期刊文献+
共找到1,134篇文章
< 1 2 57 >
每页显示 20 50 100
Usefulness of myocardial performance index for assessing right ventricular function after percutaneous closure of atrial septal defect 被引量:2
1
作者 Jingdong Ding Genshan Ma +4 位作者 Yaoyao Huang Xiaoli Zhang Jian Zhu Rong Yang Fengxiang Lu 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第4期220-224,共5页
Objective Assessment of right ventricular function in patients with atrial septal defect(ASD)is difficult.The Doppler myocardial performance index(MPI)may provide a method of assessing function in these patients.The p... Objective Assessment of right ventricular function in patients with atrial septal defect(ASD)is difficult.The Doppler myocardial performance index(MPI)may provide a method of assessing function in these patients.The purposes of this study were to evaluate the right ventricular function and its changes in patients with ASD after transcatheter closure of ASD.Methods MPI,defined as the sum of isovolumic relaxation time and isovolumic contraction time derived by ejection time,was measured from tricuspid inflow and right ventricular outflow;Doppler velocity profiles recorded during routine echocardiography.Twenty nine patients(13 men,16 women;mean age 25.28±12.69,range 6 to 57 years)were diagnosed to secundum ASD[the stretched diameters of ASD were from 9 To 36(24.91±7.98)mm],and had a successfully placed Amplatzer septal occluder(ASO)(the sizes of ASO were from 11 to 40 mm);there were 81 sex-matched,age-matched healthy people(control group 41men,40 women;mean age 29.02±14.22,range 4 to 45 years).MPI was measured again on 3 days and 1 month after closure of ASD.Change in the study group was assessed and compared to the control subjects with structurally normal hearts.A complete 2-dimensional and Doppler echocardiographic examination was performed in all study groups.Results 1)The isovolumic relaxation and isovolumic contraction times[respectively(77.59±14.39)ms vs(60.93±12.94)ms,P<0.0001;(28.28±10.88)ms vs(23.64±9.01)ms,P=0.027]were prolonged,and ejection time[(260.65±21.86)ms vs(271.85±21.92)ms,P=0.033]was shortened in patients with ASD compared with that in control subjects,resulting in a marked increase in the MPI(0.40±0.07 vs 0.31±0.05,P<0.0001)from normal values;2)by Pearson's correlations,the MPI had no correlation with heart rate and blood pressure in control subjects and patients with ASD,but it correlated positively with age in patients with ASD;3)by Pearson's correlations,the MPI correlated positively with the diameter of ASD and pulmonary artery pressure;4)after transcatheter closure of ASD,the MPI decreased markedly.Conclusions 1)MPI is a conceptually new,simple,and reproducible Doppler index in patients with ASD;2)MPI is free from the effect of age,heart rate and blood pressure;(3)MPI appears to be relatively dependent on changes in the diameter of ASD and pulmonary artery pressure;4)the right ventricular function was improved after transcatheter closure of ASD. 展开更多
关键词 HEART atrial septal defect right ventricular function myocardial performance index
暂未订购
QUANTIFICATION OF RIGHT VENTRICULAR FUNCTION IN ATRIAL SEPTAL DEFECT USING ULTRASOUND- BASED STRAIN RATE IMAGING
2
作者 孟祥春 孙锟 +5 位作者 张玉奇 黄美蓉 高伟 张志芳 沈蓉 陈树宝 《Journal of Shanghai Second Medical University(Foreign Language Edition)》 2005年第2期112-115,127,共5页
Objective To study the validation of ultrasound-based strain rate imaging in the quantitative assessment of right ventricular (RV) function in atrial septal defect (ASD). Methods Tissue Doppler images (TDI) of R... Objective To study the validation of ultrasound-based strain rate imaging in the quantitative assessment of right ventricular (RV) function in atrial septal defect (ASD). Methods Tissue Doppler images (TDI) of RV longitudinal and short axes were recorded from the apical 4-chamber view and the subcostal short-axis view in 18 normal controls, 28 children with ASD and 14 children after Amplazter closure of ASD respectively. Peak systolic velocities ( V), peak systolic