期刊文献+
共找到5,364篇文章
< 1 2 250 >
每页显示 20 50 100
Instantaneous desulfurization of molten steel with varied aluminum and silicon by CaO-Al_(2)O_(3) particles:In situ observation using confocal scanning laser microscopy
1
作者 Chunjie She Hejun Zhang +2 位作者 Yanhui Zhang Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2026年第2期545-554,共10页
Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfur... Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfurization were analyzed.When the total aluminum content in the steel increased from 6 to 1100 ppm,the CaS content in CaO–Al_(2)O_(3) particles increased from 2.1wt%to 84.84wt%after the reaction for 90 s.Furthermore,when the silicon content in the steel increased from 0.01wt%to 2.20wt%,the CaS content in CaO–Al_(2)O_(3) particles increased from 1.53wt%to 79.01wt%after the reaction for 90 s.This indicates that the increase in the aluminum and silicon contents of the steel promoted the desulfurization of CaO–Al_(2)O_(3) particles.A kinetic model was established to predict the CaO–Al_(2)O_(3) particles composition,and the diffusion coefficient of sulfur in CaO–Al_(2)O_(3) particles was 9.375×10^(−10)m^(2)·s^(−1) at 1600℃,which provided a new method for the calculation of diffusion coefficient. 展开更多
关键词 DESULFURIZATION high-temperature confocal scanning laser microscopy steel DESULFURIZER kinetic model ALUMINUM SILICON
在线阅读 下载PDF
In-situ observation of nonmetallic inclusions in steel using confocal scanning laser microscopy:A review 被引量:4
2
作者 Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2025年第5期975-991,共17页
The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are revi... The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are reviewed and summarized,particularly the col-lision of various inclusions,dissolution of inclusions in liquid slag,and reactions between inclusions and steel.Solid inclusions exhibited a high collision tendency,whereas pure liquid inclusions exhibited minimal collisions because of the small attraction force induced by their<90°contact angle with molten steel.The collision of complex inclusions in molten steel was not included in the scope of this study and should be evaluated in future studies.Higher CaO/Al_(2)O_(3)and CaO/SiO_(2)ratios in liquid slag promoted the dissolution of Al_(2)O_(3)-based in-clusions.The formation of solid phases in the slag should be prevented to improve dissolution of inclusions.To accurately simulate the dissolution of inclusions in liquid slag,in-situ observation of the dissolution of inclusions at the steel-slag interface is necessary.Using a combination of CSLM and scanning electron microscopy-energy dispersive spectroscopy,the composition and morphological evolution of the inclusions during their modification by the dissolved elements in steel were observed and analyzed.Although the in-situ observa-tion of MnS and TiN precipitations has been widely studied,the in-situ observation of the evolution of oxide inclusions in steel during so-lidification and heating processes has rarely been reported.The effects of temperature,heating and cooling rates,and inclusion character-istics on the formation of acicular ferrites(AFs)have been widely studied.At a cooling rate of 3-5 K/s,the order of AF growth rate in-duced by different inclusions,as reported in literature,is Ti-O<Ti-Ca-Zr-Al-O<Mg-O<Ti-Zr-Al-O<Mn-Ti-Al-O<Ti-Al-O<Zr-Ti-Al-O.Further comprehensive experiments are required to investigate the quantitative relationship between the formation of AFs and inclusions. 展开更多
关键词 INCLUSION STEEL in-situ observation confocal scanning laser microscopy
在线阅读 下载PDF
Molecular conformational effects on co-assembly systems of low-symmetric carboxylic acids investigated by scanning tunneling microscopy
3
作者 Yutong Xiong Ting Meng +3 位作者 Wendi Luo Bin Tu Shuai Wang Qingdao Zeng 《Chinese Journal of Structural Chemistry》 2025年第2期57-61,共5页
