期刊文献+
共找到32篇文章
< 1 2 >
每页显示 20 50 100
A Method of Identifying Electromagnetic Radiation Sources by Using Support Vector Machines 被引量:2
1
作者 石丹 高攸纲 《China Communications》 SCIE CSCD 2013年第7期36-43,共8页
Electromagnetic Radiation Source Identification(ERSI) is a key technology that is widely used in military and radiation management and in electromagnetic interference diagnostics.The discriminative capability of machi... Electromagnetic Radiation Source Identification(ERSI) is a key technology that is widely used in military and radiation management and in electromagnetic interference diagnostics.The discriminative capability of machine learning methods has recently been used for facilitating ERSI.This paper presents a new approach to improve ERSI by adopting support vector machines,which are proven to be effective tools in pattern classification and regression,on the basis of the spatial distribution of electromagnetic radiation sources.Spatial information is converted from 3D cubes to 1D vectors with subscripts as inputs in order to simplify the model.The model is trained with 187 500 data sets in order to enable it to identify the types of radiation source types with an accuracy of up to 99.9%.The influence of parameters(e.g.,penalty parameter,reflection and noise from the ambient environment,and the scaling method for the input data) are discussed.The proposed method has good performance in noisy and reverberant environment.It has an identification accuracy of 82.15% when the signal-to-noise ratio is 20 dB.The proposed method has better accuracy in a noisy environment than artificial neural networks.Given that each Electromagnetic(EM) source has unique spatial characteristics,this method can be used for EM source identification and EM interference diagnostics. 展开更多
关键词 support vector machines electro- magnetic radiation sources spatial characteistics IDENTIFICATION
在线阅读 下载PDF
Automatic modulation recognition of radiation source signals based on two-dimensional data matrix and improved residual neural network 被引量:1
2
作者 Guanghua Yi Xinhong Hao +3 位作者 Xiaopeng Yan Jian Dai Yangtian Liu Yanwen Han 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第3期364-373,共10页
Automatic modulation recognition(AMR)of radiation source signals is a research focus in the field of cognitive radio.However,the AMR of radiation source signals at low SNRs still faces a great challenge.Therefore,the ... Automatic modulation recognition(AMR)of radiation source signals is a research focus in the field of cognitive radio.However,the AMR of radiation source signals at low SNRs still faces a great challenge.Therefore,the AMR method of radiation source signals based on two-dimensional data matrix and improved residual neural network is proposed in this paper.First,the time series of the radiation source signals are reconstructed into two-dimensional data matrix,which greatly simplifies the signal preprocessing process.Second,the depthwise convolution and large-size convolutional kernels based residual neural network(DLRNet)is proposed to improve the feature extraction capability of the AMR model.Finally,the model performs feature extraction and classification on the two-dimensional data matrix to obtain the recognition vector that represents the signal modulation type.Theoretical analysis and simulation results show that the AMR method based on two-dimensional data matrix and improved residual network can significantly improve the accuracy of the AMR method.The recognition accuracy of the proposed method maintains a high level greater than 90% even at -14 dB SNR. 展开更多
关键词 Automatic modulation recognition radiation source signals Two-dimensional data matrix Residual neural network Depthwise convolution
在线阅读 下载PDF
Experimental Study of the X-Ray Radiation Source at Approximately Constant Radiation Temperature 被引量:1
3
作者 宋天明 杨家敏 +2 位作者 杨冬 李志超 尚万里 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1108-1111,共4页
An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the... An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and 展开更多
关键词 X-ray radiation source laser pulse shaping power balance
在线阅读 下载PDF
Compact Z-pinch radiation source dedicated to broadband absorption measurements 被引量:1
4
作者 Dunpin Hong Herve Rabat +2 位作者 Erwan Le Menn Clement Zaepffel Jean-Marc Bauchire 《Matter and Radiation at Extremes》 SCIE EI CAS 2016年第3期179-186,共8页
In order to acquire a broadband absorption spectrum in a single shot,a compact radiation source was developed by using a Z-pinch type electric discharge.This paper presents the mechanical and electrical construction o... In order to acquire a broadband absorption spectrum in a single shot,a compact radiation source was developed by using a Z-pinch type electric discharge.This paper presents the mechanical and electrical construction of the source,as well as its electrical and optical characteristics,including the intense continuum of radiation emitted by the source in the UV and visible spectral range.It also shows that the compactness of the source allows direct coupling with the probed medium,enabling broadband absorption measurement in the spectral range of 200e300 nm without use of an optical fiber which strongly attenuates the light in the short wavelength range.Concretely,thanks to this source,broadband spectral absorption of NO molecules around 210 nm and that of OH molecules around 310 nm were recorded in this direct coupling arrangement.Copper atom spectral absorption around 325 nm of the peripheral cold zones of an intense transient arc was also recorded. 展开更多
