期刊文献+
共找到3,039篇文章
< 1 2 152 >
每页显示 20 50 100
Pharmacological and light-driven pupillary accommodation in guinea pigs:comparative effects of muscarinic modulators and illumination across developmental stages
1
作者 Hao Wu Na Lu +5 位作者 Zhong-Bao Qiao Chi Cheng Wen-Ting Luo Ting Wan Tong Qiao Yue Di 《International Journal of Ophthalmology(English edition)》 2026年第2期211-218,共8页
AIM:To investigate the effects of different light intensities and various mydriatic and miotic drugs on pupil accommodation in guinea pigs.METHODS:Forty-two-week-old guinea pigs were randomly divided into four groups ... AIM:To investigate the effects of different light intensities and various mydriatic and miotic drugs on pupil accommodation in guinea pigs.METHODS:Forty-two-week-old guinea pigs were randomly divided into four groups to assess pupillary responses under varying light intensities(100,250,500 lx)and pharmacological interventions(1%atropine,1%cyclopentolate,1%tropicamide,or 2%pilocarpine).Baseline pupil size and eccentricity were recorded using a non-contact Python-based imaging system integrating edge detection and pixel-to-distance conversion.Direct illumination effects were measured at sequential time points,followed by drug administration and longitudinal tracking of pupillary changes.The protocol was repeated at 12wk of age for developmental comparisons.Postexperiment,enucleated eyes were analyzed to evaluate in vitro vs in vivo differences.RESULTS:Significant age-dependent differences in pupil dynamics were observed.Both 2-and 12-week-old guinea pigs exhibited marked pupil constriction under direct illumination(P<0.001),with decreased eccentricity post-constriction(P<0.001).Indirect illumination caused inconsistent pupil size changes(2-week:P=0.68;12-week:P=0.49).Pharmacologically,atropine,cyclopentolate,and tropicamide induced pupil dilation(P<0.001),whereas pilocarpine caused constriction(P<0.001).All drug groups showed reduced eccentricity(P<0.001).In vivo/in vitro comparisons revealed significant structural differences.CONCLUSION:This study investigates pupillary responses in developing guinea pigs,revealing a direct pupillary light reflex(PLR)with light intensity-dependent responses,while indirect PLR was undetectable.The differential effects of muscarinic modulators on pupillary responses underscore the critical role of cholinergic signaling in ocular accommodation,with age-related variations in sensitivity.Additionally,a novel non-contact measurement methodology achieved a precision of 0.01 mm for pupillary quantification,enhancing accuracy in ocular studies. 展开更多
关键词 pupil guinea pig muscarinic receptor modulator light reflex
原文传递
Different administration regimens of compound tropicamide eyedrops for pupil dilation for children with dark iris:a randomized clinical trial
2
作者 Xu Xu Lian-Xin Zhang Jing-Jing Jiang 《International Journal of Ophthalmology(English edition)》 2025年第3期415-419,共5页
AIM:To compare the efficacy of different administration regimens of compound tropicamide eyedrops(CTE)for pupil dilation for children with dark iris.METHODS:A prospective,comparative,randomized interventional study wa... AIM:To compare the efficacy of different administration regimens of compound tropicamide eyedrops(CTE)for pupil dilation for children with dark iris.METHODS:A prospective,comparative,randomized interventional study was conducted.Children in Group 1 received CTE 3 times with a 3min interval between each application.Children in Group 2 received CTE 4 times with a 5min interval between each application.We measured their pupil diameters at baseline(pre-drug instillation)and 30min and 60min post-drug instillation and assessed the pupillary light reflex at 60min post-drug instillation.RESULTS:In total,194 eyes of 101 children were enrolled.The changes of pupil diameter at 30min and 60min post-drug instillation were 1.2±0.6 mm and 2.3±1.0 mm in Group 1,and 2.3±0.9 mm and 3.7±1.0 mm in Group 2,respectively.Group 2 showed a larger change in pupil size than Group 1 at 30min(P<0.01)and 60min(P<0.01).The effect of pupil dilation in Group 2 was 1.25 times that in Group 1.The change in pupil size was positively associated with age.A higher proportion of children in Group 1 had smaller pupil diameter and reactive pupils at the final time point,with only 33 children(33.7%)had final pupil size≥6.5 mm,and only 9 children(9.2%)had non-reactive pupils.Children in Group 2 achieved larger pupil diameter and more nonreactive pupils at the final time point,with 84 children(87.5%)had final pupil size≥6.5 mm,and only 22 children(22.9%)had reactive pupils.CONCLUSION:Increasing the frequency of compound tropicamide and lengthening the interval between eye drop applications can produce stronger mydriatic effects. 展开更多
