期刊文献+
共找到184篇文章
< 1 2 10 >
每页显示 20 50 100
Sutureless aortic valve and post-operative atrial fibrillation: Fiveyear outcomes from a propensity matched cohort study
1
作者 Thomas French Sanjeet Singh Avtaar Singh +4 位作者 Vincenzo Giordano Charilaos-Panagiotis Koutsogiannidis Kelvin Hao Han Lim Renzo Pessotto Vipin Zamvar 《World Journal of Cardiology》 2025年第4期53-63,共11页
BACKGROUND The Perceval Sorin S(perceval valve)is a sutureless bioprosthetic designed for use in a high-risk cohort who may not be suitable for transcatheter aortic valve implantation or a conventional surgical aortic... BACKGROUND The Perceval Sorin S(perceval valve)is a sutureless bioprosthetic designed for use in a high-risk cohort who may not be suitable for transcatheter aortic valve implantation or a conventional surgical aortic valve replacement(AVR).AIM To compare five-year post-operative outcomes in a cohort undergoing isolated AVR with the perceval valve to a contemporary cohort undergoing surgical AVR with a sutured bioprosthesis.METHODS This study was a retrospective,cohort study at a single tertiary unit.Between 2017 and 2023,982 suitable patients were identified.174 Perceval valve replacements were matched to 174 sutured valve replacements.Cohort characteristics,intra-operative details,and post-operative outcomes were compared between the two groups.RESULTS Time under the aortic cross-clamp(P<0.001),time on the cardiopulmonary bypass(P<0.001)and total operative time(P<0.001)were significantly reduced in the Perceval group.Patients in the Perceval valve group were at a lower risk of postoperative pneumonia[odds ratio(OR)=0.53(0.29-0.94)]and atrial fibrillation[OR=0.58(0.36-0.93)].After propensity-matching,all-cause mortality did not significantly differ between the two groups in the five-year follow-up period.Larger valve sizes conferred an increased risk of mortality(P=0.020).CONCLUSION Sutureless surgical AVR(SAVR)is a safe and efficient alternative to SAVR with a sutured bioprosthesis,and may confer a reduced risk of post-operative atrial fibrillation.Clinician tendency towards‘oversizing’sutureless aortic valves translates into adverse clinical outcomes.Less time on the cardiopulmonary bypass circuit allows for the treatment of otherwise high-risk patients. 展开更多
关键词 sutureless valves Aortic valve replacements Survival Atrial fibrillation
暂未订购
改良Sutureless技术治疗完全性肺静脉异位引流 被引量:2
2
作者 王珊 施焘 +4 位作者 滕晓 于冰 吕小东 李守军 花中东 《中国胸心血管外科临床杂志》 CSCD 北大核心 2022年第5期619-623,共5页
目的介绍一种改良Sutureless技术及其治疗完全性肺静脉异位引流的手术效果。方法回顾性分析阜外医院小儿心外科2014—2019年行改良Sutureless技术治疗11例完全性肺静脉异位引流患者的临床资料,其中男4例、女7例,中位手术年龄1.4(0.3,27... 目的介绍一种改良Sutureless技术及其治疗完全性肺静脉异位引流的手术效果。方法回顾性分析阜外医院小儿心外科2014—2019年行改良Sutureless技术治疗11例完全性肺静脉异位引流患者的临床资料,其中男4例、女7例,中位手术年龄1.4(0.3,27.0)个月,中位体重4.3(3.5,8.5)kg。心上型6例(54.5%)、心下型5例(45.5%)。术前重度肺动脉高压5例(45.5%),术前肺静脉梗阻3例(27.3%)。并将其手术治疗结果与同期行传统手术方法治疗的10例患儿进行比较。结果中位随访时间12(1~65)个月。随访期间,改良Sutureless组未出现死亡及术后肺静脉梗阻事件,在围术期资料及免除再梗阻等方面均较传统手术组显示出优势,但差异无统计学意义(P>0.05)。改良Sutureless组术后生存优于传统手术组(P=0.049)。结论包括“先部分缝合再切开”及“肺静脉内膜外翻扩大开口”等创新点的改良Sutureless技术,是一种治疗完全性肺静脉异位引流的安全可靠的方法,术后近期效果良好。 展开更多
关键词 改良sutureless技术 完全性肺静脉异位引流 外科手术
