期刊文献+
共找到40篇文章
< 1 2 >
每页显示 20 50 100
Pulse rate estimation based on facial videos:an evaluation and optimization of the classical methods using both self-constructed and public datasets 被引量:1
1
作者 Chao-Yong Wu Jian-Xin Chen +3 位作者 Yu Chen Ai-Ping Chen Lu Zhou Xu Wang 《Traditional Medicine Research》 2024年第1期14-22,共9页
Pulse rate is one of the important characteristics of traditional Chinese medicine pulse diagnosis,and it is of great significance for determining the nature of cold and heat in diseases.The prediction of pulse rate b... Pulse rate is one of the important characteristics of traditional Chinese medicine pulse diagnosis,and it is of great significance for determining the nature of cold and heat in diseases.The prediction of pulse rate based on facial video is an exciting research field for getting palpation information by observation diagnosis.However,most studies focus on optimizing the algorithm based on a small sample of participants without systematically investigating multiple influencing factors.A total of 209 participants and 2,435 facial videos,based on our self-constructed Multi-Scene Sign Dataset and the public datasets,were used to perform a multi-level and multi-factor comprehensive comparison.The effects of different datasets,blood volume pulse signal extraction algorithms,region of interests,time windows,color spaces,pulse rate calculation methods,and video recording scenes were analyzed.Furthermore,we proposed a blood volume pulse signal quality optimization strategy based on the inverse Fourier transform and an improvement strategy for pulse rate estimation based on signal-to-noise ratio threshold sliding.We found that the effects of video estimation of pulse rate in the Multi-Scene Sign Dataset and Pulse Rate Detection Dataset were better than in other datasets.Compared with Fast independent component analysis and Single Channel algorithms,chrominance-based method and plane-orthogonal-to-skin algorithms have a more vital anti-interference ability and higher robustness.The performances of the five-organs fusion area and the full-face area were better than that of single sub-regions,and the fewer motion artifacts and better lighting can improve the precision of pulse rate estimation. 展开更多
关键词 pulse rate heart rate PHOTOPLETHYSMOGRAPHY observation and pulse diagnosis facial videos
暂未订购
A novel approach for extracting pulse rate,respiratory rate and heart rate from photoplethysmogram 被引量:3
2
作者 WANG Huimin YANG Lu LIANG Xingyu 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2021年第2期188-194,共7页
Photoplethysmogram(PPG)is a noninvasive method for detecting human cardiovascular pulse wave using optical technology.The PPG containing a lot of physiological information is from the MIMIC database.This paper propose... Photoplethysmogram(PPG)is a noninvasive method for detecting human cardiovascular pulse wave using optical technology.The PPG containing a lot of physiological information is from the MIMIC database.This paper proposes a combinatorial method of ensemble empirical mode decomposition(EEMD),cepstrum,fast Fourier transform(FFT)and zero-crossing detection to improve the robustness of the estimation of pulse rate(PR),heart rate(HR)and respiratory rate(RR)from the PPG.First,the PPG signal was decomposed into finite intrinsic mode functions(IMF)by EEMD.Because of its adaptive filtering property,the different signals were reconstructed using different IMFs when estimating different physiological parameters.Second,the PR was obtained by zero-crossing detection after rejecting low frequency IMFs containing artifacts.Third,IMFs with frequency between 1.00 Hz to 1.67 Hz(60 beats/min to 100 beats/min)were selected for estimating HR.Then,the frequency band that reflects the heart activity was analyzed by the cepstrum method.Finally,the respiratory signal can be extracted from PPG signal by IMFs with frequency between 0.05 Hz to 0.75 Hz(3 breahts/min to 45 breaths/min).Then the spectrum of signal was obtained by FFT analysis and the RR was estimated by detecting the maximum frequency peak.The algorithm has been tested on MIMIC database obtained from 53 adults.The experiment results show that the physiological parameters extracted by this integrated signal processing method are consistent with the real physiological parameters.And the computation load of this method is small and the precision is high(not larger than 1.17%in error). 展开更多
关键词 photoplethysmogram(PPG) pulse rate(PR) respiratory rate(RR) heart rate(HR) CEPSTRUM
在线阅读 下载PDF
