The parallel spectral-domain optical coherence tomography(PSDOCT) is described for highspeed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC...The parallel spectral-domain optical coherence tomography(PSDOCT) is described for highspeed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional QCT and complex Fourier-domain optical coherence to- mography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.展开更多
Dear Editor,Multiple evanescent white dot syndrome (MEWDS) was first described in 1984 as a rare, acute, unilateral,multifocal retinochoroidal disorder, typically affecting young myopic women. Previous studies with ...Dear Editor,Multiple evanescent white dot syndrome (MEWDS) was first described in 1984 as a rare, acute, unilateral,multifocal retinochoroidal disorder, typically affecting young myopic women. Previous studies with fluorescein angiography (FA) and electrophysiology suggested that MEWDS to be a disease in the retinal pigment epithelium (RPE) or outer retina, while recent studies with spectral- domain optical coherence tomography (SD-OCT) suggested it may be an outer retinal disease due to observation of hyperreflective material in outer retina and subtle disruptionsof the ellipsoid zone without RPE disruption.展开更多
The equations of electrodynamics for a gyrotropic medium by using Maxwell’s equa-tions are deduced.Through Fourier transformation,the admittances of TM and TE modes inthe electrically gyrotropic substrate and magneti...The equations of electrodynamics for a gyrotropic medium by using Maxwell’s equa-tions are deduced.Through Fourier transformation,the admittances of TM and TE modes inthe electrically gyrotropic substrate and magnetically gyrotropic substrate are given.Numericalresults of the dominant mode in magnetized ferrite-loaded double-layered finlines are presentedwhich could be used in designing finline ferrite devices.展开更多
The rapid growth of IP traffic has contributed to wide deployment of optical devices in elastic optical network.However,the passband shape of wavelength selective switches(WSSs)that are used in reconfigurable optical ...The rapid growth of IP traffic has contributed to wide deployment of optical devices in elastic optical network.However,the passband shape of wavelength selective switches(WSSs)that are used in reconfigurable optical add-drop multiplexer(ROADM)/optical cross connect(OXC)is not ideal,causing the narrowing of spectrum.Spectral narrowing will lead to signal impairment.Therefore,guard-bands need to be inserted between adjacent paths which will cause the waste of resources.In this paper,we propose a service-based intelligent aggregation node selection and area division(ANS-AD)algorithm.For the rationality of the aggregation node selection,the ANS-AD algorithm chooses the aggregation nodes according to historical traffic information based on big data analysis.Then the ANS-AD algorithm divides the topology into areas according to the result of the aggregation node selection.Based on the ANS-AD algorithm,we propose a time-domain and spectral-domain flow aggregation(TS-FA)algorithm.For the purpose of reducing resources'waste,the TS-FA algorithm attempts to reduce the insertion of guard-bands by time-domain and spectral-domain flow aggregation.Moreover,we design a time-domain and spectral-domain flow aggregation module on software defined optical network(SDON)architecture.Finally,a simulation is designed to evaluate the performance of the proposed algorithms and the results show that our proposed algorithms can effectively reduce the resource waste.展开更多
AIM: To compare central macular thickness (CMT) measurements obtained by two spectral-domain optical coherence tomography (SD-OCT) exams, and to evaluate measurement reproducibility and agreement between these two exa...AIM: To compare central macular thickness (CMT) measurements obtained by two spectral-domain optical coherence tomography (SD-OCT) exams, and to evaluate measurement reproducibility and agreement between these two exams, and to investigate the relationship between CMT and possible influencing factors such as age, sex, eye (OD/OS), and operators in elderly non-mydriatic eyes. METHODS: Seventy-two normal subjects were included. Every subject underwent CMT measurement twice using one of two SD-OCT (OSE-2000, Moptim, Shenzhen, China & 3-D OCT-1000, Topcon, Tokyo, Japan) instruments respectively where we randomly chose one eye in each patient for the test; these exams were performed by two operators over an hour period with a brief rest between sessions. Comparison of the OSE-2000 and 3-D OCT-1000 CMT measurements was based on paired- t test The mean difference between the CMT measurements was calculated. General linear model analyzed the relationships among eye (OD/OS), operator, sex, and CMT values using age as co-variant. All tests were considered statistically significant at P <0.05. The main outcome measures included CMT. RESULTS: When evaluated with general linear model analysis, CMT measurements were found to have high reproducibility across the two instruments between the two operators for the OSE-2000 single line scan and 3-D OCT-1000 macular scans (P=0.731; P=0.443). There was statistically significant difference in CMT values between the two instruments (P<0.001) and the mean difference was -46.83 mu m at 95% confidence limits (-49.15,-44.51). Age was positively correlated with CMT (beta coefficient =0.516, P=0.001; beta coefficient=0.453, P =0.009) and sex was correlated with CMT from the OSE-2000 (P=0.021) but not with the 3-D OCT-1000 (P=0.056). According to the actual thickness measurements, the CMT of the male was thicker than the female's but there was no statistical difference. There was interaction between sex and eye in OSE-2000 and not in 3-D OCT-1000 (P=0.02; P =0.374). No significant correlation was found between CMT and the influencing factor of eye in both of the instruments (P=0.884; P=0.492). CONCLUSION: Reproducibility of CMT measurement using the two SD-OCTs is excellent in normal eyes according to the operator factor analysis. OSE-2000 has a different posterior retinal boundary of CMT measurement, which results in the CMT value differences, compared with the 3-D OCT-1000. Age is positively correlated with CMT measurement while sex is correlated with CMT in the OSE-2000 but not in the 3-D OCT-1000 and eye (OD/OS) had no correlation with CMT values. Mydriatic drops may not be necessary for CMT measurement using high scan rate SD-OCT in normal eyes in dark room.展开更多
