期刊文献+
共找到3,888篇文章
< 1 2 195 >
每页显示 20 50 100
Electronic Unit Pump Test Bench Development and Pump Properties Research 被引量:1
1
作者 刘波澜 黄英 +1 位作者 张付军 赵长禄 《Journal of Beijing Institute of Technology》 EI CAS 2006年第4期384-388,共5页
A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection co... A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test both mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is done. Experimental results show that the injection quantity is linear with the delivery angle. The quantity change rate is 15% when fuel temperature increases 30 ℃. The delivery quantity per cycle increases 30 mg at 28 V drive voltage. The average delivery difference for two same type pumps is 5 %. Test results show that the bench can be used for unit pump verification. 展开更多
关键词 unit pump test bench control system experimental research
在线阅读 下载PDF
Comparison between Neuman(1975) and Jacob(1946) application for analysing pumping test data of unconfined aquifer 被引量:3
2
作者 Dana Mawlood Jwan Mustafa 《Journal of Groundwater Science and Engineering》 2016年第3期165-173,共9页
Pumping test of a water table aquifer is carried out to estimate the aquifer parameters, the obtained data were analysed through the solution of both Neuman(1975) and Jacob(1946) methods through AQTESOLV and Spreadshe... Pumping test of a water table aquifer is carried out to estimate the aquifer parameters, the obtained data were analysed through the solution of both Neuman(1975) and Jacob(1946) methods through AQTESOLV and Spreadsheet programs, the results of each methods are compared to evaluate the applicability and accuracy of the solution theoretically and practically. In the paper an example is presented, which is conducted for a constant rate pumping test from Ohio, in Fairborn(near Dayton), and it supplied by S.E. Norris(U.S. Geological Survey, Columbus, Ohio). The main objective of this study is to introduce both program and the way of the applications, and compare the results and the hand on of both programs in the field. 展开更多
关键词 Neuman(1975) Unconfined aquifer pumping test AQTESOLV program Microsoft Excel(Spreadsheet) program
在线阅读 下载PDF
Inverse modelling of aquifer parameters in basaltic rock with the help of pumping test method using MODFLOW software 被引量:1
3
作者 Kanak Moharir Chaitanya Pande Sanjay Patil 《Geoscience Frontiers》 SCIE CAS CSCD 2017年第6期1385-1395,共11页
The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems.As groundwater flows ... The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems.As groundwater flows through an aquifer,its composition and temperature may variation dependent on the aquifer condition through which it flows.Thus,hydrologic investigations can also provide useful information about the subsurface geology of a region.But because such studies investigate processes that follow under the Earth's shallow,obtaining the information necessary to answer these questions is not continuously easy.Springs,which discharge groundwater table directly,afford to study subsurface hydrogeological processes.The present study of estimation of aquifer factors such as transmissivity(T)and storativity(S)are vital for the evaluation of groundwater resources.There are several methods to estimate the accurate aquifer parameters(i.e.hydrograph analysis,pumping test,etc.).In initial days,these parameters are projected either by means of in-situ test or execution test on aquifer well samples carried in the laboratory.The simultaneous information on the hydraulic behavior of the well(borehole)that provides on this method,the reservoir and the reservoir boundaries,are important for efficient aquifer and well data management and analysis.The most common in-situ test is pumping test performed on wells,which involves the measurement of the fall and increase of groundwater level with respect to time.The alteration in groundwater level(drawdown/recovery)is caused due to pumping of water from the well.Theis(1935)was first to propose method to evaluate aquifer parameters from the pumping test on a bore well in a confined aquifer.It is essential to know the transmissivity(T=Kb,where