As the stiffness of the elastic support varies with the physical-chemical erosion and mechanical friction, model catastrophe of a single degree-of-freedom(DOF) isolation system may occur. A 3-DOF four-point-elastic-su...As the stiffness of the elastic support varies with the physical-chemical erosion and mechanical friction, model catastrophe of a single degree-of-freedom(DOF) isolation system may occur. A 3-DOF four-point-elastic-support rigid plate(FERP) structure is presented to describe the catastrophic isolation system. Based on the newly-established structure, theoretical derivation for stiffness matrix calculation by free response(SMCby FR) and the method of stiffness identification by stiffness matrix disassembly(SIby SMD)are proposed. By integrating the SMCby FR and the SIby SMD and defining the stiffness assurance criterion(SAC), the procedures for stiffness identification of a FERP structure(SIFERP) are summarized. Then, a numerical example is adopted for the SIFERP validation, in which the simulated tested free response data are generated by the numerical methods, and operation for filtering noise is conducted to imitate the practical application. Results in the numerical example demonstrate the feasibility and accuracy of the developed SIFERP for stiffness identification.展开更多
Output-only structural identification is developed by a refined Frequency Domain Decomposition(rFDD) approach, towards assessing current modal properties of heavy-damped buildings(in terms of identification challe...Output-only structural identification is developed by a refined Frequency Domain Decomposition(rFDD) approach, towards assessing current modal properties of heavy-damped buildings(in terms of identification challenge), under strong ground motions. Structural responses from earthquake excitations are taken as input signals for the identification algorithm. A new dedicated computational procedure, based on coupled Chebyshev Type Ⅱ bandpass filters, is outlined for the effective estimation of natural frequencies, mode shapes and modal damping ratios. The identification technique is also coupled with a Gabor Wavelet Transform, resulting in an effective and self-contained time-frequency analysis framework. Simulated response signals generated by shear-type frames(with variable structural features) are used as a necessary validation condition. In this context use is made of a complete set of seismic records taken from the FEMA P695 database, i.e. all 44 "Far-Field"(22 NS, 22 WE) earthquake signals. The modal estimates are statistically compared to their target values, proving the accuracy of the developed algorithm in providing prompt and accurate estimates of all current strong ground motion modal parameters. At this stage, such analysis tool may be employed for convenient application in the realm of Earthquake Engineering, towards potential Structural Health Monitoring and damage detection purposes.展开更多
基金Project(51221462)supported by the National Natural Science Foundation of ChinaProject(20120095110001)supported by the PhD Programs Foundation of Ministry of Education of ChinaProject(CXZZ13_0927)supported by Research and Innovation Project for College Graduates of Jiangsu Province,China
文摘As the stiffness of the elastic support varies with the physical-chemical erosion and mechanical friction, model catastrophe of a single degree-of-freedom(DOF) isolation system may occur. A 3-DOF four-point-elastic-support rigid plate(FERP) structure is presented to describe the catastrophic isolation system. Based on the newly-established structure, theoretical derivation for stiffness matrix calculation by free response(SMCby FR) and the method of stiffness identification by stiffness matrix disassembly(SIby SMD)are proposed. By integrating the SMCby FR and the SIby SMD and defining the stiffness assurance criterion(SAC), the procedures for stiffness identification of a FERP structure(SIFERP) are summarized. Then, a numerical example is adopted for the SIFERP validation, in which the simulated tested free response data are generated by the numerical methods, and operation for filtering noise is conducted to imitate the practical application. Results in the numerical example demonstrate the feasibility and accuracy of the developed SIFERP for stiffness identification.
基金Public research funding from“Fondi di Ricerca d’Ateneo ex 60%” and a ministerial doctoral grantfunds at the ISA Doctoral School,University of Bergamo,Department of Engineering and Applied Sciences (Dalmine)
文摘Output-only structural identification is developed by a refined Frequency Domain Decomposition(rFDD) approach, towards assessing current modal properties of heavy-damped buildings(in terms of identification challenge), under strong ground motions. Structural responses from earthquake excitations are taken as input signals for the identification algorithm. A new dedicated computational procedure, based on coupled Chebyshev Type Ⅱ bandpass filters, is outlined for the effective estimation of natural frequencies, mode shapes and modal damping ratios. The identification technique is also coupled with a Gabor Wavelet Transform, resulting in an effective and self-contained time-frequency analysis framework. Simulated response signals generated by shear-type frames(with variable structural features) are used as a necessary validation condition. In this context use is made of a complete set of seismic records taken from the FEMA P695 database, i.e. all 44 "Far-Field"(22 NS, 22 WE) earthquake signals. The modal estimates are statistically compared to their target values, proving the accuracy of the developed algorithm in providing prompt and accurate estimates of all current strong ground motion modal parameters. At this stage, such analysis tool may be employed for convenient application in the realm of Earthquake Engineering, towards potential Structural Health Monitoring and damage detection purposes.