关键词 pupil dilation MYDRIASIS compound tropicamide dark iris CHILDREN
原文传递
Window to the soul:Pupil dynamics unveil the consolidation of recent and remote memories
3
作者 Hongyu Chang Wenbo Tang 《Zoological Research》 2025年第2期261-262,共2页
Memory enables organisms to encode,store,and retrieve information essential for interacting with and adapting to a dynamic environment.As an internal representation of the external world,memory serves as a crucial bri... Memory enables organisms to encode,store,and retrieve information essential for interacting with and adapting to a dynamic environment.As an internal representation of the external world,memory serves as a crucial bridge between past experiences and future behaviors.However,the brain continuously forms new memories,raising the question of how new memories are integrated without disrupting previously formed ones. 展开更多
关键词 recent memories previously formed ones memory brain interacting adapting CONSOLIDATION remote memories pupil dynamics
暂未订购
Effect of pharmacological pupil changes on intraocular lens power calculation:a systematic review and Metaanalysis
4
作者 Si-Yi Tan Dian-Feng Liu +1 位作者 Wei-Qi Wang Bing-Song Wang 《International Journal of Ophthalmology(English edition)》 2025年第3期518-525,共8页
AIM:To investigate the effect of pharmacological pupil alterations on intraocular lens(IOL)power calculations.METHODS:A systematic review and Meta-analysis of studies published before December 2023 in the PubMed,Embas... AIM:To investigate the effect of pharmacological pupil alterations on intraocular lens(IOL)power calculations.METHODS:A systematic review and Meta-analysis of studies published before December 2023 in the PubMed,Embase,and Cochrane library databases on the accuracy of pharmacological pupil changes on IOL power calculation was performed.The primary outcome was the results of IOL power calculations before and after the use of medications.Subgroup analyses were performed based on participants’basic characteristics,such as age,axial length(AL),and whether miosis or mydriasis were used as classification criteria for further analyses.Each eligible study was evaluated for potential risk of bias by the AHRQ assessment scale.The study was registered on PROSPERO(CRD 42024497535).RESULTS:A total of 3062 eyes from 21 studies were eligible.There was no significant difference in the IOL power calculation before and after pharmacological pupil changes using any of the Hoffer Q(WMD=0.055,95%CI=-0.046–0.156;P=0.29),SRK/T(WMD=0.003,95%CI=-0.073–0.080;P=0.93),Haigis(WMD=-0.030,95%CI=-0.176–0.116;P=0.69),Holladay 2(WMD=-0.042,95%CI=-0.366–0.282;P=0.80),and Barrett Universal Ⅱ(WMD=0.033,95%CI=-0.061–0.127;P=0.49)formulas.On the measurement of parameters related to IOL power calculation,for either miosis or mydriasis AL(P=0.98 and 0.29,respectively),lens thickness(P=0.96 and 0.13,respectively),and mean keratometry(P=0.90 and 0.86,respectively)did not present significant differences,while anterior chamber depth(P=0.07 and<0.01,respectively)and white-to-white distance(P=0.01 and 0.04,respectively)changed significantly between the two measurements prior and posterior.At the same time,despite there being some participants with the difference between the before and after calculations greater than 0.5 diopter,there was no significant difference in the incidence rate between these formulas.CONCLUSION:There is no significant effect of pharmacological pupil changes on the IOL power calculation.It will considerably reduce the visit time burden for patients who require cataract surgery. 展开更多
关键词 ocular biometry intraocular lens power calculation CATARACT pharmacological pupil alterations
原文传递
Comparison of asymmetric offset versus pupil centered ablation in refractive surgery
5
作者 Hassan Hashemi Mojgan Pakbin +2 位作者 Alireza Hashemi Mohammadreza Aghamirsalim Mehdi Khabazkhoob 《International Journal of Ophthalmology(English edition)》 2025年第8期1537-1543,共7页
