AIM:To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux(DGR).METHODS:The study contained 99 patients with DGR and 70 heal...AIM:To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux(DGR).METHODS:The study contained 99 patients with DGR and 70 healthy volunteers who made up the control group.The diagnosis was based on the combination of several objective arguments:a long history of gastric symptoms(i.e.,nausea,epigastric pain,and/or bilious vomiting) poorly responsive to medical treatment,gastroesophageal reflux symptoms unresponsive to protonpump inhibitors,gastritis on upper gastrointestinal(GI) endoscopy and/or at histology,presence of a bilious gastric lake at > 1 upper GI endoscopy,pathologic 24-h intragastric bile monitoring with the Bilitec device.Gas-tric juice was aspirated in the GI endoscopy and total bile acid(TBA),total bilirubin(TBIL) and direct bilirubin(DBIL) were tested in the clinical laboratory.Continuous data of gastric juice were compared between each group using the independent-samples Mann-Whitney U-test and their relationship was analysed by Spearman's rank correlation test and Fisher's linear discriminant analysis.Histopathology of DGR patients and 23 patients with chronic atrophic gastritis was compared by clinical pathologists.Using the Independent-samples Mann-Whitney U-test,DGR index(DGRi) was calculated in 28 patients of DGR group and 19 persons of control group who were subjected to hepatobiliary scintigraphy.Receiver operating characteristic curve was made to determine the sensitivity and specificity of these two methods in the diagnosis of DGR.RESULTS:The group of patients with DGR showed a statistically higher prevalence of epigastric pain in comparison with control group.There was no significant difference between the histology of gastric mucosa with atrophic gastritis and duodenogastric reflux.The bile acid levels of DGR patients were significantly higher than the control values(Z:TBA:-8.916,DBIL:-3.914,TBIL:-6.197,all P < 0.001).Two of three in the DGR group have a significantly associated with each other(r:TBA/DBIL:0.362,TBA/TBIL:0.470,DBIL/TBIL:0.737,all P < 0.001).The Fisher's discriminant function is followed:Con:Y = 0.002TBA + 0.048DBIL + 0.032TBIL 0.986;Reflux:Y = 0.012TBA + 0.076DBIL + 0.089TBIL-2.614.Eighty-four point zero five percent of original grouped cases were correctly classified by this method.With respect to the DGR group,DGRi were higher than those in the control group with statistically significant differences(Z =-5.224,P < 0.001).Twenty eight patients(59.6%) were deemed to be duodenogastric reflux positive by endoscopy,as compared to 37 patients(78.7%) by hepatobiliary scintigraphy.CONCLUSION:The integrated use of intragastric bile acid examination and scintigraphy can greatly improve the sensitivity and specificity of the diagnosis of DGR.展开更多
AIM:To investigate the diagnostic accuracy of hepatobiliary scintigraphy(HBS) in detecting biliary strictures in living donor liver transplantation(LDLT) patients.METHODS:We retrospectively reviewed 104 adult LDLT rec...AIM:To investigate the diagnostic accuracy of hepatobiliary scintigraphy(HBS) in detecting biliary strictures in living donor liver transplantation(LDLT) patients.METHODS:We retrospectively reviewed 104 adult LDLT recipients of the right hepatic lobe with duct-toduct anastomosis,who underwent HBS and cholangiography.The HBS results were categorized as normal,parenchymal dysfunction,biliary obstruction,or bile leakage without re-interpretation.The presence of biliary strictures was determined by percutaneous cholangiography or endoscopic retrograde cholangiopancreatography(ERCP).RESULTS:In 89 patients with biliary strictures,HBS showed biliary obstruction in 50 and no obstruction in 39,for a sensitivity of 56.2%.Of 15 patients with no biliary strictures,HBS showed no obstruction in 11,for a specificity of 73.3%.The positive predictive value(PPV) was 92.6%(50/54) and the negative predictive value(NPV) was 22%(11/50).We also analyzed the diagnostic accuracy of the change in bile duct size.The sensitivity,NPV,specificity,and PPV were 65.2%,27.9%,80% and 95%,respectively.CONCLUSION:The absence of biliary obstruction on HBS is not reliable.Thus,when post-LDLT biliary strictures are suspected,early ERCP may be considered.展开更多
Noninvasive diagnoses of nonalcoholic fatty-liver disease(NAFLD) involve the use of serologic markers and imaging methods, such as conventional ultrasonography(US),computed tomography, and magnetic resonance imaging. ...Noninvasive diagnoses of nonalcoholic fatty-liver disease(NAFLD) involve the use of serologic markers and imaging methods, such as conventional ultrasonography(US),computed tomography, and magnetic resonance imaging. Although these methods are reliable for the noninvasive detection of moderate to severe fatty changes in the liver, they are not reliable for detecting nonalcoholic steatohepatitis(NASH) and fibrosis. New imaging technologies, such as US-based transient elastography, acoustic radiation force impulse and magnetic resonancebased elastography, can reportedly be used to determine the severity of liver fibrosis associated with NASH. In this context, the field of nuclear medicine through liver scintigraphy has recently been proposed, and is being explored for use in the diagnosis of NASH. More importantly, nuclear medicine may contribute to the distinction between simple steatosis and NASH. For example, the enhanced release of cytokines and the decrease in the phagocytic activity of Kupffer cells play important roles in the pathogenesis of NASH. Removal of technetium-99 m colloid from circulation by Kupffer cell phagocytosis therefore provides a valuable imaging technique. Thus, nuclear medicine is poised to provide useful tools for the evaluation of patients with NAFLD. However, the evidence is still scarce, and more studies with larger samples are needed to identify their role before they are used in clinical practice.展开更多
In order to investigate the clinical significance of 99mTc-Tetrofosmin (TF) scintigraphy in the evaluation of lung cancer and mediastinal lymphoid node involvement, 33 patients with pulmo- nary neoplasmas were subje...In order to investigate the clinical significance of 99mTc-Tetrofosmin (TF) scintigraphy in the evaluation of lung cancer and mediastinal lymphoid node involvement, 33 patients with pulmo- nary neoplasmas were subjected to both 99mTc-TF scintigraphies and CT scans in one week before their operations or puncturations. All the images were judged visually and the emission images were analyzed with semi-quantitative methods in addition. The results of each group were compared. There was marked difference in target/non-target (T/N) ratio between the lung cancer group and the benign lesion group (P〈0.001). Moreover, in the lung cancer group, T/N ratio in tomographies was signifi- cantly higher than that in planar images (P〈0.01). The sensitivity and accuracy of semi-quantitative analysis in 99mTc-TF SPECT were significantly higher than those of CT in the diagnosis of pulmonary neoplasmas (P〈0.05 and P〈0.01 respectively), so was the sensitivity of 99mTc-TF SPECT vs CT in the diagnosis of mediastinal lymphoid node metastasis (P〈0.05). It was also found that epidermoid squamous cell carcinomas and adenocarcinomas had a higher T/N ratio than in small cell carcinomas (P〈0.05), and 2 h washout rate (WR) of adenocarcinomas was higher than that of epidermoid squamous cell carcinomas (P〈0.05). In conclusion, 99mTc-TF scintigraphy showed a favorable diag- nostic accuracy in appraising lung cancers and mediastinal lymph node metastases. Furthermore semi-quantitative technology can improve the accuracy, and is potential to offer some information about histological type of the cancer tissue. Therefore, 99mTc-TF scintigraphy will be a useful tool in the diagnosis and staging of lung cancer.展开更多
