The two most important criteria for dental materials are their biofunctional and biocompatible endurance within the anticipated life-span of the dental restoration in the mouth. Biocompatibility relates mainly to the ...The two most important criteria for dental materials are their biofunctional and biocompatible endurance within the anticipated life-span of the dental restoration in the mouth. Biocompatibility relates mainly to the allergenicity and the toxicity of the material. To test the non-specific toxicity of dental materials, in vitro cell culture assays have been developed. For in vitro screening, such tests are recommended to check the cytotoxicity of dental materials (ISO 10993 5). Various studies have already been performed to quantitatively determine the cytotoxicity level of dental alloys. However, as long as only dental alloys and the cell culture technique are applied, it is not possible to determine which of the alloying elements cause the cytotoxicity. Therefore, an analytical method is needed. Wataha et al determined in 1991 the TC50 values of 9 metal cations of various dental casting alloys, using cell culture methods. Kapert et al reported in 1994 a complex in vitro test concept, where the ICP analysis (inductively coupled plasma emission spectroscopy) was introduced to measure the trace elements extracted from various alloys. Experimentelle Zahnheilkunde, Universitts ZMK Klinik Freiburg, Germany (Lü XY and Kappert HF) The aim of the present study was to find a relation between the ICP results, the TC50 value of metal cations, and the cytotoxicity of dental alloys. The cytotoxicity levels of various dental alloys and the TC50 values of 10 metal cations were established using the MTT assay, an effective cell culture of method. Then, the concentrations of the corrosively soluted metal cations in the extracts of the alloys were measured using the ICP method. From all these experimental results it was found that the relation between the effective cytotoxicity Z eff of an alloy, the concentrations C i of i th trace element and the TC50 values T Ci of the i th metal cation can approximately be expressed by Z eff =∑iC i2·T Ci . Two significant applications of this expression are a) The cytotoxicity of an alloy can be estimated by ICP analysis of the extract if the TC50 values of the trace elements are know. b) The cytotoxicity of a new-developed-alloy can be estimated in advance, according to the alloying components.展开更多
With the rapid development and wide application of traditional Chinese medicine injection(TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. ...With the rapid development and wide application of traditional Chinese medicine injection(TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. Establishing effective and practical analytical methods for safety evaluation and quality control of TCMI can help to improve the safety of TCMIs in clinical applications. In this study, a sensitive and rapid high-performance liquid chromatography–tandem mass spectrometry(HPLC–MS/MS)method has been developed and validated for the quantitative determination of potentially harmful substance5,5′-oxydimethylenebis(2-furfural, OMBF) in TCMI samples. Chromatographic separation was performed on a C18 reversed-phase column(150 mm × 2.1 mm, 5 μm) by gradient elution, using methanol–water containing 0.1% formic acid as mobile phase at the flow rate of 0.3 m L/min. MS/MS detection was performed on a triple quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction-monitoring mode. The method was sensitive with a limit of quantification of 0.3 ng/m L and linear over the range of 0.3–30 ng/m L(r = 0.9998). Intra-and inter-day precision for analyte was o9.52% RSD withrecoveries in the range 88.0–109.67% at three concentration levels. The validated method was successfully applied to quantitatively determine the compound OMBF in TCMIs and glucose injections. Our study indicates that this method is simple, sensitive, practicable and reliable, and could be applied for safety evaluation and quality control of TCMIs and glucose injections.展开更多
文摘The two most important criteria for dental materials are their biofunctional and biocompatible endurance within the anticipated life-span of the dental restoration in the mouth. Biocompatibility relates mainly to the allergenicity and the toxicity of the material. To test the non-specific toxicity of dental materials, in vitro cell culture assays have been developed. For in vitro screening, such tests are recommended to check the cytotoxicity of dental materials (ISO 10993 5). Various studies have already been performed to quantitatively determine the cytotoxicity level of dental alloys. However, as long as only dental alloys and the cell culture technique are applied, it is not possible to determine which of the alloying elements cause the cytotoxicity. Therefore, an analytical method is needed. Wataha et al determined in 1991 the TC50 values of 9 metal cations of various dental casting alloys, using cell culture methods. Kapert et al reported in 1994 a complex in vitro test concept, where the ICP analysis (inductively coupled plasma emission spectroscopy) was introduced to measure the trace elements extracted from various alloys. Experimentelle Zahnheilkunde, Universitts ZMK Klinik Freiburg, Germany (Lü XY and Kappert HF) The aim of the present study was to find a relation between the ICP results, the TC50 value of metal cations, and the cytotoxicity of dental alloys. The cytotoxicity levels of various dental alloys and the TC50 values of 10 metal cations were established using the MTT assay, an effective cell culture of method. Then, the concentrations of the corrosively soluted metal cations in the extracts of the alloys were measured using the ICP method. From all these experimental results it was found that the relation between the effective cytotoxicity Z eff of an alloy, the concentrations C i of i th trace element and the TC50 values T Ci of the i th metal cation can approximately be expressed by Z eff =∑iC i2·T Ci . Two significant applications of this expression are a) The cytotoxicity of an alloy can be estimated by ICP analysis of the extract if the TC50 values of the trace elements are know. b) The cytotoxicity of a new-developed-alloy can be estimated in advance, according to the alloying components.
基金supported by Chinese Academy of Medical Science (CAMS) Innovation Fund for Medical Sciences (Grant Nos. 2016-I2M-1–009 and 2016-I2M-3–010)National Scientific and Technological Major Project for New Drugs (Grant No. 2017ZX09101003-002-004)
文摘With the rapid development and wide application of traditional Chinese medicine injection(TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. Establishing effective and practical analytical methods for safety evaluation and quality control of TCMI can help to improve the safety of TCMIs in clinical applications. In this study, a sensitive and rapid high-performance liquid chromatography–tandem mass spectrometry(HPLC–MS/MS)method has been developed and validated for the quantitative determination of potentially harmful substance5,5′-oxydimethylenebis(2-furfural, OMBF) in TCMI samples. Chromatographic separation was performed on a C18 reversed-phase column(150 mm × 2.1 mm, 5 μm) by gradient elution, using methanol–water containing 0.1% formic acid as mobile phase at the flow rate of 0.3 m L/min. MS/MS detection was performed on a triple quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction-monitoring mode. The method was sensitive with a limit of quantification of 0.3 ng/m L and linear over the range of 0.3–30 ng/m L(r = 0.9998). Intra-and inter-day precision for analyte was o9.52% RSD withrecoveries in the range 88.0–109.67% at three concentration levels. The validated method was successfully applied to quantitatively determine the compound OMBF in TCMIs and glucose injections. Our study indicates that this method is simple, sensitive, practicable and reliable, and could be applied for safety evaluation and quality control of TCMIs and glucose injections.