期刊文献+
共找到31,717篇文章
< 1 2 250 >
每页显示 20 50 100
A sensitive electrochemical detection of metronidazole in synthetic serum and urine samples using low-cost screen-printed electrodes modified with reduced graphene oxide and C60 被引量:3
1
作者 Elsa Maria Materon Ademar Wong +2 位作者 Tayane Aguiar Freitas Ronaldo Censi Faria Osvaldo N.Oliveira Jr. 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第5期646-652,共7页
Monitoring the concentration of antibiotics in body fluids is essential to optimizing the therapy and minimizing the risk of bacteria resistance,which can be made with electrochemical sensors tailored with appropriate... Monitoring the concentration of antibiotics in body fluids is essential to optimizing the therapy and minimizing the risk of bacteria resistance,which can be made with electrochemical sensors tailored with appropriate materials.In this paper,we report on sensors made with screen-printed electrodes(SPE)coated with fullerene(C60),reduced graphene oxide(rGO)and Nafion(NF)(C60-rGO-NF/SPE)to determine the antibiotic metronidazole(MTZ).Under optimized conditions,the C60-rGO-NF/SPE sensor exhibited a linear response in square wave voltammetry for MTZ concentrations from 2.5×10^(-7) to 34×10^(-6) mol/L,with a detection limit of 2.1×10^(-7) mol/L.This sensor was also capable of detecting MTZ in serum and urine,with recovery between 94%and 100%,which are similar to those of the standard chromatographic method(HPLC-UV).Because the C60-rGO-NF/SPE sensor is amenable to mass production and allows for MTZ determination with simple principles of detection,it fulfills the requirements of therapeutic drug monitoring programs. 展开更多
关键词 METRONIDAZOLE FULLERENE Reduced graphene oxide screen-printed electrodes Antibiotic
暂未订购
Rapid detection of organophosphorus pesticide residue on Prussian blue modified dual-channel screen-printed electrodes combing with portable potentiostat 被引量:5
2
作者 Qianwei Shi Yuanjie Teng +1 位作者 Yuchao Zhang Wenhan Liu 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第9期1379-1382,共4页
A novel electrochemical method for the rapid detection of organophosphorus pesticide residues was realized on a dual-channel screen-printed electrode (DSPE) that was integrated with a portable smartphone-controlled ... A novel electrochemical method for the rapid detection of organophosphorus pesticide residues was realized on a dual-channel screen-printed electrode (DSPE) that was integrated with a portable smartphone-controlled potentiostat. The two carbon working channels of DSPE were first modified by electrodepositing of Prussian blue. The channels were then modified with acetylcholinesterase (ACHE) via Nation. The inhibition ratio of AChE was detected by comparing the electrical current of acetylthiocholine (ATCh) that was catalyzed by the enzyme electrodes with (channel 1) and without (channel 2) organophosphorus pesticide. Inhibition ratios were related with the negative logarithm of the organophosphorus pesticide (trichlorfon, oxamyl, and isocarbophos) concentrations at optimum experimental conditions (pH 6.9 of electrolyte, 0.2V working potential, 2.5μL AChE modification amount, and 15 min inhibition time). The linear equations were 1%=32.301gC+ 253.3 (R=0.9750) for isocarbophos, I% = 35.991gC+ 270.1 (R = 0.9668) for chlorpyrifos, and 1% = 33.701gC+ 250.5 (R = 0.9606) for trichlorfon. The detection limits were calculated as 10-7 g/mL. Given that the inhibition ratios were only related with pesticide concentration and not with pesticide species, the proposed electrodes and electrometer can rapidly detect universal organophosphorus pesticides and assess pesticide pollution. 展开更多
关键词 Pesticide residue Rapid detection Electrochemical method screen-printed carbon electrodes Portable potentiostat
原文传递
Gold Nanoparticles/Thermochromic Composite Film on Screen-Printed Electrodes for Simultaneous Detection of Protein and Temperature
3
作者 Dorothy Araba Yakoba Agyapong Hanjia Jiang +2 位作者 Xingjia Ni Jingwen Wu Hongjuan Zeng 《Journal of Biomaterials and Nanobiotechnology》 2021年第2期7-19,共13页
In this study, gold nanoparticles and thermochromic composite films modified screen-printed carbon electrodes (TM-AuNPsSPCEs) were developed as a platform for the simultaneous detection of protein and temperature. The... In this study, gold nanoparticles and thermochromic composite films modified screen-printed carbon electrodes (TM-AuNPsSPCEs) were developed as a platform for the simultaneous detection of protein and temperature. The TM-AuNPs composited film had better sensitivity resulting from the gold nanoparticles amplification effect. A phase transition model analysis of TM-AuNPs films found that the TM-AuNPs films had three-phase transition intervals (<45℃, 45℃ to 80℃ and >80℃) which accommodated the temperature requirements for protein denaturation. When used to detect different concentrations of haemoglobin (Hb) solution, the TM-AuNPs modified SPCEs had a better sensitivity in detecting the different concentrations in comparison to TM and AuNP modified SPCEs which showed no clear sensitivity towards the different Hb concentrations. The dual detection and excellent sensitivity show a good application prospect for the study of the TM-AuNPs composite film. 展开更多
关键词 screen-printed Carbon electrodes Gold Nanoparticles Thermochromic Material Simultaneous Detection of Proteins and Temperature