strain rates (SR), peak systolic strains (S) at the basal segment, middle segment of RV lateral wall and the basal septum from the longitudinal axis, the middle segment of RV free waU from the short axis were quantitatively measured using QLAB^TM tissue velocity quantification software system respectively. Peak dp/ dt from the RV isovolumic contraction determined during the right cardiac catheterization in 28 ASD patients was used as the gold standard of RV contractility. Peak systolic indices were compared against max dp/dt by linear correlation, Results Peak systolic indices at the basal and middle segments of RV lateral wall from the longitudiual axis increased significantly in 28 ASD patients. Peak systolic indices at the basal septum also increased in patient group, but not significantly. Significant decreases in peak systolic indices at the basal and middle segments of RV lateral wall were observed after the Amplatzer closure in 14 ASD patients. There was no significant difference at the middle segment of RV free wall from the short axis between patient group and normal control. A strong correlation was found between max dp/dt and peak systolic indices at the basal and middle segments of RV lateral wal l ( P 〈 0. 05 ). Conclusion Ultrasound-based strain rate imaging can assess quantitatively RVfunction in CHD. Peak systolic strains determined at the basal and middle segments of RV lateral wall are strong noninvasive indices of RV contractility. 展开更多
关键词 right ventricular function strain rate strain strain rate imaging
暂未订购
Effect of arotinolol on right ventricular function in patients with dilated cardiomyopathy 被引量:1
3
作者 Hong Yang Li Xu Yongkang Tao Zhimin Xu Xiuqing Du Naqiang Lu Kefei Dou Jinglin Zhao Xianqi Yuan Yanfen Zhao Rongfang Shi Chaomei Fan 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第3期170-173,共4页
Objective Dilated cardiomyopathy(DCM) is generally considered to be accompanied by both left and right ventricular dysfunction,but most studies only analyze the left ventricular function. In this study,we evaluated th... Objective Dilated cardiomyopathy(DCM) is generally considered to be accompanied by both left and right ventricular dysfunction,but most studies only analyze the left ventricular function. In this study,we evaluated the effect of arotinolol on right ventricular function in patients with DCM. Methods Right ventricular ejection fraction(RVEF) and right ventricular diameter(RVD) were measured by two-dimensional echocardiography(2-DE) in 33 DCM patients;RVEF measured by first-pass radionuclide angiography(FPRA) was compared with that by 2-DE. Results The treatment with arotinolol for one year resulted in a reduction in the right ventricular diameter(baseline,23.0 ± 8.3 mm vs after one-year treatment,20.7 ± 5.4 mm;P=0.004 ) and an associated increase in ejection fraction(baseline,36.9 ± 10.3% vs after one-year treatment,45.8 ± 9.6%;P < 0.001 ) ;there is a high correlation between the 2-DE method and radionuclide ventriculographic method. The correlation coefficient is 0.933(P<0.001) . Conclusion Arotinolol therapy could not only improve left ventricular function,but also improve right ventricular function in DCM patients. 展开更多
关键词 DILATED CARDIOMYOPATHY AROTINOLOL right ventricular function
暂未订购
Quantification of Right Ventricular Function in Atrial Septal Defect Using Ultrasound-Based Strain Rate Imaging
4
《上海第二医科大学学报》 CSCD 北大核心 2005年第11期1191-1191,共1页
关键词 心室功能 检查技术 心脏损伤 超频率音响
暂未订购
Echocardiography evaluation of right ventricular structure and function in patients with chronic obstructive pulmonary disease 被引量:2
5
作者 YANG Shi-fang LI Xiao-ming +3 位作者 FU Ming LIN Qi WU Jian GAO Xing-lin 《South China Journal of Cardiology》 CAS 2018年第4期244-250,共7页