The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-d... The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-dicarboxylic acid(BCBDA))containing naphthalene rings on graphite surfaces have been investigated using scanning tunneling microscopy(STM).The transformation of nanostructures induced by the second components(EDA and PEBP-C4)have been also examined.Both CTTA and BCBDA molecules self-assemble at the 1-heptanoic acid(HA)/HOPG interface,forming porous network structures.The dimer represents the most elementary building unit due to the formation of double hydrogen bonds.Moreover,the flipping of naphthalene ring results in the isomerization of BCBDA molecule.The introduction of carboxylic acid derivative EDA disrupts the dimer,which subsequently undergoes a structural conformation to form a novel porous structure.Furthermore,upon the addition of pyridine derivative PEBP-C4,N–H⋯O hydrogen bonds are the dominant forces driving the three coassembled structures.We have also conducted density functional theory(DFT)calculations to determine the molecular conformation and analyze the mechanisms underlying the formation of nanostructures. 展开更多
关键词 Co-assembly CONFORMATION Hydrogen bonds scanning tunneling microscopy DFT calculations
原文传递
Application of high-temperature confocal scanning laser microscopy to investigate non-metallic inclusions in steel:a review
4
作者 N.Preisser Y.Wang +3 位作者 J.Cejka I.Gruber W.Mu S.K.Michelic 《Journal of Iron and Steel Research International》 2025年第2期334-352,共19页
High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations an... High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations and solidification,this method has gained traction in the field of non-metallic inclusion in steels in recent years.An overview of the experimental capabilities of HT-CSLM and the most important results of recent investigations regarding the topics of clean steel production are provided.It includes the formation of intragranular acicular ferrite(IAF)from the surface of non-metallic inclusions during the continuous cooling and heat treatment,which can be especially beneficial in the toughness of heat-affected zones of welded pieces.Furthermore,the investigation of agglomeration mechanisms of non-metallic inclusions(NMIs)in liquid steel is discussed to improve the insight into attraction forces between particles and clogging phenomena during continuous casting.Also,the dissolution of NMIs in various steelmaking slags can be observed by HT-CSLM to compare dissolution rates and mechanisms of NMI,where significant influences of temperature and chemical composition of the slag were shown.Last but not least,the experimental work regarding the interface between steel and slag is discussed,where novel techniques are currently being developed.A comprehensive summary of experimental techniques using HT-CSLM equipment to investigate different interactions of NMIs with steel and slag phases is compiled. 展开更多
关键词 Non-metallic inclusion STEEL High-temperature confocal scanning laser microscopy Interfacial phenomenon KINETICS
原文传递
Influence of Radio-Frequency Voltage on Electron Spin Resonance Spectroscopy in Scanning Tunneling Microscopy
5
作者 Jiaan Cao Lyuzhou Ye +1 位作者 Rui-Xue Xu Xiao Zheng 《Chinese Journal of Chemical Physics》 2025年第4期375-381,I0104,共8页
Over the last decade,the integra-tion of scanning tunneling mi-croscopy(STM)and electron spin resonance(ESR)spectroscopy has emerged as a powerful tool for measuring spin states of surface-adsorbed molecules.The radio... Over the last decade,the integra-tion of scanning tunneling mi-croscopy(STM)and electron spin resonance(ESR)spectroscopy has emerged as a powerful tool for measuring spin states of surface-adsorbed molecules.The radio-fre-quency voltage is a key physical quantity that influences STM-ESR spectra.However,the specific effect of radio-frequency voltage on the real-time electric current associated with STM-ESR sig-nal remains unclear.In this work,we employ the hierarchical equations of motion method to simulate the STM-ESR spectra of a single spin-1/2 surface-adsorbed molecule and track the temporal evolution of the electric current,thereby elucidating how the radio-frequency volt-age influences the features of STM-ESR spectra,the real-time electric current,and the char-acteristic frequencies conveyed by the electric current.These theoretical insights facilitate a deeper comprehension of experimental phenomena. 展开更多
关键词 Electron spin resonance scanning tunneling microscopy Radio-frequency volt-age Real-time electric current
在线阅读 下载PDF
Effect of CaO/SiO_(2)and CaO/Al_(2)O_(3)in CaO-Al_(2)O_(3)-SiO_(2)particles on desulfurization of molten steel studied by confocal scanning laser microscopy
6
作者 Chun-jie She Guo-jun Chen +1 位作者 Li-feng Zhang Ying Ren 《Journal of Iron and Steel Research International》 2025年第12期4207-4217,共11页