AIM: To evaluate the role of pentavalent Tc-99m dimercaptosuccinic acid [Tc-99m (V) DMSA] in the diagnosis of ischemic colitis. METHODS: Fourteen patients with endoscopically and histologically confirmed ischemic coli...AIM: To evaluate the role of pentavalent Tc-99m dimercaptosuccinic acid [Tc-99m (V) DMSA] in the diagnosis of ischemic colitis. METHODS: Fourteen patients with endoscopically and histologically confirmed ischemic colitis were included in the study. Tc-99m (V) DMSA scintigraphy was performed within 2 d after colonoscopy. Images were considered positive when an area of increased activity was observed in the region of interest and negative when no abnormal tracer uptake was detected. RESULTS: In 3 out of the 14 patients, Tc-99m (V) DMSA images showed moderate activity in the bowel. The scintigraphic results corresponded with the endoscopic findings. In the other 11 patients, no abnormal tracer uptake was detected in the abdomen. CONCLUSION: Besides the limited number of patients, Tc-99m (V) DMSA could not be considered as a useful imaging modality for the evaluation of ischemic colitis.展开更多
AIM: To determine the role of scintigraphy in patients with gastrointestinal (GI) bleeding of unknown Iocalisation. METHODS: We performed retrospective analyses on 92 patients receiving scintigraphies from 1993 to...AIM: To determine the role of scintigraphy in patients with gastrointestinal (GI) bleeding of unknown Iocalisation. METHODS: We performed retrospective analyses on 92 patients receiving scintigraphies from 1993 to 2000 in the University of Regensburg hospital, which were done for Iocalisation of GI bleeding as a diagnostic step after an unsuccessful endoscopy. In addition to the scintigraphies, further diagnostic steps such as endoscopy, angiography or operations were performed. In some of the scintigraphies with negative results, a provocation test for bleeding with heparinisation was carried out. RESULTS: 73% of all scintigraphies showed a positive result. In 4.5% of the positive results, the source was located in the stomach, in 37% the source was the small bowel, in 25% the source was the right colon, in 4.5% the source was the left colon, and in 20% no clear Iocalisation was possible. Only 4% of all scintigraphies were false positive. A reliable positive scintigraphy was independent of the age of the examined patient. A provocation test for bleeding with heparin resulted in an additional 46% of positive scintigraphies with a reliable Iocalisation in primary negative scintigraphies. CONCLUSION- Our results show that scintigraphy and scintigraphy with heparin provocation tests are reliable procedures. They enable a reliable Iocalisation in about half of the obscure GI-bleeding cases. Scintigraphy is superior to angiography in locating a bleeding. It is shown that even in the age of video capsule endoscopy and double-balloon enteroscopy, scintigraphy provides a reliable and directed localization of GI bleeding and offers carefully targeted guidance for other procedures.展开更多
AIM To evaluate the agreement of multichannel intraluminal impedance-p H monitoring(MII-p HM) and gastroesophageal reflux scintigraphy(GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five co...AIM To evaluate the agreement of multichannel intraluminal impedance-p H monitoring(MII-p HM) and gastroesophageal reflux scintigraphy(GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspectedgastroesophageal reflux disease(GERD) underwent 24-h combined MII-p HM recording and one hour radionuclide scintigraphy during the course of the MIIpH M study. Catheters with 6 impedance channels and 1 p H sensor were placed transnasally. Impedance and p H data analysis were performed automatically and manually. For impedance monitoring, reflux was defined as a retrograde 50% drop in impedance, starting distally and propagating retrogradely to at least the next two more proximal measuring channels. Reflux index(RI, percentage of the entire record that esophageal p H is < 4.0) greater than 4.2% for p HM and number of refluxes more than 50 for 24 h for MII were accepted as positive test results. At scintigraphy, 240 frames of 15 seconds duration were acquired in the supine position. Gastroesophageal reflux was defined as at least one reflux episode in the esophagus. After scintigraphic evaluation, impedance-pH recordings and scintigraphic images were evaluated together and agreement between tests were evaluated with Cohen's kappa.RESULTS Sufficient data was obtained from 60(80%) patients(34 male, 56.7%) with a mean age of 8.7 ± 3.7 years(range: 2.5-17.3 years; median: 8.5 years). Chronic cough, nausea, regurgitation and vomiting were the most frequent symptoms. The mean time for recording of MII-pH M was 22.8 ± 2.4 h(range: 16-30 h; median: 22.7 h). At least one test was positive in 57(95%) patients. According to diagnostic criteria, GERD was diagnosed in 34(57.7%), 44(73.3%), 47(78.3%) and 51(85%) patients by means of p HM, MII, GES and MII-p HM, respectively. The observed percentage agreements/κ values for GES and p HM, GES and MII, GES and MII-p HM, and MII and p HM are 48.3%/-0.118; 61.7%/-0.042; 73.3%/0.116 and 60%/0.147, respectively. There was no or slight agreement between GES and p HM alone, MII alone or MII-p HM. p H monitoring alone missed 17 patients compared to combined MII-p HM. The addition of MII to pH monitoring increased the diagnosis rate by 50%.CONCLUSION No or slight agreement was found among p H monitoring, MII monitoring, MII-pH monitoring and GES for the diagnosis of gastroesophageal reflux disease.展开更多
AIM: To investigate potential roles of per rectal portal scintigraphy in diagnosis of esophageal varices and predicting the risk of bleeding.METHODS: Fifteen normal subjects and fifty cirrhotic patients with endoscopi...AIM: To investigate potential roles of per rectal portal scintigraphy in diagnosis of esophageal varices and predicting the risk of bleeding.METHODS: Fifteen normal subjects and fifty cirrhotic patients with endoscopically confirmed esophageal varices were included. Patients were categorized into bleeder and non-bleeder groups according to history of variceal bleeding. All had completed per rectal portal scintigraphy using 99mTechnetium pertechnetate. The shunt index was calculated from the ratio of 99mTechnetium pertechnetate in the heart and the liver. Data were analyzed using Student’s t-test and receiver operating characteristics.RESULTS: Cirrhotic patients showed a higher shunt index than normal subjects (63.80 ± 25.21 vs 13.54 ± 6.46, P < 0.01). Patients with variceal bleeding showed a higher shunt index than those without bleeding (78.45 ± 9.40 vs 49.35 ± 27.72, P < 0.01). A shunt index of over 20% indicated the presence of varices and that of over 60% indicated the risk of variceal bleeding.CONCLUSION: In cirrhotic patients, per rectal portal scintigraphy is a clinically useful test for identifying esophageal varices and risk of variceal bleeding.展开更多
The diagnosis of inflammatory bowel disease(IBD) depends on direct endoscopic visualization of the colonic and ileal mucosa and the histological study of the obtained samples.Radiological and scintigraphic methods are...The diagnosis of inflammatory bowel disease(IBD) depends on direct endoscopic visualization of the colonic and ileal mucosa and the histological study of the obtained samples.Radiological and scintigraphic methods are mainly used as an adjunct to endoscopy.In this review,we focus on the diagnostic potential of nuclear medicine procedures.The value of all radiotracers is described with special reference to those with greater experience and more satisfactory results.Tc-99m hexamethylpropylene amine oxime white blood cells remain a widely acceptable scintigraphic method for the diagnosis of IBD,as well as for the evaluation of disease extension and severity.Recently,pentavalent Tc-99m dimercaptosuccinic acid has been recommended as an accurate variant and a complementary technique to endoscopy for the follow-up and assessment of disease activity.Positron emission tomography alone or with computed tomography using fluorine-18 fluorodeoxyglucose appears to be a promising method of measuring inflammation in IBD patients.展开更多