Background Early and accurate assessment of right ventricular changes in patients with Chronic obstructive pulmonary disease(COPD)is of great value,because these changes are important factors affecting the prognosis o... Background Early and accurate assessment of right ventricular changes in patients with Chronic obstructive pulmonary disease(COPD)is of great value,because these changes are important factors affecting the prognosis of patients with COPD. This study aimed to investigate the changes of right ventricular structure and function by electrocardiography in COPD patients,and to evaluate the correlations of pulmonary function,COPD assessment test(CAT)score with the changes. Methods According to the"ABCD"2016 Global initiative for chronic obstructive pulmonary disease(GOLD)update,stable COPD patients were divided into four groups:GOLD A group,GOLD B group,GOLD C group,and GOLD D group. There were 30 patients of each group enrolled from December 2016 to December 2017 in Guangdong General Hospital. During the same period,30 physical examination volunteers were enrolled as the healthy control group. Pulmonary function and echocardiography were performed in all subjects. All COPD patients completed CAT test. One-way ANOVA and SNK-q test were used to analyze the differences in parameters of right ventricular structure and function between different GOLD groups and healthy controls. Pearson correlation analysis was used to analyze the relation between CAT score,forced expiratory volume in one second(FEV1)and echocardiographic parameters. Results Compared with control group,right ventricular wall thickness(RVWT)was significantly thicker in patients of GOLD A,B and C groups(P<0.001),but not for GOLD D group. In sharp contrast,only in the patients of GOLD D group,right ventricular basal diameter(RV basal diameter)and right ventricular outflow tract(RVOT)(2.84±0.56 cm and 4.63±0.54 cm)were significantly longer than those in healthy controls and other GOLD groups(P<0.001).The patients of GOLD C and D groups had higher E/A ratio and E/e′ ratio compared with control group,GOLD A and B groups(P<0.001). But only in GOLD D group,the fractional area change(FAC)and tricuspid annular plane systolic excursion(TAPSE)were decreased significantly,compared with control group and other GOLD groups(P<0.001). The right ventricular index of myocardial performance(RIMP)in GOLD B,C and D groups was increased significantly compared with healthy control and GOLD A group(P<0.001). Moreover,correlation analysis showed that no correlations were found between FEV1 and all parameters of right ventricular structure and function,but CAT was positively correlated with RIMP(r=0.696,P=0.019). Conclusions Echocardiography could be a good assessment for right ventricular structure and function in COPD patients. Right ventricular wall thickening and diastolic dysfunction occur in the early stage of COPD,followed by right ventricular volume enlargement and systolic dysfunction. 展开更多
关键词 chronic obstructive pulmonary disease ECHOCARDIOGRAPHY ventricular structure right ventricular function
原文传递
Early Intervention of Tongxinluo(通心络) on Right Ventricular Function Assessed by Echocardiography in Rats with Pulmonary Arterial Hypertension Induced by Monocrotaline
6
作者 GAO Lu LI Shao-dan +2 位作者 ZHANG Yin LIU Yi YANG Ming-hui 《Chinese Journal of Integrative Medicine》 SCIE CAS CSCD 2020年第12期913-920,共8页
Objective:To investigate the effect of early intervention of Tongxinluo(通心络,TXL)on right ventricular function(RVF)of rats with pulmonary arterial hypertension(PAH)induced by monocrotaline(MCT).Methods:A total of 30... Objective:To investigate the effect of early intervention of Tongxinluo(通心络,TXL)on right ventricular function(RVF)of rats with pulmonary arterial hypertension(PAH)induced by monocrotaline(MCT).Methods:A total of 30 adult male Sprague-Dawley rats were assigned to 5 groups with complete random experiment design:Sham group(Sham),MCT group,TXL group,sildenafil(SIL)group and combination group(TXL+SIL),6 rats in each group.Rats were injected with 50 mg/kg MCT solution for inducing PAH model except for those in the sham group.From the day of modeling,rats of TXL,SIL and TXL+SIL groups were given TXL(1.2 g/kg),SIL(10 mg/kg)and combination