The instantaneous desulfurization of CaO-Al_(2)O_(3)-SiO_(2)slag particles in the molten steel was in situ observed using a high-temperature confocal scanning laser microscope.The desulfurization effect of CaO-Al_(2)O... The instantaneous desulfurization of CaO-Al_(2)O_(3)-SiO_(2)slag particles in the molten steel was in situ observed using a high-temperature confocal scanning laser microscope.The desulfurization effect of CaO-Al_(2)O_(3)-SiO_(2)slags with different compositions was discussed.The influence of CaO/Al_(2)O_(3)and CaO/SiO_(2)on the desulfurization effect was analyzed.It was shown that in the liquid phase range,the higher CaO/SiO_(2)and CaO/Al_(2)O_(3)can significantly improve the desulfurization effect of the slag.A dimensionless desulfurization index Sindex was introduced to evaluate the desulfurization ability of CaO-Al_(2)O_(3)-SiO_(2)slags quantitatively.The Sindex values of CaO-Al_(2)O_(3)-SiO_(2)with different compositions at 1550°C were calculated.It was suggested to use(65%-75%)CaO-(0-20%)SiO_(2)-(20%-40%)Al_(2)O_(3)slags to improve the molten steel desulfurization. 展开更多
关键词 DESULFURIZATION High-temperature confocal scanning laser microscopy Molten steel CaO-Al_(2)O_(3)-SiO_(2)particle
原文传递
Scanning Electron Microscopy of Antennae of Aphidoletes aphidimyza (Diptera: Cecidomyiidae) 被引量:6
7
作者 张洁 杨茂发 《Zoological Research》 CAS CSCD 北大核心 2008年第1期108-112,共5页
The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the ... The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the female was 1050μm. Six types of sensillae on the antenna were observed, viz. chaetica (Ch), trichoidea (Tr), basiconica (Ba), cavity (Ca), styloid (St) and circumfila (Ci) on the antennae of A. aphidimyza. Sensillae Ch had a long external-process, with a base surrounded by membranous sockets and a length of about 67.5 μm. Sensillae Tr were distally curved and inserted into a depression, 61.0μm long. Sensillae Ba were peg-like and 4.7μm long on the antennae. Sensillae Ca were pit-like in appearance and the diameter of the pit was 1.2μm. Sensilla St was found on the second sub-segment flagellum of the male antennae. The length of the sensilla was about 21 μm and the diameter was 1.5μm. The circurnfila, which are a unique type of sensilla found only on cecidomyiid antennae, formed loops around each of the antennal sub-segments, and were attached to the surface by a series of stalks. Sensilla St was only present on male antenna. The number of Ba and Tr was almost the same in both sexes. There were more Sensilla Ca on the male antenna than on the female, while there was more Ch on the female. 展开更多
关键词 Aphidoletes aphidimyza scanning electron microscopy ANTENNA Sensillae ULTRASTRUCTURE
在线阅读 下载PDF
Corrosion behavior of aluminum alloys in Na_2SO_4 solution using the scanning electrochemical microscopy technique 被引量:9
8
作者 He-rong Zhou Xiao-gang Li +2 位作者 Chao-fang Dong Kui Xiao Tai Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2009年第1期84-88,共5页
The corrosion behavior of aluminum alloys 1060 and 2A12 in a 10 mM Na2SO4+5 mM KI solution was investigated by scanning electrochemical microscopy (SECM) and scanning electron microscopy (SEM). The potential topo... The corrosion behavior of aluminum alloys 1060 and 2A12 in a 10 mM Na2SO4+5 mM KI solution was investigated by scanning electrochemical microscopy (SECM) and scanning electron microscopy (SEM). The potential topography and corrosion morphology results show that the potential of the sample surface over the same area changes with the increase of immersion time. The corrosion area becomes large, and the potential becomes more negative. The corrosion potential of the 2A12 alloy surface is lower than that of 1060 aluminum, and 2A12 alloy becomes easily corrosive. This is the reason that preferential dissolution in the boundary region of some intermetallic particles (IMPs) occurs and different dissolution behaviors are associated with different types of IMPs because of different potentials. 展开更多
关键词 aluminum alloys corrosion behavior intermetallic particles scanning electrochemical microscopy (SECM)
在线阅读 下载PDF
Imaging of Activity of Horseradish Peroxidase at β-Cyclodextrin Polymer by Scanning Electrochemical Microscopy 被引量:13
9
作者 XiaoLeiWANG YongXiangSHI +1 位作者 ZengLiangBAI WenRuiJIN 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第2期214-215,共2页
The activity of horseradish peroxidase at b-cyclodextrin polymer was imaged by scanning electrochemical microscopy using 3, 3', 5, 5'-tetramethylbenzide and H2O2 as the substrates.