BACKGROUND Neuroendocrine tumors of appendix(ANETs)known as carcinoids,are rare endocrine neoplasms originated from enterochromaffin cells of gastrointestinal tract.ANETs are the third most frequent(16.7%)gastrointest...BACKGROUND Neuroendocrine tumors of appendix(ANETs)known as carcinoids,are rare endocrine neoplasms originated from enterochromaffin cells of gastrointestinal tract.ANETs are the third most frequent(16.7%)gastrointestinal neuroendocrine tumors,with the incidence of 0.08-0.2 cases/100000 during one year.Incidental ANETs occur in 0.2%-0.7%of emergency surgical resections because of suspected appendicitis which is usually the first manifestation of ANET.Although there are a lot of papers about application of somatostatin receptor scintigraphy in gastrointestinal neuroendocrine tumors,there are very rare sporadic cases described about ANETs particularly.AIM To establish the role of somatostatin receptor scintigraphy(SRS)in the management of patients with neuroendocrine tumors of appendix(ANET).METHODS The total of 35 patients was investigated,23 females and 12 males,average age(43.7±17.3 years).All patients had histological diagnosis of ANET(34 carcinoids of appendix and one tubular carcinoid).Majority of tumors have been found incidentally during surgery of:Acute appendicitis(n=15),perforated appendicitis(n=2),ileus(n=3),hysterectomy(n=3),ruptured ovarian cyst(n=2),caecal volvulus(n=1),while 9 patients had diagnosis of appendiceal tumor before the surgery.Seventeen patients had tumor grade(G)G1,12 G2 and 6 G3.The right hemicolectomy was performed in 13,while the rest of the patients had appendectomy only.SRS was done early(2 h)and late(24 h)after i.v.application of 740 MBq technetium-99 m ethylenediamine-N,N’-diacetic acid Hydrazinonicotinyl-Tyr3-Octreotide(technetium-99 m-Tektrotyd,Polatom,Poland).SRS was performed for restaging in all the patients after surgery.RESULTS There were 12 true positive(TP),19 true negative,3 false positive and 1 false negative SRS result.Sensitivity of the method was 92.31%,specificity was 86.36%,positive predictive value was 80.00%,negative predictive value was 95.00%and accuracy 88.57%.Receiver operating characteristics analysis showed that SRS scintigraphy is a good test for detection TP cases[area under the curve of 0.850,95%confidence interval(CI):0.710-0.990,P<001].Single photon emission computed tomography contributed diagnosis in 7 TP findings.In 10 patients Krenning score was 4 and in 2 was 3.In 8 patients SRS significantly changed the management of the patients(in two surgery was repeated,in 4 somatostatin analogues and in two peptide receptor radionuclide therapy).Median progression-free survival in SRS positive patients was 52 months(95%CI:39.7-117.3 mo)while in SRS negative patients it was 60 months(95%CI:42.8-77.1 mo),without statistically significant difference between the two groups(P=0.434).CONCLUSION In conclusion,our results confirmed the value of SRS in the follow-up of the patients with ANET after surgery,if recurrences or metastases are suspected.展开更多
Objective: To prospectively investigate the value of bone scintigraphy on determining the full extent of tumor involvement in jaw bones and to assess the presence of metastases. Methods: This study had local ethical...Objective: To prospectively investigate the value of bone scintigraphy on determining the full extent of tumor involvement in jaw bones and to assess the presence of metastases. Methods: This study had local ethical committee approval, and all patients gave written informed consent. Thirty seven consecutive patients with primary malignant tumor in jaw bones were recruited for the study. Bone scintigraphy was performed in all patients before surgery to measure the full extent of bony involvement, which was compared with histologic findings. Results: Whole body scan revealed one case with multiple bony metastases. Resection specimens of 36 bone neoplasms were pathologically analyzed to identify type and size of each tumor. The lengths of the tumor involvement in jaw bones defined by bone scintigraphy and pathology were 5.62 ± 1.58 cm, 4.48 ± 1.57 cm, respectively (P 〈 0.05). The tumor negative margins from removed specimens according to bone scintigraphy were pathologically confirmed. With histologic findings as the standard of reference, the accuracy of bone scintigraphy was 100% (36 of 36 patients) in determining the full extent of tumor involvement in jaw bones. Conclusion: Bone scintigraphy tends to offer specific guidelines in determining the appropriate extent of bone resection while entirely clearing the tumor cells and preserving functions whenever possible and in establishing the bony metastases.展开更多
99mTc-galactosyl human serum albumin(GSA) scintigraphy is useful to evaluate hepatic function and hepatic functional reserve. A reliable SPECT and CT integrated system is now commercially available. Using this syste...99mTc-galactosyl human serum albumin(GSA) scintigraphy is useful to evaluate hepatic function and hepatic functional reserve. A reliable SPECT and CT integrated system is now commercially available. Using this system, we can obtain 99mTc-GSA SPECT/CT fused imaging with a small registration error. Therefore, the 99mTc-GSA scintigraphy techniques prove more useful in clinical practice than have been previously reported. In the latest Annals of Surgical Oncology on Oct 2014, the uptake index(UI) values calculated from 99mTc-GSA scintigraphy are reported to be useful for predicting the functional reserve of the future remnant liver. In this paper, we describe the usefulness of 99mTc-GSA scintigraphy as well as some cautions that are necessary as regards using the system.展开更多
Purpose: To evaluate the amalgamation of scintigraphy and sonography techniques in prognosticating renal disease. Methods: All the patients were subjected to renal scintigraphy while 68 patients underwent renal ultras...Purpose: To evaluate the amalgamation of scintigraphy and sonography techniques in prognosticating renal disease. Methods: All the patients were subjected to renal scintigraphy while 68 patients underwent renal ultrasonography. Ninety-six patients’ imaging data was statistically analyzed including 43 females and 53 males. Renal U/S reported anatomical renal anomaly in 94.1% of patients versus 85.4% detected by scintigraphy. There were 41 patients out of 68 diagnosed with hydronephrosis and 21 of them were suffering from mild hydronephrosis as suggested by U/S imaging. The data were statistically analyzed using SPSS 21 software. Results: Renal scintigraphy of 41 hydronephrotic patients validated that 19 patients had non-obstructive bilateral pelvic dilation while the remaining 22 with mild to severe obstruction. Ultrasonography diagnosed 4 patients with renal obstruction. Conversely, renal scintigraphy validated 2 of them with renal obstruction based on renal function. Conclusions: Renal scintigraphy is not significant in diagnosing kidney disease;rather this is a vibrant imaging tool providing supplementary data based on renal function. An effectively targeted intervention regime can be achieved by correlating renal scintigraphy and renal ultrasonography results to minimize renal disease incidence.展开更多
With dual-radiopharmaceutical (DR) parathyroid scintigraphy, imaging with 99mTcO4-or 123I-NaI is combined with 99mTc-sestamibi scintigraphy for localization of parathyroid adenomas. The set images are then either visu...With dual-radiopharmaceutical (DR) parathyroid scintigraphy, imaging with 99mTcO4-or 123I-NaI is combined with 99mTc-sestamibi scintigraphy for localization of parathyroid adenomas. The set images are then either visually compared or digitally subtracted to aid in interpretation. While both EANM and SNMMI guidelines recommend use of digital subtraction over visual interpretation alone, to date, the few formal comparisons performed have not demonstrated superiority. The purpose of this investigation is to rigorously assess the added value of digital subtraction over visual interpretation alone using simultaneously-acquired 123I-NaI and 99mTc-sestamibi images. Materials: 90 consecutive patients with DR parathyroid scintigraphy for primary hyperparathyroidism who underwent successful parathyroidectomy were included. DR planar acquisition was performed 15 minutes post injection using 10% dual energy windows. Digital subtraction was subsequently performed using commercially available software. Images were independently reviewed by 3 nuclear medicine trainees and 2 experienced nuclear medicine physicians with and without digital subtraction. Results were compared with surgical and histopathologic findings, which served as ground truth. Results: 90 patients had a total of 91 confirmed parathyroid lesions. All 5 readers had significantly greater sensitivity with digital subtraction compared with visual interpretation alone while specificity was not significantly diminished. Area under the ROC curve was significantly greater with digital subtraction in 3 of 5 readers. Agreement was greater among trainees and experienced physicians when using digital subtraction. Conclusion: Using an optimized DR planar co-imaging technique, digital subtraction significantly improved inter-observer agreement and confidence of interpretation and increased sensitivity, without diminishing specificity.展开更多