原文传递
Sutureless技术矫治新生儿完全性肺静脉异位引流42例护理配合 被引量:1
3
作者 欧阳淑怡 谢庆 +4 位作者 卢嫦青 岑坚正 李晓华 冯旭林 黄世杰 《齐鲁护理杂志》 2018年第13期16-19,共4页
目的:探讨Sutureless技术治疗新生儿完全性肺静脉异位引流(TAPVC)的护理配合方法。方法:对42例TAPVC新生儿应用Sutureless技术矫治,术前控制缺氧发作,注意温度及皮肤的管理,全程严密观察病情,积极配合医生处理肺动脉高压,熟悉本病解剖... 目的:探讨Sutureless技术治疗新生儿完全性肺静脉异位引流(TAPVC)的护理配合方法。方法:对42例TAPVC新生儿应用Sutureless技术矫治,术前控制缺氧发作,注意温度及皮肤的管理,全程严密观察病情,积极配合医生处理肺动脉高压,熟悉本病解剖特点及手术步骤,充分正确的用物准备,术中密切配合,术后安全转运患儿。结果:42例患儿均顺利完成手术,安返监护室,1例患儿因多脏器功能衰竭,肺动脉高压危象术后死亡。结论:对TAPVC新生儿应用Sutureless技术矫治,在术前对患儿进行综合管理,全程严密观察病情,配合医生处理肺动脉高压,熟悉本病解剖特点及手术步骤,密切配合,灵活应对,是手术顺利完成的重要保障。 展开更多
关键词 新生儿 完全性肺静脉异位引流 sutureless技术 护理配合
暂未订购
Primary sutureless技术在全肺静脉异位引流矫治中应用
4
作者 凌云飞 安琪 《中国循环杂志》 CSCD 北大核心 2018年第S01期64-64,共1页
目的:全肺静脉异位引流(TAPVC)是最常见的先天性心脏病之一,术后肺静脉梗阻(PVO)是发生率高,明显影响TAPVC预后。Sutureless技术是将肺静脉共汇或部分肺静脉与后心包直接吻合的一种技术,在TAPVC术后PVO治疗中获得良好临床效果。但Suture... 目的:全肺静脉异位引流(TAPVC)是最常见的先天性心脏病之一,术后肺静脉梗阻(PVO)是发生率高,明显影响TAPVC预后。Sutureless技术是将肺静脉共汇或部分肺静脉与后心包直接吻合的一种技术,在TAPVC术后PVO治疗中获得良好临床效果。但Sutureless技术初次应用于TAPVC矫治(Primary sutureless)的效果目前尚有争议。 展开更多
关键词 全肺静脉异位引流 PRIMARY sutureless
暂未订购
Novel sutureless transplantation for primary pterygium associated with cysts 被引量:6
5
作者 Yi Shao, Jing-Lin Yi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第3期280-283,共4页
AIM: To evaluate the efficacy and safety of a novel sutureless AMT (amniotic membrane transplantation) or CAT (conjunctivolimbal autograft transplantation) using fibrin glue for reconstructing corneoconjunctival surfa... AIM: To evaluate the efficacy and safety of a novel sutureless AMT (amniotic membrane transplantation) or CAT (conjunctivolimbal autograft transplantation) using fibrin glue for reconstructing corneoconjunctival surfaces for primary pterygium associated with cysts. METHODS: A prospective descriptive study was made of the period 1 January 2006-1 May 2009. Nine patients with primary pterygium associated with cysts underwent pterygium and cyst excision followed by sutureless AMT or CAT using fibrin glue. RESULTS: During a mean follow-up of 8.00 +/- 0.67 months, all eyes maintained a smooth and stable corneal epithelial surface without recurrent erosion or persistent epithelial defect. The limbal donor site showed the presence of mild depressions without the formation of pseudopterygium. All eyes have good tear secretion function, tear film stability and ocular motility. CONCLUSION: Sutureless transplantation using fibrin glue is safe and effective for restoring a stable corneoconjunctival epithelium in primary pterygium associated with cysts. 展开更多
关键词 sutureless PTERYGIUM CYST AMT CAT
原文传递
Combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification for rhegmatogenous retinal detachment repair 被引量:2
6
作者 Hoseok Moon Hee Jin Sohn +2 位作者 Dea Yeong Lee Jong Yeon Lee Dong Heun Nam 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第1期122-127,共6页
