期刊文献+
共找到37篇文章
< 1 2 >
每页显示 20 50 100
A self-calibrating fluorescent probe for the selective detection and bioimaging of HClO
1
作者 GAO Wei SONG Meiqi +4 位作者 REN Xuan BAI Jianliang SU Jing MA Jianlong WANG Zhijun 《无机化学学报》 北大核心 2025年第6期1173-1182,共10页
In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission sp... In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission spectrum range:640-740 nm)and coumarin fluorophore(emission spectrum range:440-600 nm)as signal output units,thereby achieving effective spectral separation and highly selective detection of HClO.Under physiological pH conditions,HClO triggers an oxidation-cleavage reaction,releasing methylene blue and coumarin,which emit distinct red and green fluorescence,respectively.This dual-emission feature enabled rapid HClO detection with two-channel detection limits of 25.13 nmol·L^(-1)(green channel)and 31.55 nmol·L^(-1)(red channel).Furthermore,in cell imaging experiments,this probe demonstrated excellent cell membrane permeability and low cytotoxicity,successfully enabling the monitoring of both endogenous and exogenous HClO in living cells.By incorporating a twochannel self-calibration system,the probe effectively mitigated signal variations caused by instrumental or environmental interference,substantially improving detection sensitivity and reliability. 展开更多
关键词 fluorescent probe fluorescent crosstalk self-calibrated hypochloric acid dual channel
在线阅读 下载PDF
Tb(Ⅲ)functionalized MOF based self-calibrating sensor integrated with logic gate operation for efficient epinephrine detection in serum 被引量:3
2
作者 Dongsheng Zhao Wenqian Li +4 位作者 Rongmei Wen Wencui Li Xin Liu Xiutang Zhang Liming Fan 《Journal of Rare Earths》 SCIE EI CAS CSCD 2024年第5期987-994,I0006,共9页
By anchoring Tb^(3+)ions on its free carboxyl groups of the nanocaged NiMOF,a dual-emission self-calibrating sensor of Tb^(3+)@NiMOF was fabricated through coordination post-synthetic modification(PSM)strategy.With Tb... By anchoring Tb^(3+)ions on its free carboxyl groups of the nanocaged NiMOF,a dual-emission self-calibrating sensor of Tb^(3+)@NiMOF was fabricated through coordination post-synthetic modification(PSM)strategy.With Tb^(3+)ions as the secondary fluorescent signal and sensing active sites,Tb^(3+)@NiMOF presents great potentials in visually and efficiently monitoring EPI in serum,with high sensitivity and selectivity,fast response,excellent recyclable,and the low detection limit(LOD,3.06 ng/mL).Furthermore,a tandem combinational logic gate based intelligent detection system was constructed to improve the practicability and convenience of epinephrine(EPI)detection in serum by comparing the light emitted colour with the series standard colour cards preset in the smartphone.This work provides a promising approach of developing metal-organic frameworks(MOFs)based self-calibrating sensors for intelligent detection of bioactive molecules. 展开更多
关键词 Metal-organic framework Post-synthetic modification self-calibrating sensor Logic gate operation Epinephrine detection Rare earths
原文传递
Self-calibrating probes constructed on a unique dual-emissive fluorescence platform for the precise tracking of cellular senescence
3
作者 Xu Qu Pengzhao Wu +5 位作者 Kaixuan Duan Guangwei Wang Liang-Liang Gao Yuan Guo Jianjian Zhang Donglei Shi 《Chinese Chemical Letters》 SCIE CAS CSCD 2024年第12期378-381,共4页
Humanβ-galactosidase(β-gal)is recognized as a crucial biomarker for evaluating senescence at the cellular and tissue levels in humans.However,tools to precisely track the endogenousβ-gal are still limited.Herein,we... Humanβ-galactosidase(β-gal)is recognized as a crucial biomarker for evaluating senescence at the cellular and tissue levels in humans.However,tools to precisely track the endogenousβ-gal are still limited.Herein,we present two novel self-calibratingβ-gal probes 7a and 7b which were constructed on a unique green/red dual-emissive fluorescence platform.The two probes inherently exhibited a stable green fluorescence signal impervious toβ-gal activity,serving as a reliable internal reference.They also displayed a progressively diminishing red fluorescence signal with the increasing ofβ-gal expression levels.The dual behavior endows them with self-calibration capacity and then renders excellently selective and sensitive for precisely monitoringβ-gal activity.Notably,compared with E.coliβ-gal,the two probes are more effectively response to A.oryzaeβ-gal homologous to humanβ-gal,indicating their unique species-selectivity.Furthermore,7a was validated for its effectiveness in determining senescenceassociatedβ-galactosidase(SA-β-gal)expression in senescent NRK-52E and HepG2 cells,underscoring its practical applicability in senescence research. 展开更多
关键词 Senescence associatedβ-galactosidase Dual-emission self-calibrATION Cell imaging Fluorescent probes