Introduction: Fatigue fractures are secondary to excessive, unusual, repeated mechanical stress, occurring on healthy bone. Bone scintigraphy (BS) with 99mTc-HMDP is an excellent means of diagnosis. We report a case o...Introduction: Fatigue fractures are secondary to excessive, unusual, repeated mechanical stress, occurring on healthy bone. Bone scintigraphy (BS) with 99mTc-HMDP is an excellent means of diagnosis. We report a case of stress fracture of the calcaneus with scintigraphic diagnosis, in a marathon runner. Patient and Methods: He is a 40-year-old athlete in overtraining with right calcaneal pain on running, intense at first, moderate in the middle and then persistent after exercise. The interrogation found no trauma to the right foot and the x-ray of the foot was without abnormality. The so 3 phases were performed following an injection of 564 MBq of 99mTc-HMDP, with a SPECT gamma camera. Results: Bone scintigraphy found in the early phase, hyper-perfusion and hyper-fixation of the right calcaneal region compared to its left counterpart and in the bone phase persistence of focal hyperfixation opposite the right calcaneus. This scintigraphic aspect of the right calcaneus in an overtrained marathon runner, in a painful context and in front of a normal X-ray, made us evoke a fracture of fatigue. A complementary CT scan performed two days after the BS was without abnormality. Conclusion: Fatigue fractures are micro-fractures generally not noticed on radiography and CT. BS due to its high sensitivity is an excellent or the best tool for the early diagnosis of stress fractures.展开更多
Gastro-esophageal scintigraphy (milk scan) is an accurate technique for detecting gastro-esophageal reflux that can be performed rapidly with minimal patient discomfort. A retrospective study was performed to find out...Gastro-esophageal scintigraphy (milk scan) is an accurate technique for detecting gastro-esophageal reflux that can be performed rapidly with minimal patient discomfort. A retrospective study was performed to find out to how much radionuclide milk scan is sensitive for detecting gastro-esophageal reflux (GER) for 89 patients who subjected to milk scan within Years 2010 to 2013. The study group age is ranging from one month old to four years old. Milk scan was performed using PHILIPS and SEIMENS machine. Tc 99-m sulfur colloid with milk administrated orally or through nasogastric tube to the patient. The highest frequency for milk scan study was in age group of 0 - 6 months old with 77% positive finding. Patients who suffer repeated vomiting represented the highest reason of examination for milk scan (46% of overall cases), while chocking attacks, pulmonary aspiration, and congenital heart disease, were 26%, 16%, 12% respectively of the overall cases. Seventy-nine percent of patients who prepared to be examine using nasogastric tube found with positive finding, 50% of GER patients have abnormal tracer activity in the mid of esophagus;on the other hand, 50% of GER patients divided equally between the lower and upper esophagus. The study show that infants especially in age of 0 - 6 months old and with repeated vomiting symptoms are strongly recommended to milk scan study rather than fluoroscopy to avoid unnecessary dose to the patients.展开更多
The scintiphotos and ultrasonophotos of 186 patients with focal and diffuse diseases of liver were collected and analysed. All the data were get from the in-patients of China-Japan Friendship Hospital. The Sigma 438 t...The scintiphotos and ultrasonophotos of 186 patients with focal and diffuse diseases of liver were collected and analysed. All the data were get from the in-patients of China-Japan Friendship Hospital. The Sigma 438 typedγ camera (USA) was used. Fifteen min after 99mTc-phytate were injected i.v., If any defect region was found, it was recorded as a SOL; the SSA 90A, SAL 77A and SAL 50A US scanners (Japan) were used, if any abnormal echo pattern was found, it was a SOL. Of 134 patients have done both examinations during 7 days, 122 patients had coincident results occupied 91.0%. For detection of SOL, the sensitivity of scintigraphy is 94.1%, specificity is 94.2%, accuracy is 94.8%; the sensitivity of US is 100%, specificity is 89.7%, the accuracy is 95.6%. The hepatic blood flow and blood pool study showed that 104 from 115 patients were coincident (90.4%). The spleen and liver accumulation ratio determination showed that 51 from 64 subjects were coincident (80.0%). The characteristic features of scintigraphy and US graphy were described in hepatoma, hemangioma, cyst abscess and cirrhosis. The advantages of these examinations were discussed and concluded that their procedures are valuable and widely available.展开更多
AIM: To assess the inter-observer agreement and reliability as well as intra-observer repeatability for lacrimal scintigraphy(LS) reports with and without considering the irrigation test results.METHODS: A prospective...AIM: To assess the inter-observer agreement and reliability as well as intra-observer repeatability for lacrimal scintigraphy(LS) reports with and without considering the irrigation test results.METHODS: A prospective, observational, cross sectional study. Two masked clinicians(lacrimal surgeon and nuclear medicine specialist) independently reported 100 LS images(50 patients of >6 years of age with unilateral anophthalmic socket) in a university hospital. The lacrimal surgeon performed a diagnostic irrigation test and repeated the report of the same LS images 2 y after the first report(intra-observer agreement). A weighted Kappa analysis was performed to determine inter-observer agreement and reliability as well as intra-observer repeatability for the type(normal, partial and complete obstruction) and location(presac, preduct, and intraduct) of the obstruction. Subgroup analysis was also performed with consideration of irrigation test results. RESULTS: A significantly moderate agreement was found between lacrimal surgeon and nuclear medicine specialist for both the type(Kappa=0.55) and location(Kappa=0.48) of obstruction. Agreement values were higher for the type(Kappa=0.61 vs 0.41) and location(Kappa=0.56 vs 0.31) of obstruction in cases with normal than abnormal irrigation test. Strong and significant intraobserver(lacrimal surgeon) repeatability was found for both the type(Kappa=0.66) and location(Kappa=0.69) of obstruction. LS showed no to slight reliability based on irrigation test.CONCLUSION: A moderate agreement is found between lacrimal surgeon and nuclear medicine specialist regarding the interpretation of LS suggesting the importance ofconsensus groups among nuclear medicine specialists and lacrimal surgeons to create a common language for interpretation of LS. Intra-observer repeatability is strong for the lacrimal surgeon.展开更多