关键词 scanning electrochemical microscopy horseradish peroxidase.
在线阅读 下载PDF
Non-invasive and low-artifact in vivo brain imaging by using a scanning acoustic-photoacoustic dual mode microscopy 被引量:3
10
作者 Wentian Chen Chao Tao +3 位作者 Zizhong Hu Songtao Yuan Qinghuai Liu Xiaojun Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第4期385-393,共9页
Photoacoustic imaging is a potential candidate for in vivo brain imaging,whereas,its imaging performance could be degraded by inhomogeneous multi-layered media,consisted of scalp and skull.In this work,we propose a lo... Photoacoustic imaging is a potential candidate for in vivo brain imaging,whereas,its imaging performance could be degraded by inhomogeneous multi-layered media,consisted of scalp and skull.In this work,we propose a low-artifact photoacoustic microscopy(LAPAM)scheme,which combines conventional acoustic-resolution photoacoustic microscopy with scanning acoustic microscopy to suppress the reflection artifacts induced by multi-layers.Based on similar propagation characteristics of photoacoustic signals and ultrasonic echoes,the ultrasonic echoes can be employed as the filters to suppress the reflection artifacts to obtain low-artifact photoacoustic images.Phantom experiment is used to validate the effectiveness of this method.Furthermore,LAPAM is applied for in-vivo imaging mouse brain without removing the scalp and the skull.Experimental results show that the proposed method successfully achieves the low-artifact brain image,which demonstrates the practical applicability of LAPAM.This work might improve the photoacoustic imaging quality in many biomedical applications which involve tissues with complex acoustic properties,such as brain imaging through scalp and skull. 展开更多
关键词 photoacoustic microscopy scanning acoustic microscopy NONINVASIVE low-artifact brain imaging
原文传递
Scanning transmission electron microscopy: A review of high angle annular dark field and annular bright field imaging and applications in lithium-ion batteries 被引量:2
11
作者 Yu-Xin Tong Qing-Hua Zhang Lin Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期23-34,共12页
Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. H... Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. High angle annular dark field(HAADF) and annular bright field(ABF) imaging of the aberration-corrected STEM are widely used due to their high-resolution capabilities and easily interpretable image contrasts. However, HAADF mode of the STEM is still limited in detecting light elements due to the weak electron-scattering power. ABF mode of the STEM could detect light and heavy elements simultaneously, providing unprecedented opportunities for probing unknown structures of materials. Atomiclevel structure investigation of materials has been achieved by means of these imaging modes, which is invaluable in many fields for either improving properties of materials or developing new materials. This paper aims to provide a introduction of HAADF and ABF imaging techniques and reviews their applications in characterization of cathode materials, study of electrochemical reaction mechanisms, and exploring the effective design of lithium-ion batteries(LIBs). The future prospects of the STEM are also discussed. 展开更多
关键词 scanning transmission electron microscopy high angle annular dark field annular bright field lithium-ion batteries
原文传递
Scanning tunneling microscopic investigation on morphology of magnetic Weyl semimetal YbMnBi2 被引量:1
12
作者 Zhen Zhu Dong Yan +10 位作者 Xiao-Ang Nie Hao-Ke Xu Xu Yang Dan-Dan Guan Shiyong Wang Yao-Yi Li Canhua Liu Jun-Wei Liu Hui-Xia Luo Hao Zheng Jin-Feng Jia 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第7期87-90,共4页
YbMnBi2 is a recently discovered time-reversal-symmetry breaking type-Ⅱ Weyl semimetal.However, as a representation of the new category of topological matters, the scanning tunneling microcopy(STM) results on such im... YbMnBi2 is a recently discovered time-reversal-symmetry breaking type-Ⅱ Weyl semimetal.However, as a representation of the new category of topological matters, the scanning tunneling microcopy(STM) results on such important material are still absent.Here, we report the STM investigations on the morphology of vacuum cleaved single crystalline YbMnBi2 samples.A hill and valley type of topography is observed on the YbMnBi2 surface, which is consistent with the non-layer nature of its crystal structure.Analysis of STM images yields the information of the index of the vicinal surface.Our results here lay a playground of future atomic scale research on YbMnBi2. 展开更多