solution(TXL:1.2 g/kg,SIL:10 mg/kg)respectively,and rats in Sham and MCT groups were given normal saline(5 m L/kg).The samples were collected and tested after 21 consecutive days of intragastric administration.Echocardiography was used to measure the related indices of RVF,including pulmonary arterial flow spectrum,pulmonary artery diameter(PAD),right ventricular wall thickness(RVWT),right ventricular diameter(RVD),tricuspidannular plane systolic excursion(TAPSE),right atrium transverse diameter(RAT),and inferior vena cava diameter(IVCD).Elastic Verhoeff-Van Gieson staining was adopted to measure the percentage of wall thickness(WT%)of pulmonary arteriols.Hematoxylin-eosin staining was used to measure the cross-sectional area(CSA)of right ventricular cardiomyocytes.Results:MCT-induced PAH rat model was successfully established.In MCT group the wall of pulmonary arterioles exhibited a prominent-increase thickness,PAD,RVWT,RVD,RAT,IVCD,WT%,right ventricular hypertrophy index(RVHI)as well as CSA of RV cardiomyocyte significantly increased(all P<0.01),and TAPSE markedly decreased(P<0.01).At the same time,TXL prominently improved all of the above indices(all P<0.01).In comparison with SIL,TXL significantly reduced RVD(P<0.05)and decreased CAS of RV cardiomyocytes(P<0.01),but TAPSE in SIL group was much larger than in TXL group(P<0.01).Moreover,TAPSE in TXL+SIL group was larger than that in TXL group(P<0.01),while the two groups performed equally well in terms of the other indices.Conclusion:Early intervention of TXL could inhibit pulmonary arterioles remodeling,and improve RVF by attenuating right ventricular hypertrophy,and TXL has a stronger effect on inhibiting right ventricular remodeling than SIL. 展开更多
关键词 TONGXINLUO early intervention pulmonary arterial hypertension right ventricular function ECHOCARDIOGRAPHY
原文传递
Real-time Three-dimensional Echocardiography:A Feasible and Accurate Method for Measuring Right Ventricular Function in Pulmonary Hypertension
7
作者 Ashfaq Ahmad Yifan Zou +5 位作者 Peng Zhang Lingling Li Xiaoyu Wang Ahmed Ali Mohsen Yousen Wang Fenling Fan 《Cardiology Discovery》 2023年第4期261-268,共8页
Right ventricular function is independently associated with poor clinical outcomes in patients with various cardiovascular diseases including pulmonary hypertension(PH).The complex geometry and mode of contractility m... Right ventricular function is independently associated with poor clinical outcomes in patients with various cardiovascular diseases including pulmonary hypertension(PH).The complex geometry and mode of contractility means the right ventricle(RV)inlet and outlet are not in line;hence,2-dimensional echocardiography fails to accurately quantify RV volumes and function in such patients.Three-dimensional echocardiography(3DE)allows for reliable and reproducible quantification of RV volumes and function by overcoming these limitations of conventional echocardiography.This review focuses on the 3DE assessment of RV function in patients with PH and discusses the following points:(1)acquiring an RV data set for 3DE imaging,including details of all available 3DE systems and software utilized in daily practice;(2)the reliability and feasibility of RV remodeling measured with 3DE with different modalities in patients with PH;and(3)the prognostic value of 3DE-derived RV function in such patients. 展开更多
关键词 Pulmonary hypertension Three-dimensional echocardiography Cardiac magnetic resonance right ventricular volumes right ventricular function
原文传递
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
8
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
暂未订购
Quantitative Assessment of Right Ventricular Systolic Function by the Analysis of Right Ventricular Contrast Time-intensity Curve 被引量:2
9
作者 王林 邓又斌 +1 位作者 李天亮 杨好意 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2004年第6期607-609,共3页