关键词 Z-PINCH Broadband radiation source Broadband absorption spectrum
在线阅读 下载PDF
A novel approach for unlabeled samples in radiation source identification
5
作者 YANG Haifen ZHANG Hao +1 位作者 WANG Houjun GUO Zhengyang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2022年第2期354-359,共6页
Radiation source identification plays an important role in non-cooperative communication scene and numerous methods have been proposed in this field. Deep learning has gained popularity in a variety of computer vision... Radiation source identification plays an important role in non-cooperative communication scene and numerous methods have been proposed in this field. Deep learning has gained popularity in a variety of computer vision tasks. Recently, it has also been successfully applied for radiation source identification.However, training deep neural networks for classification requires a large number of labeled samples, and in non-cooperative applications, it is unrealistic. This paper proposes a method for the unlabeled samples of unknown radiation source. It uses semi-supervised learning to detect unlabeled samples and label new samples automatically. It avoids retraining the neural network with parameter-transfer learning. The results show that compared with the traditional algorithms, the proposed algorithm can offer better accuracy. 展开更多
关键词 radiation source identification deep learning semisupervised learning
在线阅读 下载PDF
Bernoulli particle flter with observer altitude for maritime radiation source tracking in the presence of measurement uncertainty
6
作者 Luo Xiaobo Fan Hongqi +1 位作者 Song Zhiyong Fu Qiang 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第6期1459-1470,共12页
For maritime radiation source target tracking in particular electronic counter measures(ECM)environment,there exists two main problems which can deteriorate the tracking performance of traditional approaches.The frs... For maritime radiation source target tracking in particular electronic counter measures(ECM)environment,there exists two main problems which can deteriorate the tracking performance of traditional approaches.The frst problem is the poor observability of the radiation source.The second one is the measurement uncertainty which includes the uncertainty of the target appearing/disappearing and the detection uncertainty(false and missed detections).A novel approach is proposed in this paper for tracking maritime radiation source in the presence of measurement uncertainty.To solve the poor observability of maritime radiation source target,using the radiation source motion restriction,the observer altitude information is incorporated into the bearings-only tracking(BOT)method to obtain the unique target localization.Then the two uncertainties in the ECM environment are modeled by the random fnite set(RFS)theory and the Bernoulli fltering method with the observer altitude is adopted to solve the tracking problem of maritime radiation source in such context.Simulation experiments verify the validity of the proposed approach for tracking maritime radiation source,and also demonstrate the superiority of the method compared with the traditional integrated probabilistic data association(IPDA)method.The tracking performance under different conditions,particularly those involving different duration of radiation source opening and switching-off,indicates that the method to solve our problem is robust and effective. 展开更多
关键词 Bernoulli flter Maritime radiation source Measurement uncertainty Passive tracking Random fnite set
原文传递
Continued Study on Hohlraum Radiation Source with Approximately Constant Radiation Temperature
7
作者 宋天明 杨家敏 +2 位作者 朱托 李志超 黄成武 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第4期342-345,共4页
An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A ... An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A radiation source with a flattop temperature of about130 e V that lasted about 5 ns was obtained.The previous analytical iteration method based on power balance and self-similar solution of ablation was modified taking into account the plasma movements and it was used to design the laser pulse shape for experiment.A comparison between experimental results and simulation is presented and better agreement was achieved using the modified method.Further improvements are discussed. 展开更多
关键词 X-ray radiation source laser pulse shaping power balance
在线阅读 下载PDF
3D Spectrum Mapping and Reconstruction Under Multi-Radiation Source Scenarios
8
作者 Wang Jie Lin Zhipeng +5 位作者 Zhu Qiuming Wu Qihui Lan Tianxu Zhao Yi Bai Yunpeng Zhong Weizhi 《China Communications》 2026年第2期20-34,共15页