在线阅读 下载PDF
Amperometric Glucose Sensor Based on Batch CuO-Modified Screen-Printed Silver-Carbon Electrodes
4
作者 XIA Haiyan HUANG Yin +6 位作者 YANG Hua WANG Xintian SHI Jianping LIU Lixia FU Yacheng QUAN Changyun LI Suyuan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2025年第1期35-41,共7页
CuO nanoparticles were successfully synthesized via a two-jet electrospun method,and then screen-printed on silver-carbon electrodes,forming CuO-modified Ag-C(CuO/Ag-C)disposable strip electrodes.In natural environmen... CuO nanoparticles were successfully synthesized via a two-jet electrospun method,and then screen-printed on silver-carbon electrodes,forming CuO-modified Ag-C(CuO/Ag-C)disposable strip electrodes.In natural environment condition for glucose detection,the obtained CuO/Ag-C electrodes show a high sensitivity of 540 nA·mM^(-1)·cm^(-2),and a low limit of detection(0.68 mM)in a wide linear response range of 0.68 mM and 3 mM(signal/noise=3),respectively.In addition,the CuO/Ag-C electrodes also exhibit excellent anti-interference,air stability and repeatability.As a result,the fabrication of CuO nanoparticles via an electrospun process and the technique of screen-printed electrodes are of great significance for glucose detection. 展开更多
关键词 electrochemical sensor CuO nanoparticles glucose detection screen-printing technique
原文传递
Accurate cadmium(Ⅱ)detection with single crystalline α-Fe_(2)O_(3) nano-hexagonal modified screen-printed carbon electrode
5
作者 Selvakumar Palanisamy Murugan Velmurugan +4 位作者 G.Bharath Matteo Chiesa Rajesh Madhu Fedor V Kusmartsev Sridharan Balu 《Journal of Environmental Sciences》 2025年第8期635-644,共10页
Even in small concentrations,toxic metals like lead,cadmium,and mercury are dangerous to the environment and human health.Environmental monitoring depends on precisely identifying these heavy metals,particularly cadmi... Even in small concentrations,toxic metals like lead,cadmium,and mercury are dangerous to the environment and human health.Environmental monitoring depends on precisely identifying these heavy metals,particularly cadmium ions(Cd(Ⅱ)).In this study,we present a novel screen-printed carbon electrode(SPCE)modified with single crystallineα-Fe_(2)O_(3)nano-hexagons that functions as a sensor for detecting Cd(Ⅱ).The performance of the fabricated sensor was thoroughly assessed and compared with unmodified SPCE using the voltammetric method.The crystalline structure of the synthesizedα-Fe_(2)O_(3)nano-hexagons was confirmed through XRD,and surface analysis revealed an average diameter and thickness of 86 nm and 9 nm,respectively.Theα-Fe_(2)O_(3)modified SPCE yields a 7-fold enhanced response(at pH 5.0 vs.Ag/AgCl)to Cd(Ⅱ)than bare SPCE.The modified electrode effectively detects Cd(Ⅱ)with a linear response range of up to 333.0μmol/L and a detection limit of 0.65 nmol/L under ideal circumstances.This newly fabricated sensor offers significant potential for environmental monitoring applications by providing outstanding practicality,anti-interference ability,and repeatability for detecting Cd(Ⅱ)in water samples. 展开更多
关键词 α-Fe_(2)O_(3)nano-hexagons screen-printed Carbon electrode Electroanalysis Heavy metal ions detection Cadmium ion sensor Differential pulse voltammetry
原文传递
Noninvasive Label-Free Detection of Cortisol and Lactate Using Graphene Embedded Screen-Printed Electrode 被引量:4
6
作者 Satish K.Tuteja Connor Ormsby Suresh Neethirajan 《Nano-Micro Letters》 SCIE EI CAS 2018年第3期42-51,共10页
A sensitive and specific immunosensor for the detection of the hormones cortisol and lactate in human or animal biological fluids, such as sweat and saliva, was devised using the label-free electrochemical chronoamper... A sensitive and specific immunosensor for the detection of the hormones cortisol and lactate in human or animal biological fluids, such as sweat and saliva, was devised using the label-free electrochemical chronoamperometric technique. By using these fluids instead of blood,the biosensor becomes noninvasive and is less stressful to the end user, who may be a small child or a farm animal.Electroreduced graphene oxide(e-RGO) was used as a synergistic platform for signal amplification and template for bioconjugation for the sensing mechanism on a screenprinted electrode. The cortisol and lactate antibodies were bioconjugated to the e-RGO using covalent carbodiimide chemistry. Label-free electrochemical chronoamperometric detection was used to analyze the response to the desired biomolecules over the wide detection range. A detection limit of 0.1 ng mL^(-1) for cortisol and 0.1 mM for lactate was established and a correlation between concentration and current was observed. A portable, handheld potentiostat assembled with Bluetooth communication and battery operation enables the developed system for point-of-care applications. A sandwich-like structure containing the sensing mechanisms as a prototype was designed to secure the biosensor to skin and use capillary action to draw sweat or other fluids toward the sensing mechanism. Overall, the immunosensor shows remarkable specificity, sensitivity as well as the noninvasive and point-of-care capabilities and allows the biosensor to be used as a versatile sensing platform in both developed and developing countries. 展开更多
关键词 GRAPHENE IMMUNOSENSOR ELECTROCHEMICAL screen-printed electrodes Cortisol sensor