Summary: To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5 % sonicated human albumin was injec... Summary: To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5 % sonicated human albumin was injected intravenously at a does of 0.08 ml/kg into 10 dogs at baseline status and cardiac insufficiency. Apical four-chamber view was observed for washin and washout of contrast agent from right ventricle. The parameters of TIC were obtained by curve fitting. The differences of parameters were analyzed in different states of cardiac functions. Among the parameters derived from TIC, the time constant (k) was decreased significantly with decline of cardiac function (P<0.001). But half-time of decent of peak intensity (HT) and mean-transit-time (MTT) of washout were increased significantly (P<0.001). The k was strongly related to cardiac output of right ventricle (CO) and ejection fraction (EF) of left ventricle and fractional shortening (FS) of left ventricle. Right ventricular systolic function could be assessed reliably by the parameters derived from TIC with right ventricular contrast echocardiography. The k, HT and MTT are reliable indices for quantitative assessment of right ventricular systolic function. 展开更多
关键词 time-intensity curve curve fitting right ventricular contrast right ventricular systolic function
暂未订购
Correlation between ductus venosus spectrum and right ventricular diastolic function in isolated single-umbilical-artery foetus and normal foetus in third trimester 被引量:1
10
作者 Tian-Gang Li Fang Nie Xiao-Yan Xu 《World Journal of Clinical Cases》 SCIE 2020年第23期5866-5875,共10页
BACKGROUND Single umbilical artery(SUA)is the most common umbilical cord malformation in prenatal diagnosis.The presence of an SUA can cause blood circulation disorder in the foetus and functional changes of the foeta... BACKGROUND Single umbilical artery(SUA)is the most common umbilical cord malformation in prenatal diagnosis.The presence of an SUA can cause blood circulation disorder in the foetus and functional changes of the foetal heart,affecting foetal circulation.The right ventricular diastolic functions in foetuses with isolated SUA and in normal foetuses in the third trimester were evaluated using the spectral Doppler of blood flow in the foetal ductus venosus(DV).AIM To evaluate the right ventricular diastolic functions in foetuses with isolated SUA and in normal foetuses in the third trimester.METHODS Colour Doppler was used to measure the spectrum of foetal DV and tricuspid orifice in 34 foetuses with isolated SUA aged 28-39 wk and in age-matched healthy controls.The DV flow velocities and velocity ratios were measured.The early passive/late active(E/A)ratio at the tricuspid orifice and tissue Doppler Tei index of the foetal right ventricular in the two groups were also measured.RESULTS During the third trimester,the isolated SUA group showed a lower‘a’-wave peak velocity in the DV than the control group(P<0.05).The correlations between the velocity ratios and E/A ratio at the tricuspid orifice in the two groups were analysed,and the correlation between the ventricular late diastolic velocity/ventricular diastolic peak flow velocity and E/A ratios was the best(R^2of the isolated SUA group:0.520;R2 of the control group:0.358).The correlations between the velocity ratios and tissue Doppler Tei index of foetal right ventricular in the two groups were analysed,and the correlation between the pulsatility index for veins(PIV)and tissue Doppler Tei index ratios was the best(R2 of the isolated SUA group:0.865;R2 of the control group:0.627).CONCLUSION In the isolated SUA group,the atrial systolic peak velocity‘a’decreased,and this finding might be related to the changes in foetal cardiac functions.The ratio of ventricular late diastolic velocity to ventricular diastolic peak flow velocity was closely related to the E/A ratio at the tricuspid valve and can be used to identify changes in the right ventricular diastolic functions of isolated SUA and healthy foetuses.PIV was closely related to the tissue Doppler Tei index of the foetal right ventricular and can be used to identify the right ventricular overall functions of isolated SUA and healthy foetuses. 展开更多