AIM:To compare the visual and optical outcomes following femtosecond laser in situ keratomileusis(FS-LASIK)using an aberration neutral profile with asymmetric offset(AO)and pupil center(PC)treatments.METHODS:In this r... AIM:To compare the visual and optical outcomes following femtosecond laser in situ keratomileusis(FS-LASIK)using an aberration neutral profile with asymmetric offset(AO)and pupil center(PC)treatments.METHODS:In this randomized double-blind clinical trial study,48(24 cases)and 38 eyes(19 cases)underwent myopic astigmatism and hyperopic astigmatism LASIK.One eye of each individual was randomly assigned to AO centration and the fellow eye underwent the PC-centered method.The clinical outcomes including uncorrected visual acuity(UCVA),best-corrected visual acuity(BCVA),safety and efficacy indexes,subjective spherical equivalent(SE)and corneal high-order aberrations(HOAs)were measured at baseline and 6mo postoperatively.RESULTS:In the myopic group,the mean preoperative SE and astigmatism were-4.12±0.87(-2.88 to-6.00)diopter(D)and-0.88±0.79(0 to-2.75)D,respectively.In the hyperopic group,the mean preoperative SE and astigmatism were 0.93±0.59(-0.25 to 2.25)D and-0.73±1.00(0 to-4.25)D,respectively.At 6mo postoperatively,the safety and efficacy indexes were similar for centration in myopic and hyperopic LASIK groups.In the myopic group,significant changes were found in horizontal trefoil(P=0.041)and oblique trefoil(P=0.031)in favor of AO centration treatment.CONCLUSION:Femtosecond-LASIK is a safe and efficacious procedure for treatment of myopic and hyperopic astigmatism.AO-centered and PC-centered approaches provide similar visual and refractive outcomes.Myopic astigmatism LASIK with AO centration leads to slightly better corneal aberration outcomes. 展开更多
关键词 femtosecond laser in situ keratomileusis asymmetric offset pupil center
原文传递
Robust and High Accuracy Algorithm for Detection of Pupil Images 被引量:1
6
作者 Waleed El Nahal Hatim G.Zaini +2 位作者 Raghad H.Zaini Sherif S.M.Ghoneim Ashraf Mohamed Ali Hassan 《Computers, Materials & Continua》 SCIE EI 2022年第10期33-50,共18页
Recently,many researchers have tried to develop a robust,fast,and accurate algorithm.This algorithm is for eye-tracking and detecting pupil position in many applications such as head-mounted eye tracking,gaze-based hu... Recently,many researchers have tried to develop a robust,fast,and accurate algorithm.This algorithm is for eye-tracking and detecting pupil position in many applications such as head-mounted eye tracking,gaze-based human-computer interaction,medical applications(such as deaf and diabetes patients),and attention analysis.Many real-world conditions challenge the eye appearance,such as illumination,reflections,and occasions.On the other hand,individual differences in eye physiology and other sources of noise,such as contact lenses or make-up.The present work introduces a robust pupil detection algorithm with and higher accuracy than the previous attempts for real-time analytics applications.The proposed circular hough transform with morphing canny edge detection for Pupillometery(CHMCEP)algorithm can detect even the blurred or noisy images by using different filtering methods in the pre-processing or start phase to remove the blur and noise and finally the second filtering process before the circular Hough transform for the center fitting to make sure better accuracy.The performance of the proposed CHMCEP algorithm was tested against recent pupil detection methods.Simulations and results show that the proposed CHMCEP algorithm achieved detection rates of 87.11,78.54,58,and 78 according to´Swirski,ExCuSe,Else,and labeled pupils in the wild(LPW)data sets,respectively.These results show that the proposed approach performs better than the other pupil detection methods by a large margin by providing exact and robust pupil positions on challenging ordinary eye pictures. 展开更多
关键词 pupil detection eye tracking pupil edge morphing techniques eye images dataset
在线阅读 下载PDF
A Pupil-Positioning Method Based on the Starburst Model 被引量:1
7
作者 Pingping Yu Wenjie Duan +3 位作者 Yi Sun Ning Cao Zhenzhou Wang Guojun Lu 《Computers, Materials & Continua》 SCIE EI 2020年第8期1199-1217,共19页