AIM: To assess the outcomes of combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification with intraocular lens implantation for rhegmatogenous retinal detachment(RRD) repair.METHODS: This was a ret... AIM: To assess the outcomes of combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification with intraocular lens implantation for rhegmatogenous retinal detachment(RRD) repair.METHODS: This was a retrospective, consecutive,noncomparative, interventional case series of 30 eyes of30 patients who underwent combined sutureless vitrectomy and clear corneal cataract surgery for the repair of RRD. The principal outcome measures were primary anatomical success rate, reasons for redetachment, final visual acuity, and surgical complications.RESULTS: Primary reattachment was achieved in 27eyes(90.0%). The reasons for redetachment(3 eyes, 10%)were incomplete laser retinopexy, persistent chronic subretinal fluid, and proliferative vitreoretinopathy,respectively. The logarithm of the minimum angle of resolution visual acuity(mean±SD) improved from 0.76±0.74 preoperatively to 0. 21 ± 0. 37 6 months’ postoperatively(P 【0.0001). Postoperative hypotony was not detected,but 1 eye( 3. 3 %) had increased intraocular pressure(30 mm Hg) with spontaneous resolution. No endophthalmitis developed during follow-up. Macular pucker was detected in 3 eyes(10.0%).· CONCLUSION: Combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification with intraocular lens implantation for RRD repair was proven safe and effective. It may provide not only the known advantages of conventional combined surgery, but also additional advantages such as less conjunctival fibrosis and the maintenance of stable intraocular pressure with low risks of postoperative hypotony and intraocular pressure elevation. 展开更多
关键词 clear corneal phacoemulsification combined 23-guage sutureless vitrectomy rhegmatogenous retinal detachment
原文传递
Evaluation of functional outcome and stability of sutureless scleral tunnel fixated IOLs in children with ectopia lentis 被引量:2
7
作者 Anju Rastogi Prateek Kumar +3 位作者 Shweta Dhiman Manisha Mishra Kamlesh AnAND Ankita Bhardwaj 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第1期66-70,共5页
AIM:To evaluate functional outcome of sutureless scleral tunnel intraocular lens(SSTIOL)in children with crystalline lens subluxation of more than 7 clock hours.METHODS:A prospective interventional study was conducted... AIM:To evaluate functional outcome of sutureless scleral tunnel intraocular lens(SSTIOL)in children with crystalline lens subluxation of more than 7 clock hours.METHODS:A prospective interventional study was conducted consisting of 45 eyes of 44 children in age group 6-18 y having>7 clock hours of lens subluxation who underwent lensectomy-vitrectomy followed by SSTIOL implantation.Primary outcome was improvement in best corrected visual acuity(BCVA)and secondary outcomes were assessment of intraocular lens(IOL)tilt using ultrasound biomicroscopy(UBM),mean change in astigmatism at last follow-up of 1 y and associated complications.RESULTS:The mean preoperative and postoperative BCVA was 1.05±0.28 and 0.64±0.45(log MAR)respectively(P=0.001)at last follow-up.The mean astigmatism preoperatively and postoperatively was-4.17±2.69 D and-1.86±1.25 D respectively(P=0.011).Significant IOL tilt(>5 degrees)was present in 5 cases.The mean percentage endothelial loss was 3.65%±1.92%.The most serious complication encountered was retinal detachment seen in 2 cases.CONCLUSION:SSTIOL implantation provides efficient visual rehabilitation in children provided there is stringent case selection.We recommend caution in children having white-to-white distance>12 mm and presence of peripheral retinal degenerations. 展开更多