BACKGROUND Primary hepatic neuroendocrine neoplasm(NEN)is a rare condition,and it is difficult to differentiate between primary and metastatic hepatic NENs.Herein,we report a case of primary hepatic NEN that initially...BACKGROUND Primary hepatic neuroendocrine neoplasm(NEN)is a rare condition,and it is difficult to differentiate between primary and metastatic hepatic NENs.Herein,we report a case of primary hepatic NEN that initially mimicked a hemangioma but showed a gradual increase in size on long-term careful observation.CASE SUMMARY A 47-year-old woman was incidentally diagnosed with a 12-mm liver mass,suspected to be a hemangioma.Since then,regular follow-up had been carried out.Ten years later,she was referred to our institute due to the tumor(located in segment 4)having increased to 20 mm.Several imaging studies depicted no apparent extrahepatic lesion.Positron emission tomography(PET)/computed tomography exhibited significant accumulation in the mass lesion,which made us consider the possibility of malignancy.Left hepatectomy was performed.The histopathological diagnosis was neuroendocrine tumor grade 2,with somatostatin receptor 2 a/5 positivity.Postoperative somatostatin receptor scintigraphy(SRS)showed no other site,leading to the diagnosis of NEN of primary hepatic origin.The gradual growth of the hepatic NEN over 10 years suggested that it was likely to be a primary liver tumor.CONCLUSION In this case,positivity on PET and postoperative SRS may have helped determine whether the tumor was primary or metastatic.展开更多
Nuclide renal dynamic imaging was performed on 88 transplanted kidney. Two kinds of renal scintigraphic characteristics were identified in recipients with supravesical obstruction of the graft. First, the regular typ...Nuclide renal dynamic imaging was performed on 88 transplanted kidney. Two kinds of renal scintigraphic characteristics were identified in recipients with supravesical obstruction of the graft. First, the regular type was characterized by radioactivity defect area in kidney parenchyma during early uptake period followed by ureteropelvic retention. Second, the tubular type was typified by cortical retention and attenuation in collecting system during the whole test period with a special sign of “hollow kidney”. Non obstructive dilated calyces showed similar signs as the regular type. Acute rejection reaction and tubule necrosis demonstrated obstructive time activity curves. However, the radioactivity retention appeared in cortex. It was suggested that dilated calyces and obstructive renogram might not be reliable evidence for upper urinary tract obstruction. The signs of radioactivity attenuation in kidney parenchyma during early uptake period followed by ureteropelvic retention may be more valuable for the evaluation. As for tubular obstruction, specified “hollow kidney” was the characteristic sign which is helpful for the diagnosis.展开更多
基金Supported by Grants from the National Natural Science Foundation of China,No.81061120521and No.81270470Shanghai Science and Technology Commission,No.12XD1404000
文摘AIM:To assess the diagnostic value of a combination of intragastric bile acids and hepatobiliary scintigraphy in the detection of duodenogastric reflux(DGR).METHODS:The study contained 99 patients with DGR and 70 healthy volunteers who made up the control group.The diagnosis was based on the combination of several objective arguments:a long history of gastric symptoms(i.e.,nausea,epigastric pain,and/or bilious vomiting) poorly responsive to medical treatment,gastroesophageal reflux symptoms unresponsive to protonpump inhibitors,gastritis on upper gastrointestinal(GI) endoscopy and/or at histology,presence of a bilious gastric lake at > 1 upper GI endoscopy,pathologic 24-h intragastric bile monitoring with the Bilitec device.Gas-tric juice was aspirated in the GI endoscopy and total bile acid(TBA),total bilirubin(TBIL) and direct bilirubin(DBIL) were tested in the clinical laboratory.Continuous data of gastric juice were compared between each group using the independent-samples Mann-Whitney U-test and their relationship was analysed by Spearman's rank correlation test and Fisher's linear discriminant analysis.Histopathology of DGR patients and 23 patients with chronic atrophic gastritis was compared by clinical pathologists.Using the Independent-samples Mann-Whitney U-test,DGR index(DGRi) was calculated in 28 patients of DGR group and 19 persons of control group who were subjected to hepatobiliary scintigraphy.Receiver operating characteristic curve was made to determine the sensitivity and specificity of these two methods in the diagnosis of DGR.RESULTS:The group of patients with DGR showed a statistically higher prevalence of epigastric pain in comparison with control group.There was no significant difference between the histology of gastric mucosa with atrophic gastritis and duodenogastric reflux.The bile acid levels of DGR patients were significantly higher than the control values(Z:TBA:-8.916,DBIL:-3.914,TBIL:-6.197,all P < 0.001).Two of three in the DGR group have a significantly associated with each other(r:TBA/DBIL:0.362,TBA/TBIL:0.470,DBIL/TBIL:0.737,all P < 0.001).The Fisher's discriminant function is followed:Con:Y = 0.002TBA + 0.048DBIL + 0.032TBIL 0.986;Reflux:Y = 0.012TBA + 0.076DBIL + 0.089TBIL-2.614.Eighty-four point zero five percent of original grouped cases were correctly classified by this method.With respect to the DGR group,DGRi were higher than those in the control group with statistically significant differences(Z =-5.224,P < 0.001).Twenty eight patients(59.6%) were deemed to be duodenogastric reflux positive by endoscopy,as compared to 37 patients(78.7%) by hepatobiliary scintigraphy.CONCLUSION:The integrated use of intragastric bile acid examination and scintigraphy can greatly improve the sensitivity and specificity of the diagnosis of DGR.
基金Supported by The IN-Sung Foundation for Medical Research and Samsung Biomedical Research Institute, Grant No. SBRIC-B1-118-1
文摘AIM:To investigate the diagnostic accuracy of hepatobiliary scintigraphy(HBS) in detecting biliary strictures in living donor liver transplantation(LDLT) patients.METHODS:We retrospectively reviewed 104 adult LDLT recipients of the right hepatic lobe with duct-toduct anastomosis,who underwent HBS and cholangiography.The HBS results were categorized as normal,parenchymal dysfunction,biliary obstruction,or bile leakage without re-interpretation.The presence of biliary strictures was determined by percutaneous cholangiography or endoscopic retrograde cholangiopancreatography(ERCP).RESULTS:In 89 patients with biliary strictures,HBS showed biliary obstruction in 50 and no obstruction in 39,for a sensitivity of 56.2%.Of 15 patients with no biliary strictures,HBS showed no obstruction in 11,for a specificity of 73.3%.The positive predictive value(PPV) was 92.6%(50/54) and the negative predictive value(NPV) was 22%(11/50).We also analyzed the diagnostic accuracy of the change in bile duct size.The sensitivity,NPV,specificity,and PPV were 65.2%,27.9%,80% and 95%,respectively.CONCLUSION:The absence of biliary obstruction on HBS is not reliable.Thus,when post-LDLT biliary strictures are suspected,early ERCP may be considered.
文摘Noninvasive diagnoses of nonalcoholic fatty-liver disease(NAFLD) involve the use of serologic markers and imaging methods, such as conventional ultrasonography(US),computed tomography, and magnetic resonance imaging. Although these methods are reliable for the noninvasive detection of moderate to severe fatty changes in the liver, they are not reliable for detecting nonalcoholic steatohepatitis(NASH) and fibrosis. New imaging technologies, such as US-based transient elastography, acoustic radiation force impulse and magnetic resonancebased elastography, can reportedly be used to determine the severity of liver fibrosis associated with NASH. In this context, the field of nuclear medicine through liver scintigraphy has recently been proposed, and is being explored for use in the diagnosis of NASH. More importantly, nuclear medicine may contribute to the distinction between simple steatosis and NASH. For example, the enhanced release of cytokines and the decrease in the phagocytic activity of Kupffer cells play important roles in the pathogenesis of NASH. Removal of technetium-99 m colloid from circulation by Kupffer cell phagocytosis therefore provides a valuable imaging technique. Thus, nuclear medicine is poised to provide useful tools for the evaluation of patients with NAFLD. However, the evidence is still scarce, and more studies with larger samples are needed to identify their role before they are used in clinical practice.