Human eye detection has become an area of interest in the field of computer vision with an extensive range of applications in human-computer interaction,disease diagnosis,and psychological and physiological studies.Ga... Human eye detection has become an area of interest in the field of computer vision with an extensive range of applications in human-computer interaction,disease diagnosis,and psychological and physiological studies.Gaze-tracking systems are an important research topic in the human-computer interaction field.As one of the core modules of the head-mounted gaze-tracking system,pupil positioning affects the accuracy and stability of the system.By tracking eye movements to better locate the center of the pupil,this paper proposes a method for pupil positioning based on the starburst model.The method uses vertical and horizontal coordinate integral projections in the rectangular region of the human eye for accurate positioning and applies a linear interpolation method that is based on a circular model to the reflections in the human eye.In this paper,we propose a method for detecting the feature points of the pupil edge based on the starburst model,which clusters feature points and uses the RANdom SAmple Consensus(RANSAC)algorithm to perform ellipse fitting of the pupil edge to accurately locate the pupil center.Our experimental results show that the algorithm has higher precision,higher efficiency and more robustness than other algorithms and excellent accuracy even when the image of the pupil is incomplete. 展开更多
关键词 Human eye localization ellipse fitting pupil contour pupil center
在线阅读 下载PDF
Robust Facial Biometric Authentication System Using Pupillary Light Reflex for Liveness Detection of Facial Images
8
作者 Puja S.Prasad Adepu Sree Lakshmi +5 位作者 Sandeep Kautish Simar Preet Singh Rajesh Kumar Shrivastava Abdulaziz S.Almazyad Hossam M.Zawbaa Ali Wagdy Mohamed 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第4期725-739,共15页
Pupil dynamics are the important characteristics of face spoofing detection.The face recognition system is one of the most used biometrics for authenticating individual identity.The main threats to the facial recognit... Pupil dynamics are the important characteristics of face spoofing detection.The face recognition system is one of the most used biometrics for authenticating individual identity.The main threats to the facial recognition system are different types of presentation attacks like print attacks,3D mask attacks,replay attacks,etc.The proposed model uses pupil characteristics for liveness detection during the authentication process.The pupillary light reflex is an involuntary reaction controlling the pupil’s diameter at different light intensities.The proposed framework consists of two-phase methodologies.In the first phase,the pupil’s diameter is calculated by applying stimulus(light)in one eye of the subject and calculating the constriction of the pupil size on both eyes in different video frames.The above measurement is converted into feature space using Kohn and Clynes model-defined parameters.The Support Vector Machine is used to classify legitimate subjects when the diameter change is normal(or when the eye is alive)or illegitimate subjects when there is no change or abnormal oscillations of pupil behavior due to the presence of printed photograph,video,or 3D mask of the subject in front of the camera.In the second phase,we perform the facial recognition process.Scale-invariant feature transform(SIFT)is used to find the features from the facial images,with each feature having a size of a 128-dimensional vector.These features are scale,rotation,and orientation invariant and are used for recognizing facial images.The brute force matching algorithm is used for matching features of two different images.The threshold value we considered is 0.08 for good matches.To analyze the performance of the framework,we tested our model in two Face antispoofing datasets named Replay attack datasets and CASIA-SURF datasets,which were used because they contain the videos of the subjects in each sample having three modalities(RGB,IR,Depth).The CASIA-SURF datasets showed an 89.9%Equal Error Rate,while the Replay Attack datasets showed a 92.1%Equal Error Rate. 展开更多
关键词 SIFT pupil CASIA-SURF pupillary light reflex replay attack dataset brute force
在线阅读 下载PDF
How to Establish Good Teacher-Pupil Rapport in the Classroom?