在线阅读 下载PDF
Immobilisation of electrochemically active bacteria on screen-printed electrodes for rapid in situ toxicity biosensing
7
作者 N.Uria E.Fiset +3 位作者 M.Aller Pellitero F.X.Munoz K.Rabaey F.Jdel Campo 《Environmental Science and Ecotechnology》 2020年第3期60-70,共11页
are time-consuming and not sensitive enough.However,bacteria typically connect to electrodes through biofilm formation,leading to problems due to lack of uniformity or long device production times.A suitable immobilis... are time-consuming and not sensitive enough.However,bacteria typically connect to electrodes through biofilm formation,leading to problems due to lack of uniformity or long device production times.A suitable immobilisation technique can overcome these challenges.Still,they may respond more slowly than biofilm-based electrodes because bacteria gradually adapt to electron transfer during biofilm formation.In this study,we propose a controlled and reproducible way to fabricate bacteria-modified electrodes.The method consists of an immobilisation step using a cellulose matrix,followed by an electrode polarization in the presence of ferricyanide and glucose.Our process is short,reproducible and led us to obtain ready-to-use electrodes featuring a high-current response.An excellent shelf-life of the immobilised electrochemically active bacteria was demonstrated for up to one year.After an initial 50% activity loss in the first month,no further declines have been observed over the following 11 months.We implemented our bacteria-modified electrodes to fabricate a lateral flow platform for toxicity monitoring using formaldehyde(3%).Its addition led to a 59% current decrease approximately 20 min after the toxic input.The methods presented here offer the ability to develop a high sensitivity,easy to produce,and long shelf life bacteria-based toxicity detectors. 展开更多
关键词 Microbial biosensor Microbial bioelectrochemical systems Bacteria immobilisation Screen printed electrodes Lateral flow platform Toxicity sensor
原文传递
Anodic voltammetric determination of gemifloxacin using screen-printed carbon electrode 被引量:1
8
作者 Abd-Elgawad Radi Amira Khafagy +1 位作者 Amira El-shobaky Hatem El-mezayen 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第2期132-136,共5页
The electrochemical oxidation behavior and voltammetric assay of gemifloxacin were investigated using differential-pulse and cyclic voltammetry on a screen-printed carbon electrode.The effects of pH,scan rates,and con... The electrochemical oxidation behavior and voltammetric assay of gemifloxacin were investigated using differential-pulse and cyclic voltammetry on a screen-printed carbon electrode.The effects of pH,scan rates,and concentration of the drug on the anodic peak current were studied.Voltammograms of gemifloxacin in Tris-HCl buffer(pH 7.0) exhibited a well-defined single oxidation peak.A differential-pulse voltammetric procedure for the quantitation of gemifloxacin has been developed and suitably validated with respect to linearity,limits of detection and quantification,accuracy,precision,specificity,and robustness.The calibration was linear from 0.5 to 10.0 μM,and the limits of detection and quantification were 0.15 and 5.0 μM.Recoveries ranging from 96.26% to 103.64% were obtained.The method was successfully applied to the determination of gemifloxacin in pharmaceutical tablets without any pre-treatment.Excipients present in the tablets did not interfere in the assay. 展开更多
关键词 screen-printed carbon electrode Voltammetry Gemifloxacin Pharmaceutical analysis
暂未订购
Study of the circuit characteristics between electrodes in a pulsed plasma thruster 被引量:1
9
作者 Jiahao WU Zhiwen WU +5 位作者 Tiankun HUANG Bohan ZHANG Chenwei LI Zhonghao MA Yang GAO Yi BEI 《Plasma Science and Technology》 2025年第6期49-58,共10页
In a pulsed plasma thruster,the voltage distribution between the electrodes is a key factor that influences the ionization process.However,few researchers have conducted in-depth studies of this phenomenon in the past... In a pulsed plasma thruster,the voltage distribution between the electrodes is a key factor that influences the ionization process.However,few researchers have conducted in-depth studies of this phenomenon in the past.Reported here are measurements of the voltage distribution between the plates of a parallel-plate pulsed plasma thruster under different discharge voltages,based on which the variations in the total circuit inductance and resistance as well as those between the plates are calculated.The results show that the time-averaged voltage across the plates accounts for 28.7%-50.4%of the capacitor voltage.As the capacitor initial voltage increases from 1250 V to 2000 V,the voltage across the plates rises,but its proportion relative to the capacitor voltage decreases.For every 250 V increase in the capacitor initial voltage,the average voltage proportion across the plates decreases by approximately 2%-3%.Additionally,the voltage proportion decreases gradually from the end near the propellant outward.The voltage distribution ratio between the plates is correlated with the proportions of the resistance and inductance between the plates relative to the total circuit. 展开更多
关键词 pulsed plasma thruster parallel-plate electrodes circuit characteristics voltage distribution on electrodes