文摘In order to investigate the clinical significance of 99mTc-Tetrofosmin (TF) scintigraphy in the evaluation of lung cancer and mediastinal lymphoid node involvement, 33 patients with pulmo- nary neoplasmas were subjected to both 99mTc-TF scintigraphies and CT scans in one week before their operations or puncturations. All the images were judged visually and the emission images were analyzed with semi-quantitative methods in addition. The results of each group were compared. There was marked difference in target/non-target (T/N) ratio between the lung cancer group and the benign lesion group (P〈0.001). Moreover, in the lung cancer group, T/N ratio in tomographies was signifi- cantly higher than that in planar images (P〈0.01). The sensitivity and accuracy of semi-quantitative analysis in 99mTc-TF SPECT were significantly higher than those of CT in the diagnosis of pulmonary neoplasmas (P〈0.05 and P〈0.01 respectively), so was the sensitivity of 99mTc-TF SPECT vs CT in the diagnosis of mediastinal lymphoid node metastasis (P〈0.05). It was also found that epidermoid squamous cell carcinomas and adenocarcinomas had a higher T/N ratio than in small cell carcinomas (P〈0.05), and 2 h washout rate (WR) of adenocarcinomas was higher than that of epidermoid squamous cell carcinomas (P〈0.05). In conclusion, 99mTc-TF scintigraphy showed a favorable diag- nostic accuracy in appraising lung cancers and mediastinal lymph node metastases. Furthermore semi-quantitative technology can improve the accuracy, and is potential to offer some information about histological type of the cancer tissue. Therefore, 99mTc-TF scintigraphy will be a useful tool in the diagnosis and staging of lung cancer.
文摘AIM: To evaluate the role of pentavalent Tc-99m dimercaptosuccinic acid [Tc-99m (V) DMSA] in the diagnosis of ischemic colitis. METHODS: Fourteen patients with endoscopically and histologically confirmed ischemic colitis were included in the study. Tc-99m (V) DMSA scintigraphy was performed within 2 d after colonoscopy. Images were considered positive when an area of increased activity was observed in the region of interest and negative when no abnormal tracer uptake was detected. RESULTS: In 3 out of the 14 patients, Tc-99m (V) DMSA images showed moderate activity in the bowel. The scintigraphic results corresponded with the endoscopic findings. In the other 11 patients, no abnormal tracer uptake was detected in the abdomen. CONCLUSION: Besides the limited number of patients, Tc-99m (V) DMSA could not be considered as a useful imaging modality for the evaluation of ischemic colitis.
文摘AIM: To determine the role of scintigraphy in patients with gastrointestinal (GI) bleeding of unknown Iocalisation. METHODS: We performed retrospective analyses on 92 patients receiving scintigraphies from 1993 to 2000 in the University of Regensburg hospital, which were done for Iocalisation of GI bleeding as a diagnostic step after an unsuccessful endoscopy. In addition to the scintigraphies, further diagnostic steps such as endoscopy, angiography or operations were performed. In some of the scintigraphies with negative results, a provocation test for bleeding with heparinisation was carried out. RESULTS: 73% of all scintigraphies showed a positive result. In 4.5% of the positive results, the source was located in the stomach, in 37% the source was the small bowel, in 25% the source was the right colon, in 4.5% the source was the left colon, and in 20% no clear Iocalisation was possible. Only 4% of all scintigraphies were false positive. A reliable positive scintigraphy was independent of the age of the examined patient. A provocation test for bleeding with heparin resulted in an additional 46% of positive scintigraphies with a reliable Iocalisation in primary negative scintigraphies. CONCLUSION- Our results show that scintigraphy and scintigraphy with heparin provocation tests are reliable procedures. They enable a reliable Iocalisation in about half of the obscure GI-bleeding cases. Scintigraphy is superior to angiography in locating a bleeding. It is shown that even in the age of video capsule endoscopy and double-balloon enteroscopy, scintigraphy provides a reliable and directed localization of GI bleeding and offers carefully targeted guidance for other procedures.
基金Supported by the Scientific and Technological Research Council of Turkey,No.106S191-SBAG-3439
文摘AIM To evaluate the agreement of multichannel intraluminal impedance-p H monitoring(MII-p HM) and gastroesophageal reflux scintigraphy(GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspectedgastroesophageal reflux disease(GERD) underwent 24-h combined MII-p HM recording and one hour radionuclide scintigraphy during the course of the MIIpH M study. Catheters with 6 impedance channels and 1 p H sensor were placed transnasally. Impedance and p H data analysis were performed automatically and manually. For impedance monitoring, reflux was defined as a retrograde 50% drop in impedance, starting distally and propagating retrogradely to at least the next two more proximal measuring channels. Reflux index(RI, percentage of the entire record that esophageal p H is < 4.0) greater than 4.2% for p HM and number of refluxes more than 50 for 24 h for MII were accepted as positive test results. At scintigraphy, 240 frames of 15 seconds duration were acquired in the supine position. Gastroesophageal reflux was defined as at least one reflux episode in the esophagus. After scintigraphic evaluation, impedance-pH recordings and scintigraphic images were evaluated together and agreement between tests were evaluated with Cohen's kappa.RESULTS Sufficient data was obtained from 60(80%) patients(34 male, 56.7%) with a mean age of 8.7 ± 3.7 years(range: 2.5-17.3 years; median: 8.5 years). Chronic cough, nausea, regurgitation and vomiting were the most frequent symptoms. The mean time for recording of MII-pH M was 22.8 ± 2.4 h(range: 16-30 h; median: 22.7 h). At least one test was positive in 57(95%) patients. According to diagnostic criteria, GERD was diagnosed in 34(57.7%), 44(73.3%), 47(78.3%) and 51(85%) patients by means of p HM, MII, GES and MII-p HM, respectively. The observed percentage agreements/κ values for GES and p HM, GES and MII, GES and MII-p HM, and MII and p HM are 48.3%/-0.118; 61.7%/-0.042; 73.3%/0.116 and 60%/0.147, respectively. There was no or slight agreement between GES and p HM alone, MII alone or MII-p HM. p H monitoring alone missed 17 patients compared to combined MII-p HM. The addition of MII to pH monitoring increased the diagnosis rate by 50%.CONCLUSION No or slight agreement was found among p H monitoring, MII monitoring, MII-pH monitoring and GES for the diagnosis of gastroesophageal reflux disease.
基金Supported by the Gastroenterological Association of Thailand
文摘AIM: To investigate potential roles of per rectal portal scintigraphy in diagnosis of esophageal varices and predicting the risk of bleeding.METHODS: Fifteen normal subjects and fifty cirrhotic patients with endoscopically confirmed esophageal varices were included. Patients were categorized into bleeder and non-bleeder groups according to history of variceal bleeding. All had completed per rectal portal scintigraphy using 99mTechnetium pertechnetate. The shunt index was calculated from the ratio of 99mTechnetium pertechnetate in the heart and the liver. Data were analyzed using Student’s t-test and receiver operating characteristics.RESULTS: Cirrhotic patients showed a higher shunt index than normal subjects (63.80 ± 25.21 vs 13.54 ± 6.46, P < 0.01). Patients with variceal bleeding showed a higher shunt index than those without bleeding (78.45 ± 9.40 vs 49.35 ± 27.72, P < 0.01). A shunt index of over 20% indicated the presence of varices and that of over 60% indicated the risk of variceal bleeding.CONCLUSION: In cirrhotic patients, per rectal portal scintigraphy is a clinically useful test for identifying esophageal varices and risk of variceal bleeding.
文摘The diagnosis of inflammatory bowel disease(IBD) depends on direct endoscopic visualization of the colonic and ileal mucosa and the histological study of the obtained samples.Radiological and scintigraphic methods are mainly used as an adjunct to endoscopy.In this review,we focus on the diagnostic potential of nuclear medicine procedures.The value of all radiotracers is described with special reference to those with greater experience and more satisfactory results.Tc-99m hexamethylpropylene amine oxime white blood cells remain a widely acceptable scintigraphic method for the diagnosis of IBD,as well as for the evaluation of disease extension and severity.Recently,pentavalent Tc-99m dimercaptosuccinic acid has been recommended as an accurate variant and a complementary technique to endoscopy for the follow-up and assessment of disease activity.Positron emission tomography alone or with computed tomography using fluorine-18 fluorodeoxyglucose appears to be a promising method of measuring inflammation in IBD patients.