Spectrum map construction,which is crucial in cognitive radio(CR)system,visualizes the invisible space of the electromagnetic spectrum for spectrum-resource management and allocation.Traditional reconstruction methods... Spectrum map construction,which is crucial in cognitive radio(CR)system,visualizes the invisible space of the electromagnetic spectrum for spectrum-resource management and allocation.Traditional reconstruction methods are generally for twodimensional(2D)spectrum map and driven by abundant sampling data.In this paper,we propose a data-model-knowledge-driven reconstruction scheme to construct the three-dimensional(3D)spectrum map under multi-radiation source scenarios.We firstly design a maximum and minimum path loss difference(MMPLD)clustering algorithm to detect the number of radiation sources in a 3D space.Then,we develop a joint location-power estimation method based on the heuristic population evolutionary optimization algorithm.Considering the variation of electromagnetic environment,we self-learn the path loss(PL)model based on the sampling data.Finally,the 3D spectrum is reconstructed according to the self-learned PL model and the extracted knowledge of radiation sources.Simulations show that the proposed 3D spectrum map reconstruction scheme not only has splendid adaptability to the environment,but also achieves high spectrum construction accuracy even when the sampling rate is very low. 展开更多
关键词 cognitive radio map reconstruction path loss model radiation source 3D spectrum map
在线阅读 下载PDF
Numerical Simulation of a Hybrid Undulator Applied in THz Radiation Source 被引量:1
9
作者 秦斌 熊永前 +2 位作者 谭萍 裴元吉 樊明武 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第z1期253-255,共3页
The undulator is the key component in the compact THz radiation source based on FEL.By matching the adjustable period magnetic field of the undulator with the optical resonance cavity,the passing electron beam will ge... The undulator is the key component in the compact THz radiation source based on FEL.By matching the adjustable period magnetic field of the undulator with the optical resonance cavity,the passing electron beam will generate coherent radiation with gain,and the radiation power required by THz source can be achieved finally. Compared with the pure permanent magnet type,the hybrid type undulator can decrease the field errors caused by non-homogeneous magnetization of magnetic blocks,and provide higher magnetic field.The conceptual design of a hybrid undulator used for THz radiation source is introduced.We use the FEM code OPERA/TOSCA to simulate 3D magnetic field of the undulator.After optimizing the end structure of the hybrid undulator,the first field integrals is controlled within 0.01Gs.m,and the deviation of the electron beam is less than 0.02mm. 展开更多
关键词 THz radiation source hybrid undulator numerical simulation TOSCA
原文传递
An orientation method and analysis of optical radiation sources based on polyhedron and parallel incident light 被引量:1
10
作者 WANG Jiang 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第2期475-483,共9页
The spatial orientation of optical radiation sources has long been the hot topic in the aerospace and the military applications.Current researches mainly focus on the high precision orientation on the partial field of... The spatial orientation of optical radiation sources has long been the hot topic in the aerospace and the military applications.Current researches mainly focus on the high precision orientation on the partial field of view.Thus,combination of several partial fields of view is required to achieve orientation when the field of view exceeds 180°,which results in the increase of size,weight,power consumption and the cost.By defining radiation energy and direction of the optical radiation source as a vector and applying the cosine law of radiation and vector theorem,it is shown that the vector can be obtained from unit normal vectors on the three un-coplanar surfaces and from the energy projected by the optical radiation source.Based on this,an orientation method with 360° full field of view by a polyhedron is suggested,the mathematical formula for anti-multipath interference is supposed and the error upper limit is derived.The feasibility and effectiveness of this method are validated by measurements and simulation.An accuracy better than 2.866° and 0.574° is achieved when the ratio of measurement error of energy on arbitrary surface and the true value are 5% and 1%,respectively,given the matrix composed of unit normal vectors on three measurement surfaces is orthogonal. 展开更多
关键词 optical radiation sources orientation radiation energy unit normal vector POLYHEDRON
原文传递
Equivalent radiation source of 3D package for electromagnetic characteristics analysis
11
作者 Jun Li Xingchang Wei Yufei Shu 《Journal of Semiconductors》 EI CAS CSCD 2017年第10期101-106,共6页
An equivalent radiation source method is proposed to characterize electromagnetic emission and interference of complex three dimensional integrated circuits(IC) in this paper.The method utilizes amplitude-only near-... An equivalent radiation source method is proposed to characterize electromagnetic emission and interference of complex three dimensional integrated circuits(IC) in this paper.The method utilizes amplitude-only near-field scanning data to reconstruct an equivalent magnetic dipole array,and the differential evolution optimization algorithm is proposed to extract the locations,orientation and moments of those dipoles.By importing the equivalent dipoles model into a 3D full-wave simulator together with the victim circuit model,the electromagnetic interference issues in mixed RF/digital systems can be well predicted.A commercial IC is used to validate the accuracy and efficiency of this proposed method.The coupled power at the victim antenna port calculated by the equivalent radiation source is compared with the measured data.Good consistency is obtained which confirms the validity and efficiency of the method. 展开更多