关键词 ectopia lentis subluxated lens sutureless scleral tunnel fixated intraocular lens
原文传递
Pupillary capture following sutureless scleral-fixated intraocular lens in children with Marfan syndrome 被引量:1
8
作者 Dong-Mei Qi Shu-Jia Huo Tao Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1789-1793,共5页
AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxat... AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxation due to MFS.These children underwent lensectomy,anterior vitrectomy,and sutureless SFIOL.According to the position of placement of intraocular lens(IOL)haptics,two study groups were reviewed for best corrected visual acuity(BCVA)and postoperative complications:group A,14 eyes with haptics fixated at 2.0 mm from the limbus;group B,12 eyes with the haptics fixated at 2.5 mm from the limbus.RESULTS:The mean axial length for all patients was 25.66±2.35 mm.Postoperative BCVA in logMAR were significant improved in both groups(0.77±0.32 to 0.17±0.12 in group A,0.66±0.25 to 0.24±0.12 in group B,both P<0.001)while no significant difference between two groups(P>0.05).Pupillary capture was main postoperative complication,occurring between 3d and 18mo.It occurred in 7 eyes in group A and one eye in group B(P=0.02).CONCLUSION:Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS.Pupillary capture is the main postoperative complication.Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture. 展开更多
关键词 Marfan syndrome sutureless scleral-fixated intraocular lens pupillary capture CHILDREN
原文传递
A sutureless subconjunctival M-shaped limbus incision for hard cataracts 被引量:1
9
作者 Ping-Hong Lai Jun Yang +1 位作者 Fang Hang Tlili Zaafouri 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第11期1694-1696,共3页
Dear Editor,Iam Dr.Ping-Hong Lai,from the Jiangxi Eye Center,Jiangxi Provincial People's Hospital,Nanchang,Jiangxi Province,China.I would like to present the technique of subconjunctival M-shaped limbus incision for ... Dear Editor,Iam Dr.Ping-Hong Lai,from the Jiangxi Eye Center,Jiangxi Provincial People's Hospital,Nanchang,Jiangxi Province,China.I would like to present the technique of subconjunctival M-shaped limbus incision for a series of cases with hard cataracts. 展开更多
关键词 Figure A sutureless subconjunctival M-shaped limbus incision for hard cataracts
原文传递
Sutureless amniotic membrane transplantation following excision of ocular surface neoplasia 被引量:1
10
作者 Altan Ozcan Ebru Esen Emine Ciloglu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期637-640,共4页
