The energy equilibrium equation and discrete ordinate methods are combined to establish the one-dimensional steady heat transfer mathematical model of multi-layer thermal insulations (MTIs) in metallic thermal prote...The energy equilibrium equation and discrete ordinate methods are combined to establish the one-dimensional steady heat transfer mathematical model of multi-layer thermal insulations (MTIs) in metallic thermal protection systems. The inverse problem of heat transfer is solved by the genetic algorithm and data from the steady heat transfer experiment of fibrous thermal insulations. The density radiation attenuation coefficient, the albedo of fibrous thermal insulations and the surface emissivity of reflective screens are optimized. Finally, the one-dimensional steady heat transfer model of MTIs with optimized thermal physical parameters is verified by experimental data of the effective MTI conductivity.展开更多
In the present paper, a numerical model combining radiation and conduction for porous materials is developed based on the finite volume method. The model can be used to investigate high-temperature thermal insulations...In the present paper, a numerical model combining radiation and conduction for porous materials is developed based on the finite volume method. The model can be used to investigate high-temperature thermal insulations which are widely used in metallic thermal protection systems on reusable launch vehicles and high-temperature fuel cells. The effective thermal conductivities(ECTs) which are measured experimentally can hardly be used separately to analyze the heat transfer behaviors of conduction and radiation for high-temperature insulation. By fitting the effective thermal conductivities with experimental data, the equivalent radiation transmittance, absorptivity and reflectivity, as well as a linear function to describe the relationship between temperature and conductivity can be estimated by an inverse problems method. The deviation between the calculated and measured effective thermal conductivities is less than 4%. Using the material parameters so obtained for conduction and radiation, the heat transfer process in multilayer thermal insulation(MTI) is calculated and the deviation between the calculated and the measured transient temperatures at a certain depth in the multilayer thermal insulation is less than 6.5%.展开更多
The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighti...The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighting and an improved technique for order of preference by similarity to ideal solution(TOPSIS)method to perform an objective and scientific evaluation of the transformer oil-paper insulation state.Firstly,multiple aging features are extracted from the recovery voltage polarization spectrum and the extended Debye equivalent circuit owing to the limitations of using a single feature for evaluation.A standard evaluation index system is then established by using the collected time-domain dielectric spectrum data.Secondly,this study implements the per-unit value concept to integrate the dimension of the index matrix and calculates the objective weight by using the random forest algorithm.Furthermore,it combines the weighting model to overcome the drawbacks of the single weighting method by using the indicators and considering the subjective experience of experts and the random forest algorithm.Lastly,the enhanced TOPSIS approach is used to determine the insulation quality of an oil-paper transformer.A verification example demonstrates that the evaluation model developed in this study can efficiently and accurately diagnose the insulation status of transformers.Essentially,this study presents a novel approach for the assessment of transformer oil-paper insulation.展开更多
This paper deals with experimental investigations of the electrical and physical properties of oil impregnated insulation paper for power transformers at different temperatures. The ac breakdown voltage, tensile stren...This paper deals with experimental investigations of the electrical and physical properties of oil impregnated insulation paper for power transformers at different temperatures. The ac breakdown voltage, tensile strength and water content of insulation papers impregnated in mineral oil for different time periods were investigated. The effect of insulation paper thickness on the electrical and mechanical properties has also been studied. The results showed that the breakdown voltage and the tensile strength decreased with increasing the time of immersion of insulation paper in oil at room temperature, at 5℃ and at -12℃. Also, the thermal aging effect on the characteristic of insulation paper has been studied. It was found that high temperatures affect the breakdown voltage and the tensile strength to a great extent.展开更多
CF3I has been widely considered as a potential alternative for SF6,because it has low global warming potential(GWP)but an insulation capability that is 1.2 times greater than that of SF6.In this paper,the electron swa...CF3I has been widely considered as a potential alternative for SF6,because it has low global warming potential(GWP)but an insulation capability that is 1.2 times greater than that of SF6.In this paper,the electron swarm parameters of CF3I and its gas mixture with N2,including the effective ionization coefficient and electron drift velocity,are examined theoretically through the Boltzmann equation method in the condition of steady-state Townsend(SST)experiments.Based on the derived data of the limiting field strength of CF3I-N2gas mixture,taking into consideration of environmental aspects such as GWP,ozone depletion potential(ODP),liquefaction temperature and toxicity,we studied the possibility of applying the gas mixture as the insulation medium in gas-insulated switchgears(GIS)or cubic type gas-insulated switchgears(C-GIS).It is found that CF3I-N2gas mixtures contained 30%~70%CF3I perform comprehensively better than pure SF6and compressed N2,and especially in medium and low voltage environments,the boiling point of CF3I-N2gas mixture meets the domestic and global requirements in mid-low latitude regions.Therefore we conclude that the gas mixture is acceptable for replacing SF6as the insulation medium in C-GISs.展开更多