b is the aquifer thickness;pumping flow rate,Q=TW(dh/dl)flow through an aquifer)and storativity(confined aquifer:S=bS_s,unconfined:S=S_y),for the characterization of the aquifer parameters in an unknown area so as to predict the rate of drawdown of the groundwater table/potentiometric surface throughout the pumping test of an aquifer.The determination of aquifer's parameters is an important basis for groundwater resources evaluation,numerical simulation,development and protection as well as scientific management.For determining aquifer's parameters,pumping test is a main method.A case study shows that these techniques have been fast speed and high correctness.The results of parameter's determination are optimized so that it has important applied value for scientific research and geology engineering preparation. 展开更多
关键词 pumpING test Hantush method GPS MODFLOW INVERSE modelling Hydraulic parameters
在线阅读 下载PDF
Impact of Typical Steady-state Conditions and Transient Conditions on Flow Ripple and Its Test Accuracy for Axial Piston Pump 被引量:15
4
作者 XU Bing HU Min ZHANG Junhui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第5期1012-1022,共11页
The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated wo... The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated working conditions. However, the pump usually has to work in large-scale and time-variant working conditions. Therefore, the flow ripple characteristics of pump and analysis for its test accuracy with respect to variant steady-state conditions and transient conditions in a wide range of operating parameters are focused in this paper. First, a simulation model has been constructed, which takes the kinematics of oil film within friction pairs into account for higher accuracy. Afterwards, a test bed which adopts Secondary Source Method is built to verify the model. The simulation and tests results show that the angular position of the piston, corresponding to the position where the peak flow ripple is produced, varies with the different pressure. The pulsating amplitude and pulsation rate of flow ripple increase with the rise of pressure and the variation rate of pressure. For the pump working at a constant speed, the flow pulsation rate decreases dramatically with the increasing speed when the speed is less than 27.78% of the maximum speed, subsequently presents a small decrease tendency with the speed further increasing. With the rise of the variation rate of speed, the pulsating amplitude and pulsation rate of flow ripple increase. As the swash plate angle augments, the pulsating amplitude of flow ripple increases, nevertheless the flow pulsation rate decreases. In contrast with the effect of the variation of pressure, the test accuracy of flow ripple is more sensitive to the variation of speed. It makes the test accuracy above 96.20% available for the pulsating amplitude of pressure deviating within a range of ~6% from the mean pressure. However, with a variation of speed deviating within a range of ±2% from the mean speed, the attainable test accuracy of flow ripple is above 93.07%. The model constructed in this research proposes a method to determine the flow ripple characteristics of pump and its attainable test accuracy under the large-scale and time-variant working conditions. Meanwhile, a discussion about the variation of flow ripple and its obtainable test accuracy with the conditions of the pump working in wide operating ranges is given as well. 展开更多
关键词 axial piston pump flow ripple test accuracy steady-state condition transient condition wide operating ranges
在线阅读 下载PDF
Influence of proton pump inhibitor treatment on Helicobacter pylori stool antigen test 被引量:7
5
作者 Masaaki Kodama Kazunari Murakami +6 位作者 Tadayoshi Okimoto Yoshihiro Fukuda Tadashi Shimoyama Masumi Okuda Chieko Kato Intetsu Kobayashi Toshio Fujioka 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第1期44-48,共5页