关键词 Isolated single umbilical artery Ductus venosus VELOCITY right ventricular diastolic function FOETUS
暂未订购
Evaluation of Right Ventricular Global Longitudinal Function in Patients with Tetralogy of Fallot by Two-dimensional Ultrasound Speckle Tracking Imaging 被引量:2
11
作者 李玉曼 谢明星 +7 位作者 王新房 吕清 卢晓芳 杨亚利 马红 方凌云 张静 李卫芹 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2010年第1期126-131,共6页
Quantification of right ventricular(RV)volume and function remains a challenge because of RV complex geometry by conventional echocardiography.The purpose of this study was to assess RV global longitudinal function in... Quantification of right ventricular(RV)volume and function remains a challenge because of RV complex geometry by conventional echocardiography.The purpose of this study was to assess RV global longitudinal function in patients with tetralogy of Fallot(TOF)by 2-dimensional ultrasound speckle tracking imaging(STI).Thirty-eight patients with TOF were enrolled in this study and divided into child group(n=25)and adult group(n=13)according to age.Thirty-eight age-and sex-matched normal subjects were selected as c... 展开更多
关键词 ECHOCARDIOGRAPHY tetralogy of Fallot ventricular function GLOBAL right 2-dimensional speckle tracking
暂未订购
Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
12
作者 Jia-Xing Sun Ai-Lu Cai Li-Mei Xie 《World Journal of Clinical Cases》 SCIE 2019年第15期2003-2012,共10页
BACKGROUND Heart defects are the most common congenital malformations in fetuses.Fetal cardiac structure and function abnormalities lead to changes in ventricular volume.As ventricular volume is an important index for... BACKGROUND Heart defects are the most common congenital malformations in fetuses.Fetal cardiac structure and function abnormalities lead to changes in ventricular volume.As ventricular volume is an important index for evaluating fetal cardiovascular development,an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment.The new intelligent spatiotemporal image correlation(iSTIC)technology acquires high-resolution volumetric images.In this study,the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function.AIM To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses.METHODS Between October 2014 and September 2015,a total of 123 pregnant women received prenatal ultrasound examinations in our hospital.iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software.Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve.The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume.The data were used to calculate the right stroke volume,the right cardiac output,and the right ejection fraction.The correlations of changes between the above-mentioned indices and gestational age were analyzed.The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer,and the intraobserver agreement measurements were calculated.RESULTS Among the 123 normal fetuses,the mean right ventricular end-diastolic volume increased from 0.99±0.34 mL at 22 wk gestation to 3.69±0.36 mL at 35+6 wk gestation.The mean right ventricular end-systolic volume increased from 0.43±0.18 mL at 22 wk gestation to 1.36±0.22 mL at 35+6 wk gestation.The mean right stroke volume increased from 0.62±0.29 mL at 22 wk gestation to 2.33±0.18 mL at 35+6 wk gestation.The mean right cardiac output increased from 92.23±40.67 mL/min at 22 wk gestation to 335.83±32.75 mL/min at 35+6 wk gestation.Right ventricular end-diastolic volume,right ventricular end-systolic volume,right stroke volume,and right cardiac output all increased with gestational age and the correlations were linear(P<0.01).Right ejection fraction had no apparent correlation with gestational age(P>0.05).CONCLUSION Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability.iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function. 展开更多
关键词 ULTRASONOGRAPHY FETUS INTELLIGENT SPATIOTEMPORAL image correlation right ventricular volume Cardiac function
暂未订购