The online-monitoring methods for insulation performance of current transformers of 330-750 kV substation are analyzed and compared.The effectiveness and availability of each method are discussed.Main features,advanta...The online-monitoring methods for insulation performance of current transformers of 330-750 kV substation are analyzed and compared.The effectiveness and availability of each method are discussed.Main features,advantages and disadvantages of each method and its corresponding standard are also described.展开更多
The paper provides a general overview of chemical processes leading to the degradation of oil-paper insulation in oil-immersed electrical current transformers. Previous knowledge available in literature is complemente...The paper provides a general overview of chemical processes leading to the degradation of oil-paper insulation in oil-immersed electrical current transformers. Previous knowledge available in literature is complemented by new results placing a specific emphasis on the physicochemical factors which affect the copper release in the insulation oil and the oil oxidation kinetics. It is demonstrated that various ageing processes interact with each other, with one or another process dominating under specific conditions. Comprehensive but disjoint studies focusing on separate sub-processes may produce rather misleading results, and occasionally, lie behind rather irrelevant quality demands imposed on the insulating liquids.展开更多
Through the long time track examination and disintegration to SF6 circuit breaker, we obtain the massive monitor data and massive pictures. The criteria of resuming insulation discharge failure conforming to CSO2/CH2S...Through the long time track examination and disintegration to SF6 circuit breaker, we obtain the massive monitor data and massive pictures. The criteria of resuming insulation discharge failure conforming to CSO2/CH2S>7, is quite broad to SO2 and the H2S concentration permission. Even if it reaches 100μL/L, it will not be in danger immediately to the safe operation of equipment. We may plan, arrange, and overhaul calmly. When obtaining the bare conductor overheating failure, it has not involved the resuming insulation. We may use the resuming insulation discharge failure criterion.展开更多
In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a vari...In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a variety of transformers are studied, and the applicable scope of the conversion formula is discussed emphatically, combined with the test results are analyzed of transformer insulation resistance value to temperature and oiliness and dielectric loss tangent to temperature and oiliness, and puts forward suggestions on how to improve the insulation performance of transformer.展开更多
Distribution transformers may experience insulation breakdown or degradation when exposed to the influences of high-altitude electromagnetic pulse(HEMP),thus posing significant threats and uncertainties to the safety ...Distribution transformers may experience insulation breakdown or degradation when exposed to the influences of high-altitude electromagnetic pulse(HEMP),thus posing significant threats and uncertainties to the safety and stable operations of power systems.Therefore,this study constructs a HEMP impact-test platform for distribution trans-formers,evaluates and analyses the development patterns of partial discharge(PD)under the action of different amplitude conduction environments,decomposes and identifies the types of damage defects,proposes a quantitative classification method for the degree of HEMP damage to distribution transformers based on PD detection.And reveals the damage mechanism of distribution transformers exposed to HEMP at different damage levels.The results show that distribution transformers undergo insulation breakdown when subjected to the influences of HEMP and that performance degradation often occurs before breakdown.As the amplitude of the HEMP environment increases,the degree of transformer damage continues to deteriorate,and both the amount of PD and the repetition rate of discharges exhibit a step-wise increase,with the increase in the repetition rate lagging behind that of the discharge amount.Based on the patterns of discharge quantity and repetition rate,transformer damage is categorised into three stages:undamaged,latent defect discharge,and severe defect discharge.展开更多
文摘The energy equilibrium equation and discrete ordinate methods are combined to establish the one-dimensional steady heat transfer mathematical model of multi-layer thermal insulations (MTIs) in metallic thermal protection systems. The inverse problem of heat transfer is solved by the genetic algorithm and data from the steady heat transfer experiment of fibrous thermal insulations. The density radiation attenuation coefficient, the albedo of fibrous thermal insulations and the surface emissivity of reflective screens are optimized. Finally, the one-dimensional steady heat transfer model of MTIs with optimized thermal physical parameters is verified by experimental data of the effective MTI conductivity.