Optical Coherence Tomography (OCT) technique is a nondestructive optical detection technology based on low-coherence interferometer and it has become an attractive cultural heritage research method. A 1310 nm source s...Optical Coherence Tomography (OCT) technique is a nondestructive optical detection technology based on low-coherence interferometer and it has become an attractive cultural heritage research method. A 1310 nm source spectral-domain optical coherence tomography (SD-OCT) system based on optical fiber Michelson interferometer and optical spectrum analyzer is proposed and demonstrated for Chinese cultural heritage research. The cross-section OCT images of Chinese pigment samples and jadeite samples can provide a lot of valuable microstructure information for the Chinese cultural heritage research and identification works.展开更多
Objective:The study aimed to report the distinctive fundus appearance of bilateral asymmetric choroidal melanocytosis and reviewed the clinical and multimodal imaging characteristics to differentiate choroidal melanoc...Objective:The study aimed to report the distinctive fundus appearance of bilateral asymmetric choroidal melanocytosis and reviewed the clinical and multimodal imaging characteristics to differentiate choroidal melanocytosis from malignant pigmented retinal lesions.Methods:An observational case report and literature review.Results:A 60-year-old patient underwent comprehensive ophthalmologic examinations.Underfunduscopic examination,bilateral choroidal melanocytosis with asymmetry choroidal pigmentation change was observed.In the right eye,there was diffuse darker coloration extending from posterior pole to the mid-peripheral retina.In the left eye,flat patches of choroidal hyperpigmentation were present,involving superior and inferior hemisphere region,while other regions were depigmented.Spectral-domain optical coherence tomography revealed that the layers of retina and choroid were basically normal,with no elevation of the retinal pigment epithelium.Near infrared reflectance images provided a clearer view of mottled focal hyperpigmentation area,which corresponded to the choroidal hyperpigmentation.Conclusions:This case highlights the effectiveness of multimodal imaging in distinguishing choroidal melanocytosis from malignant entities.It emphasizes the crucial role of multimodal imaging in guiding clinical management to prevent vision-threatening complications and monitor potential malignant transformation.展开更多
文摘The parallel spectral-domain optical coherence tomography(PSDOCT) is described for highspeed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional QCT and complex Fourier-domain optical coherence to- mography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.
文摘Dear Editor,Multiple evanescent white dot syndrome (MEWDS) was first described in 1984 as a rare, acute, unilateral,multifocal retinochoroidal disorder, typically affecting young myopic women. Previous studies with fluorescein angiography (FA) and electrophysiology suggested that MEWDS to be a disease in the retinal pigment epithelium (RPE) or outer retina, while recent studies with spectral- domain optical coherence tomography (SD-OCT) suggested it may be an outer retinal disease due to observation of hyperreflective material in outer retina and subtle disruptionsof the ellipsoid zone without RPE disruption.
文摘The equations of electrodynamics for a gyrotropic medium by using Maxwell’s equa-tions are deduced.Through Fourier transformation,the admittances of TM and TE modes inthe electrically gyrotropic substrate and magnetically gyrotropic substrate are given.Numericalresults of the dominant mode in magnetized ferrite-loaded double-layered finlines are presentedwhich could be used in designing finline ferrite devices.
基金funded by ZTE Industry-Academia-Research Cooperation Funds under Grant No.2017110031005226
文摘The rapid growth of IP traffic has contributed to wide deployment of optical devices in elastic optical network.However,the passband shape of wavelength selective switches(WSSs)that are used in reconfigurable optical add-drop multiplexer(ROADM)/optical cross connect(OXC)is not ideal,causing the narrowing of spectrum.Spectral narrowing will lead to signal impairment.Therefore,guard-bands need to be inserted between adjacent paths which will cause the waste of resources.In this paper,we propose a service-based intelligent aggregation node selection and area division(ANS-AD)algorithm.For the rationality of the aggregation node selection,the ANS-AD algorithm chooses the aggregation nodes according to historical traffic information based on big data analysis.Then the ANS-AD algorithm divides the topology into areas according to the result of the aggregation node selection.Based on the ANS-AD algorithm,we propose a time-domain and spectral-domain flow aggregation(TS-FA)algorithm.For the purpose of reducing resources'waste,the TS-FA algorithm attempts to reduce the insertion of guard-bands by time-domain and spectral-domain flow aggregation.Moreover,we design a time-domain and spectral-domain flow aggregation module on software defined optical network(SDON)architecture.Finally,a simulation is designed to evaluate the performance of the proposed algorithms and the results show that our proposed algorithms can effectively reduce the resource waste.