原文传递
Three-step self-calibrating generalized phase-shifting interferometry
4
作者 Yu Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第3期234-240,共7页
An accurate and fast three-step self-calibrating generalized phase-shifting interferomertry(SGPSI) is proposed. In this approach, two new phase-shifting signals are constructed by the difference interferograms normali... An accurate and fast three-step self-calibrating generalized phase-shifting interferomertry(SGPSI) is proposed. In this approach, two new phase-shifting signals are constructed by the difference interferograms normalization and noise suppressing, then the unknown phase shift between the two difference phase-shifting signals is estimated quickly through searching the minimum coefficient of variation of the modulation amplitude, a limited number of pixels are selected to participate in the search process to further save time, and finally the phase is reconstructed through the searched phase shift. Through the reconstruction of phase map by the simulation and experiment, and the comparison with several mature algorithms, the good performance of the proposed algorithm is proved, and it eliminates the limitation of requiring more than three phase-shifting interferograms for high-precision SGPSI. We expect this method to be widely used in the future. 展开更多
关键词 self-calibrating generalized phase-shifting interferomertry phase shift difference interferograms modulation amplitude
原文传递
Target self-calibration ratiometric fluorescent sensor based on facile-synthesized europium metal-organic framework for multi-color visual detection of levofloxacin
5
作者 Li Li Lin-Lin Zhang +7 位作者 Yansha Gao Lu-Ying Duan Wuying Yang Xigen Huang Yanping Hong Jiaxin Hong Lin Yuan Limin Lu 《Chinese Chemical Letters》 2025年第7期420-424,共5页
Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibratio... Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibration ratiometric fluorescent sensing platform has been designed for sensitive visual detection of levofloxacin(LEV)based on fluorescent europium metal-organic framework(Eu-MOF)probe.Specifically,the Eu-MOF was facilely synthesized via directly mixing Eu^(3+)with 1,10-phenanthroline-2,9-dicarboxylic acid(PDA)ligand at room temperature,which exhibited well-stable red fluorescence at 612 nm.Upon the addition of target LEV,the significant fluorescence quenching from Eu^(3+)was observed owing to the inner filter effect between the Eu-MOF and LEV.While the intrinsic fluorescence for LEV at 462nm was gradually enhanced,thereby realizing the self-calibration ratiometric fluorescence responses to LEV.Through this strategy,LEV can be detected down to 27 nmol/L.Furthermore,a test paper-based Eu-MOF integrated with the smartphone assisted RGB color analysis was exploited for the quantitative monitoring of LEV through the multi-color changes from red to blue,thus achieved portable,convenient and visual detection of LEV in honey and milk samples.Therefore,the developed strategy could provide a useful tool for supporting the practical on-site test in food samples. 展开更多
关键词 Target self-calibration Ratiometric fluorescence Europium metal-organic Framework Multi-color visual detection LEVOFLOXACIN
原文传递
A Fractional-N CMOS DPLL with Self-Calibration
6
作者 刘素娟 杨维明 +2 位作者 陈建新 蔡黎明 徐东升 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2005年第11期2085-2091,共7页
A digital phase-locked loop (DPLL) based on a new digital phase-frequency detector is presented. The self-calibration technique is employed to acquire wide lock range,low jitter, and fast acquisition. The DPLL works... A digital phase-locked loop (DPLL) based on a new digital phase-frequency detector is presented. The self-calibration technique is employed to acquire wide lock range,low jitter, and fast acquisition. The DPLL works from 60 to 600MHz at a supply voltage of 1.8V. It also features a fraetional-N synthesizer with digital 2nd-order sigma-delta noise shaping, which can achieve a short lock time,a high frequency resolution,and an improved phase-noise spectrum. The DPLL has been implemented in SMIC 0. 18μm 1.8V 1P6M CMOS technology. The peak-to-peak jitter is less than 0. 8% of the output clock period and the lock time is less than 150 times of the reference clock period after the pre-divider. 展开更多
关键词 digital phase-locked loop phase-frequency detector self-calibrATION voltage controlled oscillator FRACTIONAL-N
在线阅读 下载PDF
Capacitor self-calibration technique used in time-interleaved successive approximation ADC
7
作者 殷勤 戚韬 +1 位作者 吴光林 吴建辉 《Journal of Southeast University(English Edition)》 EI CAS 2006年第2期164-168,共5页
