期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
可重构宽带功率放大器设计 被引量:2
1
作者 南敬昌 戴涛 +3 位作者 丛密芳 刘超 南星伊 任建伟 《电子测量与仪器学报》 CSCD 北大核心 2023年第9期25-32,共8页
随着未来无线通信需求的增长,通信系统需适用更多的频带和标准。针对可重构功率放大器各模式下工作带宽窄的缺点,本文基于简化实频技术和可重构理论,提出了一种拓展可重构功率放大器工作带宽的设计方法。通过在可重构理论中融入简化实... 随着未来无线通信需求的增长,通信系统需适用更多的频带和标准。针对可重构功率放大器各模式下工作带宽窄的缺点,本文基于简化实频技术和可重构理论,提出了一种拓展可重构功率放大器工作带宽的设计方法。通过在可重构理论中融入简化实频法的宽带设计方法,在设计过程中加入新的误差函数,对可变模式下的可重构电路结构进行判别,进而实现可重构宽带功率放大器设计。为了验证该方法的有效性,并满足实际设计指标,采用中国科学院微电子研究所自主研发的LDMOS晶体管设计并制作了适用于GSM网络和LTE网络的一个频率可切换的宽频可重构功率放大器。测试结果表明,该可重构功率放大器在不同模式下可分别工作在0.6~1.1 GHz和1.1~1.6 GHz频段,饱和输出功率超过40 dBm,漏极效率(DE)在50%~60%之间。因此,本文提出的设计方法可以降低可重构宽带功率放大器的设计难度,较好的发挥晶体管性能,降低成本,在实际基站射频电路设计中具有很好的应用意义。 展开更多
关键词 可重构 宽带 简化实频法 误差函数 功率放大器
原文传递
Modified Single Phase SRF d-q Theory Based Controller for DVR Mitigating Voltage Sag in Case of Nonlinear Load
2
作者 Dhiraj N. Katole Manoj B. Daigavane +1 位作者 Snehal P. Gawande Prema M. Daigavane 《Journal of Electromagnetic Analysis and Applications》 2017年第2期22-33,共12页
This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag partic... This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag particularly for nonlinear load. In case of single phase distribution line with nonlinear load, the complexity of controller’s design becomes more serious issue. The present single phase and/or three phase theories applicable to DVR shows poor response to restore voltage sag in case of nonlinear load due to presence of harmonics. Hence restoration of voltage sag in single phase nonlinear load connected system has been a serious concern. Therefore, new controller for DVR has been proposed incorporating effective design concept for fundamental component extraction in case of nonlinear load. The single phase SRFT based main controller for DVR works on two separate closed path viz. feed forward path for quick transient response and feedback path for reducing the steady state error. Moreover, pre-sag mitigation strategy of DVR has been adapted through these two aforementioned paths. Complete design of proposed controller is based on phasor analysis. It also consist of proportional integral (PI) controller to reduce the error in the DC-link voltage during compensation time. The controller performance has been verified in MATLAB Simulink for both types (linear and nonlinear) of load. The results obtained indicates that the proposed controller is effective in its performance. 展开更多
关键词 Power Quality Voltage SAG DVR Single Phase srft BASED CONTROLLER Sinusoidal Pulse WIDTH Modulation Non-Linear Load
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部