9
作者 李晶 《海外英语》 2015年第18期207-208,211,共3页
for the past few decades,the way to achieve good teacher-pupil rapport in the classroom has been at the center of heated debate all over the world.All teachers should provide a good studying environment for pupils.Thi... for the past few decades,the way to achieve good teacher-pupil rapport in the classroom has been at the center of heated debate all over the world.All teachers should provide a good studying environment for pupils.This paper will focus on four parts to discuss this issue. 展开更多
关键词 GOOD teacher-pupil RAPPORT
在线阅读 下载PDF
Pupils in Wenchuan Earthquake
10
作者 胡永德 《中学生英语(高中版)》 2008年第Z6期74-,共1页
A great earthquake broke out in WenChuan. A lot of people were killed, but somany people were rescused by soldiers.Here are stories about three recused pupils.Langzhen, aged three, was rescusedby the soldiers after be... A great earthquake broke out in WenChuan. A lot of people were killed, but somany people were rescused by soldiers.Here are stories about three recused pupils.Langzhen, aged three, was rescusedby the soldiers after being buried in ruinsfor 10 hours. 展开更多
关键词 pupils in Wenchuan Earthquake
在线阅读 下载PDF
Photopic pupil size change in myopic orthokeratology and its influence on axial length elongation 被引量:9
11
作者 Meng-Jun Zhu Li Ding +4 位作者 Lin-Lin Du Jun Chen Xian-Gui He Shan-Shan Li Hai-Dong Zou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第8期1322-1330,共9页
AIM:To explore the photopic pupil size behavior in myopic children undergoing overnight orthokeratology(ortho-k)over 1-year period and its effects on the axial elongation.METHODS:A total of 202 Chinese myopic children... AIM:To explore the photopic pupil size behavior in myopic children undergoing overnight orthokeratology(ortho-k)over 1-year period and its effects on the axial elongation.METHODS:A total of 202 Chinese myopic children were enrolled in this prospective clinical trial.Ninetyfive subjects in ortho-k group and eighty-eight subjects in spectacle group completed the 1-year study.Axial length(AL)was measured before enrollment and every 6mo after the start of ortho-k.The photopic pupil diameter(PPD)was determined using the Pentacam AXL and measured in an examination room with lighting of 300-310 Lx.Stepwise multiple linear regression analysis was used to identify variables contribution to axial elongation.RESULTS:Compared with spectacle group,the average 1-year axial elongation was significantly slower in the ortho-k group(0.25±0.27 vs 0.44±0.23 mm,P<0.0001).In ortho-k group,PPDs significantly decreased from 4.21±0.62 mm to 3.94±0.53 mm after 1mo of lens wear(P=0.001,Bonferroni correction)and the change lasts for 3-month visit.No significantly change during the other follow-up visits was found(P>0.05,Bonferroni correction).The 4.81 mm PPD may be a possible cutoff point in the ortho-k group.Subjects with PPD below or equal to 4.81 mm tended to have smaller axial elongation compared to subjects with PPD above 4.81 mm after 1-year period(t=-3.09,P=0.003).In ortho-k group,univariate analyses indicated that those with older age,greater degree of myopia,longer AL,smaller baseline PPD(PPDbaseline)experienced a smaller change in AL.In multivariate analyses,older age,greater AL and smaller PPDbaseline were associated with smaller increases in AL.In spectacle group,PPD tended to be stable(P>0.05,Bonferroni correction)and did not affect axial growth.CONCLUSION:PPDs experience significantly decreases at 1-month and 3-month ortho-k treatment.Children with smaller PPD tend to experience slower axial elongation and may benefit more from ortho-k. 展开更多
关键词 ORTHOKERATOLOGY MYOPIA axial length pupil diameter ACCOMMODATION
原文传递
Ocular higher-order aberrations and mesopic pupil size in individuals screened for refractive surgery 被引量:3
12
作者 Seyed Javad Hashemian Mohammad Soleimani +4 位作者 Alireza Foroutan Mahmood Joshaghani Mohammad Jafar Ghaempanah Mohammad Ebrahim Jafari Mehdi Yaseri 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第2期222-225,共4页
AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 e... AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 eyes of 1 240 patients with myopia, myopic astigmatism and compound myopic astigmatism and 215 eyes of 110 patients with hyperopia, hyperopic astigmatism and compound hyperopic astigmatism using the Zywave aberrometer (Busch& Lomb). All patients had correctable refractive errors without a history of refractive surgery or underlying diseases. Root-mean-square values of HOAs, total spherical aberration, total coma and mesopic pupil size were analyzed. Ocular HOAs were measured across a ≥ 6.0 mm pupil, and pupil size measurements were performed under the mesopic condition. · RESULTS: The mean values of HOAs, total spherical aberration and total coma in the myopic group were 0.369 μm, ±0.233, 0.133±0.112μm and 0.330±0.188μm, respectively. In the hyperopic group the mean values of HOAs, total spherical aberration and total coma were 0.418μm±0.214, 0.202±0.209μm and 0.343±0.201μm, respectively. Hyperopes showed greater total HOAs (P <0.01) and total spherical aberration (P <0.01) compared to myopes. In age-matched analysis, only the amount of total spherical aberration was higher in the hyperopic group (P =0.05). Mesopic pupil size in the myopic group was larger (P ≤0.05). · CONCLUSION: The results suggested that significant levels of HOAs were found in both groups which are important for planning refractive surgeries on Iranians. There were significantly higher levels of total spherical aberration in hyperopes compared to myopes. Mesopic pupil size was larger in myopic group. 展开更多
关键词 corneal wavefront aberration pupil mesopic vision RACE MYOPIA HYPEROPIA
原文传递
A self-made disposable iris retractor in small pupil phacoemulsification 被引量:4
13
作者 Jie Li Fei Liu +1 位作者 Wei-Wei Zhang Jun-Jun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期288-292,共5页
AIM:To explore a simple and low-cost self-made disposable flexible iris retractor and study its clinical efficacy and safety in small pupil phacoemulsification.METHODS:Polyproplyenesutureandscalpacupuncture were used ... AIM:To explore a simple and low-cost self-made disposable flexible iris retractor and study its clinical efficacy and safety in small pupil phacoemulsification.METHODS:Polyproplyenesutureandscalpacupuncture were used to make iris retractor.A prospective study were carried on 50 patients(50 eyes)with a maximally dilated pupil size of 2.5-4.0 mm which underwent phacoemulsification using this self-made iris retractor.Another 50 cases of phacoemulsification with normal pupil size sever as control group.The mean operation time,ultrasound time and ultrasonic power,volume of irrigation fluid were documented intraoperatively.The visual acuity,pupil size and complication were observed on 1d,1wk,1mo and 1y after operation.Corneal endothelial cell was measured at 1mo postoperatively.·RESULT:Pupils could be expanded to approximately4.5-5.5 mm with our self-made iris retractor in operation.No serious postoperative complication was found.Most(88%)of the pupils returned round or oval shape,light reflex restored to varying degrees at the first day after surgery.Best corrected visual acuity stabilized in 37 eyes(74%)at one day,in 43 eyes(86%)at one week,in 44eyes(88%)at one month and 46 eyes(92%)at one year.Compared with the control,more time was needed to complete the operation in the small pupil group.There was no significant difference of the mean ultrasound time,ultrasonic power,volume of irrigation fluid requiredand corneal endothelial cell loss in 1mo follow up between the two groups.CONCLUSION:Our self-made disposable flexible iris retractor could be easy obtained preoperatively or intraoperatively.It performed both safety and efficacy in our clinical trials.This simple self-made device has shown economic and practical values,especially in primary care hospital of the less developed districts. 展开更多
关键词 small pupil iris retractor PHACOEMULSIFICATION
原文传递
Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses 被引量:2
14
作者 Eleni Papadatou Antonio J.Del Aguila-Carrasco +2 位作者 Jose J.Esteve-Taboada David Madrid-Costa Alejandro Cervino-Exposito 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期103-108,共6页
AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one mul... AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed.RESULTS: The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about ?3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens.CONCLUSION: In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient’s visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome. 展开更多
关键词 multifocal contact lenses pupil size power profiles refractive power distribution