AIM: To investigate the effects of proton pump inhibitor (PPI) treatment on stool antigen test using the TestMate pylori enzyme immunoassay. METHODS: This study assessed 28 patients [16 men and 12 women; mean age (63.... AIM: To investigate the effects of proton pump inhibitor (PPI) treatment on stool antigen test using the TestMate pylori enzyme immunoassay. METHODS: This study assessed 28 patients [16 men and 12 women; mean age (63.1 ± 5.9) years; range, 25-84 years] who underwent stool antigen test and urea breath test (UBT) before and after PPI administration. RESULTS: Using the UBT as the standard, the sensitivity, specif icity and agreement of the stool antigen test in all 28 patients were 95.2%, 71.4%, and 89.3%, respectively, before PPI administration, and 88.9%, 90.9%, and 89.3%, respectively, after PPI treatment. Mean UBT values were 23.98% ± 5.33% before and 16.19% ± 4.75% after PPI treatment and, in 15 patients treated for ≥ 4 wk, were signif icantly lower after than before 4 wk of PPI treatment (12.58% ± 4.49% vs 24.53% ± 8.53%, P = 0.048). The mean optical density (A450/630) ratios on the stool antigen test were 1.16 ± 0.20 before and 1.17 ± 0.24 after PPI treatment (P = 0.989), and were 1.02 ± 0.26 and 0.69 ± 0.28, respectively, in the group treated for > 4 wk (P = 0.099). 展开更多
关键词 HELICOBACTER PYLORI STOOL ANTIGEN test Urea BREATH test Proton pump inhibitor
暂未订购
Determination of Aquifer Parameters by Numerical Model Based on the Large Scale-Pumping Test:A Case Study in Yanqi Basin
6
作者 Jin Gao,Xinguang Dong 1.College of Resources and Environment Science,Xinjiang University,rümqi,China. 2.Xinjiang Water Resources Bureau,rümqi,China 《地学前缘》 EI CAS CSCD 北大核心 2009年第S1期21-21,共1页
The determination of aquifer parameters is the basis for groundwater resource evaluation,development and protection as well as scientific management. Pumping test is a main method to determine the aquifer parameters.H... The determination of aquifer parameters is the basis for groundwater resource evaluation,development and protection as well as scientific management. Pumping test is a main method to determine the aquifer parameters.However,the analytic methods can’t be used to describe the heterogeneous and spatial variant of the parameters in detail.The aquifer parameters derived from analytic methods may lead much uncertainty of groundwater resource evaluation. 展开更多
关键词 pumpING test PARAMETERS NUMERICAL MODELING INVERSION MODELING
在线阅读 下载PDF
Novel method for operating characteristics test of a hydraulic pump
7
作者 王向周 陆叶 郑戍华 《Journal of Beijing Institute of Technology》 EI CAS 2015年第1期74-82,共9页
The traditional testing method of a hydraulic pump requires a large amount of test data from a variety of pump working conditions. The test is usually time-consuming and energy-consu- ming. And the accurate characteri... The traditional testing method of a hydraulic pump requires a large amount of test data from a variety of pump working conditions. The test is usually time-consuming and energy-consu- ming. And the accurate characteristic curves of the pump were hardly obtained due to a limited a- mount and discreteness of the test data. In order to simplify the test procedure and improve the test accuracy, a novel method for measuring hydraulic pump operating characteristic based on multi-ele- ment nonlinear regression (NLMR) modeling is proposed in this paper. The main idea of this model- ing method is establishing a mathematical model to predict the performance parameters of the hy- draulic pump, only a small amount of test data is needed. Consequently, the pump operating charac- teristics in any working conditions are obtained. And the test results of the pump are easily charac- terized in the graphs, charts, tables and so on. The evaluations of the model are carried out and dis- cussed in this paper. The result shows that the test error of the novel method can be controlled to be about 0. 1%. Compared with the traditional test method, the proposed method reduces greatly the test time and the random error of the test data, and improves the efficiency and accuracy of the pump test. 展开更多
关键词 hydraulic pump test MODEL work characteristics
在线阅读 下载PDF
Application of acoustic emission (AE) technique in crack monitor during fatigue test of pump rods 被引量:3
8
