The modeling ability of a stand-alone version of the Simple Biosphere Model 2(SiB2) was tested mainly through diagnosing the simulated latent heat(LE),sensible heat(H),CO2 flux,and air temperature at the Tongyu ...The modeling ability of a stand-alone version of the Simple Biosphere Model 2(SiB2) was tested mainly through diagnosing the simulated latent heat(LE),sensible heat(H),CO2 flux,and air temperature at the Tongyu field observation station(44°25'N,122°52'E,184 m elevation) of Coordinated Enhanced Observing Period(CEOP),where the land cover is cropland and grassland.In the whole year of 2003,the canopy height and the leaf area index was variable.During non-growth period,the surface would become bare,while during the growth period,the canopy height could reach 2.0 m high over cropland and 0.8 m high over grassland,respectively,and max leaf area index could reach 4.2 and 2.4,respectively.The model was initialized with measurement and driven by half-hourly atmospheric observations.The simulation values for 2003 were compared against measurements.Results show that the model is of a good ability of simulating the hourly latent heat(LE),sensible heat(H),CO2 flux and temperature during the growth period.Moreover,the daily LE,H and CO2 flux simulated by SiB2 could reflect their yearly change reasonably.However,the model may overestimate the H generally.展开更多
SiB2(simple biosphere model Version 2)是用来模拟生态系统通量较为理想的国外模型,为了探讨其在我国黄河灌区的适用性及利用遥感数据驱动模型的可行性,并用其来研究该地区农田能量收支情况,以位山灌区为研究试点,利用位山实验站1a左...SiB2(simple biosphere model Version 2)是用来模拟生态系统通量较为理想的国外模型,为了探讨其在我国黄河灌区的适用性及利用遥感数据驱动模型的可行性,并用其来研究该地区农田能量收支情况,以位山灌区为研究试点,利用位山实验站1a左右的观测数据对模型进行了验证分析,模拟结果表明:SiB2模型能够较好地模拟位山试验站农田的能量通量、CO2通量及地表温度,净辐射、潜热通量、感热通量、CO2通量与地表温度的模拟值与观测值吻合较好,线性相关系数R分别为0.988,0.714,0.607,0.677与0.933,其中净辐射模拟效果最好,感热通量偏差较大。另外,利用遥感MODIS LAI数据驱动SiB2模型表明,除净辐射外,模拟效果很差,因此在站点尺度遥感LAI(叶面积指数,leaf area index)产品不适合驱动SiB2模型。展开更多
Based on previous research on sensible heat flux, we investigate it from different aspects using GAME/Tibet data measured during 6 June–13 September, 1998. This work consists of the derivation of the surface heat flu...Based on previous research on sensible heat flux, we investigate it from different aspects using GAME/Tibet data measured during 6 June–13 September, 1998. This work consists of the derivation of the surface heat flux equation, analysis on counter-gradient heat transference, comparison between two different methods to compute the sensible heat flux, and investigation on the calculation scheme of sensible heat flux in the Simple Biosphere model 2 (SiB2) with relevant simulation. By improving two previous formulations, an integrated formulation for calculating surface heat flux is given. Secondly, using the measured data, the counter-gradient heat flux is clarified, leading to the fact that buoyancy plays an important role in the sensible heat transfer process. It is concluded that (1) energy imbalance is a common phenomenon resulting from the use of the traditional closure scheme on the heterogeneous underlying surface because the measured ensemble heat fluxes by eddy correlation contain the effect of nonlocal parcel movements; and (2) nonlocal parcel movement deserves more attention in any future heat flux study.展开更多
基金supported by the National Basic Research Program of China (2006CB400506)
文摘The modeling ability of a stand-alone version of the Simple Biosphere Model 2(SiB2) was tested mainly through diagnosing the simulated latent heat(LE),sensible heat(H),CO2 flux,and air temperature at the Tongyu field observation station(44°25'N,122°52'E,184 m elevation) of Coordinated Enhanced Observing Period(CEOP),where the land cover is cropland and grassland.In the whole year of 2003,the canopy height and the leaf area index was variable.During non-growth period,the surface would become bare,while during the growth period,the canopy height could reach 2.0 m high over cropland and 0.8 m high over grassland,respectively,and max leaf area index could reach 4.2 and 2.4,respectively.The model was initialized with measurement and driven by half-hourly atmospheric observations.The simulation values for 2003 were compared against measurements.Results show that the model is of a good ability of simulating the hourly latent heat(LE),sensible heat(H),CO2 flux and temperature during the growth period.Moreover,the daily LE,H and CO2 flux simulated by SiB2 could reflect their yearly change reasonably.However,the model may overestimate the H generally.
文摘SiB2(simple biosphere model Version 2)是用来模拟生态系统通量较为理想的国外模型,为了探讨其在我国黄河灌区的适用性及利用遥感数据驱动模型的可行性,并用其来研究该地区农田能量收支情况,以位山灌区为研究试点,利用位山实验站1a左右的观测数据对模型进行了验证分析,模拟结果表明:SiB2模型能够较好地模拟位山试验站农田的能量通量、CO2通量及地表温度,净辐射、潜热通量、感热通量、CO2通量与地表温度的模拟值与观测值吻合较好,线性相关系数R分别为0.988,0.714,0.607,0.677与0.933,其中净辐射模拟效果最好,感热通量偏差较大。另外,利用遥感MODIS LAI数据驱动SiB2模型表明,除净辐射外,模拟效果很差,因此在站点尺度遥感LAI(叶面积指数,leaf area index)产品不适合驱动SiB2模型。
基金mainly by the National Natural Science Foundation ofChina(NSFC)through the project of Regionalization ofAir-land Exchange Parameters over the Tibetan Plateau,the Ministry of Education of China through the Fund ofScientists Abroad,and the Chinese
文摘Based on previous research on sensible heat flux, we investigate it from different aspects using GAME/Tibet data measured during 6 June–13 September, 1998. This work consists of the derivation of the surface heat flux equation, analysis on counter-gradient heat transference, comparison between two different methods to compute the sensible heat flux, and investigation on the calculation scheme of sensible heat flux in the Simple Biosphere model 2 (SiB2) with relevant simulation. By improving two previous formulations, an integrated formulation for calculating surface heat flux is given. Secondly, using the measured data, the counter-gradient heat flux is clarified, leading to the fact that buoyancy plays an important role in the sensible heat transfer process. It is concluded that (1) energy imbalance is a common phenomenon resulting from the use of the traditional closure scheme on the heterogeneous underlying surface because the measured ensemble heat fluxes by eddy correlation contain the effect of nonlocal parcel movements; and (2) nonlocal parcel movement deserves more attention in any future heat flux study.