在线阅读 下载PDF
High-Performance Supercapacitor Electrodes from Optimized Single-Step Carbonized Michelia Champaca Biomass 被引量:1
10
作者 Dibyashree Shrestha 《Journal of Environmental & Earth Sciences》 2025年第6期1-22,共22页
This study explores the potential of Michelia champaca wood as a sustainable and locally available precursor for the fabrication of high-performance supercapacitor electrodes.Activated carbons were synthesized through... This study explores the potential of Michelia champaca wood as a sustainable and locally available precursor for the fabrication of high-performance supercapacitor electrodes.Activated carbons were synthesized through single-step carbonization at 400℃ and 500℃(SSC-400℃ and SSC-500℃) and double-step carbonization at 400℃(DSC-400℃),with all samples activated using H_(3)PO_(4).The effects of carbonization stratergy on the structural,morphological,and electrochemical characteristics of the resulting carbon materials were systematically evaluated,using techniques such as BET,SEM,TEM,XRD,Raman scattering,FTIR,CV,GCD and EIS.Among the samples,SSC-400℃ exhibited the best electrochemical performance,achieving a specific capacitance of 292.2 Fg^(-1),an energy density of 6.4 Wh kg^(-1),and a power density of 198.4 W kg^(-1).This superior performance is attributed to its optimized pore structure,improved sur-face functionality and enhanced conductivity.SSC-500℃showed marginally lower performance,whereas,DSC-400℃ displayed the least favorable results,indicating that double-step carbonization process may negatively affect material quality by disrupting the pore network.This work highlights a strong correlation between synthesis methodology and electrochemical efficiency,directly reinforcing the importance of process optimization in electrode material develop-ment.The findings contribute to the broader goal of developing cost-effective,renewable and environmentally friendly energy storage systems.By valorizing biomass waste,the study supports global movements toward green energy technologies and circular carbon economies,offering a viable pathway for sustainable supercapacitor development and practical applications in energy storage devices. 展开更多
关键词 Michelia Champaca Wood Activated Carbon Supercapacitor electrodes CARBONIZATION Sustainable Materials
在线阅读 下载PDF
Frequency optimization for electrodes in implantable brain-computer interfaces 被引量:1
11
作者 CHEN Han LIU Xiangyu +2 位作者 CHENG Jiajun QIN Jiangfan ZHANG Xueli 《Journal of Southeast University(English Edition)》 2025年第3期366-374,共9页
Fully implanted brain-computer interfaces(BCIs)are preferred as they eliminate signal degradation caused by interference and absorption in external tissues,a common issue in non-fully implanted systems.To optimize the... Fully implanted brain-computer interfaces(BCIs)are preferred as they eliminate signal degradation caused by interference and absorption in external tissues,a common issue in non-fully implanted systems.To optimize the design of electroencephalography electrodes in fully implanted BCI systems,this study investigates the penetration and absorption characteristics of microwave signals in human brain tissue at different frequencies.Electromagnetic simulations are used to analyze the power density distribution and specific absorption rate(SAR)of signals at various frequen-cies.The results indicate that lower-frequency signals offer advantages in terms of power density and attenuation coeffi-cients.However,SAR-normalized analysis,which considers both power density and electromagnetic radiation hazards,shows that higher-frequency signals perform better at superficial to intermediate depths.Specifically,at a depth of 2 mm beneath the cortex,the power density of a 6.5 GHz signal is 247.83%higher than that of a 0.4 GHz signal.At a depth of 5 mm,the power density of a 3.5 GHz signal exceeds that of a 0.4 GHz signal by 224.16%.The findings suggest that 6.5 GHz is optimal for electrodes at a depth of 2 mm,3.5 GHz for 5 mm,2.45 GHz for depths of 15-20 mm,and 1.8 GHz for 25 mm. 展开更多
关键词 brain-computer interfaces electromagnetic simulation electroencephalography electrodes power den-sity specific absorption rate
在线阅读 下载PDF
High volumetric-energy-density flexible supercapacitors based on PEDOT:PSS incorporated with carbon quantum dots hybrid electrodes 被引量:1
12
作者 Dinh Cung Tien Nguyen Seonghan Kim +2 位作者 Bo-Seok Kim Sejung Kim Soo-Hyoung Lee 《Journal of Materials Science & Technology》 2025年第20期1-10,共10页
Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate)(PEDOT:PSS)is a highly successful conductive polymer utilized as an electrode material in energy storage units for portable and wearable electronic de-vices.Neve... Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate)(PEDOT:PSS)is a highly successful conductive polymer utilized as an electrode material in energy storage units for portable and wearable electronic de-vices.Nevertheless,employing PEDOT:PSS in supercapacitors(SC)in its pristine state presents challenges due to its suboptimal electrochemical performance and operational instability.To surmount these limita-tions,PEDOT:PSS has been integrated with carbon-based materials to form flexible electrodes,which ex-hibit physical and chemical stability during SC operation.We developed a streamlined fabrication process for high-performance SC electrodes composed of PEDOT:PSS and carbon quantum dots(CQDs).The CQDs were synthesized under microwave irradiation,yielding green-and red-light emissions.Through optimiz-ing the ratios of CQDs to PEDOT:PSS,the SC electrodes were prepared using a spray-coating technique,marking a significant improvement in device performance with a high volumetric capacitance(104.10 F cm-3),impressive energy density(19.68 Wh cm^(-3)),and excellent cyclic stability,retaining~85% of its original volumetric capacitance after 15,000 repeated GCD cycles.Moreover,the SCs,when utilized as a flexible substrate,demonstrated the ability to maintain up to~85% of their electrochemical performance even after 3,000 bending cycles(at a bending angle of 60°).These attributes render this hybrid composite an ideal candidate for a lightweight smart energy storage component in portable and wearable electronic technologies. 展开更多
关键词 PEDOT:PSS Carbon quantum dots Hybrid electrode SUPERCAPACITOR Flexible power sources
原文传递
Multicomponent Gd_(1−x)Sm_(x)Ba_(0.5)Sr_(0.5)CoCuO_(5+δ) double perovskites as oxygen electrodes for solid oxide cells:Effect of chemical composition and electrospun morphology 被引量:1
13
作者 Jacek Winiarski Piotr Winiarz Konrad Świerczek 《International Journal of Minerals,Metallurgy and Materials》 2025年第11期2628-2638,共11页
Multicomponent Gd_(1−x)Sm_(x)Ba_(0.5)Sr_(0.5)CoCuO_(5+δ)double perovskites are optimized for application in terms of chemical composi-tion and morphology for the use as oxygen electrodes in solid oxide cells.Structur... Multicomponent Gd_(1−x)Sm_(x)Ba_(0.5)Sr_(0.5)CoCuO_(5+δ)double perovskites are optimized for application in terms of chemical composi-tion and morphology for the use as oxygen electrodes in solid oxide cells.Structural studies of other physicochemical properties are con-ducted on a series of materials obtained by the sol-gel method with different ratios of Gd and Sm cations.It is documented that changing the x value,and the resulting adjustment of the average ionic radius,have a significant impact on the crystal structure,stability,as well as on the total conductivity and thermomechanical properties of the materials,with the best results obtained for the Gd_(0.75)Sm_(0.2)5Ba_(0.5)Sr_(0.5)CoCuO_(5+δ)composition.Oxygen electrodes are prepared using the selected compound,allowing to obtain low polarization resistance values,such as 0.086Ω·cm^(2)at 800℃.Systematic studies of electrocatalytic activity are conducted using La_(0.8)Sr_(0.2)Ga_(0.8)Mg_(_(0.2))O_(3−δ)as the electrolyte for all electrodes,and Ce_(0.8)Gd_(0.2)O_(2−δ)electrolyte for the best performing Gd_(0.75)Sm_(0.2)5Ba_(0.5)Sr_(0.5)CoCuO_(5+δ)electrodes.The electrochemical data are analyzed using the distribution of relaxation times method.Also,the influence of the preparation method of the electrode material is in-ve`stigated using the electrospinning technique.Finally,the performance of the Gd_(0.75)Sm_(0.2)5Ba_(0.5)Sr_(0.5)CoCuO_(5+δ)electrodes is tested in a Ni-YSZ(yttria-stabilized zirconia)anode-supported cell with a Ce_(0.8)Gd_(0.2)O_(2−δ)buffer layer,in the fuel cell and electrolyzer operating modes.With the electrospun electrode,a power density of 462 mW·cm^(−2)is obtained at 700℃,with a current density of ca.0.2 A·cm^(−2)at 1.3 V for the electrolysis at the same temperature,indicating better performance compared to the sol-gel-based electrode. 展开更多
关键词 multicomponent oxides double perovskites morphology modification ELECTROSPINNING oxygen electrodes solid oxide cells
在线阅读 下载PDF
MEC-AD Leveraging Derived Carbon for Energy-Efficient Methane Production:Insights into Electrodes,Accelerants,and Methanogenic Approaches
14
作者 ZHANG Xiaoxue WANG Kaijun +5 位作者 GAO Yangyang Yasir Abbas Muhammad Saqlain Jamil PENG Cheng LUO Han YUN Sining 《硅酸盐学报》 北大核心 2025年第12期3740-3760,共21页
Introduction The generation of biological wastes such as cow dung and aloe vera waste(AVW)causes a serious ecological pollution.The microbial electrolytic cell coupled with anaerobic digestion(MEC-AD)system can make a... Introduction The generation of biological wastes such as cow dung and aloe vera waste(AVW)causes a serious ecological pollution.The microbial electrolytic cell coupled with anaerobic digestion(MEC-AD)system can make a rational utilization of these biodegradable organic wastes,which is of vital importance for alleviating environmental deterioration and reducing resource waste.Electrode materials and accelerants are the two major factors that affect methane production in the MEC-AD system.They affect microbial attachment and electron transfer in the MEC-AD system.Bio-based carbon materials are carbon materials prepared from biomass as raw materials.They have characteristics such as a rich pore structure,good chemical stability,biocompatibility,and controllable surface properties,which can be used as accelerants and electrodes in the MEC-AD system to optimize its performance.This study was to investigate the influence of biomass-derived carbon as an electrode and accelerant on the performance of the MEC-AD system,and the mechanism for increasing the production of biogas and methane was also analyzed,thus providing a basis for the multifunctional application of biomass-derived carbon in the MEC-AD system.Methods A series of experimental methods were adopted to study the MEC-AD system.Two types of bio-based