基金Ministry of Science,Education and Technology Republic of Serbia,No. 175018。
文摘BACKGROUND Neuroendocrine tumors of appendix(ANETs)known as carcinoids,are rare endocrine neoplasms originated from enterochromaffin cells of gastrointestinal tract.ANETs are the third most frequent(16.7%)gastrointestinal neuroendocrine tumors,with the incidence of 0.08-0.2 cases/100000 during one year.Incidental ANETs occur in 0.2%-0.7%of emergency surgical resections because of suspected appendicitis which is usually the first manifestation of ANET.Although there are a lot of papers about application of somatostatin receptor scintigraphy in gastrointestinal neuroendocrine tumors,there are very rare sporadic cases described about ANETs particularly.AIM To establish the role of somatostatin receptor scintigraphy(SRS)in the management of patients with neuroendocrine tumors of appendix(ANET).METHODS The total of 35 patients was investigated,23 females and 12 males,average age(43.7±17.3 years).All patients had histological diagnosis of ANET(34 carcinoids of appendix and one tubular carcinoid).Majority of tumors have been found incidentally during surgery of:Acute appendicitis(n=15),perforated appendicitis(n=2),ileus(n=3),hysterectomy(n=3),ruptured ovarian cyst(n=2),caecal volvulus(n=1),while 9 patients had diagnosis of appendiceal tumor before the surgery.Seventeen patients had tumor grade(G)G1,12 G2 and 6 G3.The right hemicolectomy was performed in 13,while the rest of the patients had appendectomy only.SRS was done early(2 h)and late(24 h)after i.v.application of 740 MBq technetium-99 m ethylenediamine-N,N’-diacetic acid Hydrazinonicotinyl-Tyr3-Octreotide(technetium-99 m-Tektrotyd,Polatom,Poland).SRS was performed for restaging in all the patients after surgery.RESULTS There were 12 true positive(TP),19 true negative,3 false positive and 1 false negative SRS result.Sensitivity of the method was 92.31%,specificity was 86.36%,positive predictive value was 80.00%,negative predictive value was 95.00%and accuracy 88.57%.Receiver operating characteristics analysis showed that SRS scintigraphy is a good test for detection TP cases[area under the curve of 0.850,95%confidence interval(CI):0.710-0.990,P<001].Single photon emission computed tomography contributed diagnosis in 7 TP findings.In 10 patients Krenning score was 4 and in 2 was 3.In 8 patients SRS significantly changed the management of the patients(in two surgery was repeated,in 4 somatostatin analogues and in two peptide receptor radionuclide therapy).Median progression-free survival in SRS positive patients was 52 months(95%CI:39.7-117.3 mo)while in SRS negative patients it was 60 months(95%CI:42.8-77.1 mo),without statistically significant difference between the two groups(P=0.434).CONCLUSION In conclusion,our results confirmed the value of SRS in the follow-up of the patients with ANET after surgery,if recurrences or metastases are suspected.
文摘Objective: To prospectively investigate the value of bone scintigraphy on determining the full extent of tumor involvement in jaw bones and to assess the presence of metastases. Methods: This study had local ethical committee approval, and all patients gave written informed consent. Thirty seven consecutive patients with primary malignant tumor in jaw bones were recruited for the study. Bone scintigraphy was performed in all patients before surgery to measure the full extent of bony involvement, which was compared with histologic findings. Results: Whole body scan revealed one case with multiple bony metastases. Resection specimens of 36 bone neoplasms were pathologically analyzed to identify type and size of each tumor. The lengths of the tumor involvement in jaw bones defined by bone scintigraphy and pathology were 5.62 ± 1.58 cm, 4.48 ± 1.57 cm, respectively (P 〈 0.05). The tumor negative margins from removed specimens according to bone scintigraphy were pathologically confirmed. With histologic findings as the standard of reference, the accuracy of bone scintigraphy was 100% (36 of 36 patients) in determining the full extent of tumor involvement in jaw bones. Conclusion: Bone scintigraphy tends to offer specific guidelines in determining the appropriate extent of bone resection while entirely clearing the tumor cells and preserving functions whenever possible and in establishing the bony metastases.
文摘99mTc-galactosyl human serum albumin(GSA) scintigraphy is useful to evaluate hepatic function and hepatic functional reserve. A reliable SPECT and CT integrated system is now commercially available. Using this system, we can obtain 99mTc-GSA SPECT/CT fused imaging with a small registration error. Therefore, the 99mTc-GSA scintigraphy techniques prove more useful in clinical practice than have been previously reported. In the latest Annals of Surgical Oncology on Oct 2014, the uptake index(UI) values calculated from 99mTc-GSA scintigraphy are reported to be useful for predicting the functional reserve of the future remnant liver. In this paper, we describe the usefulness of 99mTc-GSA scintigraphy as well as some cautions that are necessary as regards using the system.
文摘Purpose: To evaluate the amalgamation of scintigraphy and sonography techniques in prognosticating renal disease. Methods: All the patients were subjected to renal scintigraphy while 68 patients underwent renal ultrasonography. Ninety-six patients’ imaging data was statistically analyzed including 43 females and 53 males. Renal U/S reported anatomical renal anomaly in 94.1% of patients versus 85.4% detected by scintigraphy. There were 41 patients out of 68 diagnosed with hydronephrosis and 21 of them were suffering from mild hydronephrosis as suggested by U/S imaging. The data were statistically analyzed using SPSS 21 software. Results: Renal scintigraphy of 41 hydronephrotic patients validated that 19 patients had non-obstructive bilateral pelvic dilation while the remaining 22 with mild to severe obstruction. Ultrasonography diagnosed 4 patients with renal obstruction. Conversely, renal scintigraphy validated 2 of them with renal obstruction based on renal function. Conclusions: Renal scintigraphy is not significant in diagnosing kidney disease;rather this is a vibrant imaging tool providing supplementary data based on renal function. An effectively targeted intervention regime can be achieved by correlating renal scintigraphy and renal ultrasonography results to minimize renal disease incidence.
文摘With dual-radiopharmaceutical (DR) parathyroid scintigraphy, imaging with 99mTcO4-or 123I-NaI is combined with 99mTc-sestamibi scintigraphy for localization of parathyroid adenomas. The set images are then either visually compared or digitally subtracted to aid in interpretation. While both EANM and SNMMI guidelines recommend use of digital subtraction over visual interpretation alone, to date, the few formal comparisons performed have not demonstrated superiority. The purpose of this investigation is to rigorously assess the added value of digital subtraction over visual interpretation alone using simultaneously-acquired 123I-NaI and 99mTc-sestamibi images. Materials: 90 consecutive patients with DR parathyroid scintigraphy for primary hyperparathyroidism who underwent successful parathyroidectomy were included. DR planar acquisition was performed 15 minutes post injection using 10% dual energy windows. Digital subtraction was subsequently performed using commercially available software. Images were independently reviewed by 3 nuclear medicine trainees and 2 experienced nuclear medicine physicians with and without digital subtraction. Results were compared with surgical and histopathologic findings, which served as ground truth. Results: 90 patients had a total of 91 confirmed parathyroid lesions. All 5 readers had significantly greater sensitivity with digital subtraction compared with visual interpretation alone while specificity was not significantly diminished. Area under the ROC curve was significantly greater with digital subtraction in 3 of 5 readers. Agreement was greater among trainees and experienced physicians when using digital subtraction. Conclusion: Using an optimized DR planar co-imaging technique, digital subtraction significantly improved inter-observer agreement and confidence of interpretation and increased sensitivity, without diminishing specificity.