关键词 equivalent radiation source three dimensional integrated circuits amplitude-only magnetic dipole array differential evolution
原文传递
Application of Transient Electromagnetic Method with Multi-Radiation Field Sources in Deep Edge Mineral Resources Exploration 被引量:2
12
作者 ZENG Youqiang ZENG Gaofu +3 位作者 HUANG Lishan LI Xiu GUO Jianlei WANG Jianchao 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2021年第S01期99-101,共3页
In recent years,in order to meet the practical needs of deep edge mine detection with large depth and high precision,transient electromagnetic method(TEM)near emission source detection mode has become an international... In recent years,in order to meet the practical needs of deep edge mine detection with large depth and high precision,transient electromagnetic method(TEM)near emission source detection mode has become an international advanced method(Xue et al.,2020). 展开更多
关键词 multiple radiation field sources exploration of deep mineral resources transient electromagnetic method
在线阅读 下载PDF
Sources of IR Radiation in the Earth’s Atmosphere in Connection with the PeTa Effect
13
作者 Vitali A. Tatartchenko 《Optics and Photonics Journal》 2021年第6期152-196,共45页
The PeTa (Perelman-Tatartchenko) effect is the radiation of the energy of a first-order phase transition during the transition from a less condensed phase to a more condensed one. The effect was independently discover... The PeTa (Perelman-Tatartchenko) effect is the radiation of the energy of a first-order phase transition during the transition from a less condensed phase to a more condensed one. The effect was independently discovered by M. Perelman and the author of this paper. Six papers on the PeTa effect have been published in this journal over the past nine years. They are devoted to the development of PeTa models to explain the following phenomena: IR radiation from cold surfaces, cavitation luminescence/sonoluminescence (CL/SL), laser-induced bubble luminescence (LIBL), and vapor bubble luminescence (VBL) in underwater geysers. This paper describes the sources of PeTa radiation in the Earth’s atmosphere. These sources of infrared radiation have been investigated by numerous research groups, but their interpretation either does not exist at all, or it is erroneous. The following phenomena are specifically considered: PeTa radiation during the formation of clouds and fog;a pulse laser based on the PeTa radiation;condensation explosions as sources of PaTa radiation;measurement of the concentration of water vapor in the atmosphere using PeTa radiation;atmospheric scintillation of infrared radiation in the atmosphere due to the PeTa effect;PeTa radiation as a source of comfort for the igloo;the influence of PeTa radiation on living organisms;PeTa radiation due to characteristics of tropical storms;PeTa radiation as a possible precursor to earthquakes. The problem of global warming, which worries everyone, as it turns out, is also associated with the PeTa effect. 展开更多
关键词 PeTa (Perelman-Tatartchenko) Effect sources of PeTa radiation in the Earth’s Atmosphere Pulse IR Laser Condensation Explosions Atmospheric IR Scintillations Tropical Storms EARTHQUAKES Global Warming
在线阅读 下载PDF
Real-time visualization and numerical investigation of the dynamic compression response behaviours of single AP/HMX particles embedded in an HTPB binder
14
作者 Yiming Zhang Hanqing Xia +4 位作者 Kangyu Ji Ningfei Wang Ke Li Sen Chen Yi Wu 《Defence Technology(防务技术)》 2026年第2期254-269,共16页
An in-depth understanding of the behaviours of solid propellants under low-velocity impact loads is crucial for enhancing their safety in applications such as aerospace propulsion.This study investigated the dynamic r... An in-depth understanding of the behaviours of solid propellants under low-velocity impact loads is crucial for enhancing their safety in applications such as aerospace propulsion.This study investigated the dynamic responses of single ammonium perchlorate(AP)/octogen(HMX)particles embedded in a hydroxyl-terminated polybutadiene(HTPB)binder under dynamic compression loading via real-time synchrotron-based X-ray phase contrast imaging and a modified split Hopkinson pressure bar(SHPB)system.The compression of the viscoelastic binder and subsequent dynamic fracturing of the AP/HMX particles were captured.During compression,transverse cracks developed within the AP particles,and their propagation led to particle fracturing,resulting in ductile fracturing.Unlike AP,HMX generated numerous short cracks within the internal and edge regions simultaneously,leading to fragmentation and brittle fracturing.Moreover,particle damage reduced the modulus of the sample,shifting its dynamic stress response from nonlinear elasticity to strain softening and further strain hardening as the binder exhibited plastic deformation.A compression simulation incorporating a real particle microscopic structure was established to study the mechanical response of the interface and particles.The simulation results agreed with the experimental observations.These results indicate that the shear stress at the HTPB-AP interface is greater than that at the HTPB-HMX interface,which is a factor influencing the differences in the mesoscale damage mechanisms of the particles. 展开更多