基金supported by China Building Materials Research Institute
文摘In the present paper, a numerical model combining radiation and conduction for porous materials is developed based on the finite volume method. The model can be used to investigate high-temperature thermal insulations which are widely used in metallic thermal protection systems on reusable launch vehicles and high-temperature fuel cells. The effective thermal conductivities(ECTs) which are measured experimentally can hardly be used separately to analyze the heat transfer behaviors of conduction and radiation for high-temperature insulation. By fitting the effective thermal conductivities with experimental data, the equivalent radiation transmittance, absorptivity and reflectivity, as well as a linear function to describe the relationship between temperature and conductivity can be estimated by an inverse problems method. The deviation between the calculated and measured effective thermal conductivities is less than 4%. Using the material parameters so obtained for conduction and radiation, the heat transfer process in multilayer thermal insulation(MTI) is calculated and the deviation between the calculated and the measured transient temperatures at a certain depth in the multilayer thermal insulation is less than 6.5%.
基金supported by the Natural Science Foundation of the Fujian Province(2021J01109).
文摘The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighting and an improved technique for order of preference by similarity to ideal solution(TOPSIS)method to perform an objective and scientific evaluation of the transformer oil-paper insulation state.Firstly,multiple aging features are extracted from the recovery voltage polarization spectrum and the extended Debye equivalent circuit owing to the limitations of using a single feature for evaluation.A standard evaluation index system is then established by using the collected time-domain dielectric spectrum data.Secondly,this study implements the per-unit value concept to integrate the dimension of the index matrix and calculates the objective weight by using the random forest algorithm.Furthermore,it combines the weighting model to overcome the drawbacks of the single weighting method by using the indicators and considering the subjective experience of experts and the random forest algorithm.Lastly,the enhanced TOPSIS approach is used to determine the insulation quality of an oil-paper transformer.A verification example demonstrates that the evaluation model developed in this study can efficiently and accurately diagnose the insulation status of transformers.Essentially,this study presents a novel approach for the assessment of transformer oil-paper insulation.
文摘This paper deals with experimental investigations of the electrical and physical properties of oil impregnated insulation paper for power transformers at different temperatures. The ac breakdown voltage, tensile strength and water content of insulation papers impregnated in mineral oil for different time periods were investigated. The effect of insulation paper thickness on the electrical and mechanical properties has also been studied. The results showed that the breakdown voltage and the tensile strength decreased with increasing the time of immersion of insulation paper in oil at room temperature, at 5℃ and at -12℃. Also, the thermal aging effect on the characteristic of insulation paper has been studied. It was found that high temperatures affect the breakdown voltage and the tensile strength to a great extent.