carbon,i.e.,aloe vera waste derived spherical carbon(AVW-SC)and porous carbon(AVW-PC),were synthesized via hydrothermal carbonization.The raw AVW material was washed with water,dried,ground,and subjected to hydrothermal treatment to obtain AVW-SC.After activating AVW-SC with KOH,it was carbonized in a tube furnace to obtain AVW-PC.In the preparation of the electrodes,bio-based carbon(AVW-SC and AVW-PC)was mixed with 5%polytetrafluoroethylene powder in ethanol and deionized water,and then ground in a ball mill for 4 h to form a slurry.The slurry was evenly sprayed on the Ti mesh,dried and sintered in N2 atmosphere at 360℃to obtain Ti-SC and Ti-PC electrodes.Four groups of experiments were conducted to determine the optimal voltage,compare different carbon electrodes,and explore the optimal coating amount.The MEC-AD reactor adopted 500 mL wide-mouthed glass bottles with a working volume of 400 mL.Each MEC-AD system received a co-substrate mixture of cattle dung and aloe vera waste and inoculum of sewage sludge in a mass ratio of 3:7.Afterward,they were placed at(36±1)℃for 35 d.The biogas was collected by a water displacement method.The materials were analyzed by characterization techniques such as X-ray diffraction(XRD)and scanning electron microscopy(SEM),and electrochemical tests were conducted on different electrodes.The composition,pH,TS,VS,TCOD and nutrient content of biogas were analyzed by standard chemical methods.Microbial community analysis was conducted using high-throughput sequencing technology.The modified Gompertz model was adopted to predict the kinetic parameters,and the coulombic efficiency and methane recovery rate were calculated according to a specific formula.Results and discussion The result shows that AVW-SC is spherical and closely aggregated,while AVW-PC has a three-dimensional network structure,with average pore diameter of 9.77 nm.The electron exchange capacity(EEC)of AVW-PC(i.e.,0.75μmol·e-/g)is higher than that of AVW-SC(i.e.,0.15μmol·e-/g),indicating a better electron exchange capacity.These results indicate that AVW-PC provides more substrate and bacteria accumulation sites,and has better electron-donating and electron-accepting ability,thus improving the digestion efficiency.In the MEC-AD system,using Ti mesh as an electrode,the effect of different voltages(i.e.,0,0.4,0.6,0.8 V and 1.2 V)on the system performance is investigated,obtaining the optimum biogas production and organic matter degradation rate at 0.8 V.AVW-SC and AVW-PC are respectively coated on Ti mesh as electrodes.The results show that the MEC-AD system with AVW-PC coated Ti mesh as the electrode has a better performance.The electrochemical analysis shows that the electrode coated with AVW-PC has a larger specific capacitance and a smaller charge transfer resistance,indicating that AVW-PC can improve the electrochemical properties and electron transfer ability of MEC-AD system.The influence of coating amount(i.e.,0.025,0.05,0.10,0.15,and 0.20 g)of AVW-PC on the MEC-AD system is investigated.At a coating amount of AVW-PC of 0.1 g,the cumulative biogas production and methane content of the Ti_(0.8)-PC_90.1) group both reach the maximum values.Different doses of AVW-PC(i.e.,0.10%,0.15%,0.20%,and 0.25%)are added as accelerants in Ti_(0.8)-PC_90.1).At the addition amount of AVW-PC of 0.20%,the Ti_(0.8)-PC_90.1)/PC0.2 group performs the optimum biogas production(i.e.,633.63 mL/g VS),methane content(i.e.,65.85%),and total nutrient content of biogas residue(i.e.,42.30 g/kg).In Ti_(0.8)-PC_90.1)/PC0.2,Bacteroidales,Pseudomonadales,Oscillospirales,Methanobacteraceae,Methanospirillaceae,Methanosarcinacea and Methanosaetaceae significantly increase.The increase in microbial diversity promotes interspecific hydrogen transfer(IHT),interspecific acetic transfer(IAT),and direct interspecific electron transfer(DIET),thereby enhancing methanogenic efficiency.Conclusions AVW-SC and AVW-PC were utilized as electrodes and accelerants to enhance methane yield in MEC-AD system.The Ti mesh electrode coated with different concentrations of AVW-PC achieved the optimal biogas production at 0.8 V.Specifically,the Ti_(0.8)-PC_90.1) combination could generate the maximum total amount of biogas and methane proportion.The Ti_(0.8)-PC_90.1)/PC0.2 combination exhibited the optimum performance(i.e.,biogas yield of 633.63 mL/g VS,methane content of 65.85%and total nutritional content of 42.30 g/kg).High abundances of Bacteroidales,Pseudomonadales,Oscillospirales,Methanobacteraceae,Methanospirillaceae,Methanosarcinaceae,and Methanosaetaceae appeared in the Ti_(0.8)-PC_90.1)/PC0.2 group,compared to other groups.In addition,an increased microbial diversity led to an enhanced methane production through processes like DIET.This research could highlight the potential significance of AVW-PC as both electrode and accelerator for increasing methane production and provide a perspective for improving MEC-AD performance through multiple applications of biomass-derived carbon. 展开更多
关键词 aloe vera waste biomass-derived carbon electrode ACCELERANT biogas production
原文传递
Study on Affecting Factors of the Consistency of Printed Electrodes Based on an Online Pressure Monitoring System
15
作者 CAI Zi-mu GU Jin-tao +2 位作者 CHENG Guang-kai XU Guang-yi LI Yan 《印刷与数字媒体技术研究》 北大核心 2025年第2期91-97,共7页