关键词 Synchrotron radiation source Dynamic compression Particle damage Microscopic simulation
在线阅读 下载PDF
Radiation Shielding Analysis for Pressurized Heavy Water Reactors (CANDU) Using MCNPX Code
15
作者 Afrah El-Khawlani Moustafa Aziz Ali Ellithi 《材料科学与工程(中英文B版)》 2022年第2期50-57,共8页
MCNPX(Monte Carlo N-Particle Transport Code)computer code is used to design a model to CANDU(Canada Deuterium Uranium)reactor core and its shielding system.It is assumed that reactor core is fueled with natural uraniu... MCNPX(Monte Carlo N-Particle Transport Code)computer code is used to design a model to CANDU(Canada Deuterium Uranium)reactor core and its shielding system.It is assumed that reactor core is fueled with natural uranium.The core radiation sources are calculated which consider prompt neutrons,neutron induced gamma and prompt gamma radiations.The total neutron flux and dose rate are calculated along the shield and at outer shield points.The results indicated that the major dose rate component at outer shield points is due to neutron induced gamma dose rate(μSv/h). 展开更多
关键词 CANDU reactor MCNPX code reactor shielding natural uranium radiation source
在线阅读 下载PDF
A closed-form solution for moving source localization using LBI changing rate of phase difference only 被引量:11
16
作者 Zhang Min Guo Fucheng Zhou Yiyu 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2014年第2期365-374,共10页
Due to the deficiencies in the conventional multiple-receiver localization syste,.ns based on direction of arrival (DOA) such as system complexity of interferometer or array and ampli- tude/phase unbalance between m... Due to the deficiencies in the conventional multiple-receiver localization syste,.ns based on direction of arrival (DOA) such as system complexity of interferometer or array and ampli- tude/phase unbalance between multiple receiving channels and constraint on antenna configuration, a new radiated source localization method using the changing rate of phase difference (CRPD) measured by a long baseline interferometer (LBI) only is studied. To solve the strictly nonlinear problem, a two-stage closed-form solution is proposed. In the first stage, the DOA and its changing rate are estimated from the CRPD of each observer by the pseudolinear least square (PLS) method, and then in the second stage, the source position and velocity are found by another PLS minimiza- tion. The bias of the algorithm caused by the correlation between the measurement matrix and the noise in the second stage is analyzed. To reduce this bias, an instrumental variable (IV) method is derived. A weighted IV estimator is given in order to reduce the estimation variance. The proposed method does not need any initial guess and the computation is small. The Cramer-Rao lower bound (CRLB) and mean square error (MSE) are also analyzed. Simulation results show that the proposed method can be close to the CRLB with moderate Gaussian measurement noise. 展开更多
关键词 Changing rate of phase dif-ference Cramer-Rao lower bound Estimation bias Instrumental variable Least square Long baseline interferome-ter Radiated source localization
原文传递
SWELLING BEHAVIOR OF ACRYLAMIDE HYDROGEL IN DIFFERENT SOLVENTS AND pHs 被引量:7
17
作者 M.F.Mina M.M.Alam 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2005年第3期269-274,共6页
Swelling property of acrylamide hydrogels,prepared from aqueous solutions of acrylamide monomer havingconcentrations in the range of 10-60 wt% by ray irradiation method using a Co-60 gamma radiation source at dosesran... Swelling property of acrylamide hydrogels,prepared from aqueous solutions of acrylamide monomer havingconcentrations in the range of 10-60 wt% by ray irradiation method using a Co-60 gamma radiation source at dosesranging 1-30.0 kGy,has been investigated under various swelling media.These swelling media were basically solvents(solutions),produced by dissolving methanol,ethanol,glucose,sucrose,sodium chloride and sodium persulfate individuallywith distilled water,and solutions prepared with pHs=3,7 and 10.The investigation was performed in order to observe theeffect of these solvents and pHs as well as the influence of monomer concentrations,radiation doses and times on swellingbehavior of hydrogels.Swelling values were found higher for hydrogels prepared with lower monomer concentrations(ca.20 wt%)and radiation doses(ca.5 kGy)and showed a leveling off tendency within 24 h.The glucose solvent and the buffersolution of pH=10 revealed significant increase of swelling of hydrogels as compared to other solutions.Results areexplained based on crosslinking density in hydrogel,polymer-solvent/polymer-polymer interactions in solutions,permeability of molecules in solutions and ionization capacity of hydrogel in pH. 展开更多
关键词 ACRYLAMIDE HYDROGEL Co-60 gamma radiation source Swelling.