原文传递
Simple PSF based method for pupil phase mask’s optimization in wavefront coding system 被引量:2
15
作者 ZHANG Wen-zi CHEN Yan-ping +2 位作者 ZHAO Ting-yu YE Zi YU Fei-hong 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第2期180-185,共6页
By applying the wavefront coding technique to an optical system, the depth of focus can be greatly increased. Several complicated methods, such as Fisher Information based method, have already been taken to optimize f... By applying the wavefront coding technique to an optical system, the depth of focus can be greatly increased. Several complicated methods, such as Fisher Information based method, have already been taken to optimize for the best pupil phase mask in ideal condition. Here one simple point spread function (PSF) based method with only the standard deviation method used to evaluate the PSF stability over the depth of focus is taken to optimize for the best coefficients of pupil phase mask in practical optical systems. Results of imaging simulations for optical systems with and without pupil phase mask are presented, and the sharpness of image is calculated for comparison. The optimized results showed better and much more stable imaging quality over the original system without changing the position of the image plane. 展开更多
关键词 Wavefront coding pupil phase mask Depth of focus PSF stability OPTIMIZATION SHARPNESS Imaging simulation
在线阅读 下载PDF
THE INVESTIGATION AND ANALYSIS OF THE PSYCHOLOGICAL DISORDERS OF THE PUPILS(9~12YEARS OF AGE)OF XI'AN CITY 被引量:2
16
作者 侯如兰 周爱兰 +1 位作者 余红霞 雷静 《Journal of Pharmaceutical Analysis》 CAS 1996年第1期44-47,共4页
pupils aged 9~12 years from six primary schools were cross-sectionally investigated on the psychological disorders with Conner Scale and EPQ. The results showed that the incidence of psychological disorders was 18. 2... pupils aged 9~12 years from six primary schools were cross-sectionally investigated on the psychological disorders with Conner Scale and EPQ. The results showed that the incidence of psychological disorders was 18. 2%,with 21. 3% in male and 15. 5% in female. The incidehees were significantly difrerent between male and remal (P<0. 05). The incidences or learning difficulty,hyperactivity and impulsive behavior were 8. 2%, 5. 3%,and 5.3% respectively.The family factors influencing the psychological disorders were the pupils'birth problems,the relationship between the pupils and their parents, and the parents'inappropriate prospect for the pupils.The investigation also found that the pupils with psychological disorders had more poor experiences or their family and school and more of them had obvious personality tendencies towards unstability or emotion,eccentricity and social immaturity as compared with the normal pupils. The effective measures to promote pupils'psychological health were suggested in this article. 展开更多
关键词 psychological disorder pupil Conner Scale Eysenck Personality Questionnaire (EPQ)
暂未订购
Corneal white-to-white distance and mesopic pupil diameter 被引量:1
17
作者 Hasan Basri Cakmak Nurullah Cagil +1 位作者 Huseyin Simavli Sabri Raza 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第4期505-509,共5页
·AIM:To study the relationship between corneal white-to- white (WTW) distance and mesopic pupil diameter. ·METHODS:This study is composed of 30 cases that underwent photorefractive keratotomy (PRK). Pupil si... ·AIM:To study the relationship between corneal white-to- white (WTW) distance and mesopic pupil diameter. ·METHODS:This study is composed of 30 cases that underwent photorefractive keratotomy (PRK). Pupil size measurements were performed with Schwind ORK wavefront analyzer in mesopic conditions. WTW distance was measured with a measuring caliper. Also, A-scan ultrasound examination was performed in all patients. The relationship among the mesopic pupil diameter and age, sex, axial length, lens thickness, anterior chamber depth(ACD), horizontal WTW distance, vertical WTW distance, spherical equivalent, and average keratometry were analyzed with univariate and multivariate regression analysis. ·RESULTS:Mean pupil diameter was (6.39±0.80)mm (range:3.70mm to 7.73mm. Horizontal WTW distance measurements were between 11.00mm and 12.50mm and mean horizontal WTW distance was (11.79±0.43)mm. On the other hand, vertical WTW distances ranged between 10.00mm and 13.00mm, and their mean was(11.42±0.72)mm. Bivariate correlation between pupil diameter and other variables showed that the axial length, ACD, spherical equivalent, and horizontal WTW distance had a moderate correlation with mesopic pupil diameter. Multiple regression analysis revealed that spherical equivalent and horizontal WTW distances were significantly associated with mesopic pupil diameter (R =0.598, R 2=0.358 P =0.02). ·CONCLUSION:This study shows that mesopic pupil diameter is closely related to horizontal WTW distance. These two factors must be taken in consideration together in preoperative ablation zone planning. 展开更多