Real-time Three-dimensional Echocardiography in Assessment of Left Ventricular and Right Ventricular Volumes
13
作者 YingYang Xin-fangWang Ming-xingXie JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期236-236,共1页
关键词 ADULT Echocardiography Three-Dimensional Heart Ventricles Humans Stroke Volume ventricular function Left ventricular function right
暂未订购
Right ventricular septal pacing: Safety and efficacy in a long term follow up 被引量:5
14
作者 Eraldo Occhetta Gianluca Quirino +10 位作者 Lara Baduena Rosaria Nappo Chiara Cavallino Emanuela Facchini Paolo Pistelli Andrea Magnani Miriam Bortnik Gabriella Francalacci Gabriele Dell’Era Laura Plebani Paolo Marino 《World Journal of Cardiology》 CAS 2015年第8期490-498,共9页
AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 ... AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects. 展开更多
关键词 right ventricular SEPTAL PACING Parahisian PACING RESYNCHRONIZATION therapy Left ventricular CARDIAC function PERMANENT CARDIAC PACING
暂未订购
小青龙汤对野百合碱诱导肺动脉高压大鼠右心功能的影响及机制
15
作者 祁磊 张慧菲 +5 位作者 龚玲 何吉富 陈文静 牛卫品 李晓 姜月华 《中国实验方剂学杂志》 北大核心 2026年第4期11-19,共9页
目的:本研究拟通过建立野百合碱(MCT)诱导的肺动脉高压(PAH)大鼠模型,系统评估小青龙汤对模型大鼠右心功能的保护效应,并进一步揭示其调控右心功能的作用机制。方法:60只雄性SD大鼠随机分为正常组,模型组,小青龙汤低、中、高剂量(XQLT-L... 目的:本研究拟通过建立野百合碱(MCT)诱导的肺动脉高压(PAH)大鼠模型,系统评估小青龙汤对模型大鼠右心功能的保护效应,并进一步揭示其调控右心功能的作用机制。方法:60只雄性SD大鼠随机分为正常组,模型组,小青龙汤低、中、高剂量(XQLT-L、XQLT-M、XQLT-H)组和贝前列素钠片(BST)组,除正常组外,其余各组大鼠使用MCT(60 mg·kg^(-1))单次皮下注射诱导PAH模型,注射3周后,XQLT-L/M/H组分别灌胃小青龙汤3.07、6.14、12.28 g·kg^(-1)·d^(-1),BST组灌胃贝前列素钠12.6μg·kg^(-1)·d^(-1),模型组灌胃等量生理盐水,共给药3周。右心导管插管法检测右心室收缩压(RVSP);超声心动图评价心功能;右心室组织称质量计算右心室肥厚指数(RVHI);苏木素-伊红(HE)染色、马松(Masson)染色、透射电镜观察心脏组织形态;超高效液相色谱-串联质谱法(UPLC-MS/MS)分析血清代谢组变化;数据非依赖采集蛋白质组学检测右心室差异蛋白,蛋白免疫印迹法(Western blot)检测解偶联蛋白3(UCP3)、磷酸肌醇3-激酶α催化亚基p110α(PIK3CA)、L1细胞黏附分子(L1CAM)、醌氧化还原酶(CRYZ)蛋白表达;UPLC-MS/MS分析小青龙汤的药物组成成分。结果:与正常组比较,模型组大鼠RVSP和右心肥厚指数(RVHI)明显升高(P<0.05),心肌组织形态出现病理性改变;与模型组比较,各给药组RVSP和RVHI不同程度降低、心功能和心肌组织形态显著改善,小青龙汤各给药组中,XQLT-M组药效最佳(P<0.05),与BST组接近。血清代谢组结果显示,与模型组比较,小青龙汤组出现105个差异代谢物[变量重要性投影(VIP)值>1且P<0.05],其中58个升高,47个降低,京都基因与基因组百科全书(KEGG)数据库富集提示,小青龙汤的干预导致苯丙氨酸代谢下调(P<0.01),而不饱和脂肪酸生物合成上调(P<0.05)。蛋白质组学结果显示,与正常组比较,MCT诱导右心室出现982个差异蛋白,其中455个蛋白上调、527个蛋白下调(|差异倍数(FC)|>1.3,P<0.05);与模型组比较,小青龙汤组出现237个蛋白差异表达,其中124个蛋白上调,113个蛋白下调,二者有57个共有差异蛋白,KEGG富集提示,小青龙汤主要参与矿物质吸收、核糖体生物发生、过氧化物酶体、糖酵解/糖异生、剪接体、甲状腺激素信号通路等调节。Western blot显示与模型组比较,小青龙汤组UCP3、PIK3CA、L1CAM蛋白表达上调,CRYZ蛋白表达下调(P<0.05)。结论:小青龙汤对MCT诱导PAH大鼠具有右心功能保护作用,其机制与维持心肌稳态、减轻右心室重构有关。 展开更多
关键词 肺动脉高压 小青龙汤 右心功能 蛋白质组学
原文传递
右心导管检查在心源性休克中的应用进展
16
作者 刘立波 李江 +2 位作者 张静 杨丽睿 孙艺红 《心血管病学进展》 2026年第2期105-111,共7页
右心导管检查(RHC)是心源性休克(CS)评估与管理的核心手段,可获取充盈压、心输出量与氧供需等关键血流动力学信息,用于确立休克类型,识别左、右心室及双心室衰竭,并指导容量管理、血管活性药、正性肌力药以及机械循环支持的应用、升级... 右心导管检查(RHC)是心源性休克(CS)评估与管理的核心手段,可获取充盈压、心输出量与氧供需等关键血流动力学信息,用于确立休克类型,识别左、右心室及双心室衰竭,并指导容量管理、血管活性药、正性肌力药以及机械循环支持的应用、升级和撤除。多项观察性研究提示,RHC在CS中的使用与院内死亡率降低相关,尤其在重症及需高级生命支持患者中具有突出价值。尽管随机对照研究仍有限,但现有证据支持RHC在CS管理中的重要地位。未来需进一步验证其对长期预后的影响,并推动非侵入性替代技术的发展。 展开更多
关键词 右心导管检查 心源性休克 血流动力学 机械循环支持 右心功能
暂未订购
二维斑点追踪超声心动图评估高脂血症对2型糖尿病患者右室功能的影响及心室相互关系分析
17
作者 余姝琦 孔翼婷 +4 位作者 张月 周雅东 闫玉莲 付奇环 刘蓉 《临床超声医学杂志》 2026年第1期71-76,共6页
目的应用二维斑点追踪超声心动图(2D-STE)评估高脂血症(HLP)对2型糖尿病(T2DM)患者右室功能的影响,分析右室与左室功能间的相互关系。方法选取我院收治的T2DM患者118例,分为合并HLP患者67例(HLP组)和未合并HLP患者51例(NHLP组);另选取... 目的应用二维斑点追踪超声心动图(2D-STE)评估高脂血症(HLP)对2型糖尿病(T2DM)患者右室功能的影响,分析右室与左室功能间的相互关系。方法选取我院收治的T2DM患者118例,分为合并HLP患者67例(HLP组)和未合并HLP患者51例(NHLP组);另选取同期体检健康者50例为正常对照组。收集各组空腹血糖(FPG)、糖化血红蛋白(HbA1c)、总胆固醇(TC)、甘油三酯(TG)、低密度脂蛋白胆固醇(LDL-C)、高密度脂蛋白胆固醇(HDL-C);应用2D-STE获取左室整体纵向应变(LVGLS)、左室整体圆周应变(LVGCS)、右室整体纵向应变(RVGLS)、右室游离壁纵向应变(RVFWLS),比较两组上述参数的差异。采用Pearson相关分析法分析RVFWLS、RVGLS与LVGLS、LVGCS、TC、TG、HDL-C、LDL-C的相关性。采用多元线性回归分析TG、LVGLS对T2DM患者右室功能参数(RVGLS)的影响;采用因果逐步回归法进行中介效应分析,将LVGLS作为中介添加到回归分析,评估LVGLS是否介导TG对RVGLS的影响。结果NHLP组和HLP组FPG、HbA1c均高于正常对照组,HLP组TC、TG、LDL-C均高于正常对照组和NHLP组,差异均有统计学意义(均P<0.05)。正常对照组、NHLP组、HLP组RVFWLS、RVGLS、LVGLS均依次降低,两两比较差异均有统计学意义(均P<0.05)。相关性分析显示,RVFWLS与LVGLS、LVGCS均呈正相关,与TC、TG均呈负相关(均P<0.01);RVGLS与LVGLS、LVGCS均呈正相关,与TC、TG、LDL-C均呈负相关(均P<0.05)。多元线性回归及中介效应分析显示,TG与RVGLS呈独立负相关(β=-0.297,P<0.05),但此效应在纳入LVGLS后消失(β=-0.006,P=0.949);LVGLS与RVGLS呈独立正相关(β=0.690,P<0.001),TG对RVGLS的负面影响主要由LVGLS介导(间接效应:-0.290,P<0.05)。结论合并HLP的T2DM患者表现出较单纯T2DM患者更严重的右室功能障碍,HLP可能通过损害左室功能介导右室功能障碍。 展开更多