在线阅读 下载PDF
Penetrating view of nano-structures in Aleochara verna spermatheca and flagellum by hard X-ray microscopy 被引量:2
18
作者 张凯 李德娥 +6 位作者 洪友丽 朱佩平 袁清习 黄万霞 高昆 周红章 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期410-414,共5页
A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast... A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast noninvasive imaging technology for insect morphology. Through introducing Zernike phase contrast and heavy metal staining, images taken at 8 keV displayed sufficient contrast for observing nanoscale fine structures, such as the spermatheca cochleate duct and the subapex of the flagellum, which have some implications for the study of the sperm transfer process and genital evolution in insects. This work shows that both the spatial resolution and the contrast characteristic of hard X-ray microscopy are quite promising for insect morphology studies and, particularly, provide an attractive alternative to the destructive techniques used for investigating internal soft tissues. 展开更多
关键词 X-ray microscopy computed tomography synchrotron radiation source morphology
原文传递
Ultra Fast Shutter Driven by Pulsed High Current 被引量:2
19
作者 曾江涛 孙凤举 +3 位作者 邱爱慈 尹佳辉 郭建明 陈玉兰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第2期2781-2784,共4页
Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high curr... Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90 kA to140 kA and discharging current periods of approximately 13.1μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities. 展开更多
关键词 plasma radiation source (PRS) ultra fast shutter pulsed high current
在线阅读 下载PDF
Investigation of Vacuum Ultraviolet Photoionization of Methylcyclohexane in Energy Region of 9-15.5 eV 被引量:1
20
作者 Hang Zhang Yan-bo Li +7 位作者 Long Zhu Jun Chen Ye-peng Yu Zhao-hui Li Xuan Lin Xiao-bin Shan Fu-yi Liu Liu-si Sheng 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2020年第3期296-302,I0002,共8页
Vacuum ultraviolet(VUV)photoionization and photodissociation of methylcyclohexane have been studied utilizing a reflectron time-of-flight mass spectrometer(RTOF-MS)with synchrotron radiation source.Photoionization eff... Vacuum ultraviolet(VUV)photoionization and photodissociation of methylcyclohexane have been studied utilizing a reflectron time-of-flight mass spectrometer(RTOF-MS)with synchrotron radiation source.Photoionization efficiency curves(PIEs)of molecule ion C7H14^+ and fragment ions C7H13^+,C6H11^+,C6H10+,C5H10^+,C5H9^+,C4H8^+,C4H7^+,and C3H5^+ were observed.The ionization energy of methylcyclohexane was measured to be(9.80±0.03)eV,and appearance energies of fragment ions were determined from the PIEs.Optimized structures of transitional states,intermediates and product ions were characterized at the B3LYP/6-31G(d)level and the energies were calculated using G3B3 method.Formation channels of dominating fragment ions were proposed.Intramolecular hydrogen migrations and carbon ring-opening were the foremost processes in fragmentation pathways of methylcyclohexane. 展开更多
关键词 METHYLCYCLOHEXANE Photoionization and photodissociation Synchrotron radiation source Reflectron time-of-flight mass spectrometer
在线阅读 下载PDF