【正】Dear Sir,S uccess of surgical management of conjunctival neoplasias primarily depends on the complete excision of the mass and eradication of tumor cells from the ocular surface[1-3].Especially in cases that ext... 【正】Dear Sir,S uccess of surgical management of conjunctival neoplasias primarily depends on the complete excision of the mass and eradication of tumor cells from the ocular surface[1-3].Especially in cases that extensive resections are required,primary closure may not be feasible;so ocular surface reconstruction can be a challenging problem for the surgeons.For conjunctival tissue defects different surgical 展开更多
关键词 sutureless amniotic membrane transplantation following excision of ocular surface neoplasia AMT
原文传递
Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis
11
作者 Huan Liu Shijiang Zhang +5 位作者 Yongfeng Shao Xiaohu Lu Weidong Gu Buqing Ni Qun Gu Junjie Du 《The Journal of Biomedical Research》 CAS CSCD 2018年第6期454-460,共7页
The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we... The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we developed a novel device for sutureless aortic anastomosis. A series of experiments were carried out for tensile and leakproofcapacity assessments to verify the feasibility of the ring connector by using fresh swine aorta samples. In in vivo test,the ring connector was implanted in 6 swine with follow-up of 6 months. Radiographic and pathological studies of the aorta were performed. In the tensile tests, the strength was 32.7±5.9 Newton(N) in the sutureless anastomosis group,compared with 73.3±12.5 N in the control group by traditional manual suture. In the leakproof-capacity assessment,no sign of either leakage or bursting was evident at 280 mmHg of internal pressure in the aorta samples. In in vivo tests,it took 9.47±0.3 minutes for the sutureless anastomosis, compared with 15.58± 1.39 minutes for hand-sewn suturing. Insertion was easy and rapid. Radiographic and pathological studies were performed at first month, third month and sixth month after surgery, each time obtained from the two swine, showed patency of the anastomosis and no signs of stenosis, blood leakage, migration or pseudoaneurysm formation, except one paralyzed swine developed of thrombo-occlusion at the site of the sutureless anastomosis. The result indicates that this novel ring connector offers considerable promise for sutureless aortic anastomosis. 展开更多
关键词 aortic diseases sutureless device aortic anastomosis SWINE
暂未订购
A sutureless technique for securing leaking sclerotomies with viscoelastic substances in 23-gauge microincision vitrectomy surgery
12
作者 Meng Li Quan-Yong Yi +4 位作者 Jing-Hai Mao Yan-Hong Liao Yan-Yan Wang Qin-Kang Lu Yan Gong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期730-735,共6页
AIM:To introduce and evaluate the clinical efficacy of a new technique,the use of viscoelastic substances(VS)to close leaking sclerotomy in 23G microincision vitrectomy,and to observe its effect on the visual acuity a... AIM:To introduce and evaluate the clinical efficacy of a new technique,the use of viscoelastic substances(VS)to close leaking sclerotomy in 23G microincision vitrectomy,and to observe its effect on the visual acuity and intraocular pressure(IOP)of patients.METHODS:Patients who underwent 23G vitrectomy in Ningbo Eye Hospital before the use of VS