Synchronous measurements of prefrontal activity and pulse rate variability during online video game playing with functional near-infrared spectroscopy 被引量:2
3
作者 Xuzhe Zhang Kehong Long +2 位作者 Ningxin Wang Jin Zhang Hao Lei 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第6期53-67,共15页
Interactions between the central nervous system(CNS)and autonomic nervous system(ANS)play a crucial role in modulating perception,cognition,and emotion production.Previous studies on CNS–ANS interactions,or heart–br... Interactions between the central nervous system(CNS)and autonomic nervous system(ANS)play a crucial role in modulating perception,cognition,and emotion production.Previous studies on CNS–ANS interactions,or heart–brain coupling,have often used heart rate variability(HRV)metrics derived from electrocardiography(ECG)recordings as empirical measurements of sympathetic and parasympathetic activities.Functional near-infrared spectroscopy(fNIRS)is a functional brain imaging modality that is increasingly used in brain and cognition studies.The fNIRS signals contain frequency bands representing both neural activity oscillations and heartbeat rhythms.Therefore,fNIRS data acquired in neuroimaging studies can potentially provide a single-modality approach to measure task-induced responses in the brain and ANS synchronously,allowing analysis of CNS–ANS interactions.In this proof-of-concept study,fNIRS was used to record hemodynamic changes from the foreheads of 20 university students as they each played a round of multiplayer online battle arena(MOBA)game.From the fNIRS recordings,neural and heartbeat frequency bands were extracted to assess prefrontal activities and shortterm pulse rate variability(PRV),an approximation for short-term HRV,respectively.Under the experimental conditions used,fNIRS-derived PRV metrics showed good correlations with ECG-derived HRV golden standards,in terms of absolute measurements and video game playing(VGP)-related changes.It was also observed that,similar to previous studies on physical activity and exercise,the PRV metrics closely related to parasympathetic activities recovered slower than the PRV indicators of sympathetic activities after VGP.It is concluded that it is feasible to use fNIRS to monitor concurrent brain and ANS activations during online VGP,facilitating the understanding of VGP-related heart–brain coupling. 展开更多
关键词 Heart rate variability pulse rate variability functional near-infrared spectroscopy video game prefrontal cortex heart–brain coupling
原文传递
The Change in Pulse Rate and Behavioral Score by Using Video Assisted Induction of Pediatric Anesthesia
4
作者 Yukako Abukawa Koichi Hiroki Makoto Ozaki 《Open Journal of Anesthesiology》 2016年第3期45-50,共6页
Purpose: Objective of this study was to determine whether video assisted anesthesia induction reduced pediatric patients’ stress. Methods: With approval from the local ethics committee and parental informed consent, ... Purpose: Objective of this study was to determine whether video assisted anesthesia induction reduced pediatric patients’ stress. Methods: With approval from the local ethics committee and parental informed consent, 75 children undergoing minor surgery were investigated in this prospective observational study. Patients were divided into three groups: group 1 was aged two to three years old, group 2 was aged four to six years old and group 3 was aged from seven to ten years old. The following three characteristics were evaluated: 1) the pulse rate at four points (the ward, the entrance at the operating room, mask notification and the mask fit);2) the behavioral score in the operating room;3) the amount of pain killers after the operation. Results: In group 1 (N = 20), there was a significant difference between the control group and the video assisted group regarding the percentage change in pulse rate based on the children’s ward when the patients looked at the mask. In group 2 (N = 26), there was no significant difference regarding any points. In group 3 (N = 29), there was a significant difference between control and video assisted group regarding the percentage change in pulse rate based on the children’s ward for all points. Also, regarding to the behavioral score, there was a significant difference between the control group and the video assisted group of all ages. However, there was no significant difference regarding the use of NSAIDs in the postoperative period between the control and the video assisted group. Conclusion: These results show that the video assisted anesthesia induction is effective for pediatric patients. 展开更多
关键词 Video Assisted Anesthesia Induction pulse rate Pediatric General Anesthesia