文摘Introduction: Fatigue fractures are secondary to excessive, unusual, repeated mechanical stress, occurring on healthy bone. Bone scintigraphy (BS) with 99mTc-HMDP is an excellent means of diagnosis. We report a case of stress fracture of the calcaneus with scintigraphic diagnosis, in a marathon runner. Patient and Methods: He is a 40-year-old athlete in overtraining with right calcaneal pain on running, intense at first, moderate in the middle and then persistent after exercise. The interrogation found no trauma to the right foot and the x-ray of the foot was without abnormality. The so 3 phases were performed following an injection of 564 MBq of 99mTc-HMDP, with a SPECT gamma camera. Results: Bone scintigraphy found in the early phase, hyper-perfusion and hyper-fixation of the right calcaneal region compared to its left counterpart and in the bone phase persistence of focal hyperfixation opposite the right calcaneus. This scintigraphic aspect of the right calcaneus in an overtrained marathon runner, in a painful context and in front of a normal X-ray, made us evoke a fracture of fatigue. A complementary CT scan performed two days after the BS was without abnormality. Conclusion: Fatigue fractures are micro-fractures generally not noticed on radiography and CT. BS due to its high sensitivity is an excellent or the best tool for the early diagnosis of stress fractures.
文摘Gastro-esophageal scintigraphy (milk scan) is an accurate technique for detecting gastro-esophageal reflux that can be performed rapidly with minimal patient discomfort. A retrospective study was performed to find out to how much radionuclide milk scan is sensitive for detecting gastro-esophageal reflux (GER) for 89 patients who subjected to milk scan within Years 2010 to 2013. The study group age is ranging from one month old to four years old. Milk scan was performed using PHILIPS and SEIMENS machine. Tc 99-m sulfur colloid with milk administrated orally or through nasogastric tube to the patient. The highest frequency for milk scan study was in age group of 0 - 6 months old with 77% positive finding. Patients who suffer repeated vomiting represented the highest reason of examination for milk scan (46% of overall cases), while chocking attacks, pulmonary aspiration, and congenital heart disease, were 26%, 16%, 12% respectively of the overall cases. Seventy-nine percent of patients who prepared to be examine using nasogastric tube found with positive finding, 50% of GER patients have abnormal tracer activity in the mid of esophagus;on the other hand, 50% of GER patients divided equally between the lower and upper esophagus. The study show that infants especially in age of 0 - 6 months old and with repeated vomiting symptoms are strongly recommended to milk scan study rather than fluoroscopy to avoid unnecessary dose to the patients.
基金The Project was supported by the International Atomic Energy Agency
文摘The scintiphotos and ultrasonophotos of 186 patients with focal and diffuse diseases of liver were collected and analysed. All the data were get from the in-patients of China-Japan Friendship Hospital. The Sigma 438 typedγ camera (USA) was used. Fifteen min after 99mTc-phytate were injected i.v., If any defect region was found, it was recorded as a SOL; the SSA 90A, SAL 77A and SAL 50A US scanners (Japan) were used, if any abnormal echo pattern was found, it was a SOL. Of 134 patients have done both examinations during 7 days, 122 patients had coincident results occupied 91.0%. For detection of SOL, the sensitivity of scintigraphy is 94.1%, specificity is 94.2%, accuracy is 94.8%; the sensitivity of US is 100%, specificity is 89.7%, the accuracy is 95.6%. The hepatic blood flow and blood pool study showed that 104 from 115 patients were coincident (90.4%). The spleen and liver accumulation ratio determination showed that 51 from 64 subjects were coincident (80.0%). The characteristic features of scintigraphy and US graphy were described in hepatoma, hemangioma, cyst abscess and cirrhosis. The advantages of these examinations were discussed and concluded that their procedures are valuable and widely available.
文摘AIM: To assess the inter-observer agreement and reliability as well as intra-observer repeatability for lacrimal scintigraphy(LS) reports with and without considering the irrigation test results.METHODS: A prospective, observational, cross sectional study. Two masked clinicians(lacrimal surgeon and nuclear medicine specialist) independently reported 100 LS images(50 patients of >6 years of age with unilateral anophthalmic socket) in a university hospital. The lacrimal surgeon performed a diagnostic irrigation test and repeated the report of the same LS images 2 y after the first report(intra-observer agreement). A weighted Kappa analysis was performed to determine inter-observer agreement and reliability as well as intra-observer repeatability for the type(normal, partial and complete obstruction) and location(presac, preduct, and intraduct) of the obstruction. Subgroup analysis was also performed with consideration of irrigation test results. RESULTS: A significantly moderate agreement was found between lacrimal surgeon and nuclear medicine specialist for both the type(Kappa=0.55) and location(Kappa=0.48) of obstruction. Agreement values were higher for the type(Kappa=0.61 vs 0.41) and location(Kappa=0.56 vs 0.31) of obstruction in cases with normal than abnormal irrigation test. Strong and significant intraobserver(lacrimal surgeon) repeatability was found for both the type(Kappa=0.66) and location(Kappa=0.69) of obstruction. LS showed no to slight reliability based on irrigation test.CONCLUSION: A moderate agreement is found between lacrimal surgeon and nuclear medicine specialist regarding the interpretation of LS suggesting the importance ofconsensus groups among nuclear medicine specialists and lacrimal surgeons to create a common language for interpretation of LS. Intra-observer repeatability is strong for the lacrimal surgeon.
文摘BACKGROUND Primary hepatic neuroendocrine neoplasm(NEN)is a rare condition,and it is difficult to differentiate between primary and metastatic hepatic NENs.Herein,we report a case of primary hepatic NEN that initially mimicked a hemangioma but showed a gradual increase in size on long-term careful observation.CASE SUMMARY A 47-year-old woman was incidentally diagnosed with a 12-mm liver mass,suspected to be a hemangioma.Since then,regular follow-up had been carried out.Ten years later,she was referred to our institute due to the tumor(located in segment 4)having increased to 20 mm.Several imaging studies depicted no apparent extrahepatic lesion.Positron emission tomography(PET)/computed tomography exhibited significant accumulation in the mass lesion,which made us consider the possibility of malignancy.Left hepatectomy was performed.The histopathological diagnosis was neuroendocrine tumor grade 2,with somatostatin receptor 2 a/5 positivity.Postoperative somatostatin receptor scintigraphy(SRS)showed no other site,leading to the diagnosis of NEN of primary hepatic origin.The gradual growth of the hepatic NEN over 10 years suggested that it was likely to be a primary liver tumor.CONCLUSION In this case,positivity on PET and postoperative SRS may have helped determine whether the tumor was primary or metastatic.
文摘Nuclide renal dynamic imaging was performed on 88 transplanted kidney. Two kinds of renal scintigraphic characteristics were identified in recipients with supravesical obstruction of the graft. First, the regular type was characterized by radioactivity defect area in kidney parenchyma during early uptake period followed by ureteropelvic retention. Second, the tubular type was typified by cortical retention and attenuation in collecting system during the whole test period with a special sign of “hollow kidney”. Non obstructive dilated calyces showed similar signs as the regular type. Acute rejection reaction and tubule necrosis demonstrated obstructive time activity curves. However, the radioactivity retention appeared in cortex. It was suggested that dilated calyces and obstructive renogram might not be reliable evidence for upper urinary tract obstruction. The signs of radioactivity attenuation in kidney parenchyma during early uptake period followed by ureteropelvic retention may be more valuable for the evaluation. As for tubular obstruction, specified “hollow kidney” was the characteristic sign which is helpful for the diagnosis.