The galvanic corrosion of the Q-phase/Al couple in 0.1 M NaCl solutions has been studied using the scanning vibrating electrode technique (SVET)f the scanning ion-selective electrode technique (SIET) and energy disper...The galvanic corrosion of the Q-phase/Al couple in 0.1 M NaCl solutions has been studied using the scanning vibrating electrode technique (SVET)f the scanning ion-selective electrode technique (SIET) and energy dispersive X-ray spectroscopy (EDX). The galvanic corrosion of the Q-phase/Al couple was found to be dependent on pH and immersion time. Current density maps obtained by SVET shows that the anodic oxidation processes emerge from Al in a localized manner in pH 2 and 6 solutions but is initiated in a uniform manner in pH 13 solution, whereas, the cathodic processes are more homogeneously distributed over the Q-phase at pH 2.6 and 13. It is seen that the Q-phase remains cathodic in the Q-phase/Al couple in acidic, neutral and alkaline solutions indicating that the galvanic polarity of the Q-phase is independent of pH. The effect of the galvanic corrosion was largest at pH 2 and 13 compared to pH 6. The pH map obtained by SIET indicates that the galvanic activity of the Q-phase/Al couple proceeds via heavy alkalization of the Q-phase surface with the generation of appreciable amounts of OH~ ions. The enrichment of Cu indicated by EDX is responsible for the observed cathodic activity of the Q-phase in the Q-phase/Al couple.展开更多
The electrochemical corrosion of ductile pipes(DPs)in drinking water distribution systems(DWDS)has a crucial impact on cement-mortar lining(CML)failure and metal release,potentially leading to drinking water quality d...The electrochemical corrosion of ductile pipes(DPs)in drinking water distribution systems(DWDS)has a crucial impact on cement-mortar lining(CML)failure and metal release,potentially leading to drinking water quality deterioration and posing a risk to public health.An in-situ scanning vibrating electrode technique(SVET)with micron-scale resolution,microscopic scale detection and water quality analysis were used to investigate the corrosion behavior and metal release from DPs throughout the whole CML failure process.Metal pollutants release occurred at three different stages of CML failure process,and there are potential risks of water quality deterioration exceeding the maximum allowable levels set by national standards in the partial failure stage and lining peeling stage.Furthermore,the effects of water chemistry(Cl^(−),SO_(4)^(2−),NO_(3)−,and Ca^(2+))on corrosion scale growth and iron release activity,were investigated during the CML partial failure stage.Results showed that the CML failure process in DPs was accelerated by the autocatalysis of localized corrosion.Cl^(−)was found to damage the uncorroded metal surface,while SO_(4)^(2−)mainly dissolved the corrosion scale surface,increasing iron release.Both the oxidation of NO_(3)−and selective sedimentation of Ca2+were found to enhance the stability of corrosion scales and inhibit iron release.展开更多
采用10 kJ/cm和15 k J/cm两种焊接热输入对Q1100超高强钢进行熔化极气体保护焊,研究焊接接头的组织性能及局部腐蚀行为。结果表明:两种热输入焊接接头的焊缝组织主要为针状铁素体和少量的粒状贝氏体,粗晶区组织均为板条贝氏体,细晶区组...采用10 kJ/cm和15 k J/cm两种焊接热输入对Q1100超高强钢进行熔化极气体保护焊,研究焊接接头的组织性能及局部腐蚀行为。结果表明:两种热输入焊接接头的焊缝组织主要为针状铁素体和少量的粒状贝氏体,粗晶区组织均为板条贝氏体,细晶区组织均为板条贝氏体和粒状贝氏体,临界相变区组织为多边形铁素体、马奥岛和碳化物的混合组织。两种热输入焊接接头中电荷转移电阻均为母材>热影响区>焊缝区,母材耐蚀性最好,热影响区次之,焊缝区耐蚀性最差。在腐蚀过程中,焊缝区作为阳极最先被腐蚀,当腐蚀一定时间后,腐蚀位置发生改变,阳极腐蚀区域转移到母材区,而焊缝区作为阴极得到保护。热输入为10 k J/cm时,焊接接头具有更好的低温韧性和耐蚀性,其焊缝和热影响区-40℃冲击功分别为46.5 J和30.2 J。展开更多
