An optical sensor for hydrogen sulfide detection in open path using WMS-2f/1f technique 被引量:2
1
作者 宋丽梅 刘力文 +2 位作者 杨燕罡 郭庆华 习江涛 《Optoelectronics Letters》 EI 2016年第6期465-468,共4页
An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) la... An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H_2S line at 6 336.62 cm^(-1) in the fundamental absorption band of H_2S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2f/1f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s(in concentration range of 15.2—45.6 mg/m^3), respectively. The maximum relative deviation for continuous detection(60 min) of 30.4 mg/m^3 H_2S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m^3 with optimal integration time of 32 s. The optical H_2S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields. 展开更多
关键词 corrected sulfide deviation Allan reflecting harmonic targeting drift linearity length
原文传递
A near-infrared methane detection system using a 1.654 μm wavelength-modulated diode laser 被引量:1
2
作者 付洋 刘慧芳 +4 位作者 隋越 李彬 叶玮琳 郑传涛 王一丁 《Optoelectronics Letters》 EI 2016年第2期140-143,共4页
By adopting a distributed feedback laser(DFBL) centered at 1.654 μm, a near-infrared(NIR) methane(CH4) detection system based on tunable diode laser absorption spectroscopy(TDLAS) is experimentally demonstrated. A la... By adopting a distributed feedback laser(DFBL) centered at 1.654 μm, a near-infrared(NIR) methane(CH4) detection system based on tunable diode laser absorption spectroscopy(TDLAS) is experimentally demonstrated. A laser temperature control as well as wavelength modulation module is developed to control the laser's operation temperature. The laser's temperature fluctuation can be limited within the range of-0.02—0.02 °C, and the laser's emitting wavelength varies linearly with the temperature and injection current. An open reflective gas sensing probe is realized to double the absorption optical path length from 0.2 m to 0.4 m. Within the detection range of 0—0.01, gas detection experiments were conducted to derive the relation between harmonic amplitude and gas concentration. Based on the Allan deviation at an integral time of 1 s, the limit of detection(Lo D) is decided to be 2.952×10^(-5) with a path length of 0.4 m, indicating a minimum detectable column density of ~1.2×10^(-5) m. Compared with our previously reported NIR CH_4 detection system, this system exhibits some improvement in both optical and electrical structures, including the analogue temperature controller with less software consumption, simple and reliable open reflective sensing probe. 展开更多
关键词 reflective deviation methane modulated Allan tunable analogue fluctuation decided length
原文传递
Autonomous vicarious calibration based on automated test-site radiometer 被引量:2
3
作者 邱刚刚 李新 +2 位作者 郑小兵 闫静 孙彦港 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第12期70-74,共5页
We employ the in-site automated observation radiometric calibration(AORC) approach to perform vicarious calibration, which does not require the manual efforts of a field team to measure the surface conditions. By us... We employ the in-site automated observation radiometric calibration(AORC) approach to perform vicarious calibration, which does not require the manual efforts of a field team to measure the surface conditions. By using an automated test-site radiometer(ATR), the surface radiance at any moment in time can be obtained. This Letter describes the AORC approach and makes use of data to compute top-of-atmosphere radiance and compare it to measurements from the Moderate Resolution Imaging Spectroradiometer. The result shows that the relative deviation is less than 5% and the uncertainty is less than 6.2%, which indicates that the in-site AORC maintains an accuracy level on par with traditional calibration. 展开更多
关键词 calibration radiometer automated manual compute viewing reflectance deviation correction directional