期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Biochemical determination of lipid content in hepatic steatosis by the Soxtec method 被引量:1
1
作者 Elizabeth Hijona Lander Hijona +4 位作者 Mikel Larzabal Cristina Sarasqueta Pablo Aldazabal Juan Arenas Luis Bujanda 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第12期1495-1499,共5页
AIM:To establish a quantitative method to measure the amount of lipids.METHODS:The livers of 53 male Wistar rats(225 g) with different degrees of hepatic steatosis were studied.This model of hepatic steatosis was base... AIM:To establish a quantitative method to measure the amount of lipids.METHODS:The livers of 53 male Wistar rats(225 g) with different degrees of hepatic steatosis were studied.This model of hepatic steatosis was based on a high carbohydrate,fat-free modified diet.Biopsies were classified into four grades depending on fat accumulation,using the Kleiner and Brunt classification.Total fat was studied by the Soxtec method(SoxtecTM 2050 Auto Fat Extraction System),and agreement between both assays was assessed by calculating theκ coefficient.RESULTS:According to the histological classification,38% of rats presented grade 0,21% grade 1,22% grade 2 and 20% grade 3.The amount of fat per 100 g tissue was 2.60±0.64 g for grade 0,3.87±1.59 g for grade 1,5.82±1.37 g for grade 2 and 8.68± 2.30 g for grade 3.Statistically significant differences were found between the mean values for each of the histological grades(P<0.05).The correlation for the quantification of fat in the liver between both assays was moderate(κ=0.60).CONCLUSION:The biochemical quantification of fat in liver tissue by the Soxtec method was correlated with the histological classification,although the agreement between the two tests was only moderate. 展开更多
关键词 Liver steatosis soxtec method Quantitative analysis HISTOLOGY BIOCHEMISTRY
暂未订购
基于Box-Behnken对纸浆丙酮可溶物索氏提取方法的优化及应用
2
作者 张问 彭丽萍 +3 位作者 郑剑 叶晓媚 郭智欣 郑咏玲 《中国造纸》 北大核心 2025年第9期118-122,共5页
本研究以丙酮可溶物含量作为评价指标,采用Box-Behnken响应面法对纸浆丙酮可溶物自动索氏提取方法进行优化。结果表明,最优提取参数为提取温度76℃、提取时间25 min、提取溶剂体积64 mL。经实验验证,该方法检出限为0.013%,加标回收率>... 本研究以丙酮可溶物含量作为评价指标,采用Box-Behnken响应面法对纸浆丙酮可溶物自动索氏提取方法进行优化。结果表明,最优提取参数为提取温度76℃、提取时间25 min、提取溶剂体积64 mL。经实验验证,该方法检出限为0.013%,加标回收率>95%,重复性变异系数<5%,再现性变异系数<10%,检测结果满足GB/T 27417—2017要求,表明该方法准确性高、重现性好,满足工业化纸浆生产的质量控制需求,为丙酮可溶物检测提供了更高效可靠的解决方案。 展开更多
关键词 自动索氏提取 纸浆 丙酮可溶物测定 Box-Behnken响应面法
在线阅读 下载PDF
植物油不溶性杂质含量测定方法的改进 被引量:1
3
作者 张春娥 张蕊 张丽 《粮油食品科技》 北大核心 2014年第4期61-62,共2页
针对现有国标GB/T 15688—2008方法在测定植物油不溶性杂质含量时,滤纸表面油渍洗涤步骤耗时长,测定效率低的缺点,研究用Soxtec索氏浸提装置的淋洗方式替代国标规定的滤纸表面油渍冲洗方法,并对两种方法进行比较。结果表明:采用Soxtec... 针对现有国标GB/T 15688—2008方法在测定植物油不溶性杂质含量时,滤纸表面油渍洗涤步骤耗时长,测定效率低的缺点,研究用Soxtec索氏浸提装置的淋洗方式替代国标规定的滤纸表面油渍冲洗方法,并对两种方法进行比较。结果表明:采用Soxtec淋洗方式结果准确,与标准方法相比,连续处理6个样品可节省操作时间至少5 h,且具有重现性好,节约试剂和减少试剂污染等优点。对于未经脱色的深色油脂,Soxtec淋洗也能充分洗掉滤纸上残留的色素。因此,同时分析多个油脂样品不溶性杂质含量时,采用Soxtec索氏浸提装置淋洗方式效率更高。 展开更多
关键词 植物油 不溶性杂质 索氏抽提装置
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部