The jacking pinions and rack chocks of the fixation system of a jack-up sustain tremendous load in the elevated condition, especially when there exists a remarkable non-uniformity of the load distribution. Failures of...The jacking pinions and rack chocks of the fixation system of a jack-up sustain tremendous load in the elevated condition, especially when there exists a remarkable non-uniformity of the load distribution. Failures of these structural components may lead to disastrous consequence of the jack-up. Despite the importance of these components, it is difficult to give an accurate prediction of the load distribution on these components in engineering application due to the complex nonlinear interaction mechanism, which is influenced by the relative stiffness of the components, leg-guide clearance and backlash. Previous studies mainly focus on the global performance of the jack-up and pay little attention to the load distribution on the pinions and chocks. The strength of the jacking system is often guaranteed by the manufacturer for an estimate load level, which brings in uncertainty to the safety of the jack-up. The characteristics of the hull-leg interaction are discussed in this paper, and a simplified method using gap elements is proposed. The nonlinear structural analyses are carried out for a specific jack-up using the proposed method and the three-dimensional finite element method(FEM) with contact algorithm. The proposed method is proved accurate and effective for the engineering application. The characteristics of the load distribution of the specific jack-up are discussed, and the conclusions are presented.展开更多
Large-module rack of the Three Gorges shiplift is manufactured by casting and machining, which is unable to avoid slag inclusions and surface cracks. To ensure its safety in the future service, studying on crack propa...Large-module rack of the Three Gorges shiplift is manufactured by casting and machining, which is unable to avoid slag inclusions and surface cracks. To ensure its safety in the future service, studying on crack propagation rule and the residual life estimation method of large-module rack is of great significance. The possible crack distribution forms of the rack in the Three Gorges shiplift were studied. By applying moving load on the model in FRANC3 D and ANSYS, quantitative analyses of interference effects on double cracks in both collinear and offset conditions were conducted. The variation rule of the stress intensity factor(SIF) influence factor, RK, of double collinear cracks changing with crack spacing ratio, RS, was researched. The horizontal and vertical crack spacing threshold of double cracks within the design life of the shiplift were obtained, which are 24 and 4 times as large as half of initial crack length, c0, respectively. The crack growth rates along the length and depth directions in the process of coalescence on double collinear cracks were also studied.展开更多
This paper discusses the performance of a proposed panelized brick veneer over steel stud backup wall system and seismic isolation connections under lateral loads. The panelized wall system was developed to address so...This paper discusses the performance of a proposed panelized brick veneer over steel stud backup wall system and seismic isolation connections under lateral loads. The panelized wall system was developed to address some shortcomings of the conventional brick veneer wall type. The details of the system are briefly introduced. The study evaluated the performance of the system under out-of-plane simulated wind loads and in-plane cyclic loads using full-scale laboratory experiments. The test setup, test specimen, test procedure, and test results are presented and the performance of the system is evaluated accordingly.展开更多
文摘The jacking pinions and rack chocks of the fixation system of a jack-up sustain tremendous load in the elevated condition, especially when there exists a remarkable non-uniformity of the load distribution. Failures of these structural components may lead to disastrous consequence of the jack-up. Despite the importance of these components, it is difficult to give an accurate prediction of the load distribution on these components in engineering application due to the complex nonlinear interaction mechanism, which is influenced by the relative stiffness of the components, leg-guide clearance and backlash. Previous studies mainly focus on the global performance of the jack-up and pay little attention to the load distribution on the pinions and chocks. The strength of the jacking system is often guaranteed by the manufacturer for an estimate load level, which brings in uncertainty to the safety of the jack-up. The characteristics of the hull-leg interaction are discussed in this paper, and a simplified method using gap elements is proposed. The nonlinear structural analyses are carried out for a specific jack-up using the proposed method and the three-dimensional finite element method(FEM) with contact algorithm. The proposed method is proved accurate and effective for the engineering application. The characteristics of the load distribution of the specific jack-up are discussed, and the conclusions are presented.
基金Project(0722018)supported by the China Three Gorges CorporationProject(2012KJX01)supported by the Hubei Key Laboratory of Hydroelectric Machinery Design&Maintenance,China
文摘Large-module rack of the Three Gorges shiplift is manufactured by casting and machining, which is unable to avoid slag inclusions and surface cracks. To ensure its safety in the future service, studying on crack propagation rule and the residual life estimation method of large-module rack is of great significance. The possible crack distribution forms of the rack in the Three Gorges shiplift were studied. By applying moving load on the model in FRANC3 D and ANSYS, quantitative analyses of interference effects on double cracks in both collinear and offset conditions were conducted. The variation rule of the stress intensity factor(SIF) influence factor, RK, of double collinear cracks changing with crack spacing ratio, RS, was researched. The horizontal and vertical crack spacing threshold of double cracks within the design life of the shiplift were obtained, which are 24 and 4 times as large as half of initial crack length, c0, respectively. The crack growth rates along the length and depth directions in the process of coalescence on double collinear cracks were also studied.
文摘This paper discusses the performance of a proposed panelized brick veneer over steel stud backup wall system and seismic isolation connections under lateral loads. The panelized wall system was developed to address some shortcomings of the conventional brick veneer wall type. The details of the system are briefly introduced. The study evaluated the performance of the system under out-of-plane simulated wind loads and in-plane cyclic loads using full-scale laboratory experiments. The test setup, test specimen, test procedure, and test results are presented and the performance of the system is evaluated accordingly.