关键词 WEYL SEMIMETAL topological INSULATOR scanning TUNNELING microscopy
原文传递
Multi-objective Optimal Design of High Frequency Probe for Scanning Ion Conductance Microscopy 被引量:2
13
作者 GUO Renfei ZHUANG Jian +2 位作者 MA Li LI Fei YU Dehong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第1期195-203,共9页
Scanning ion conductance microscopy(SICM) is an emerging non-destructive surface topography characterization apparatus with nanoscale resolution. However, the low regulating frequency of probe in most existing modul... Scanning ion conductance microscopy(SICM) is an emerging non-destructive surface topography characterization apparatus with nanoscale resolution. However, the low regulating frequency of probe in most existing modulated current based SICM systems increases the system noise, and has difficulty in imaging sample surface with steep height changes. In order to enable SICM to have the capability of imaging surfaces with steep height changes, a novel probe that can be used in the modulated current based bopping mode is designed. The design relies on two piezoelectric ceramics with different travels to separate position adjustment and probe frequency regulation in the Z direction. To fiarther improve the resonant frequency of the probe, the material and the key dimensions for each component of the probe are optimized based on the multi-objective optimization method and the finite element analysis. The optimal design has a resonant frequency of above 10 kHz. To validate the rationality of the designed probe, microstructured grating samples are imaged using the homebuilt modulated current based SICM system. The experimental results indicate that the designed high frequency probe can effectively reduce the spike noise by 26% in the average number of spike noise. The proposed design provides a feasible solution for improving the imaging quality of the existing SICM systems which normally use ordinary probes with relatively low regulating frequency. 展开更多
关键词 scanning ion conductance microscopy(SICM) multi-objective optimization high frequency probe finite element analysis imaging quality
在线阅读 下载PDF
50 years of scanning electron microscopy of bone——a comprehensive overview of the important discoveries made and insights gained into bone material properties in health,disease,and taphonomy 被引量:2
14
作者 Furqan A.Shah Krisztina Ruscsák Anders Palmquist 《Bone Research》 SCIE CAS CSCD 2019年第2期123-137,共15页
Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair.The scanning electron microscope (SEM) is among the most frequently used instrument... Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair.The scanning electron microscope (SEM) is among the most frequently used instruments for examining bone.It offers the key advantage of very high spatial resolution coupled with a large depth of field and wide field of view.Interactions between incident electrons and atoms on the sample surface generate backscattered electrons,secondary electrons,and various other signals including X-rays that relay compositional and topographical information.Through selective removal or preservation of specific tissue components (organic,inorganic,cellular,vascular),their individual contribution(s) to the overall functional competence can be elucidated.With few restrictions on sample geometry and a variety of applicable sample-processing routes,a given sample may be conveniently adapted for multiple analytical methods.While a conventional SEM operates at high vacuum conditions that demand clean,dry,and electrically conductive samples,non-conductive materials (e.g.,bone) can be imaged without significant modification from the natural state using an environmental scanning electron microscope.This review highlights important insights gained into bone microstructure and pathophysiology,bone response to implanted biomaterials,elemental analysis,SEM in paleoarchaeology,3D imaging using focused ion beam techniques,correlative microscopy and in situ experiments.The capacity to image seamlessly across multiple length scales within the meso-micro-nano-continuum,the SEM lends itself to many unique and diverse applications,which attest to the versatility and user-friendly nature of this instrument for studying bone.Significant technological developments are anticipated for analysing bone using the SEM. 展开更多
关键词 scanning electron microscopy COMPREHENSIVE OVERVIEW important discoveries