在线阅读 下载PDF
The 266-nm ultraviolet-beam generation of all-fiberized super-large-mode-area narrow-linewidth nanosecond amplifier with tunable pulse width and repetition rate 被引量:2
5
作者 Shun Li Ping-Xue Li +4 位作者 Min Yang Ke-Xin Yu Yun-Chen Zhu Xue-Yan Dong Chuan-Fei Yao 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第3期292-298,共7页
We report on a compact, stable, all-fiberized narrow-linewidth(0.045 nm) pulsed laser source emitting laser beam with a wavelength of 266 nm, and tunable pulse width and repetition rate. The system is based on all-fib... We report on a compact, stable, all-fiberized narrow-linewidth(0.045 nm) pulsed laser source emitting laser beam with a wavelength of 266 nm, and tunable pulse width and repetition rate. The system is based on all-fiberized nanosecond amplifier architecture, which consists of Yb-doped fiber preamplifiers and a super-large-mode-area Yb-doped fiber power amplifier. The fiber amplifier with a core of 50 μm is used to raise the threshold of the stimulated Brillouin scattering(SBS) effect and to obtain high output power and single pulse energy. Using lithium triborate(LBO) crystal and betabarium borate(BBO) crystal for realizing the second-harmonic generation(SHG) and fourth-harmonic generation(FHG),we achieve 17 μJ(1.73 W) and 0.66 μJ(66 mW), respectively, at wavelengths of 532 nm and 266 nm and a repetition rate of 100 kHz with pulse width of 4 ns. This source has great potential applications in fluorescence research and solar-blind ultraviolet optical communication. 展开更多
关键词 nanosecond all-fiber amplifier narrow-linewidth ultraviolet beam generation tunable pulse width and repetition rate
原文传递
Supercontinuum generation at 1.55 μm in an all-normal dispersion photonic crystal fiber with high-repetition-rate picosecond pulses 被引量:1
6
作者 徐永钊 韩涛 +2 位作者 宋建勋 凌东雄 李洪涛 《Optoelectronics Letters》 EI 2014年第6期463-466,共4页
We demonstrate the generation of supercontinuum(SC) spectrum covering S+C+L band of optical communication by injecting 1.4 ps optical pulses with center wavelength of 1552 nm and repetition rate of 10 GHz into an all-... We demonstrate the generation of supercontinuum(SC) spectrum covering S+C+L band of optical communication by injecting 1.4 ps optical pulses with center wavelength of 1552 nm and repetition rate of 10 GHz into an all-normal dispersion photonic crystal fiber(PCF) with length of 80 m. The experimental results are in good agreement with the numerical simulations, which are used to illustrate the SC generation dynamics by self-phase modulation and optical wave breaking(WB). 展开更多
关键词 Crystal whiskers Dispersion (waves) Optical fiber communication pulse repetition rate Self phase modulation Supercontinuum generation
原文传递
All-fiberized very-large-mode-area Yb-doped fiber based high-peak-power narrow-linewidth nanosecond amplifier with tunable pulse width and repetition rate
7
作者 Min Yang Ping-Xue Li +5 位作者 Dong-Sheng Wang Ke-Xin Yu Xue-Yan Dong Ting-Ting Wang Chuan-Fei Yao Wei-Xin Yang 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第11期343-349,共7页
We demonstrate an all-fiberized narrow-linewidth nanosecond amplifier with high peak power,tunable pulse width,and repetition rate.A fiber-coupled narrow-linewidth laser diode operating at 1064.1 nm is employed as the... We demonstrate an all-fiberized narrow-linewidth nanosecond amplifier with high peak power,tunable pulse width,and repetition rate.A fiber-coupled narrow-linewidth laser diode operating at 1064.1 nm is employed as the seed source,which is gain-switched to generate nanosecond pulses with tunable pulse widths of 1-200 ns and tunable repetition rates of10 Hz-100 kHz.By utilizing a very-large-mode-area Yb-doped fiber with a core diameter of 50 μm in the power amplifier,thresholds of the stimulated Brillouin scattering at different pulse widths and repetition rates are increased.The maximum average power reaches 30.8 W at the pulse width of 4 ns and a repetition rate of 100 kHz,corresponding to an optical-tooptical conversion efficiency of ~55.2%.Pulse energy and peak power are calculated to be 0.2 mJ and 50 kW,respectively,which are limited by stimulated Brillouin scattering.The 3-dB spectral linewidth remains around 0.05 nm during the power scaling process.The stimulated Brillouin scattering limited output powers at different pulse widths and repetition rates are investigated.Peak power of 47.5 kW(0.19 mJ) is obtained for the 4 ns pulses at a repetition rate of 50 kHz,which is nearly the same as that of 4 ns pulses at 100 kHz.When the pulse width of the seed source is increased to 8 ns,peak powers/pulse energies are decreased to 19.6 kW/0.11 mJ and 13.3 kW/0.08 mJ at repetition rates of 50 kHz and 100 kHz,respectively. 展开更多