A capacitor self-calibration circuit used in a successive approximation analog-to-digital converter (SA-ADC) is presented. This capacitor self-calibration circuit can calibrate erroneous data and work with the ADC b... A capacitor self-calibration circuit used in a successive approximation analog-to-digital converter (SA-ADC) is presented. This capacitor self-calibration circuit can calibrate erroneous data and work with the ADC by adding an additional clock period. This circuit is used in a 10 bit 32 Msample/s time-interleaved SA- ADC. The chip is implemented with Chart 0. 25 μm 2. 5 V process and totally occupies an area of 1.4 mm× 1.3 mm. After calibration, the simulated signal-to-noise ratio (SNR) is 59. 586 1 dB and the spurious-free dynamic range (SFDR) is 70. 246 dB at 32 MHz. The measured signal-to-noise and distortion ratio (SINAD) is 44. 82 dB and the SFDR is 63. 760 4 dB when the ADC samples a 5.8 MHz sinusoid wave. 展开更多
关键词 capacitor self-calibration analog-to-digital converter successive approximation time-interleaved
在线阅读 下载PDF
Self-calibration and Compensation of Setting Errors for Surface Profile Measurement of a Microstructured Roll Workpiece 被引量:4
8
作者 GAO Wei XU Bin +2 位作者 TAKEISHI Toshiki SHIMIZU Yuki ITO So 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第1期14-22,共9页
Microstructured roll workpieces have been widely used as functional components in the precision industries. Current researches on quality control have focused on surface profile measurement of microstructured roll wor... Microstructured roll workpieces have been widely used as functional components in the precision industries. Current researches on quality control have focused on surface profile measurement of microstructured roll workpieces, and types of measurement systems and measurement methods have been developed. However, low measurement efficiency and low measurement accuracy caused by setting errors are the common disadvantages for surface profile measurement of microstructured roll workpieces. In order to shorten the measurement time and enhance the measurement accuracy, a method for self-calibration and compensation of setting errors is proposed for surface profile measurement of microstructured roll workpieces. A measurement system is constructed for the measurement, in which a precision spindle is employed to rotate the roll workpiece and an air-bearing displacement sensor with a micro-stylus probe is employed to scan the microstructured surface of the roll workpiece. The resolution of the displacement sensor is 0.14 nm and that of the rotary encoder of the spindle was 0.15r~. Geometrical and mathematical models are established for analyzing the influences of the setting errors of the roll workpiece and the displacement sensor with respect to the axis of the spindle, including the eccentric error of the roll workpiece, the offset error of the sensor axis and the zero point error of the sensor output. Measurement experiments are carded out on a roll workpiece on which periodic microstructures are a period of 133 i^m along the circumferential direction. Experimental results demonstrate the feasibility of the self-compensation method. The proposed method can be used to detect and compensate the setting errors without using any additional accurate artifact. 展开更多
关键词 measurement profile setting error self-calibrATION COMPENSATION microstructure roll workpiece
在线阅读 下载PDF
Integration of Tracer Test Data to Refine Geostatistical Hydraulic Conductivity Fields Using Sequential Self-Calibration Method 被引量:5
9
作者 胡晓农 蒋小伟 万力 《Journal of China University of Geosciences》 SCIE CSCD 2007年第3期242-256,共15页
On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the m... On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the methods are not suited to directly integrate dynamic production data, such as, hydraulic head and solute concentration, into the study of conductivity distribution. These data, which record the flow and transport processes in the medium, are closely related to the spatial distribution of hydraulic conductivity. In this study, a three-dimensional gradient-based inverse method--the sequential self-calibration (SSC) method--is developed to calibrate a hydraulic conductivity field, initially generated by a geostatistical simulation method, conditioned on tracer test results. The SSC method can honor both local hydraulic conductivity measurements and tracer test data. The mismatch between the simulated hydraulic conductivity field and the reference true one, measured by its mean square error (MSE), is reduced through the SSC conditional study. In comparison with the unconditional results, the SSC conditional study creates the mean breakthrough curve much closer to the reference true curve, and significantly reduces the prediction uncertainty of the solute transport in the observed locations. Further, the reduction of uncertainty is spatially dependent, which indicates that good locations, geological structure, and boundary conditions will affect the efficiency of the SSC study results. 展开更多
