基于运动过程中人体心、生理对运动负荷与强度的整体感知与反映,Rating of Perceived Exertion(RPE)量表用以预测机体最大摄氧量的信效度已得到众多实验研究的证实。但由于RPE值本身具有主观性,易受人群特征影响,因此,其利用RPE量表对...基于运动过程中人体心、生理对运动负荷与强度的整体感知与反映,Rating of Perceived Exertion(RPE)量表用以预测机体最大摄氧量的信效度已得到众多实验研究的证实。但由于RPE值本身具有主观性,易受人群特征影响,因此,其利用RPE量表对最大摄氧量的预测结果存在争议性。采用文献综述的方法,对现有研究中采用的RPE量表模式、实验对象、RPE6-20量表区段值与临界值、运动形式与负荷以及运动器材等方面予以概述和总结。建议:在扩大群体样本量的基础上,统一实验环境与实验程序,针对某一个或几个相似性因素群进行研究与验证;在实际应用过程中则应因人而异地选择和利用相应的程序、方法,建议与其它预测指标(如心率)相结合,以提高预测最大摄氧量的准确性。展开更多
Background:The validity and reliability of the Borg 6–20 rating of perceived exertion(RPE)scale has not been tested among Chinese people from China' Mainland.The purpose of this study was to test:1)The validity o...Background:The validity and reliability of the Borg 6–20 rating of perceived exertion(RPE)scale has not been tested among Chinese people from China' Mainland.The purpose of this study was to test:1)The validity of Leung Chinese version and Wang Chinese version of the Borg 6–20 RPE scale;2)The reliability of Wang Chinese version RPE scale;and 3)The agreement of these two Chinese versions of the RPE scale among young healthy adults from China' Mainland.Methods:A total of 26 subjects(11 males,15 females;age 22.7±3.0 yrs)volunteered to participate.They performed one(n=3),two(n=14),or three trials(n=9)of the Bruce treadmill protocol test within 9.0±5.1 days(validation trials),and 30.4±27.9 days(reliability trials).Power output,heart rate,oxygen consumption,and RPE were recorded.Results:RPE was significantly correlated with power output(Leung version rs≥0.75,Wang version rs≥0.73),heart rate(HR)(Leung version rs≥0.84,Wang version rs≥0.87),and oxygen consumption(VO2)(Leung version rs≥0.80,Wang version rs≥0.81)(all p<0.01).The overall test-retest interclass correlation was 0.94(p<0.01).No significant differences in correlations(RPE against power output,HR and VO_(2))between trials existed for the reliability tests of Wang version scale.No significant differences in correlations(RPE against power output,HR and VO_(2))between the two Chinese versions of RPE scale existed.Conclusion:Both Chinese RPE scales are valid among young healthy Chinese mandarin speaking adults.The Wang scale is reliable,and the Leung and Wang scales show superior agreement with each other.展开更多
文摘基于运动过程中人体心、生理对运动负荷与强度的整体感知与反映,Rating of Perceived Exertion(RPE)量表用以预测机体最大摄氧量的信效度已得到众多实验研究的证实。但由于RPE值本身具有主观性,易受人群特征影响,因此,其利用RPE量表对最大摄氧量的预测结果存在争议性。采用文献综述的方法,对现有研究中采用的RPE量表模式、实验对象、RPE6-20量表区段值与临界值、运动形式与负荷以及运动器材等方面予以概述和总结。建议:在扩大群体样本量的基础上,统一实验环境与实验程序,针对某一个或几个相似性因素群进行研究与验证;在实际应用过程中则应因人而异地选择和利用相应的程序、方法,建议与其它预测指标(如心率)相结合,以提高预测最大摄氧量的准确性。
文摘Background:The validity and reliability of the Borg 6–20 rating of perceived exertion(RPE)scale has not been tested among Chinese people from China' Mainland.The purpose of this study was to test:1)The validity of Leung Chinese version and Wang Chinese version of the Borg 6–20 RPE scale;2)The reliability of Wang Chinese version RPE scale;and 3)The agreement of these two Chinese versions of the RPE scale among young healthy adults from China' Mainland.Methods:A total of 26 subjects(11 males,15 females;age 22.7±3.0 yrs)volunteered to participate.They performed one(n=3),two(n=14),or three trials(n=9)of the Bruce treadmill protocol test within 9.0±5.1 days(validation trials),and 30.4±27.9 days(reliability trials).Power output,heart rate,oxygen consumption,and RPE were recorded.Results:RPE was significantly correlated with power output(Leung version rs≥0.75,Wang version rs≥0.73),heart rate(HR)(Leung version rs≥0.84,Wang version rs≥0.87),and oxygen consumption(VO2)(Leung version rs≥0.80,Wang version rs≥0.81)(all p<0.01).The overall test-retest interclass correlation was 0.94(p<0.01).No significant differences in correlations(RPE against power output,HR and VO_(2))between trials existed for the reliability tests of Wang version scale.No significant differences in correlations(RPE against power output,HR and VO_(2))between the two Chinese versions of RPE scale existed.Conclusion:Both Chinese RPE scales are valid among young healthy Chinese mandarin speaking adults.The Wang scale is reliable,and the Leung and Wang scales show superior agreement with each other.