作者 XIA Yong-fa LI Hai-ling 《材料与冶金学报》 CAS 2007年第1期60-63,共4页
关键词 水泵杆 机械疲劳 声音散射法 裂缝 监测
在线阅读 下载PDF
Groundwater Potentials Estimation of a Basement Terrain Using Pumping Test Data for Parts of Sanga Local Government Area, Kaduna State, Northwestern Nigeria
9
作者 Hamidu Hassan Sidi Muhammad Waru +1 位作者 Garga Ali Bukar Kana Muhammad Abdullahi 《Open Journal of Modern Hydrology》 2016年第4期222-229,共8页
Aquifers derived from the crystalline basement rocks for parts of Sanga Local Government area of Kaduna State, Nigeria consist of clay, silt, sand, gravel and laterite materials which may be in various proportions. Us... Aquifers derived from the crystalline basement rocks for parts of Sanga Local Government area of Kaduna State, Nigeria consist of clay, silt, sand, gravel and laterite materials which may be in various proportions. Using Cooper-Jacobs non-equilibrium graphical method, the hydraulic properties were estimated from pumping test data of 18 boreholes. Conductivity varies from 1.02 × 10<sup>﹣2</sup> m/s to 4.07 × 10<sup>﹣2</sup> m/s and transmissivity varies from 1.14 × 10<sup>﹣1</sup> m<sup>2</sup>/s to 4.40 × 10<sup>﹣1</sup> m<sup>2</sup>/s. The values of specific capacity range between 1.03 × 10<sup>﹣1</sup> m<sup>2</sup>/s/m and 9.00 × 10<sup>﹣2</sup> m<sup>2</sup>/s/m, and these values indicate that the aquifers in the area have low to moderate ground water potentials. The low yield range of between 0.45 l/s and 1.00 l/s recorded in the area shows the heterogeneous and anisotropy nature of the basement aquifer system in terms of groundwater discharge. On the average, the boreholes assessed have potentials to sustain local to regional supply provided the best drilling method and materials are used and well completion properly done. 展开更多
关键词 pumping test Heterogeneous ANISOTROPY Conductivity Discharge Sanga
在线阅读 下载PDF
Design of occlusion pressure testing system for infusion pump
10
作者 Peng Zhang Shu-Yi Wang +1 位作者 Chuan-Yi Yu Min-Yan Zhang 《Journal of Biomedical Science and Engineering》 2009年第6期431-434,共4页
Reliability of medical devices such as infusion pumps is extremely important because these devices are being used in patients who are in critical condition. Occlusion pressure, as an important parameter of infusion pu... Reliability of medical devices such as infusion pumps is extremely important because these devices are being used in patients who are in critical condition. Occlusion pressure, as an important parameter of infusion pumps, should be detected when an occlusion occurred. How-ever, infusion pumps’ occlusion pressure could not be tested and the performance of these pumps is not known to us. In order to test the occlusion pressure of infusion pump, a testing system has been put forward according to standards of IEC 60601-2-24:1998/ GB 9706.27- 2005. The system is comprised of sensor, acquisition card, three-way tap and so on;this system is controlled by a PC. At the same time, sampling rate could be changed if necessary and test time could be recorded. And then the characteristics of this system were studied, such as linear, effects of pump rates and different pumps. The system remained linear in a given environment. The higher is the pump rate, the faster is the time to reach occlusion condi-tion. The testing system has been proved to be effective in testing the occlusion pressure of infusion pumps and the accuracy error of pressure is content the demand of ±1% of range. 展开更多
关键词 INFUSION pump OCCLUSION PRESSURE testING System
暂未订购
DEVELOPMENT OF PT PUMP AND INJECTOR TEST STANDS FOR CUMMINS ENGINE
11
作者 Wang Defeng (1) Liu Ye (2) 《Journal of Northeast Forestry University》 SCIE CAS CSCD 1990年第1期86-92,共7页