关键词 nanosecond all-fiber amplifier very-large mode area tunable pulse width and repetition rate
原文传递
Impact of night sentry duties on cardiometabolic health in military personnel
8
作者 Haewon Byeon 《World Journal of Cardiology》 2025年第4期1-7,共7页
This article examines the study by Lin et al,which explores the effects of night sentry duties on cardiometabolic health in military personnel.The research identifies significant correlations between the frequency of ... This article examines the study by Lin et al,which explores the effects of night sentry duties on cardiometabolic health in military personnel.The research identifies significant correlations between the frequency of night shifts and nega-tive cardiometabolic outcomes,such as elevated resting pulse rates and lowered levels of high-density lipoprotein cholesterol.These outcomes underscore the health risks linked to partial sleep deprivation,a common challenge in military environments.The editorial highlights the clinical significance of these findings,advocating for the implementation of targeted health interventions to mitigate these risks.Strategies such as structured sleep recovery programs and lifestyle modifications are recommended to improve the health management of military personnel engaged in nocturnal duties.By addressing these issues,military health management can better safeguard the well-being and operational readiness of its personnel. 展开更多
关键词 Nocturnal duty Cardiometabolic health Military personnel Sleep deprivation Resting pulse rate High-density lipoprotein cholesterol Metabolic syndrome
暂未订购
Design of Calibration Device for Pulse Oximeter Simulator
9
作者 ZHANG Pu HONG Bao-yu CHEN Jing 《Chinese Journal of Biomedical Engineering(English Edition)》 2013年第4期161-168,共8页
Saturation of peripheral oxygen (SpO2) is one of the most important parameters of vital signs. Pulse oximeter based on near-infrared spectroscopy is commonly used as a non-invasive method to measure SpO2 yl. Current... Saturation of peripheral oxygen (SpO2) is one of the most important parameters of vital signs. Pulse oximeter based on near-infrared spectroscopy is commonly used as a non-invasive method to measure SpO2 yl. Currently, medical device manufacturers as well as metrology measurement agencies in China usually use pulse oximeter simulator as the commonly accepted functional calibration equipment for pulse oximeters. So far, no experimental protocol or devices can be used to test the accuracy and reliability of a pulse oximeter simulator. Therefore, a set of new metrology apparatus with the name of calibration device for pulse oximeter simulator have been designed in order to make a traceable system for the calibration or verification of pulse oximeter simulators. The principles and some research methods of this calibration device for pulse oximeter simulator will be discussed in this paper. Besides that, many experiments have been applied in order to guarantee the accuracy as well as traceability of this set of device. 展开更多
关键词 saturation of peripheral oxygen (SpO2) pulse oximeter simulator R-SpO2 curve standard sensors pulse rate
暂未订购
Research of photonic-assisted triangular-shaped pulses generation based on quadrupling RF modulation 被引量:1
10
作者 袁瑾 宁提纲 +3 位作者 李晶 李月琴 陈宏尧 张婵 《Optoelectronics Letters》 EI 2015年第3期207-212,共6页
We propose an approach to generate optical triangular-shaped pulse train with tunable repetition rate using quadrupling radio frequency(RF)modulation and optical grating dispersion-induced power fading.In this work,a ... We propose an approach to generate optical triangular-shaped pulse train with tunable repetition rate using quadrupling radio frequency(RF)modulation and optical grating dispersion-induced power fading.In this work,a piece of chirped fiber Bragg grating(FBG)is employed as the dispersive media to remove the undesired 8th harmonic in optical intensity.Thus,the generated harmonics of optical intensity can be corresponding to the first two Fourier components of typical periodic triangular pulses.This work also analyzes the impacts of the extinction ratio and the bias voltage drift on the harmonic distortion suppression ratio.After that,the value of the extinction ratio and the range of the bias voltage drift can be obtained.The advantage of this proposal is that it can generate high order frequency-multiplexed optical pulses train which can be applied in all optical signal processing and other fields. 展开更多