暂未订购
Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy 被引量:1
15
作者 Melike Balikoglu-Yilmaz Tolga Yilmaz +4 位作者 Sule Cetinel Umit Taskin Ayse Banu Esen Muhittin Taskapili Timur Kose 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期534-540,共7页
AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidi... AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidiode laser.METHODS:This prospective study included 30consecutive patients with nasolacrimal duct obstruction who underwent EXT-,EN-,or TC-DCR.Thirty removed lacrimal stent fragments and conjunctival samples were cultured.The lacrimal stent biofilms were examined by scanning electron microscopy(SEM).RESULTS:Eleven(36.7%)of the 30 lacrimal stent cultures were positive for aerobic bacteria(most commonly Staphylococcus epidermidis and Pseudomonas aeruginosa).However anaerobic bacteria and fungi were not identified in the lacrimal stent cultures.Twenty-seven(90%)patients had biofilmpositive lacrimal stents.The conjunctival culture positivity after the DCR,biofilm positivity on stents,the grade of biofilm colonization,and the presence of mucus and coccoid and rod-shaped organisms did not significantly differ between any of the groups(P】0.05).However,a significant difference was found when the SEM results were compared to the results of the lacrimal stent and conjunctival cultures(P【0.001).CONCLUSION:Type of dacryocystorhinostomy(DCR)surgery did not affect the biofilm colonization of the lacrimal stents.SEM also appears to be more precise than microbiological culture for evaluating the presence of biofilms on lacrimal stents. 展开更多
关键词 biofilms nasolacrimal duct obstruction EPIPHORA DACRYOCYSTITIS scanning electron microscopy
原文传递
Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study 被引量:5
16
作者 Jun Sang Yoo Seok-Woo Chang +8 位作者 So Ram Oh Hiran Perinpanayagam Sang-Min Lim Yeon-Jee Yoo Yeo-Rok Oh Sang-Bin Woo Seung-Hyun Han Qiang Zhu Kee-Yeon Kum 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第4期227-232,共6页
The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted huma... The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted human premolars(n560) were instrumented to an apical size #50/0.06 using ProF ile and treated as follows: Group 1(n510) was filled with phosphate buffered saline(PBS); Group 2(n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3(n520) was obturated orthograde with a paste of OrthoM TA(BioM TA, Seoul, Korea) and PBS; and Group 4(n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoM TA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material(IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoM TA-filled roots(Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots(Group 4). Therefore, the orthograde obturation of root canals with OrthoM TA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. 展开更多
关键词 bacterial entombment intratubular mineralization orthograde canal obturation scanning electron microscopy tag-like structure
暂未订购
EFFECT OF THE TOTAL SAPONIN OF DIPSACUS ASPER ON INTRACELLULAR FREE CALCIUM CONCENTRATION IN THE CELLULAR MODEL OF ALZHEIMER'S DISEASE-SCANNING CONFOCAL MICROSCOPY 被引量:2
17
作者 钱亦华 任惠民 +3 位作者 胡海涛 刘勇 杨广德 王春梅 《Academic Journal of Xi'an Jiaotong University》 2001年第2期159-163,共5页
Objective To study the effect of ginsenoside Rb1 and total saponin of dipsacus asper on intracellular free calcium concentration mediated by β amyloid protein.So as to lay a foundation for developing effective Chines... Objective To study the effect of ginsenoside Rb1 and total saponin of dipsacus asper on intracellular free calcium concentration mediated by β amyloid protein.So as to lay a foundation for developing effective Chinese traditional medicine to treat Alzheimer’s disease.Methods The technique of laser scanning confocal microscopy combining primary cultured neurons was adopted to quantitatively analyze the change of [Ca 2+ ] i.Results The [Ca 2+ ] i of primary cultured hippocampal neurons was nmol·L -1 on basal levels.Control group showed obvious change of calcium vibration,[Ca 2+ ] i was elevated to nmol·L -1 .The peak of [Ca 2+ ] i of Rb1 group reached nmol·L -1 and was lower than that of control group .The tSDA group displayed distinct change of calcium vibration too,and [Ca 2+ ] i reached nmol·L -1 .There was a significant difference in [Ca 2+ ] i between control and tSDA group .Conclusion The research indicated that one of mechanisms by which Rb1 and tSDA protected the neurons was to maintain the balance of [Ca 2+ ] i. 展开更多