关键词 sequential self-calibration tracer test hydraulic conductivity geostatistical simulation inverse problem
在线阅读 下载PDF
New self-calibration approach to space robots based on hand-eye vision 被引量:3
10
作者 刘宇 刘宏 +1 位作者 倪风雷 徐文福 《Journal of Central South University》 SCIE EI CAS 2011年第4期1087-1096,共10页
To overcome the influence of on-orbit extreme temperature environment on the tool pose(position and orientation) accuracy of a space robot,a new self-calibration method based on a measurement camera(hand-eye vision) a... To overcome the influence of on-orbit extreme temperature environment on the tool pose(position and orientation) accuracy of a space robot,a new self-calibration method based on a measurement camera(hand-eye vision) attached to its end-effector was presented.Using the relative pose errors between the two adjacent calibration positions of the space robot,the cost function of the calibration was built,which was different from the conventional calibration method.The particle swarm optimization algorithm(PSO) was used to optimize the function to realize the geometrical parameter identification of the space robot.The above calibration method was carried out through self-calibration simulation of a six-DOF space robot whose end-effector was equipped with hand-eye vision.The results showed that after calibration there was a significant improvement of tool pose accuracy in a set of independent reference positions,which verified the feasibility of the method.At the same time,because it was unnecessary for this method to know the transformation matrix from the robot base to the calibration plate,it reduced the complexity of calibration model and shortened the error propagation chain,which benefited to improve the calibration accuracy. 展开更多
关键词 space robot self-calibrATION cost function hand-eye vision particle swarm optimization algorithm
在线阅读 下载PDF
A Self-calibration Bundle Adjustment Algorithm Based on Block Matrix Cholesky Decomposition Technology 被引量:3
11
作者 Huasheng SUN Yuan ZHANG 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第1期11-30,共20页
In this study,the problem of bundle adjustment was revisited,and a novel algorithm based on block matrix Cholesky decomposition was proposed to solve the thorny problem of self-calibration bundle adjustment.The innova... In this study,the problem of bundle adjustment was revisited,and a novel algorithm based on block matrix Cholesky decomposition was proposed to solve the thorny problem of self-calibration bundle adjustment.The innovation points are reflected in the following aspects:①The proposed algorithm is not dependent on the Schur complement,and the calculation process is simple and clear;②The complexities of time and space tend to O(n)in the context of world point number is far greater than that of images and cameras,so the calculation magnitude and memory consumption can be reduced significantly;③The proposed algorithm can carry out self-calibration bundle adjustment in single-camera,multi-camera,and variable-camera modes;④Some measures are employed to improve the optimization effects.Experimental tests showed that the proposed algorithm has the ability to achieve state-of-the-art performance in accuracy and robustness,and it has a strong adaptability as well,because the optimized results are accurate and robust even if the initial values have large deviations from the truth.This study could provide theoretical guidance and technical support for the image-based positioning and 3D reconstruction in the fields of photogrammetry,computer vision and robotics. 展开更多
关键词 bundle adjustment self-calibrATION block matrix Cholesky decomposition
在线阅读 下载PDF
An improved self-calibration approach based on adaptive genetic algorithm for position-based visual servo 被引量:1
12
作者 Ding LIU Xiongjun WU Yanxi YANG 《控制理论与应用(英文版)》 EI 2008年第3期246-252,共7页
An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the ... An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the positionbased visual servo technique which exploits the singular value property of the essential matrix. Specifically, a suitable dynamic online cost function is generated according to the property of the three singular values. The visual servo process is carried out simultaneous to the dynamic self-calibration, and then the cost function is minimized using the adaptive genetic algorithm instead of the gradient descent method in G. Chesi's approach. Moreover, this method overcomes the limitation that the initial parameters must be selected close to the true value, which is not constant in many cases. It is not necessary to know exactly the camera intrinsic parameters when using our approach, instead, coarse coding bounds of the five parameters are enough for the algorithm, which can be done once and for all off-line. Besides, this algorithm does not require knowledge of the 3D model of the object. Simulation experiments are carried out and the results demonstrate that the proposed approach provides a fast convergence speed and robustness against unpredictable perturbations of camera parameters, and it is an effective and efficient visual servo algorithm. 展开更多