关键词 Bias voltage Fading (radio) Fiber Bragg gratings Fiber optic sensors Harmonic analysis Light extinction Modulation Optical signal processing pulse repetition rate Q switched lasers Signal processing
原文传递
Characterization of zirconium thin films deposited by pulsed laser deposition
11
作者 刘伟 万竟平 +3 位作者 蔡吴鹏 梁建华 周晓松 龙兴贵 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第9期496-501,共6页
Zirconium (Zr) thin films deposited on Si (100) by pulsed laser deposition (PLD) at different pulse repetition rates are investigated. The deposited Zr films exhibit a polycrystalline structure, and the X-ray di... Zirconium (Zr) thin films deposited on Si (100) by pulsed laser deposition (PLD) at different pulse repetition rates are investigated. The deposited Zr films exhibit a polycrystalline structure, and the X-ray diffraction (XRD) patterns of the films show the α Zr phase. Due to the morphology variation of the target and the laser-plasma interaction, the deposition rate significantly decreases from 0.0431 A/pulse at 2 Hz to 0.0189A/pulse at 20 Hz. The presence of droplets on the surface of the deposited film, which is one of the main disadvantages of the PLD, is observed at various pulse repetition rates. Statistical results show that the dimension and the density of the droplets increase with an increasing pulse repetition rate. We find that the source of droplets is the liquid layer formed under the target surface. The dense nanoparticles covered on the film surface are observed through atomic force microscopy (AFM). The root mean square (RMS) roughness caused by valleys and islands on the film surface initially increases and then decreases with the increasing pulse repetition rate. The results of our investigation will be useful to optimize the synthesis conditions of the Zr films. 展开更多
关键词 laser processing Zr thin film DROPLET pulse repetition rate
原文传递
Influence of Input Pulse Durations on Properties of Er^(3+)/Yb^(3+) Co-doped DCFA
12
作者 ZHAN Sheng-bao ZHAO Shang-hong SHI Lei XU Jie ZHAO Xiao-ming 《Semiconductor Photonics and Technology》 CAS 2006年第3期205-210,共6页
Based on propagation-rate equations, the influence of different input pulse durations on the properties of Er^3+/Yb^3+ co-doped double-clad fiber amplifier at dynamic equilibrium was analyzed. The change characteris... Based on propagation-rate equations, the influence of different input pulse durations on the properties of Er^3+/Yb^3+ co-doped double-clad fiber amplifier at dynamic equilibrium was analyzed. The change characteristic of output power sag with pulse duration and repetition rate was shown. Whether single or multichannel input pulses are amplified, the shorter the input pulse duration is, the smaller the power sags of output pulse will be. At low repetition rate, upper gain values(Gupper) of gain swing are almost the same for different input pulse durations, which tend to the small signal gain, but lower gain value(Glower) of short input pulse is larger than that of long input pulse. At highrepetition rate, lower gain value(Glower) approaches to upper gain value(Glower). 展开更多
关键词 Er^3+/Yb^3+ co-doped Double-clad fiber amplifier pulse duration pulse repetition rate
在线阅读 下载PDF
Effects of urban street trees on human thermal comfort and physiological indices: a case study in Changchun city, China 被引量:7
13
作者 Zhibin Ren Hongbo Zhao +2 位作者 Yao Fu Lu Xiao Yulin Dong 《Journal of Forestry Research》 SCIE CAS CSCD 2022年第3期911-922,共12页
Planting trees along urban streets is one of the most important strategies to improve the urban thermal environment.However,the net impacts of urban street trees on human thermal comfort and physiological parameters a... Planting trees along urban streets is one of the most important strategies to improve the urban thermal environment.However,the net impacts of urban street trees on human thermal comfort and physiological parameters are still less clear.On three similar east-west orientated streets with different degrees of tree cover-low(13%),medium(35%),and high(75%),urban microclimatic parameters and human physiological indices for six male students were simultaneously measured on three cloudless days in summer 2018.The results show that the differences in tree cover were predominant in influencing urban thermal environment and comfort.The street with the highest tree cover had significantly lower physiological equivalent temperature(PET) and more comfortable than the other two streets.The frequency of strong heat stress(PET> 35℃) was 64%,11 %,and 0%,respectively,for streets with low,medium,and high tree cover.For the six male university students,human physiological indices varied greatly across the three streets with different tree cover.Systolic blood pressure,diastolic blood pressure,and pulse rate increased with decreasing tree cover.The results also suggest that urban thermal environment and comfort had considerable impact on human physiological parameters.Our study provides reasons for urban planners to plant trees along streets to improve the thermal environment and promote urban sustainability. 展开更多