关键词 斑点追踪超声心动图 二维 2型糖尿病 高脂血症 右室功能 左室功能 心室相互关系
暂未订购
MHD患者右室收缩功能及心脏瓣膜改变的超声心动图表现
18
作者 朱燕云 《中国医疗器械信息》 2026年第4期17-20,共4页
目的:探讨维持性血液透析(MHD)患者右室收缩功能及心脏瓣膜改变的超声心动图表现。方法:回顾性分析2023年8月~2024年8月在本院收治的70例MHD患者治疗前(对照组)、治疗后(试验组)心脏瓣膜的厚度、钙化、瓣膜反流及狭窄程度变化;比较两组... 目的:探讨维持性血液透析(MHD)患者右室收缩功能及心脏瓣膜改变的超声心动图表现。方法:回顾性分析2023年8月~2024年8月在本院收治的70例MHD患者治疗前(对照组)、治疗后(试验组)心脏瓣膜的厚度、钙化、瓣膜反流及狭窄程度变化;比较两组右心室面积变化分数(RVFAC)、三尖瓣环收缩期位移(TAPSE)、组织多普勒三尖瓣环收缩期峰值速度(S’)。结果:试验组主动脉瓣、二尖瓣、三尖瓣瓣膜厚度均高于对照组(P<0.05);试验组瓣膜钙化例数高于对照组(P<0.05);试验组二尖瓣反流及狭窄、主动脉瓣反流及狭窄、三尖瓣反流例数高于对照组(P<0.05);两组的三尖瓣狭窄、肺动脉瓣反流及狭窄例数差异无统计学意义(P>0.05);试验组RVFAC、TAPSE、S’均低于对照组(P<0.05)。结论:超声心动图可较准确发现MHD患者心脏瓣膜改变及右室收缩功能变化。 展开更多
关键词 维持性血液透析 瓣膜厚度 钙化 反流 狭窄 右室功能
暂未订购
单纯三尖瓣外科手术围术期机械通气时间延长的危险因素分析
19
作者 田书铭 金岩 +3 位作者 尹宗涛 赵洋 刘宇 都业君 《中国心血管病研究》 2026年第1期24-29,共6页
目的探讨单纯三尖瓣手术后机械通气时间延长(PMV)的危险因素,以选择合适的手术时机,提高围手术期成功率和改善预后。方法选择2006年1月至2023年10月在北部战区总医院心外科行单纯三尖瓣成形或置换手术治疗的158例患者,根据术后机械通气... 目的探讨单纯三尖瓣手术后机械通气时间延长(PMV)的危险因素,以选择合适的手术时机,提高围手术期成功率和改善预后。方法选择2006年1月至2023年10月在北部战区总医院心外科行单纯三尖瓣成形或置换手术治疗的158例患者,根据术后机械通气时间是否≥24 h分为PMV组(n=54)和非PMV组(n=104)。结果158例患者中三尖瓣置换109例,三尖瓣成形49例,两组之间术式无显著差异。单因素分析发现,两组中二次手术比率、体外循环时间、肝功能、B型利钠肽原(BNP)、左心室射血分数(LVEF)、心房内径、右心室内径、下腔静脉内径及其吸憋率无明显统计学差异(P均>0.05)。PMV组患者的年龄明显高于非PMV组[(51.93±15.09)岁比(59.78±10.25)岁,P=0.027],且女性明显多于男性(P=0.024)。PMV组术前房颤比例明显高于非PMV组(41%比34%,P=0.048),且术前肾功能异常的比例明显高于非PMV组(P=0.001)。PMV组术前右心室面积变化率(RVFAC)明显小于非PMV组[(36.43±4.23)%比(31.49±3.68)%,P=0.046],术前三尖瓣瓣环收缩期位移(TAPSE)明显小于非PMV组[(15.14±4.89)mm比(9.53±6.36)mm,P=0.025],术前三尖瓣瓣环侧壁和室间隔处的收缩期峰速(TDIIVSs’和TDITVs’)明显小于非PMV组[(8.46±2.64)cm/s比(6.63±1.85)cm/s,(12.44±4.53)cm/s比(9.13±3.36)cm/s,P=0.004和0.003]。多因素分析发现,术前肌酐水平升高和TDITVs’是术后机械通气时间延长的危险因素;TDITVs’对三尖瓣手术后机械通气时间延长具有较大的预测价值(AUC=0.80),当TDITVs’≤11.65cm/s时增加了术后发生PMV的风险。结论右心室收缩功能减低是因三尖瓣关闭不全而需要手术患者出现术后机械通气时间延长的危险因素,TDITVs’的长期随访可用来判断三尖瓣关闭不全患者的手术时机。 展开更多
关键词 三尖瓣反流 三尖瓣关闭不全 机械通气时间 危险因素 右心室收缩功能 三尖瓣瓣环侧壁处收缩期峰速
暂未订购
Impact of Cystic versus Cylindrical Types of Bronchiectasis on Pulmonary and Cardiac Functions
20
作者 Wafaa Ali Hassan Ahmed Esmail Ziada Eman Abu El-hamd 《Open Journal of Respiratory Diseases》 2014年第1期12-17,共6页
Background: The combination of the clinical features, HRCT score and echocardiographic evidence of pulmonary hypertension help assess the prognosis in bronchiectasis. Aim: To test whether pulmonary and cardiac functio... Background: The combination of the clinical features, HRCT score and echocardiographic evidence of pulmonary hypertension help assess the prognosis in bronchiectasis. Aim: To test whether pulmonary and cardiac functions associated with bronchiectasis would differ according to its type (cystic versus cylindrical) utilizing HRCT score, PFTs and echocardiography. Patients and Methods: A cross-sectional study of patients with bronchiectasis was conducted at Chest and Internal Medicine Departments at Assiut University Hospital, Egypt. The diagnosis of bronchiectasis type was based on HRCT findings. PFTs, HRCT score and echocardiography were assessed in all cases. Results: We studied 56 patients with bronchiectasis;31 were cystic (group A) and 25 were cylindrical (group B). Forced vital capacity (FVC%) and Dlco% were significantly lower in group A (P as compared with group B;whereas FEF 25%-75% and FEV1 (0.04) were lower in group B. Global HRCT score, RVD and SPAP were significantly higher in group A (P = 0.002) and correlated with FEV1% (r = ?0.51), and with SPAP (r = 0.16). Conclusions: Airway obstruction and small airway dysfunction were more significantly seen in cylindrical bronchiectasis. Patients with cystic bronchiectasis had significantly, higher global HRCT scores, RVD and SPAP. HRCT scores correlate with FEV 1% and SPAP and could be a predictor of future PH. Routine echocardiographic assessment of patients with bronchiectasis, particularly in those with cystic disease is highly recommended. 展开更多
关键词 High Resolution COMPUTERIZED Tomography PULMONARY function Tests right ventricular Diameter SYSTOLIC PULMONARY Artery Pressure
暂未订购
上一页 1 2 57 下一页 到第
使用帮助 返回顶部