关键词 Dynamic self-calibration Visual servo Adaptive genetic algorithm Parameter optimizing Essential matrix Computer vision
在线阅读 下载PDF
Camera Self-Calibration in Computer Vision with Precise Estimation of Initial Parameters 被引量:1
13
作者 裴明涛 于连庆 +1 位作者 刘鹏 贾云得 《Journal of Beijing Institute of Technology》 EI CAS 2004年第2期152-156,共5页
A key problem that plagues camera self-calibration, namely that the classical self-calibration algorithms are very sensitive to the initial values of the camera intrinsic parameters, is analyzed and a practical soluti... A key problem that plagues camera self-calibration, namely that the classical self-calibration algorithms are very sensitive to the initial values of the camera intrinsic parameters, is analyzed and a practical solution is provided. The effect of the camera intrinsic parameters, mainly the principal point and the skew factor is first discussed. Then a practical method via a controlled motion of the camera is introduced so as to obtain an accurate estimation of these parameters. Feasibility of this approach is illustrated by carrying out comprehensive experiments using synthetic data as well as real image sequences. Unreasonable initial values can often make self-calibration impossible, yet a precise initialization guarantees a better and successful reconstruction. Trying to obtain a more reasonable initialization is worthwhile the effort in camera self-calibration. 展开更多
关键词 self-calibrATION Euclidean reconstruction computer vision
在线阅读 下载PDF
NOVEL METHOD FOR ERROR ANALYSIS AND SELF-CALIBRATION OF LASER TRACKING MIRROR MECHANISM 被引量:2
14
作者 OUYANG Jianfei LIU Wanli +2 位作者 QU Xinghua YAN Yonggang WANG Zhankui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第4期1-6,共6页
Laser tracking system (LTS) is an advanced device for large size 3D coordinates measuring with the advantages of broad range, high speed and high accuracy. However, its measuring accuracy is highly dominated by the ... Laser tracking system (LTS) is an advanced device for large size 3D coordinates measuring with the advantages of broad range, high speed and high accuracy. However, its measuring accuracy is highly dominated by the geometric errors of the tracking mirror mechanism. Proper calibration of LTS is essential prior to the use of it for metrology. A kinematics model that describes not only the motion but also the geometric variations of LTS is developed. Through error analysis of the proposed model, it is claimed that gimbals axis misalignments and tracking mirror center off-set are the key contributors to measuring errors of LTS. A self-calibration method is presented of calibrating LTS with planar constraints. Various calibration strategies utilizing single-plane and multiple-plane constraints are proposed for different situations. For each calibration strategy, issues about the error parameter estimation of LTS are exploded to find out in which conditions these parameters can be uniquely estimated. Moreover, these conditions reveal the applicability of the planar constraints to LTS self-calibration. Intensive studies have been made to check validity of the theoretical results. The results show that the measuring accuracy of LTS has increased by 5 times since this technique for calibration is used. 展开更多
关键词 Laser tracking Error analysis self-calibration Planar constraints Tracking mirror
在线阅读 下载PDF
Self-calibration and algorithm of sample set of piezoresistive pressure sensors
15
作者 黄晓因 晋芳伟 周平 《Journal of Shanghai University(English Edition)》 CAS 2007年第2期178-181,共4页
Aiming at piezoresistive pressure sensors, this paper studies simulation of standard pressure by using benchmark current source and self-calibration of the sampling data characteristics. A data fusion algorithm for sa... Aiming at piezoresistive pressure sensors, this paper studies simulation of standard pressure by using benchmark current source and self-calibration of the sampling data characteristics. A data fusion algorithm for sample set is presented which transforms a surface problem into a curve fitting and interpolation problem. The simulation result shows that benchmark current source simulating pressure is successful and data fusion algorithm is effective. The maximum measurement error is only 0.098 kPa and maximum relative error is 0.92% at 0-45 kPa and -10-45~C. 展开更多
关键词 pressure sensor constant current source SAMPLE data fusion self-calibration.
