不应该存在且必须消除的质量缺陷。玻璃升降时出现的异响是整车中常见的异响... “异响”用英文BSR表示,是由Buzz,Squeak,Rattle三个英文首字母组成的名称。异响是发生和持续时间没有规律的非正常的声响,这些声响对于一个正常的车辆来说,是不应该存在且必须消除的质量缺陷。玻璃升降时出现的异响是整车中常见的异响,因其失效形式多样、涉及因素多、分析复杂,是整车生产厂分析和解决的难点。 展开更多
关键词 Squeak 整车玻璃升降 Rattle BUZZ 异响 质量缺陷 失效形式
在线阅读 下载PDF
Restoring Natural Hip Movements with Large Head (Ceramic on Ceramic) Total Hip Replacement: Experience of Our 150 Patients over 6 Years
4
作者 Sanjay Agarwala Mayank Vijayvargiya Sameer Chaudhari 《Open Journal of Orthopedics》 2017年第12期414-427,共14页
Background: Asian cultures require floor-seated positions demanding a high range of motion (ROM). Ceramic-On-Ceramic (COC) interface allowed the use of larger head with reduced wear debris generation and adverse tissu... Background: Asian cultures require floor-seated positions demanding a high range of motion (ROM). Ceramic-On-Ceramic (COC) interface allowed the use of larger head with reduced wear debris generation and adverse tissue reactions. This study was conducted to analyze 6-year clinical-radiological outcome with large head fourth generation DeltaMotion&reg;ceramic-on-ceramic (COC) hip articulation, with special emphasis on postoperative ROM, ability to sit cross-legged, stability, hip noise and revision surgery. Material and Methods: 150 consecutive hips were operated for primary cementless Total Hip Replacement (THR) using DeltaMotion&reg;at a tertiary care center in Mumbai, India, between January 2010 and January 2015. Clinico-radiological outcome was assessed using the Harris Hip Score (HHS) and radiographs at 6 weeks, 6 months, and annually thereafter. Results: 108 (74.5%) patients were males and 37 (25.5%) were females with an average age of 50.87 years. Mean follow-up was 54 months (range: 37 - 86 months). The mean ROM was 120° in flexion, 10° in extension, 30° in adduction, 45° in abduction, 25° in internal rotation and 25° in external rotation. The mean HHS showed a statistically significant improvement of 64.5% (from 54.66 ± 6.42 pre-operatively to 89.95 ± 4.32 post operatively) (p-value: 0.001). 92% of patients were able to sit in squatting position and 92% were able to sit cross-legged on the floor at last follow-up. 0.7% joints (1 hip) had squeaking. Considering no revision surgery as the end point, 6-year prosthesis survivorship was 100%. Complications (superficial infection) occurred in three hips (2%). All patients reported to be satisfied with their outcome after surgery. Conclusion: We infer that DeltaMotion large head COC bearing allows scope for using larger head size in relatively smaller Indian hips due to factory fitted ceramic lining. At 6-year follow-up, high activity level was observed with excellent clinical-radiological outcomes and component longevity in relatively young Indian population. 展开更多
关键词 CERAMIC-ON-CERAMIC Total HIP ARTHROPLASTY squeaking Prosthesis SURVIVORSHIP Harris HIP Score
暂未订购
Evaluation of vibration and sound quality according to battery voltage change while moving a power seat in an automobile forward or backward 被引量:1
5
作者 Kang-seok Seo Doo-seuk Choi Key-sun Kim 《Journal of Central South University》 SCIE EI CAS 2014年第10期3844-3849,共6页
The changes in vibration, sound, and sound quality with changes in the driving voltage of a power seat motor from 12.5 to 14.5 V were measured and analyzed, which was used in real vehicles. BSR(buzz, squeak, rattle), ... The changes in vibration, sound, and sound quality with changes in the driving voltage of a power seat motor from 12.5 to 14.5 V were measured and analyzed, which was used in real vehicles. BSR(buzz, squeak, rattle), which occurs for the power seat mechanism during sliding operation, was also evaluated. In addition, the results were expressed in terms of sound quality metrics, which measure the RPM change and sound level versus voltage to analyze their statistical correlation. Furthermore, vibration measurement and analysis were conducted simultaneously to determine the noisiest conditions and the source of the noise. The changes in RPM and voltage of a motor, in addition to vibration and noise, were measured at the same time to determine how noise, RPM, and voltage are interrelated. 展开更多
关键词 seat vibration seat noise sound quality voltage BUZZ squeak and rattle(BSR)