目的对5083铝合金在海水环境下的腐蚀行为进行深入的探索。方法在3%Na Cl溶液条件下,通过扫描振动电极技术(SVET)对5083铝合金的微小区域进行了原位测量,得到表面区域电位梯度的变化情况,结合交流阻抗测试,以及扫描电镜和能谱分析等方法...目的对5083铝合金在海水环境下的腐蚀行为进行深入的探索。方法在3%Na Cl溶液条件下,通过扫描振动电极技术(SVET)对5083铝合金的微小区域进行了原位测量,得到表面区域电位梯度的变化情况,结合交流阻抗测试,以及扫描电镜和能谱分析等方法,研究5083铝合金腐蚀的发生、发展机理。结果由于Zn和S等元素的偏析,腐蚀过程中,夹杂物等第二相周围优先溶解,致使铝合金基体裸露在溶液中。随着反应的持续形成点蚀,腐蚀电流使腐蚀区域的电位高于基体电位。浸泡3 h,最大电位差为15.72 m V,浸泡5 h,最大电位差达到20.06 m V。结论 5083铝合金在海水环境下夹杂物的周围优先溶解,然后是电位高于基体电位的第二相发生溶解,同时钝化膜破裂处也发生腐蚀,最终这些区域形成点蚀。展开更多
In order to analyze the effect of scratch on the corrosion behaviour of a calcium phosphate conversion coating(CPCC)on AZ80,the electrochemical testing,scanning vibrating electrode technique(SVET),immersion test and h...In order to analyze the effect of scratch on the corrosion behaviour of a calcium phosphate conversion coating(CPCC)on AZ80,the electrochemical testing,scanning vibrating electrode technique(SVET),immersion test and hydrogen evolution experiment were performed to study the corrosion resistance of AZ80,AZ80 with CPCC and coated AZ80 with scratch.The results show that the coating improves the corrosion resistance of the AZ80 from a current density of(85±4)to(4±1)μA/cm^(2).When the coating was damaged,its protection on substrate would be reduced.The scratch with a length of around 12 mm on the coating reduced the corrosion resistance to a current density of(39±1)μA/cm^(2).In addition,the corrosion occurred initially in the scratch area and the corrosion site first occurred at the junction of the scratch and the coating.Besides,the micro corrosion mechanism of the specimen containing scratch was clarified.展开更多
基金financially supported by the National Natural Science Foundation of China (Grant No. 51571201)
文摘The galvanic corrosion of the Q-phase/Al couple in 0.1 M NaCl solutions has been studied using the scanning vibrating electrode technique (SVET)f the scanning ion-selective electrode technique (SIET) and energy dispersive X-ray spectroscopy (EDX). The galvanic corrosion of the Q-phase/Al couple was found to be dependent on pH and immersion time. Current density maps obtained by SVET shows that the anodic oxidation processes emerge from Al in a localized manner in pH 2 and 6 solutions but is initiated in a uniform manner in pH 13 solution, whereas, the cathodic processes are more homogeneously distributed over the Q-phase at pH 2.6 and 13. It is seen that the Q-phase remains cathodic in the Q-phase/Al couple in acidic, neutral and alkaline solutions indicating that the galvanic polarity of the Q-phase is independent of pH. The effect of the galvanic corrosion was largest at pH 2 and 13 compared to pH 6. The pH map obtained by SIET indicates that the galvanic activity of the Q-phase/Al couple proceeds via heavy alkalization of the Q-phase surface with the generation of appreciable amounts of OH~ ions. The enrichment of Cu indicated by EDX is responsible for the observed cathodic activity of the Q-phase in the Q-phase/Al couple.
基金supported by the National Natural Science Foundation of China(Nos.51808158,52170101,and 52200116)Tianjin Natural Science Foundation(No.23JCYBJC00640).