在线阅读 下载PDF
Self-calibration Applied in Converting Simulation Surveying
16
作者 WANG Ren ZHU Xinhui 《Geo-Spatial Information Science》 2007年第1期57-60,共4页
In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every par... In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every part of production. In order to get three-dimensional information of objects, commercial digital camera must be examined. For a long time, digital camera has been examined by DLT. Then there must be a high-precision control field. For realizing surveying without control points, a method for self-calibration is proposed. 展开更多
关键词 absolute conic absolute quadric self-calibrATION
在线阅读 下载PDF
A new approach to land-use simulation that integrates macro-and microspatial characteristics:A case study of Wuhan,China 被引量:1
17
作者 LI Muchun LI Boyan +1 位作者 FENG Qi WANG Yunchen 《Journal of Geographical Sciences》 SCIE CSCD 2024年第10期2003-2027,共25页
Land-use and land-cover change(LUCC)simulations are powerful tools for evaluating and predicting future landscape dynamics amid rapid human-nature interactions to support decision-making.However,existing models often ... Land-use and land-cover change(LUCC)simulations are powerful tools for evaluating and predicting future landscape dynamics amid rapid human-nature interactions to support decision-making.However,existing models often overlook spatial heterogeneity and temporal dependencies when modeling LUCC at both the macro and microscales.In this paper,we propose a new model,a self-calibrated convolutional neural network-based cellular automata(SC–CNN–CA)model,which integrates macro-and microspatial characteristics to simulate complex interactions among land-use types.The SC-CNN-CA model incorporates a self-calibration module using Gaussian functions to capture macrotrend such as urban sprawl while accounting for microlevel land-use interactions such as neighborhood effects.The results indicated that(1)the neighborhood effect between agricultural land and urban land tended to“increase followed by a decrease.”(2)Urban sprawl in Wuhan was highly compact,with a relatively high intensity of urban expansion at distances between 11.96 km and 24.44 km.(3)Compared with the other CA models tested,the SC-CNN-CA model demonstrated superior performance,achieving an overall accuracy of 84.12% and a figure of merit of 20.20%.This new model can enhance our understanding of historical LUCC trajectories and improve predictions of spatially explicit information for efficient land resource and urban management. 展开更多
关键词 land-use change modeling land-system behaviors cellular automata self-calibrATION WUHAN
原文传递
Long-term outcomes of urethral balloon dilation for anterior urethral stricture: A prospective cohort study
18
作者 Ahmed M.Abdel Gawad Abhijit Patil +3 位作者 Abhishek Singh Arvind P.Ganpule Ravindra B.Sabnis Mahesh R.Desai 《Asian Journal of Urology》 CSCD 2024年第3期480-485,共6页
Objective:To prospectively follow up a cohort of anterior urethral stricture disease patients managed with balloon dilation(BD)for 3 years to evaluate the long-term outcomes and to study factors that contribute to rec... Objective:To prospectively follow up a cohort of anterior urethral stricture disease patients managed with balloon dilation(BD)for 3 years to evaluate the long-term outcomes and to study factors that contribute to recurrence.Methods:This study included men who had urethral BD for significant anterior urethral stricture disease between January 2017 and March 2019.Data about the patient age,stricture characteristics,and recurrence date were recorded,along with information on postoperative indwelling catheter use and operative complications.Furthermore,information about the self-calibration procedure was collected and where available,free flow(FF)measurements during the follow-up period were recorded and analyzed.Success was defined as a lack of symptoms and acceptable FF rates(maximum flow rate>12 mL/s).Results:The final analysis was conducted on 187 patients.The mean follow-up period was 37 months.The long-term overall success rate at the end of our study was 