The type PT-821 PT Pump test stand and type PT-881 injector test stand are a set of special test stands for calibration of PT Pumps and injectors of Cummins engines. Both test stands may be used in conjunction with an... The type PT-821 PT Pump test stand and type PT-881 injector test stand are a set of special test stands for calibration of PT Pumps and injectors of Cummins engines. Both test stands may be used in conjunction with any model of Bosch injection pump test benches for PT Pumps and injector calibration. During PT Pump calibration, the type PT-821 test stand should be used in conjunction with a Bosch injection pump lest bench. The PT Pump to be tested is installed on the Bosch injection pump test bench through a mounting bracket and is driven by the bench shaft. When calibrating PT injectors, both the PT-881 injector test stand and the PT-821 PT Pump test stand should be used in conjunction with a Bosch injection pump test bench, with the PT-881 injector test stand installed on Bosch test bench. The injector to be tested is driven by the Bosch injection pump test bench through a coupling. This paper describes the structure and function of the PT-821 PT Pump test stand and PT-881 injector test stand. Some technical problems arc described in detail. 展开更多
关键词 test stand PT pump and injectors Cummins diesel engine
在线阅读 下载PDF
3D Particle Image Velocimetry Test of Inner Flow in a Double Blade Pump Impeller 被引量:5
12
作者 LIU Houlin WANG Kai +3 位作者 YUAN Shouqi TAN Minggao WANG Yong RU Weimin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第3期491-497,共7页
The double blade pump is widely used in sewage treatment industry,however,the research on the internal flow characteristics of the double blade pump with particle image velocimetry(PIV) technology is very little at ... The double blade pump is widely used in sewage treatment industry,however,the research on the internal flow characteristics of the double blade pump with particle image velocimetry(PIV) technology is very little at present.To reveal inner flow characteristics in double blade pump impeller under off-design and design conditions,inner flows in a double blade pump impeller,whose specific speed is 111,are measured under the five off-design conditions and design condition by using 3D PIV test technology.In order to ensure the accuracy of the 3D PIV test,the external trigger synchronization system which makes use of fiber optic and equivalent calibration method are applied.The 3D PIV relative velocity synthesis procedure is compiled by using Visual C++ 2005.Then absolute velocity distribution and relative velocity distribution in the double blade pump impeller are obtained.Test results show that vortex exists in each condition,but the location,size and velocity of vortex core are different.Average absolute velocity value of impeller outlet increases at first,then decreases,and then increases again with increase of flow rate.Again average relative velocity values under 0.4,0.8,and 1.2 design condition are higher than that under 1.0 design condition,while under 0.6 and 1.4 design condition it is lower.Under low flow rate conditions,radial vectors of absolute velocities at impeller outlet and blade inlet near the pump shaft decrease with increase of flow rate,while that of relative velocities at the suction side near the pump shaft decreases.Radial vectors of absolute velocities and relative velocities change slightly under the two large flow rate conditions.The research results can be applied to instruct the hydraulic optimization design of double blade pumps. 展开更多
关键词 double blade pump IMPELLER inner flow 3D particle image velocimetry(PIV) test
在线阅读 下载PDF
AquiferTest软件在抽水试验中的应用
13
作者 张晋磊 王学谦 闫秀英 《技术与市场》 2025年第1期100-102,107,共4页
通过现场原位抽水试验确定的水文地质参数的精度和准确性会直接影响基坑降水工程的准确性和可靠性。结合在某场地进行的潜水非稳定流抽水试验,在数据处理过程中,传统人工配线法效率、精度低,运用AquiferTest软件计算了潜水含水层渗透系... 通过现场原位抽水试验确定的水文地质参数的精度和准确性会直接影响基坑降水工程的准确性和可靠性。结合在某场地进行的潜水非稳定流抽水试验,在数据处理过程中,传统人工配线法效率、精度低,运用AquiferTest软件计算了潜水含水层渗透系数,采用Neuman法、Boulton法、仿泰斯公式法计算,提高计算结果精度,并对计算结果进行分析优化得到最终结果,符合实际水文地质条件。 展开更多
关键词 抽水试验 渗透系数 Aquifertest软件 潜水含水层
在线阅读 下载PDF
AquiferTest软件求解承压含水层水文地质参数的方法及效果 被引量:18
14
作者 陶宗涛 闫志为 《水电能源科学》 北大核心 2012年第10期58-60,共3页
抽水试验是获取多项水文地质参数最常用的野外水文地质试验方法之一,其参数计算结果精度直接影响地下水资源评价精度。针对传统水文地质参数计算方法的缺陷,以马楼水源地勘探孔抽水试验为例,采用含水层试验软件AquiferTest计算水文地质... 抽水试验是获取多项水文地质参数最常用的野外水文地质试验方法之一,其参数计算结果精度直接影响地下水资源评价精度。针对传统水文地质参数计算方法的缺陷,以马楼水源地勘探孔抽水试验为例,采用含水层试验软件AquiferTest计算水文地质参数,并与传统计算方法做了比较。结果表明,该方法简捷、方便、实用、精度高。 展开更多
关键词 Aquifertest 水文地质参数 抽水试验 人工求参
原文传递
基于Aquifer Test的水文地质参数计算方法研究 被引量:15
15