文摘The electrochemical corrosion of ductile pipes(DPs)in drinking water distribution systems(DWDS)has a crucial impact on cement-mortar lining(CML)failure and metal release,potentially leading to drinking water quality deterioration and posing a risk to public health.An in-situ scanning vibrating electrode technique(SVET)with micron-scale resolution,microscopic scale detection and water quality analysis were used to investigate the corrosion behavior and metal release from DPs throughout the whole CML failure process.Metal pollutants release occurred at three different stages of CML failure process,and there are potential risks of water quality deterioration exceeding the maximum allowable levels set by national standards in the partial failure stage and lining peeling stage.Furthermore,the effects of water chemistry(Cl^(−),SO_(4)^(2−),NO_(3)−,and Ca^(2+))on corrosion scale growth and iron release activity,were investigated during the CML partial failure stage.Results showed that the CML failure process in DPs was accelerated by the autocatalysis of localized corrosion.Cl^(−)was found to damage the uncorroded metal surface,while SO_(4)^(2−)mainly dissolved the corrosion scale surface,increasing iron release.Both the oxidation of NO_(3)−and selective sedimentation of Ca2+were found to enhance the stability of corrosion scales and inhibit iron release.
文摘采用10 kJ/cm和15 k J/cm两种焊接热输入对Q1100超高强钢进行熔化极气体保护焊,研究焊接接头的组织性能及局部腐蚀行为。结果表明:两种热输入焊接接头的焊缝组织主要为针状铁素体和少量的粒状贝氏体,粗晶区组织均为板条贝氏体,细晶区组织均为板条贝氏体和粒状贝氏体,临界相变区组织为多边形铁素体、马奥岛和碳化物的混合组织。两种热输入焊接接头中电荷转移电阻均为母材>热影响区>焊缝区,母材耐蚀性最好,热影响区次之,焊缝区耐蚀性最差。在腐蚀过程中,焊缝区作为阳极最先被腐蚀,当腐蚀一定时间后,腐蚀位置发生改变,阳极腐蚀区域转移到母材区,而焊缝区作为阴极得到保护。热输入为10 k J/cm时,焊接接头具有更好的低温韧性和耐蚀性,其焊缝和热影响区-40℃冲击功分别为46.5 J和30.2 J。
文摘目的对5083铝合金在海水环境下的腐蚀行为进行深入的探索。方法在3%Na Cl溶液条件下,通过扫描振动电极技术(SVET)对5083铝合金的微小区域进行了原位测量,得到表面区域电位梯度的变化情况,结合交流阻抗测试,以及扫描电镜和能谱分析等方法,研究5083铝合金腐蚀的发生、发展机理。结果由于Zn和S等元素的偏析,腐蚀过程中,夹杂物等第二相周围优先溶解,致使铝合金基体裸露在溶液中。随着反应的持续形成点蚀,腐蚀电流使腐蚀区域的电位高于基体电位。浸泡3 h,最大电位差为15.72 m V,浸泡5 h,最大电位差达到20.06 m V。结论 5083铝合金在海水环境下夹杂物的周围优先溶解,然后是电位高于基体电位的第二相发生溶解,同时钝化膜破裂处也发生腐蚀,最终这些区域形成点蚀。
基金financially supported by the National Natural Science Foundation of China(Nos.52071036,51701027)the Fundamental Research Funds for the Central Universities,China(Nos.2020CDJQY-A002,2021CDJCGJ009)the National Key Research and Development Program of China(Nos.2016YFB0301100,2016YFB0101700)。
文摘In order to analyze the effect of scratch on the corrosion behaviour of a calcium phosphate conversion coating(CPCC)on AZ80,the electrochemical testing,scanning vibrating electrode technique(SVET),immersion test and hydrogen evolution experiment were performed to study the corrosion resistance of AZ80,AZ80 with CPCC and coated AZ80 with scratch.The results show that the coating improves the corrosion resistance of the AZ80 from a current density of(85±4)to(4±1)μA/cm^(2).When the coating was damaged,its protection on substrate would be reduced.The scratch with a length of around 12 mm on the coating reduced the corrosion resistance to a current density of(39±1)μA/cm^(2).In addition,the corrosion occurred initially in the scratch area and the corrosion site first occurred at the junction of the scratch and the coating.Besides,the micro corrosion mechanism of the specimen containing scratch was clarified.