关键词 Urban forest Green space Environmental ecosystem services Urban thermal comfort Blood pressure pulse rate
在线阅读 下载PDF
Design of Online Vitals Monitor by Integrating Big Data and IoT
14
作者 E.Afreen Banu V.Rajamani 《Computer Systems Science & Engineering》 SCIE EI 2023年第3期2469-2487,共19页
In this work,we design a multisensory IoT-based online vitals monitor(hereinafter referred to as the VITALS)to sense four bedside physiological parameters including pulse(heart)rate,body temperature,blood pressure,and... In this work,we design a multisensory IoT-based online vitals monitor(hereinafter referred to as the VITALS)to sense four bedside physiological parameters including pulse(heart)rate,body temperature,blood pressure,and periph-eral oxygen saturation.Then,the proposed system constantly transfers these signals to the analytics system which aids in enhancing diagnostics at an earlier stage as well as monitoring after recovery.The core hardware of the VITALS includes commercial off-the-shelf sensing devices/medical equipment,a powerful microcontroller,a reliable wireless communication module,and a big data analytics system.It extracts human vital signs in a pre-programmed interval of 30 min and sends them to big data analytics system through the WiFi module for further analysis.We use Apache Kafka(to gather live data streams from connected sen-sors),Apache Spark(to categorize the patient vitals and notify the medical pro-fessionals while identifying abnormalities in physiological parameters),Hadoop Distributed File System(HDFS)(to archive data streams for further analysis and long-term storage),Spark SQL,Hive and Matplotlib(to support caregivers to access/visualize appropriate information from collected data streams and to explore/understand the health status of the individuals).In addition,we develop a mobile application to send statistical graphs to doctors and patients to enable them to monitor health conditions remotely.Our proposed system is implemented on three patients for 7 days to check the effectiveness of sensing,data processing,and data transmission mechanisms.To validate the system accuracy,we compare the data values collected from established sensors with the measured readouts using a commercial healthcare monitor,the Welch Allyn®Spot Check.Our pro-posed system provides improved care solutions,especially for those whose access to care services is limited. 展开更多
关键词 Big data analytics blood pressure body temperature physiological parameters pulse rate sensors SPO2
在线阅读 下载PDF
Photoacoustic Doppler flowmetry of carbon particles flow using an autocorrelation method 被引量:2
15
作者 卢涛 《Optoelectronics Letters》 EI 2014年第6期467-469,共3页
In order to measure the axial flowing velocity of carbon particle suspension with particle diameter of tens of micrometers, the photoacoustic Doppler(PAD) frequency shift is calculated based on a series of individual ... In order to measure the axial flowing velocity of carbon particle suspension with particle diameter of tens of micrometers, the photoacoustic Doppler(PAD) frequency shift is calculated based on a series of individual A scans using an autocorrelation method. A 532 nm pulsed laser with repetition rate of 20 Hz is used as a pumping source to generate photoacoustic signal. The photoacoustic signals are detected using a focused piezoelectric(PZT) ultrasound transducer with central frequency of 5 MHz. The suspension of carbon particles is driven by a syringe pump. The complex photoacoustic signal is calculated by the Hilbert transformation from time-domain photoacoustic signal, and then it is autocorrelated to calculate the Doppler frequency shift. The photoacoustic Doppler frequency shift is calculated by averaging the autocorrelation results of some individual A scans. The advantage of the autocorrelation method is that the time delay in autocorrelation can be defined by user, and the requirement of high pulse repetition rate is avoided. The feasibility of the proposed autocorrelation method is preliminarily demonstrated by quantifying the motion of a carbon particle suspension with flow velocity from 5 mm/s to 60 mm/s. The experimental results show that there is an approximately linear relation between the autocorrelation result and the setting velocity. 展开更多
