期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
儿童长骨骺板损伤39例治疗
1
作者 杨忠奎 李帮平 +2 位作者 赵庆云 唐绍涛 龚兰英 《黔南民族医专学报》 1997年第3期23-24,共2页
作者自1993年6月——1996年6月运用Saltet——Harris分类法。对39例儿童长骨骺板损伤的患儿进行手法复位或切开复位内因定(钢丝、螺纹钉、克氏针,)术等治疗。其中男性26例,女性13例,年龄最大15岁,最小3岁,平均10.23岁,随访时间最长2年,... 作者自1993年6月——1996年6月运用Saltet——Harris分类法。对39例儿童长骨骺板损伤的患儿进行手法复位或切开复位内因定(钢丝、螺纹钉、克氏针,)术等治疗。其中男性26例,女性13例,年龄最大15岁,最小3岁,平均10.23岁,随访时间最长2年,最短3月,平均随访0.9年。骺板损伤中,最常见是:桡骨远端10例,其次是肱骨内上髁7例,肱骨外髁6例,肱骨上端4例,其余各部位均为1——2例。作者认为:通过Salter——Harris分类法,对骨骺板损伤进行分类后,采取相应的治疗手段,进行治疗,可以降低成角畸形,骨桥生长及短缩畸形等骨骺损伤后遗症的发生率。 展开更多
关键词 儿童在长骨骺板损伤 salter——harris分类
暂未订购
Distal femoral physeal crush injury with metaphyseal comminution - A report of two cases and a new perspective to physeal injury 被引量:1
2
作者 Prateek Behera Nirmal Raj Gopinathan +3 位作者 Avinash Kumar Balaji Saibaba Pebam Sudesh Rakesh John 《Chinese Journal of Traumatology》 CAS CSCD 2017年第6期366-369,共4页
The physis of a long bone may get 'sandwiched' and crushed between the metaphysis and the epiphysis if it is traumatically loaded along its long axis. Such a physeal injury may lead to complications like angular def... The physis of a long bone may get 'sandwiched' and crushed between the metaphysis and the epiphysis if it is traumatically loaded along its long axis. Such a physeal injury may lead to complications like angular deformities and growth restrictions and hence, management of such injuries requires adequate planning and attentive execution. Two patients with distal femoral physeal crush injury were treated using a ring fixator such that one ring had the wires passing through the epiphysis and the other through the femoral shaft. On table image intensifier controlled distraction of the crushed physis was done to bring the height of the physis similar to that of the opposite limb. Patients were followed up for more than two years clinically and radio- logically. There was no clinical or radiological angular deformity of the operated limbs. MRI scans showed intact physes with no physeal bar formation in either of the two patients. The distraction obtained by the ring fixator appears to have provided ample 'breathing space' to the compressed physis and that the growth potential may have been re-gained by the procedure. However, two years is a relatively short duration of follow-up and further follow-up of longer duration and in greater number of patients is needed to gauge the actual effectiveness of the technque used bv us. 展开更多
关键词 salter harris classification Physeal injuries Distal femoral physis DISTRACTION Ring fixator
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部