66.8%.Our recurrence rate was 7.4%at 12 months,24.7%at 24 months,and reached 33.2%at the end of our study.The time to recurrence ranged from 91 days to 1635 days,with a mean of 670 days.The stricture-free survival was significantly shorter with lengthy peno-bulbar(p=0.031)and multiple strictures(p=0.015),and in the group of patients who were not committed to self-calibration protocol(p<0.011).However,post-procedural self-calibration was the most important factor that may have decreased the incidence of recurrence(odds ratioZ5.85).Adjuvant self-calibration after BD not only reduced the recurrence rate from 85.4%in the non-self-calibration group to 15.1%in the self-calibration one(p<0.001),but also improved the overall stricture-free survival and FF parameters. 展开更多
关键词 Balloon dilation Internal urethrotomy RECURRENCE self-calibrATION Urethral stricture
暂未订购
Analysis of spatio-temporal evolution of droughts in Luanhe River Basin using different drought indices 被引量:4
19
作者 Kai-yan Wang Qiong-fang Li +3 位作者 Yong Yang Ming Zeng Peng-cheng Li Jie-xiang Zhang 《Water Science and Engineering》 EI CAS CSCD 2015年第4期282-290,共9页
Based on the monthly precipitation and air temperature from 1960 to 1989 in the Luanhe River Basin, the standardized precipitation evapotranspiration index (SPEI) and standardized precipitation index (SPI) at thre... Based on the monthly precipitation and air temperature from 1960 to 1989 in the Luanhe River Basin, the standardized precipitation evapotranspiration index (SPEI) and standardized precipitation index (SPI) at three- and six-month time scales and the self-calibrating Palmer drought severity index (sc-PDSI) were calculated to evaluate droughts in the study area. Temporal variations of the drought severity from 1960 to 1989 were analyzed and compared based on the results of different drought indices, and some typical drought events were identified. Spatial distributions of the drought severity according to the indices were also plotted and investigated. The results reveal the following: the performances of different drought indices are closely associated with the drought duration and the dominant factors of droughts; the SPEI is more accurate than the SPI when both evaporation and precipitation play important roles in drought events; the drought severity shown by the sc-PDSI is generally milder than the actual drought severity from 1960 to 1989; and the evolution of the droughts is usually delayed according to the scPDSI. This study provides valuable references for building drought early warning and mitigation systems in the Luanhe River Basin. 展开更多
关键词 Drought index Drought assessment self-calibrating Palmer drought severity index (sc-PDSI) Standardized precipitation evapotranspiration index(SPEI) Standardized precipitation index (SPI) Luanhe River Basin
在线阅读 下载PDF
Development of photoluminescence metal-organic framework sensors consisting of dual-emission centers
20
作者 Kai Chen Chuande Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第6期823-826,共4页
Incorporation of luminescent moieties into metal-organic frameworks(MOFs) has resulted in numerous photoluminescence(PL) sensors based on chromophore-analyte interactions. However, most of them are only highly sen... Incorporation of luminescent moieties into metal-organic frameworks(MOFs) has resulted in numerous photoluminescence(PL) sensors based on chromophore-analyte interactions. However, most of them are only highly sensitive to few analytes limited by the single luminescent centers in MOFs. To improve the application scopes, dual-emission MOFs were therefore emerged, which can significantly improve the sensitivity by monitoring the relative emission intensity of two luminescent centers. This short review will highlight the recent progress on dual-emission MOFs as highly sensitive sensors for probing of volatile organic molecules(VOMs), picric acid and peroxynitrite, and as self-calibration PL thermometer. 展开更多
关键词 Metal-organic frameworks PHOTOLUMINESCENCE Dual-emission Self-referring self-calibrating
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部