The calibration methods for Multi-Filter Rotating Shadowband Radiometer: a review 被引量:1
1
作者 Maosi CHEN John DAVIS +2 位作者 Hongzhao TANG Carolyn OWNBY Wei GAO 《Frontiers of Earth Science》 SCIE CAS CSCD 2013年第3期257-270,共14页
The continuous, over two-decade data record from the Multi-Filter Rotating Shadowband Radiometer (MFRSR) is ideal for climate research which requires timely and accurate information of important atmospheric componen... The continuous, over two-decade data record from the Multi-Filter Rotating Shadowband Radiometer (MFRSR) is ideal for climate research which requires timely and accurate information of important atmospheric components such as gases, aerosols, and clouds. Except for parameters derived from MFRSR measurement ratios, which are not impacted by calibration error, most applications require accurate calibration factor(s), angular correction, and spectral response function(s) from calibration. Although a laboratory lamp (or reference) calibration can provide all the information needed to convert the instrument readings to actual radiation, in situ calibration methods are implemented routinely (daily) to fill the gaps between lamp calibrations. In this paper, the basic structure and the data collection and pretreatment of the MFRSR are described. The laboratory lamp calibration and its limita- tions are summarized. The cloud screening algorithms for MFRSR data are presented. The in situ calibration methods, the standard Langley method and its variants, the ratio-Langley method, the general method, Alexandrov's comprehensive method, and Chen's multi-channel method, are outlined. The reason that all these methods do not fit for all situations is that they assume some properties, such as aerosol optical depth (AOD), total optical depth (TOD), precipitable water vapor (PWV), effective size of aerosol particles, or angstrom coefficient, are invariant over time. These properties are not universal and some of them rarely happen. In practice, daily calibration factors derived from these methods should be smoothed to restrain elTor. 展开更多
关键词 Multi-Filter Rotating shadowband Radiometer (MFRSR) CALIBRATION REVIEW
原文传递
遮光环订正系数的修正与计算方法 被引量:1
2
作者 张顺谦 冯万瑞 +1 位作者 张纬敏 时建华 《太阳能学报》 EI CAS CSCD 北大核心 1997年第2期157-163,共7页
根据北京、攀枝花、福州、海口等地的对比观测资料,指出现用遮光环订正系数普遍偏小,不能完全反映不同地方的云天状况等,直接辐射表存在跟踪不良的现象。利用试验求得的订正系数fs与订正系数的理论值fl之差,与总云量n、纬度φ... 根据北京、攀枝花、福州、海口等地的对比观测资料,指出现用遮光环订正系数普遍偏小,不能完全反映不同地方的云天状况等,直接辐射表存在跟踪不良的现象。利用试验求得的订正系数fs与订正系数的理论值fl之差,与总云量n、纬度φ和(月份—6)的绝对值Δyf进行多元回归,得到回归方程:fs-fl=0.0538+0.1715φ/90+0.0111Δyf-0.0117n,其复相关系数r高达0.97,通过回代检验,证明由该方程计算得到的订正系数比现用系数更准确。该方程的意义在于可定量求出不同纬度不同时间的修正量,其大小与φ和Δyf成正相关而与总云量n成负相关,结果使得实际订正系数纬度和月份间的差距比理论值间的差距小得多,而在低纬度夏季多云的地方,修正量可能为负,即实际订正系数可能小于理论值。 展开更多
关键词 遮光环 订正系数 修正量 计算方法 太阳辐射
在线阅读 下载PDF
一个检验太阳光度计Langley定标结果可靠性的方法 被引量:3
3
作者 董自鹏 余兴 +5 位作者 卢娣 戴进 李星敏 陈闯 彭艳 董妍 《大气科学》 CSCD 北大核心 2020年第1期39-52,共14页
准确反演气溶胶光学厚度(AOD)在气溶胶气候效应和环境效应研究中至关重要,仪器定标是目前AOD反演过程中最大的不确定性来源。Langley法作为应用最广泛的光度计定标方法,其对天气条件和大气洁净度要求苛刻,这在大气污染较重的地区难以实... 准确反演气溶胶光学厚度(AOD)在气溶胶气候效应和环境效应研究中至关重要,仪器定标是目前AOD反演过程中最大的不确定性来源。Langley法作为应用最广泛的光度计定标方法,其对天气条件和大气洁净度要求苛刻,这在大气污染较重的地区难以实现,并可能导致AOD反演误差偏大。为了降低由不恰当的Langley定标所引起的AOD反演误差,本文提出一个利用辐射传输模式结合地面太阳直接辐射观测数据检验Langley定标结果合理性的方法,并利用西安2013年6月至2015年12月多滤波旋转遮光带辐射计(MFRSR)和直接辐射表(NIP)观测资料,探讨了方法的可行性。结果表明,该方法能够将Langley定标结果限定在较小的波动范围内,有效降低由定标不确定性引起的AOD反演误差,有助于提高单站点AOD观测精度。 展开更多
关键词 Langley定标方法 多滤波旋转遮光带辐射计 气溶胶 SBDART辐射传输模式
在线阅读 下载PDF