In order to address the current inability of screen printing to monitor printing pressure online,an online printing pressure monitoring system applied to screen printing machines was designed in this study.In this stu... In order to address the current inability of screen printing to monitor printing pressure online,an online printing pressure monitoring system applied to screen printing machines was designed in this study.In this study,the consistency of printed electrodes was measured by using a confocal microscope and the pressure distribution detected by online pressure monitoring system was compared to investigate the relationship.The results demonstrated the relationship between printing pressure and the consistency of printed electrodes.As printing pressure increases,the ink layer at the corresponding position becomes thicker and that higher printing pressure enhances the consistency of the printed electrodes.The experiment confirms the feasibility of the online pressure monitoring system,which aids in predicting and controlling the consistency of printed electrodes,thereby improving their performance. 展开更多
关键词 Printing pressure Consistency of printed electrodes Screen printing Online monitoring
在线阅读 下载PDF
Novel Screen-Printed All-Solid-State Copper(II)-Selective Electrode for Mobile Environmental Analysis 被引量:1
16
作者 Johannes Schwarz Kathrin Trommer Michael Mertig 《American Journal of Analytical Chemistry》 2016年第7期525-532,共9页
Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicabilit... Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicability of the ion-selective electrode (ISE) have been proved by potentiometric investigations. Conducting polymers were used as intermediate layers and as solid contacts between the ion-selective membrane and the graphite transducer. The ion-complexing reagent 2-mercapto-benzoxazole was incorporated into poly(vinyl chloride) membranes. In the concentration range 10<sup>-6</sup> - 10<sup>-2</sup> mol/L, the ISE exhibited a linear Nernstian potential response to copper(II) with an average slope value of 28 mV/decade. The detection limit was 3 × 10<sup>-7</sup> mol/L. The electrode exhibits a short response time (<10 s) and can be used in the range of pH = 3 - 7. Selectivity coefficents against certain interfering ions are investigated. The life time of the electrode under laboratory conditions was approximately 12-month. The electrode was applied in the investigation of different aqueous environmental samples and the electrode characteristics were described. The copper(II) ASS electrode has also successfully been used in potentiometric, complexometric titrations with ethylenediaminetetraacetic acid. 展开更多
关键词 All-Solid-State Copper(II)-Selective electrode Conducting Polymers Potentiometric Titration Environmental Samples
在线阅读 下载PDF
Evolution of the volume expansion of SiO/C composite electrodes in lithium-ion batteries during aging cycles
17
作者 Haosong Yang Kai Sun +2 位作者 Xueyan Li Peng Tan Lili Gong 《中国科学技术大学学报》 北大核心 2025年第2期27-33,26,I0001,共9页
As a negative electrode material for lithium-ion batteries,silicon monoxide(SiO)suffers from dramatic volume changes during cycling,causing excessive stress within the electrode and resulting in electrode deformation ... As a negative electrode material for lithium-ion batteries,silicon monoxide(SiO)suffers from dramatic volume changes during cycling,causing excessive stress within the electrode and resulting in electrode deformation and fragmentation.This ultimately leads to a decrease in cell capacity.The trends of volume expansion and capacity change of the SiO/graphite(SiO/C)composite electrode during cycling were investigated via in situ expansion monitoring.First,a series of expansion test schemes were designed,and the linear relationship between negative electrode expansion and cell capacity degradation was quantitatively analyzed.Then,the effects of different initial pressures on the long-term cycling performance of the cell were evaluated.Finally,the mechanism of their effects was analyzed by scanning electron microscope.The results show that after 50 cycles,the cell capacity decreases from 2.556 mAh to 1.689 mAh,with a capacity retention ratio(CRR)of only 66.08%.A linear relationship between the capacity retention ratio and thickness expansion was found.Electrochemical measurements and scanning electron microscope images demonstrate that intense stress inhibits the lithiation of the negative electrode and that the electrode is more susceptible to irreversible damage during cycling.Overall,these results reveal the relationship between the cycling performance of SiO and the internal pressure of the electrode from a macroscopic point of view,which provides some reference for the application of SiO/C composite electrodes in lithium-ion batteries. 展开更多
关键词 lithium-ion batteries in situ expansion measurement initial stress cycle life SiO/C composite electrode
在线阅读 下载PDF
A wearable sensor device based on screen-printed chip with biofuel cell-driven electrochromic display for noninvasive monitoring of glucose concentration
18
作者 Kezuo Di Jie Wei +6 位作者 Lijun Ding Zhiying Shao Junling Sha Xilong Zhou Huadong Heng Xujing Feng Kun Wang 《Chinese Chemical Letters》 2025年第2期413-417,共5页
