期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
利用体表心电图校正QuickOpt^(TM)优化的房室间期 被引量:1
1
作者 张常莹 戴敏 +4 位作者 高运来 郑杰 刘晓宇 李库林 王如兴 《中国心脏起搏与心电生理杂志》 2013年第5期406-411,共6页
目的应用体表心电图观察QuickOptTM算法优化心脏再同步化治疗(CRT)中房室间期的准确性。方法 11例CRT患者,术后定期应用QuickOptTM算法优化,优化后检查12导联心电图及动态心电图,通过观察QRS波的时限、形态、向量,判断房室间期的设置是... 目的应用体表心电图观察QuickOptTM算法优化心脏再同步化治疗(CRT)中房室间期的准确性。方法 11例CRT患者,术后定期应用QuickOptTM算法优化,优化后检查12导联心电图及动态心电图,通过观察QRS波的时限、形态、向量,判断房室间期的设置是否准确以及左室起搏是否长期稳定、充分有效。结果 11例CRT患者中,8例经QuickOptTM算法优化后表现为长期稳定有效的双室起搏;2例经12导联心电图发现QuickOptTM算法推荐的房室间期偏长,因而左室起搏未能充分有效;1例经动态心电图发现自身PR间期间歇缩短至短于QuickOptTM算法推荐的房室间期、左室起搏不能长期稳定。结论 QuickOptTM算法简便、有效,但个别CRT患者QuickOptTM优化推荐的房室间期偏长,这时体表心电图是有效、便捷的检测、校正方法。 展开更多
关键词 心血管病学 心脏再同步化治疗 quickopttm 心腔内电图 心电图 房室间期
暂未订购
A prospective study to evaluate the efficacy of an intracardiac electrogram-based atrioventricular and interventricular intervals optimization method in cardiac resynchronization therapy 被引量:8
2
作者 Hua Wei Wang Dong-mei +16 位作者 Cai Lin Sun Chao-feng Fu Guo-sheng Wang Yu-tang Yan Ji Luo Zhi-ling Xu Jing Wang Zhi-yong Xu Geng Shen Fa-rong Xu Wei Wang Jing-feng Ren Xue-jun Jin Wei Zhang, Nan Lau, Elizabeth Oi-Yan Zhang Shu 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第3期428-433,共6页
Background Cardiac resynchronization therapy (CRT) with biventricular pacing improves cardiac function,functional capacity and quality of life in selected patients with heart failure.The current study aimed to evalu... Background Cardiac resynchronization therapy (CRT) with biventricular pacing improves cardiac function,functional capacity and quality of life in selected patients with heart failure.The current study aimed to evaluate the efficacy of the intracardiac electrogram (IEGM)-based optimization method,QuickOptTM,in Chinese patients treated with CRT.Methods Aortic time velocity integrals (AVTI) achieved at the sensed atrioventricular (AV),paced AV and interventricular (VV) interval settings recommended by both QuickOptTM and standard echocardiographic optimization were measured in 101 patients.Consistency and the strength of the relationship between the two timing cycle optimization methods were assessed by intra-class correlation coefficient (ICC).Results The ICC showed good agreement and correlation with what the AVTI achieved at the optimal sensed AV (ICC=0.9683 (0.9535-0.9785)),paced AV (ICC=0.9642 (0.9475-0.9757)) and VV (ICC=0.9730 (0.9602-0.9817)) interval settings determined by the two optimization methods.The average time required by echocardiographic optimization and by QuickOptTM were (78.32±32.40) minutes and (1.98±1.64) minutes respectively (P 〈0.0001).Conclusion The QuickOptTM algorithm provides a quicker,simpler and reliable alternative to the standard method for timing cycle optimization.(ClinicaITrial.gov Reference Number:NCT00918294) 展开更多
关键词 heart failure cardiac resynchronization therapy atrioventricular interval interventricular interval timing cycle optimization ECHOCARDIOGRAPHY aortic velocity time integral intracardiac electrogram quickopttm
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部