作者 陶宗涛 闫志为 《水利科技与经济》 2012年第12期25-27,共3页
根据抽水试验结果,常用人工求参的方法确定水文地质参数。人工求参方法计算结果较为可靠,但计算过程繁琐,并且结果因人而异,具有人为随意性。利用AquiferTest软件求参,计算方便快捷,与人工求参方法对比,具有计算精度较高,规范性好等优点。
关键词 Aquifertest 水文地质参数 抽水试验
在线阅读 下载PDF
全程曲线拟合法和Aquifertest水文地质求参 被引量:8
16
作者 杜川 梁秀娟 +2 位作者 张茜 陈章 李文娟 《人民黄河》 CAS 北大核心 2014年第4期19-21,25,共4页
抽水试验是获取含水层水文地质参数的主要方法,求参结果直接影响对调查区水文地质条件的认识和地下水开发利用。传统求参方法存在主观影响大、求参时间长、易受外界影响和抽水阶段数据的不足等问题。通过全程曲线拟合法和Aquifertest软... 抽水试验是获取含水层水文地质参数的主要方法,求参结果直接影响对调查区水文地质条件的认识和地下水开发利用。传统求参方法存在主观影响大、求参时间长、易受外界影响和抽水阶段数据的不足等问题。通过全程曲线拟合法和Aquifertest软件分别从配线法和水位恢复法两个角度进行求参,并结合全程曲线拟合法确定最终取值。结果表明,采用Aquifertest软件求参便捷、准确,与水位恢复法求参结果的差异相对较小,全程曲线拟合法求参值具有唯一性和可靠性,多种方法结合求参能更真实反映水文地质情况。 展开更多
关键词 抽水试验 水文地质参数 Aquifertest软件 配线法 水位恢复法 全程曲线拟合法
在线阅读 下载PDF
基于AquiferTest与Matlab耦合的水文地质参数求解 被引量:6
17
作者 师永丽 张永波 张志祥 《水电能源科学》 北大核心 2015年第8期63-66,共4页
针对传统水文地质参数求解方法存在限制较多、工作繁琐、精度不高且不能直观反映出抽水的流场变化等缺点,以山西大佛寺煤矿抽水试验数据为基础,利用AquiferTest和Matlab建立模型,提出一种计算水文地质参数的新方法,最终所得水位预测值... 针对传统水文地质参数求解方法存在限制较多、工作繁琐、精度不高且不能直观反映出抽水的流场变化等缺点,以山西大佛寺煤矿抽水试验数据为基础,利用AquiferTest和Matlab建立模型,提出一种计算水文地质参数的新方法,最终所得水位预测值与实测值相近,结果可靠,可见该方法求解出的水文地质参数更加符合工程实际情况。 展开更多
关键词 Aquifertest MATLAB 抽水试验 水文地质参数
原文传递
RESEARCH ON DISTRIBUTION PAIR OFBENT-AXIS PUMP
18
作者 李方俊 王国彪 陆文 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1996年第1期54+48-53,共7页
The oil film thickness of the distribution pair of the bent-axis pump is tested dynamically in this paper. On the basis of synthetical consideration of the leakage flow rate, the loss of power and the ability to resis... The oil film thickness of the distribution pair of the bent-axis pump is tested dynamically in this paper. On the basis of synthetical consideration of the leakage flow rate, the loss of power and the ability to resist contaminant of the distribution pair,the parameters used to describe the distribution state are optimized. According to theoretical analyses and experimental research, the structure of the distribution plate is improved, and the ability to resist contaminant wear of the distribution pair is increased. Thus, it is possible to prolong the service life and working reliability of the pump. 展开更多
关键词 bent-axis pump distribution pair OPTIMUM dynamic test
在线阅读 下载PDF
基于AquiferTest的抽水试验参数计算方法分析 被引量:68
19
作者 蒋辉 《水文地质工程地质》 CAS CSCD 北大核心 2011年第2期35-38,共4页
抽水试验是水文地质勘查中最常用的水文地质试验,通过抽水试验,可准确计算水文地质参数。本文根据在河南豫东地区进行的抽水试验,分别用AquiferTest软件计算抽水试验参数和人工求参,进而进行对比分析得出:传统的人工求参,计算结果较为准... 抽水试验是水文地质勘查中最常用的水文地质试验,通过抽水试验,可准确计算水文地质参数。本文根据在河南豫东地区进行的抽水试验,分别用AquiferTest软件计算抽水试验参数和人工求参,进而进行对比分析得出:传统的人工求参,计算结果较为准确,可靠,但因人而异,有不唯一性;用AquiferTest软件计算抽水试验参数,规范、可比性好。本文最后还对参数取值问题进行了分析对比。 展开更多
关键词 抽水试验 人工求参 Aquifertest 水文地质参数
在线阅读 下载PDF
Pumping speed of cryopump for xenon 被引量:3
20
作者 LING Gui-long WEI Li-jun CAI Guo-biao 《航空动力学报》 EI CAS CSCD 北大核心 2015年第7期1731-1736,共6页
The xenon pumping speed testing system of the large-diameter external cryopump was designed to meet the plume test requirements for prototype electric propulsion.The flowmeter method was utilized to measure the xenon ... The xenon pumping speed testing system of the large-diameter external cryopump was designed to meet the plume test requirements for prototype electric propulsion.The flowmeter method was utilized to measure the xenon pumping speed.The test results show that the averaged effective pumping speed of doublecryopumps is 52 200L/s,and that of single-cryopump is 27 100L/s.The pumping speed ratio of two configurations is 1.93.It can be concluded that the pumping speed has in linear relationship with the number of cryopump,and the coefficient is irrelevant with the gas type.The averaged effective pumping speed of xenon is less than its nominal pumping speed,and the averaged pumping efficiency is 0.83.Under the identical inflow conditions,the averaged effective pumping speed ratio of nitrogen is 0.53,slightly less than the theoretical pumping speed ratio of 0.55.Consequently,it can be concluded that results assessment of large-diameter external cryopump design index can guide the engineering application,showing certain reference significance. 展开更多
关键词 VACUUM PLUME large-diameter external cryopump XENON pumping speed test
原文传递
上一页 1 2 195 下一页 到第
使用帮助 返回顶部