基金Project supported by National Natural Science Foundation of China (51177101)
文摘CF3I has been widely considered as a potential alternative for SF6,because it has low global warming potential(GWP)but an insulation capability that is 1.2 times greater than that of SF6.In this paper,the electron swarm parameters of CF3I and its gas mixture with N2,including the effective ionization coefficient and electron drift velocity,are examined theoretically through the Boltzmann equation method in the condition of steady-state Townsend(SST)experiments.Based on the derived data of the limiting field strength of CF3I-N2gas mixture,taking into consideration of environmental aspects such as GWP,ozone depletion potential(ODP),liquefaction temperature and toxicity,we studied the possibility of applying the gas mixture as the insulation medium in gas-insulated switchgears(GIS)or cubic type gas-insulated switchgears(C-GIS).It is found that CF3I-N2gas mixtures contained 30%~70%CF3I perform comprehensively better than pure SF6and compressed N2,and especially in medium and low voltage environments,the boiling point of CF3I-N2gas mixture meets the domestic and global requirements in mid-low latitude regions.Therefore we conclude that the gas mixture is acceptable for replacing SF6as the insulation medium in C-GISs.
基金Science and Technology Projects of Gansu Electric Power Company(No.52274514005W)
文摘The online-monitoring methods for insulation performance of current transformers of 330-750 kV substation are analyzed and compared.The effectiveness and availability of each method are discussed.Main features,advantages and disadvantages of each method and its corresponding standard are also described.
文摘The paper provides a general overview of chemical processes leading to the degradation of oil-paper insulation in oil-immersed electrical current transformers. Previous knowledge available in literature is complemented by new results placing a specific emphasis on the physicochemical factors which affect the copper release in the insulation oil and the oil oxidation kinetics. It is demonstrated that various ageing processes interact with each other, with one or another process dominating under specific conditions. Comprehensive but disjoint studies focusing on separate sub-processes may produce rather misleading results, and occasionally, lie behind rather irrelevant quality demands imposed on the insulating liquids.
文摘Through the long time track examination and disintegration to SF6 circuit breaker, we obtain the massive monitor data and massive pictures. The criteria of resuming insulation discharge failure conforming to CSO2/CH2S>7, is quite broad to SO2 and the H2S concentration permission. Even if it reaches 100μL/L, it will not be in danger immediately to the safe operation of equipment. We may plan, arrange, and overhaul calmly. When obtaining the bare conductor overheating failure, it has not involved the resuming insulation. We may use the resuming insulation discharge failure criterion.
文摘In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a variety of transformers are studied, and the applicable scope of the conversion formula is discussed emphatically, combined with the test results are analyzed of transformer insulation resistance value to temperature and oiliness and dielectric loss tangent to temperature and oiliness, and puts forward suggestions on how to improve the insulation performance of transformer.
基金National Natural Science Foundation of China,Grant/Award Numbers:12305306,52007148National Key Laboratory of Intense Pulsed Radiation Simulation and Effect Foundation,Grant/Award Number:SKLIPR2204。
文摘Distribution transformers may experience insulation breakdown or degradation when exposed to the influences of high-altitude electromagnetic pulse(HEMP),thus posing significant threats and uncertainties to the safety and stable operations of power systems.Therefore,this study constructs a HEMP impact-test platform for distribution trans-formers,evaluates and analyses the development patterns of partial discharge(PD)under the action of different amplitude conduction environments,decomposes and identifies the types of damage defects,proposes a quantitative classification method for the degree of HEMP damage to distribution transformers based on PD detection.And reveals the damage mechanism of distribution transformers exposed to HEMP at different damage levels.The results show that distribution transformers undergo insulation breakdown when subjected to the influences of HEMP and that performance degradation often occurs before breakdown.As the amplitude of the HEMP environment increases,the degree of transformer damage continues to deteriorate,and both the amount of PD and the repetition rate of discharges exhibit a step-wise increase,with the increase in the repetition rate lagging behind that of the discharge amount.Based on the patterns of discharge quantity and repetition rate,transformer damage is categorised into three stages:undamaged,latent defect discharge,and severe defect discharge.