关键词 mesopic pupil diameter photorefractive keratectomy white-to-white distance
原文传递
The Human Eye Pupil Detection System Using BAT Optimized Deep Learning Architecture 被引量:1
18
作者 S.Navaneethan P.Siva Satya Sreedhar +1 位作者 S.Padmakala C.Senthilkumar 《Computer Systems Science & Engineering》 SCIE EI 2023年第7期125-135,共11页
The pupil recognition method is helpful in many real-time systems,including ophthalmology testing devices,wheelchair assistance,and so on.The pupil detection system is a very difficult process in a wide range of datas... The pupil recognition method is helpful in many real-time systems,including ophthalmology testing devices,wheelchair assistance,and so on.The pupil detection system is a very difficult process in a wide range of datasets due to problems caused by varying pupil size,occlusion of eyelids,and eyelashes.Deep Convolutional Neural Networks(DCNN)are being used in pupil recognition systems and have shown promising results in terms of accuracy.To improve accuracy and cope with larger datasets,this research work proposes BOC(BAT Optimized CNN)-IrisNet,which consists of optimizing input weights and hidden layers of DCNN using the evolutionary BAT algorithm to efficiently find the human eye pupil region.The proposed method is based on very deep architecture and many tricks from recently developed popular CNNs.Experiment results show that the BOC-IrisNet proposal can efficiently model iris microstructures and provides a stable discriminating iris representation that is lightweight,easy to implement,and of cutting-edge accuracy.Finally,the region-based black box method for determining pupil center coordinates was introduced.The proposed architecture was tested using various IRIS databases,including the CASIA(Chinese academy of the scientific research institute of automation)Iris V4 dataset,which has 99.5%sensitivity and 99.75%accuracy,and the IIT(Indian Institute of Technology)Delhi dataset,which has 99.35%specificity and MMU(Multimedia University)99.45%accuracy,which is higher than the existing architectures. 展开更多
关键词 BAT algorithm IRIS datasets DCNN pupil detection black box method
在线阅读 下载PDF
Pupil Size Measurement and Sucrose Ingestion for Quantifying and Decreasing Burden of Women during Mammography 被引量:1
19
作者 Yongbum Lee Mieko Uchiyama Tomoko Sumiyoshi 《Journal of Biomedical Science and Engineering》 2015年第10期700-706,共7页
Many women feel a physical burden, which usually appears as a pain, during mammography. We examined the pain-related pupil dilation response during mammography. Twenty-four healthy women participated in the examinatio... Many women feel a physical burden, which usually appears as a pain, during mammography. We examined the pain-related pupil dilation response during mammography. Twenty-four healthy women participated in the examination. They were randomly assigned to water group or sucrose group. Water group and sucrose group ingested distilled water and a sucrose solution during mammography, respectively. Their pupil sizes were measured during mammography excluding X-ray irradiation. The subjective intensity of pain during mammography was also assessed using visual analogue scales (VAS). The mean pupil diameter was 2.99 mm in relaxation phase before mammography, while it was 3.15 mm in a few seconds after breast compression (pressure phase). The difference between the two was statistically significant (p p < 0.01). These results suggest that we may be able to assess objectively the degree of pain associated with mammography and sweet taste stimuli may be effective to alleviate a women’s burden received during mammography. 展开更多
关键词 MAMMOGRAPHY PAIN Assessment PAIN Alleviation pupil DILATION Sweet Stimuli
暂未订购
上一页 1 2 152 下一页 到第
使用帮助 返回顶部