期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Estimation of the Type of Low Energy Discharge in GIS Adopting Characteristic Gas 被引量:7
1
作者 CHEN Jun LI Li +5 位作者 YAO Weijian TANG Yang ZHENG Xiaoguang YU Jianhui LUO Yunbai ZHOU Wenjun 《Wuhan University Journal of Natural Sciences》 CAS 2011年第4期319-324,共6页
In order to guarantee safe operations, low energy discharge within gas insulated switchgear (GIS) should be detected as soon as possible before they develop severely and cause final breakdown failures. This paper ai... In order to guarantee safe operations, low energy discharge within gas insulated switchgear (GIS) should be detected as soon as possible before they develop severely and cause final breakdown failures. This paper aims to present a GIS discharge diagnosis technique adopting gaseous decompositions. To reach this aim, needle-plate electrode and the sphere-plate electrode with metallic particles on the plate are designed to simulate two kinds of low energy discharge, namely, corona discharge and spark discharge, respectively. After sampling and analyzing the gases, different yields of gaseous by-products under different types of low energy discharge are obtained. Based on the decomposition mechanisms reported by previous researches and the experiment results, it can be concluded that S2OF10, SO2F2 , and SO2 can be used as the characteristic gas to identify low energy discharge; the increment of S2OF10 can indicate the occurrence of low energy discharges while the volume ratio between SO2F2 and SO2 can define the type of low energy discharge. 展开更多
关键词 gas insulated switchgear (GIS) sf6 decomposition low energy discharge DIAGNOSIS
原文传递
单壁碳纳米管气体传感器在GIS局部放电检测中的应用(英文) 被引量:2
2
作者 魏宁 丁卫东 +2 位作者 朱宜东 苏春强 末广纯也 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2700-2706,共7页
This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by ... This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by partial discharge(PD) in GIS tank.The results showed a superior sensitivity,favorable reliability and good reproducibility. For further clarifying the relativity between sensor response and partial discharge activity,the discharge in GIS tank was monitored simultaneously through conventional pulse current method and a SWCNTs gas sensor,and the measurement results were put together for comparative analysis in this paper.The sensor response showed a great dependence on partial discharge characteristics.The sensor response increased nearly linearly with limits when the energy of discharge was persistently accumulated.Partial discharge power had a great influence on the response rate and the time delay.With the increase of partial discharge power,the response rate augmented almost in proportion while the time delay gradually becomes shorter with limits.The results were quite favorable to assess the partial discharge intensity and duration to some extent.Compared with pulse current method,the sensor was predominant to detect partial discharge exposed to constantly high levels of noise.It was capable of detecting partial discharge which was too weak to be detected with pulse current method.However,the sensor response didn't show much dependency on the apparent discharge of partial discharge. 展开更多
关键词 single-walled carbon nanotubes(SWCNTs) gas sensors partial discharge(PD) detection gas insulated switchgear(GIS) tank sf6 decomposition gas PD parameters