文摘AIM: To compare central macular thickness (CMT) measurements obtained by two spectral-domain optical coherence tomography (SD-OCT) exams, and to evaluate measurement reproducibility and agreement between these two exams, and to investigate the relationship between CMT and possible influencing factors such as age, sex, eye (OD/OS), and operators in elderly non-mydriatic eyes. METHODS: Seventy-two normal subjects were included. Every subject underwent CMT measurement twice using one of two SD-OCT (OSE-2000, Moptim, Shenzhen, China & 3-D OCT-1000, Topcon, Tokyo, Japan) instruments respectively where we randomly chose one eye in each patient for the test; these exams were performed by two operators over an hour period with a brief rest between sessions. Comparison of the OSE-2000 and 3-D OCT-1000 CMT measurements was based on paired- t test The mean difference between the CMT measurements was calculated. General linear model analyzed the relationships among eye (OD/OS), operator, sex, and CMT values using age as co-variant. All tests were considered statistically significant at P <0.05. The main outcome measures included CMT. RESULTS: When evaluated with general linear model analysis, CMT measurements were found to have high reproducibility across the two instruments between the two operators for the OSE-2000 single line scan and 3-D OCT-1000 macular scans (P=0.731; P=0.443). There was statistically significant difference in CMT values between the two instruments (P<0.001) and the mean difference was -46.83 mu m at 95% confidence limits (-49.15,-44.51). Age was positively correlated with CMT (beta coefficient =0.516, P=0.001; beta coefficient=0.453, P =0.009) and sex was correlated with CMT from the OSE-2000 (P=0.021) but not with the 3-D OCT-1000 (P=0.056). According to the actual thickness measurements, the CMT of the male was thicker than the female's but there was no statistical difference. There was interaction between sex and eye in OSE-2000 and not in 3-D OCT-1000 (P=0.02; P =0.374). No significant correlation was found between CMT and the influencing factor of eye in both of the instruments (P=0.884; P=0.492). CONCLUSION: Reproducibility of CMT measurement using the two SD-OCTs is excellent in normal eyes according to the operator factor analysis. OSE-2000 has a different posterior retinal boundary of CMT measurement, which results in the CMT value differences, compared with the 3-D OCT-1000. Age is positively correlated with CMT measurement while sex is correlated with CMT in the OSE-2000 but not in the 3-D OCT-1000 and eye (OD/OS) had no correlation with CMT values. Mydriatic drops may not be necessary for CMT measurement using high scan rate SD-OCT in normal eyes in dark room.
文摘Optical Coherence Tomography (OCT) technique is a nondestructive optical detection technology based on low-coherence interferometer and it has become an attractive cultural heritage research method. A 1310 nm source spectral-domain optical coherence tomography (SD-OCT) system based on optical fiber Michelson interferometer and optical spectrum analyzer is proposed and demonstrated for Chinese cultural heritage research. The cross-section OCT images of Chinese pigment samples and jadeite samples can provide a lot of valuable microstructure information for the Chinese cultural heritage research and identification works.
基金found by the Key Research and Development Program of the Ministry of Science and Technology(2022YFF1202901)the National Natural Science Foundation of China(82171404)+3 种基金the Natural Science Foundation of Guangdong Province of China(2023A1515011529)the Science and Technology Planning Project of Guangzhou City(2023A03J0181,2024A04J6481)the Fundamental Research Funds for the Central Universities(22yklj04)the Research Start-up Founds of Sun Yat-sen University(Funded Talent[2020]18).
文摘Objective:The study aimed to report the distinctive fundus appearance of bilateral asymmetric choroidal melanocytosis and reviewed the clinical and multimodal imaging characteristics to differentiate choroidal melanocytosis from malignant pigmented retinal lesions.Methods:An observational case report and literature review.Results:A 60-year-old patient underwent comprehensive ophthalmologic examinations.Underfunduscopic examination,bilateral choroidal melanocytosis with asymmetry choroidal pigmentation change was observed.In the right eye,there was diffuse darker coloration extending from posterior pole to the mid-peripheral retina.In the left eye,flat patches of choroidal hyperpigmentation were present,involving superior and inferior hemisphere region,while other regions were depigmented.Spectral-domain optical coherence tomography revealed that the layers of retina and choroid were basically normal,with no elevation of the retinal pigment epithelium.Near infrared reflectance images provided a clearer view of mottled focal hyperpigmentation area,which corresponded to the choroidal hyperpigmentation.Conclusions:This case highlights the effectiveness of multimodal imaging in distinguishing choroidal melanocytosis from malignant entities.It emphasizes the crucial role of multimodal imaging in guiding clinical management to prevent vision-threatening complications and monitor potential malignant transformation.