technique(June 2019 to September 2020)and after the use of VS technique(October 2020 to December 2021)were selected as the subjects of this study.The above cases underwent operation by the same surgeon and were retrospectively analyzed.VS technique was used as the alternative to suturing,in which a small amount of VS was injected at the leaking sclerotomy and then gently massaged to confirm leaking sclerotomy closure.RESULTS:A total of 174 eyes were covered in the study,including 84 eyes in the control group(before the use of VS technique)and 90 eyes in the VS technique group.The number of eyes that needed to be sutured decreased considerably from 42.9%in the control group to 3.3%in the VS technique group,and the proportion of subconjunctival hemorrhage at 1-2d after surgery decreased remarkably from 35.7%in the control group to 2.2%in the VS technique group.No substantial differences in the incidence of mean IOP and low IOP were found between 1-2 and 3-20d after surgery in the VS technique group.No major complications associated with VS technique were identified during the study.CONCLUSION:In 23G microincision vitrectomy,VS technique is a safe,simple,and effective method to close leaking sclerotomy. 展开更多
关键词 vitrectomy surgery leaking sclerotomy 23-gauge sutureless technique viscoelastic substances intraocular pressure
原文传递
Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses
13
作者 Paolo Berretta Marco Di Eusanio 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第6期504-510,共7页
Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved des... Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved despite increasing age of patients and increasing bur- den of comorbidities. However, despite such excellent results and its well-established position, conventional AVR has undergone great de- velopment over the previous two decades. Such progress, by way of less irtvasive incisions and use of new technologies, including tran- scatheter aortic valve implantation and sutureless valve prostheses, is intended to reduce the traumatic impact of the surgical procedure, thus fulfilling lower risk patients' expectations on the one hand, and extending the operability toward increasingly high-risk patients on the other. Sutureless and rapid deployment aortic valves are biological, pericardial prostheses that anchor within the aortic annulus with no more than three sutures. The sutureless prostheses, by avoiding the passage and the tying of the sutures, significantly reduce operative times and may improve outcomes. However, there is still a paucity of robust, evidence-based data on the role and performance of sutureless AVR. Therefore, strongest long-term data, randomized studies and registry data are required to adequately assess the durability and long-term outcomes of sutureless aortic valve replacement. 展开更多
关键词 Aortic valve replacement Minimally invasive Rapid deployment prosthesis sutureless valve
在线阅读 下载PDF
Off-Pump Multilayered Sutureless Repair for a Left Ventricular Blowout Rupture after Aortic Dissection Repair
14