Wearable flexible sensor devices have the characteristics of lightweight and miniaturization.Currently,power supply and detection components limit the portability of wearable flexible sensor devices.Meanwhile,conventi... Wearable flexible sensor devices have the characteristics of lightweight and miniaturization.Currently,power supply and detection components limit the portability of wearable flexible sensor devices.Meanwhile,conventional liquid electrolytes are unsuitable for the integration of sensing devices.To address these constraints,wearable biofuel cells and flexible electrochromic displays have been introduced,which can improve integration with other devices,safety,and color-coded display data.Meanwhile,electrode chips prepared through screen printing technology can further improve portability.In this work,a wearable sensor device with screen-printed chips was constructed and used for non-invasive detection of glucose.Agarose gel electrolytes doped with PDA-CNTs were prepared,and the mechanical strength and moisture retention were significantly improved compared with traditional gel electrolytes.Glucose in interstitial fluid was non-invasive extracted to the skin surface using reverse iontophoresis.As a biofuel for wearable biofuel cells,glucose drives self-powered sensor and electrochromic display to produce color change,allowing for visually measurement of glucose levels in body fluids.Accurate detection results can be visualized by reading the RGB value with a cell phone. 展开更多
关键词 Wearable flexible sensor device Electrochromic display VISUALIZATION Biofuel cell screen-printed chip
原文传递
A novel logging method for detecting highly resistive formations in oil-based mud using high-frequency electrodes
19
作者 Kang-Kang Wu Lei Wang +1 位作者 Shao-Gui Deng Xue-Wen Kou 《Petroleum Science》 2025年第5期1946-1958,共13页
The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel l... The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel logging method for detection of high-resistance formations in OBM using highfrequency electrodes. The method addresses the issue of shallow depth of investigation(DOI) in existing electrical logging instruments, while simultaneously ensuring the vertical resolution. Based on the principle of current continuity, the total impedance of the loop is obtained by equating the measurement loop to the series form of a capacitively coupled circuit. and its validity is verified in a homogeneous formation model and a radial two-layer formation model with a mud standoff. Then, the instrument operating frequency and electrode system parameters were preferentially determined by numerical simulation, and the effect of mud gap on impedance measurement was investigated. Subsequently, the DOI of the instrument was investigated utilizing the pseudo-geometric factor defined by the real part of impedance. It was determined that the detection depth of the instrument is 8.74 cm, while the effective vertical resolution was not less than 2 cm. Finally, a focused high-frequency electrode-type instrument was designed by introducing a pair of focused electrodes, which effectively enhanced the DOI of the instrument and was successfully deployed in the Oklahoma formation model. The simulation results demonstrate that the novel method can achieve a detection depth of 17.40 cm in highly-resistive formations drilling with OBM, which is approximately twice the depth of detection of the existing oil-based mud microimager instruments. Furthermore, its effective vertical resolution remains at or above 2 cm,which is comparable to the resolution of the existing OBM electrical logging instrument. 展开更多
关键词 Oil-based mud Highly-resistive High-frequency electrode Bulking electrode Depth of investigation
原文传递
Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Entrapped in Titania Sol-Gel Film on Screen-Printed Electrode
20
作者 Reza E. Sabzi Fereshteh Rasouli Farshad Kheiri 《American Journal of Analytical Chemistry》 2013年第11期607-615,共9页
We report the fabrication of disposable and flexible Screen-Printed Electrodes (SPEs). This new type of screen-printed electrochemical platform consists of Ag nanoparticles (AgNPs) and graphite composite. For this pur... We report the fabrication of disposable and flexible Screen-Printed Electrodes (SPEs). This new type of screen-printed electrochemical platform consists of Ag nanoparticles (AgNPs) and graphite composite. For this purpose, silver nanoparticles were first synthesized by a chemical reduction method. The morphology and structure of the AgNPs were analyzed using a Scanning Electron Microscope (SEM) and UV-Visible spectroscopy. Graphite was chosen as the working electrode material for the fabrication of a thick-film. The fabrication of a screen-printed hydrogen peroxide biosensor consisting of three electrodes on a polyethylene terephthalate (PET) substrate was performed with a spraying approach (working, counter and reference: enzyme electrode, graphite, pseudo reference: Ag/AgCl). This biosensor was fabricated by immobilizing the peroxidase enzyme (HRP) in a Titania sol-gel membrane which was obtained through a vapor deposition method. The biosensor had electrocatalytic activity in the reduction of H2O2 with linear dependence on H2O2 concentration in the range of 10-5 to 10-3 M;the detection limit was 4.5 × 10-6 M. 展开更多
关键词 screen-printed electrodE Ag NANOPARTICLE TITANIA SOL-GEL BIOSENSOR
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部