关键词 cultured neurons β amyloid protein Alzheimer’s disease scanning confocal microscopy
暂未订购
Modern applications of scanning electrochemical microscopy in the analysis of electrocatalytic surface reactions 被引量:2
18
作者 C.Hyun Ryu Yunwoo Nam Hyun S.Ahn 《Chinese Journal of Catalysis》 SCIE EI CAS CSCD 2022年第1期59-70,共12页
Development of reaction-tailored electrocatalysts is becoming increasingly important as energy and environment are among key issues governing our sustainable future.Electrocatalysts are inherently optimized for applic... Development of reaction-tailored electrocatalysts is becoming increasingly important as energy and environment are among key issues governing our sustainable future.Electrocatalysts are inherently optimized for application towards reactions of interest in renewable energy,such as those involved in water splitting and artificial photosynthesis,owing to its energy efficiency,simple fabrication,and ease of operation.In this view,it is important to secure logical design principles for the synthesis of electrocatalysts for various reactions of interest,and also understand their catalytic mechanisms in the respective reactions for improvements in further iterations.In this review,we introduce several key methods of scanning electrochemical microscopy(SECM)in its applications towards electrocatalysis.A brief history and a handful of seminal works in the SECM field is introduced in advancing the synthetic designs of electrocatalysts and elucidation of the operating mechanism.New developments in nano-sizing of the electrodes in attempts for improved spatial resolution of SECM is also introduced,and the application of nanoelectrodes towards the investigation of formerly inaccessible single catalytic entities is shared. 展开更多
关键词 scanning electrochemical microscopy ELECTROCATALYSIS Surface reaction Electroanalytical chemistry In situ electrochemical analysis Direct quantification
在线阅读 下载PDF
The scanning tunneling microscopy and spectroscopy of GaSb_(1-x)Bi_(x) films of a few-nanometer thickness grown by molecular beam epitaxy 被引量:2
19
作者 Fangxing Zha Qiuying Zhang +4 位作者 Haoguang Dai Xiaolei Zhang Li Yue Shumin Wang Jun Shao 《Journal of Semiconductors》 EI CAS CSCD 2021年第9期42-46,共5页
The ultrahigh vacuum scanning tunneling microscope(STM)was used to characterize the GaSb_(1-x)Bi_(x) films of a few nanometers thickness grown by the molecular beam epitaxy(MBE)on the GaSb buffer layer of 100 nm with ... The ultrahigh vacuum scanning tunneling microscope(STM)was used to characterize the GaSb_(1-x)Bi_(x) films of a few nanometers thickness grown by the molecular beam epitaxy(MBE)on the GaSb buffer layer of 100 nm with the GaSb(100)substrates.The thickness of the GaSb_(1-x)Bi_(x) layers of the samples are 5 and 10 nm,respectively.For comparison,the GaSb buffer was also characterized and its STM image displays terraces whose surfaces are basically atomically flat and their roughness is generally less than 1 monolayer(ML).The surface of 5 nm GaSb_(1-x)Bi_(x) film reserves the same terraced morphology as the buffer layer.In contrast,the morphology of the 10 nm GaSb_(1-x)Bi_(x) film changes to the mound-like island structures with a height of a few MLs.The result implies the growth mode transition from the two-dimensional mode as displayed by the 5 nm film to the Stranski-Krastinov mode as displayed by the 10 nm film.The statistical analysis with the scanning tunneling spectroscopy(STS)measurements indicates that both the incorporation and the inhomogeneity of Bi atoms increase with the thickness of the GaSb_(1-x)Bi_(x) layer. 展开更多
关键词 scanning tunneling microscopy molecular beam epitaxy semiconductor surface
在线阅读 下载PDF
SCANNING TUNNELING MICROSCOPY OF (CrFe)7C3 被引量:1
20
《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1995年第1期19-22,共4页
The microstructure of(CrFe)_7C_3 has been studied with scanning tunneling microscopy.It shows that a carbide consists of colonies which are full of stacking faults. The stacking faults in one colony are parallel while... The microstructure of(CrFe)_7C_3 has been studied with scanning tunneling microscopy.It shows that a carbide consists of colonies which are full of stacking faults. The stacking faults in one colony are parallel while those in different colonies lie at angle with each other. 展开更多
关键词 scanning tunneling microscopy stacking fault (CrFe)_7C_3
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部