作者 Susumu Isoda Tamizo Kimura +6 位作者 Katsunori Tanaka Kenji Nishimura Nozomu Yamanaka Shin-ichi Taguchi Keiji Uchida Norihisa Karube Kiyotaka Imoto 《Open Journal of Thoracic Surgery》 2015年第1期10-14,共5页
A left ventricular (LV) free wall rupture is a highly lethal condition. A 75-year-old female who experienced chest pain was diagnosed as having an acute aortic dissection Stanford type A and underwent emergent surgery... A left ventricular (LV) free wall rupture is a highly lethal condition. A 75-year-old female who experienced chest pain was diagnosed as having an acute aortic dissection Stanford type A and underwent emergent surgery. Under cardiopulmonary bypass with LV venting through the right superior pulmonary vein, a proximal aortic stamp was formed. The patient was cooled, selective antegrade brain perfusion was performed, and a hemiarch repair was performed. After the patient was transferred to the intensive care unit, her blood pressure suddenly fell to 50 mmHg. She had a blowout rupture in the left ventricular anterolateral free wall. Since the bleeding hall was not large and the damage to the surrounding left ventricular tissue was not very wide, an off-pump multilayered sutureless repair was performed by using three layers of collagen fleece squares with fibrinogen-based impregnation (TachoComb;CSL Behring, Tokyo, Japan) and three layers of gelatin-resorcin-formalin glue reinforced by an equine pericardial patch (Xenomedica;Edwards Lifesciences, LLC, Irvine, CA). The blow-out rupture seemed to be caused by perioperative myocardial infarction generated by the compression of the left ventricular vent to the LV lateral wall. The patient was free from re-rupture or aneurysm enlargement. The thickness of the hemostatic material seemed to help control the bulging of the aneurysm and to prevent further LV aneurysm enlargement and re-rupture. 展开更多
关键词 BLOWOUT Cardiac RUPTURE sutureless REPAIR Aortic Dissection TachoComb
暂未订购
Clinical Observation of 126 Cases of Sutureless Phacoemulsification with PMMA Intraocular Lens Implantation
15
作者 Yanshuang Yan, Zhengxing MaoNo. 422 Hospital of the People’s Liberation Army, Zhanjiang 524005, China 《眼科学报》 2000年第3期181-183,共3页
关键词 晶状体乳化剂 眼内透镜 PMMA
暂未订购
初次手术应用sutureless技术治疗婴幼儿完全性肺静脉异位引流的效果 被引量:7
16
作者 欧艳秋 丁以群 +5 位作者 刘小清 麦劲壮 温树生 岑坚正 陈寄梅 庄建 《中华胸心血管外科杂志》 CSCD 北大核心 2014年第10期577-581,共5页
目的 回顾性分析初次手术中应用sutureless技术治疗婴幼儿完全性肺静脉异位引流(TAPVC)的早、中期效果.方法 2007年7月1日至2012年12月31日,126例行外科矫治术的心上型、心下型和混合型TAPVC患儿(婴)入选,其中sutureless手术方式组5... 目的 回顾性分析初次手术中应用sutureless技术治疗婴幼儿完全性肺静脉异位引流(TAPVC)的早、中期效果.方法 2007年7月1日至2012年12月31日,126例行外科矫治术的心上型、心下型和混合型TAPVC患儿(婴)入选,其中sutureless手术方式组54例,传统手术方式组72例,收集术前术后临床资料并随访至2013年4月.结果 Sutureless技术组的体外循环时间和主动脉阻断时间均低于传统手术组(分别为Z=1 296.000、P=0.001和Z=1 181.500、P=0.000).Sutureless技术组和传统手术组相比,院内死亡比例差异无统计学意义(3.7%对11.1%,x2 =1.414,P=0.234),术后总死亡比例低(5.6%对23.6%,x2=7.533,P=0.006),术后肺静脉梗阻发生率低(1.9%对16.7%,x2=7.319,P=0.007).校正术前肺静脉狭窄、混合型、新生儿以及体质量等因素后,术后死亡与传统手术方式(HR =4.53,95%置信区间1.31~ 15.72,P=0.017)和术后肺静脉梗阻的发生(HR=10.42,95%置信区间1.32~ 82.02,P=0.026)显著相关.结论 对于心上型、心下型及昆合型TAPVC患儿,初次矫治手术采用sutureless技术可以明显缩短体外循环和主动脉阻断时间,降低术后死亡比例和肺静脉梗阻发生率. 展开更多
关键词 心脏缺损 先天性 心脏外科手术 完全性肺静脉异位引流 sutureless技术
原文传递
免缝合手术切除与CO_(2)激光治疗仪治疗鸡眼的疗效分析
17
作者 路来社 鲁滨 鲁建民 《西安文理学院学报(自然科学版)》 2025年第1期63-66,共4页
本研究旨在比较分析免缝合手术切除和CO_(2)激光治疗仪治疗鸡眼的疗效,为临床治疗提供科学依据.选取2017年9月—2022年9月西安文理学院校医院120例鸡眼患者,随机分为CO_(2)激光治疗仪组和免缝合手术切除组,比较手术时间、术中出血量、... 本研究旨在比较分析免缝合手术切除和CO_(2)激光治疗仪治疗鸡眼的疗效,为临床治疗提供科学依据.选取2017年9月—2022年9月西安文理学院校医院120例鸡眼患者,随机分为CO_(2)激光治疗仪组和免缝合手术切除组,比较手术时间、术中出血量、伤口愈合时间以及半年复发率.经统计分析,两组差异均具有统计学意义(P<0.05),免缝合手术组虽然手术时间较长,术中出血量较多,但伤口愈合时间更短,半年复发率更低.本研究显示免缝合手术切除恢复快、复发率低,疗效好,为优先治疗选择. 展开更多
关键词 鸡眼 免缝合 手术切除
暂未订购
自创免缝合固定法在恶性肿瘤病人锁骨下深静脉置管中应用的回顾性研究
18
作者 王丹菊 王同彪 +1 位作者 吕阗 余婷婷 《循证护理》 2025年第12期2483-2487,共5页
目的:回顾性分析免缝合固定法在恶性肿瘤病人锁骨下深静脉置管的效率、经济效益与安全性。方法:采用回顾性分析方法筛选广西中医药大学第一附属医院信息系统中2022年9月—2023年9月在肿瘤科及肝病科住院接受锁骨下穿刺置管的恶性肿瘤病... 目的:回顾性分析免缝合固定法在恶性肿瘤病人锁骨下深静脉置管的效率、经济效益与安全性。方法:采用回顾性分析方法筛选广西中医药大学第一附属医院信息系统中2022年9月—2023年9月在肿瘤科及肝病科住院接受锁骨下穿刺置管的恶性肿瘤病人为研究对象,根据导管固定是否采用缝线分为免缝合固定组(121例)和缝合固定组(98例),按性别、年龄、体质指数、凝血酶原时间、出汗、病程、合并症进行1∶1匹配,最终纳入免缝合固定组和缝合固定组各71例。对比两组病人置管的效率、经济效益及安全性,并分析不良反应发生的影响因素。结果:与缝合固定组相比,免缝合固定组穿刺置管总时长及拔管时长明显缩短,换药次数、利多卡因使用量、麻醉扎针+缝针数、置管相关护理费用明显减少,且导管相关性感染、总不良反应率明显下降(P<0.05)。Logistic回归分析结果显示,病程、出汗、合并糖尿病、是否采用免缝合固定是其发生不良反应的影响因素(P<0.05)。结论:相较于缝合固定,免缝合固定在锁骨下深静脉置管术中可以明显缩短手术和拔管时长,减少麻醉扎针+缝针数、利多卡因使用量、换药次数,提高置管效率,节省置管相关护理费用,并降低导管相关性感染率及总不良反应发生率。 展开更多
关键词 免缝合固定 缝合固定 锁骨下深静脉置管 回顾性研究 影响因素
暂未订购
Sutureless手术与传统手术治疗完全性肺静脉异位引流疗效的Meta分析 被引量:15
19
作者 吴雨昊 辛良靖 +4 位作者 金鑫 李勇刚 况虹宇 吴春 周悦航 《中华小儿外科杂志》 CSCD 北大核心 2019年第1期15-22,共8页
目的采用Meta分析的方法评价sutureless手术与传统手术治疗完全性肺静脉异位引流(TAPVC)的疗效。方法计算机检索PubMed、EMbase、Medline、Cochrane Library、维普、万方、CNKI相关文献。根据纳入标准查找有关对比sutureless手术与传统... 目的采用Meta分析的方法评价sutureless手术与传统手术治疗完全性肺静脉异位引流(TAPVC)的疗效。方法计算机检索PubMed、EMbase、Medline、Cochrane Library、维普、万方、CNKI相关文献。根据纳入标准查找有关对比sutureless手术与传统手术治疗完全性肺静脉异位引流疗效的文献。由2名评价者独立选择研究、提取数据和评估方法学质量后,采用Revman5.3软件对文献数据进行效应量合成。采用Stata12.0软件对纳入的文献针对发表偏倚行Begg’s及Egger’s检验。结果最终共纳入7项研究,共纳入病例1293例。Sutureless手术治疗在以下方面优于传统手术,其差异有统计学意义:术后肺静脉梗阻发生率(OR,0.52;95%CI,0.32,0.86;P=0.01)、因肺静脉梗阻再手术率(OR,0.28;95%CI,0.09,0.87;P=0.03)。住院时间(WMD,5.92;95%CI,-7.97,19.80;P=0.40)和术后死亡率(OR,0.65;95%CI,0.41,1.04;P=0.07)两种治疗方式相比差异无统计学意义。体外循环和主动脉钳闭时间(WMD,5.07;95%CI,-9.29,19.42;P=0.49);(WMD,5.73;95%CI,-7.76,19.23;P=0.40)两种治疗方式相比,差异也无统计学意义,但是敏感性分析结果提示这一结论可能不稳健。关于术后死亡率的漏斗图、Begg’s及Egger’s检验均未发现发表偏倚(Begg’s检验P=0.88,Egger’s检验P=0.248)。结论与传统手术相比,sutureless手术治疗完全性肺静脉异位引流的术后肺静脉梗阻发生率、因肺静脉梗阻再手术率更低,住院时间、术后病死率、体外循环和主动脉钳闭时间两种治疗方式相比,差异无统计学意义。关于体外循环和主动脉钳闭时间的结论可能不稳健。由于本文为基于回顾性研究的Meta分析,因此证据等级较低,为进一步证实sutureless手术在TAPVC治疗中的优越性还需大样本的随机对照研究以证实。 展开更多
关键词 心脏病 肺静脉异位引流 sutureless手术 META分析
原文传递
无缝线后房型人工晶状体巩膜固定术临床应用的研究进展
20
作者 郝宗龙 聂黎黎 裴颖 《吉林大学学报(医学版)》 北大核心 2025年第2期549-556,共8页
无缝线后房型人工晶状体巩膜固定术(SSF-PCIOL)是一种主要用于在缺乏足够晶状体囊膜支撑的情况下实施人工晶状体(IOL)植入固定的技术,就临床效果而言,SSF-PCIOL具有可以提高患者视觉质量和增强IOL稳定性的优势,其术式包括经玻璃体入路... 无缝线后房型人工晶状体巩膜固定术(SSF-PCIOL)是一种主要用于在缺乏足够晶状体囊膜支撑的情况下实施人工晶状体(IOL)植入固定的技术,就临床效果而言,SSF-PCIOL具有可以提高患者视觉质量和增强IOL稳定性的优势,其术式包括经玻璃体入路型、巩膜瓣纤维蛋白胶辅助型和经结膜入路型,可供临床选用的IOL类型也从传统的三片式向专门设计用于巩膜固定的新型IOL发展。在临床实践中,SSF-PCIOL可与其他眼科手术联合开展,并应用先进的辅助设备,在减少患者手术创伤和保障手术效果的前提下,提升手术操作的精准性与效果评估的客观性。现就SSF-PCIOL的术式发展历程、IOL类型特点、IOL联合手术和辅助设备的协同应用以及临床效果的全面评估等方面进行综述,以期为该术式的进一步改进提供临床依据,并为无晶状体囊膜支撑的患者提供手术选择参考。 展开更多
关键词 无缝线 后房型 巩膜固定 无晶状体 人工晶状体
暂未订购
上一页 1 2 10 下一页 到第
使用帮助 返回顶部