关键词 AUTOCORRELATION CARBON Doppler effect Flow velocity Frequency shift keying Mathematical transformations Optical pumping pulse repetition rate Time delay Time domain analysis Ultrasonic transducers
原文传递
The adaptive value of increasing pulse repetition rate during hunting by echolocating bats
16
作者 Philip H.-S. JEN 《Frontiers in Biology》 CAS CSCD 2013年第2期198-215,共18页
During hunting, bats of suborder Microchiropetra emit intense ultrasonic pulses and analyze the weak returning echoes with their highly developed auditory system to extract the information about insects or obstacles. ... During hunting, bats of suborder Microchiropetra emit intense ultrasonic pulses and analyze the weak returning echoes with their highly developed auditory system to extract the information about insects or obstacles. These bats progressively shorten the duration, lower the frequency, decrease the intensity and increase the repetition rate of emitted pulses as they search, approach, and finally intercept insects or negotiate obstacles. This dynamic variation in multiple parameters of emitted pulses predicts that analysis of an echo parameter by the bat would be inevitably affected by other co-varying echo parameters. The progressive increase in the pulse repetition rate throughout the entire course of hunting would presumably enable the bat to extract maximal information from the increasing number of echoes about the rapid changes in the target or obstacle position for successful hunting. However, the increase in pulse repetition rate may make it difficult to produce intense short pulse at high repetition rate at the end of long-held breath. The increase in pulse repetition rate may also make it difficult to produce high frequency pulse due to the inability of the bat laryngeal muscles to reach its full extent of each contraction and relaxation cycle at a high repetition rate. In addition, the increase in pulse repetition rate increases the minimum threshold (i.e. decrease auditory sensitivity) and the response latency of auditory neurons. In spite of these seemingly physiological disadvantages in pulse emission and auditory sensitivity, these bats do progressively increase pulse repetition rate throughout a target approaching sequence. Then, what is the adaptive value of increasing pulse repetition rate during echolocation? What are the underlying mechanisms for obtaining maximal information about the target features during increasing pulse repetition rate? This article reviews the electrophysiological studies of the effect of pulse repetition rate on multiple- parametric selectivity of neurons in the central nucleus of the inferior colliculus of the big brown bat, Eptesicusfuscus using single repetitive sound pulses and temporally patterned trains of sound pulses. These studies show that increasing pulse repetition rate improves multiple-parametric selectivity of inferior collicular neurons. Conceivably, this improvement of multiple-parametric selectivity of collicular neurons with increasing pulse repetition rate may serve as the underlying mechanisms for obtaining maximal information about the prey features for successful hunting by bats. 展开更多
关键词 BAT ECHOLOCATION inferior colliculus multiple-parametric selectivity pulse repetition rate
原文传递
An LD-pumped dual-wavelength actively Q-switched Nd:Sc_(0.2)Y_(0.8)SiO_5 laser
17
作者 杨秀芹 马志国 +2 位作者 郑丽和 尚连聚 苏富芳 《Optoelectronics Letters》 EI 2015年第2期92-94,共3页
We demonstrate a laser-diode (LD) pumped actively Q-switched laser with Nd:Sc0.2Y0.5SiO5 (Nd:SYSO) crystal for the first time. A stable actively Q-switched laser is obtained at dual wavelengths of 1 075.2 nm and... We demonstrate a laser-diode (LD) pumped actively Q-switched laser with Nd:Sc0.2Y0.5SiO5 (Nd:SYSO) crystal for the first time. A stable actively Q-switched laser is obtained at dual wavelengths of 1 075.2 nm and 1 078.2 nm. The maximum average output power of 720 mW is obtained at the repetition rate of 15 kHz under the pump power of 8.7 W. The minimum pulse width of 58 ns is obtained at the repetition rate of 5 kHz under the pump power of 8.7 W, corresponding to the peak power of 1.9 kW and the pulse energy of 112 μJ. 展开更多
关键词 BIOASSAY Microarrays Optical pumping pulse repetition rate Q switched lasers Q switching
原文传递
Short mid-infrared watt-level all-fiber nonlinear pulse compressor above 100-MHz pulse repetition rate
18
作者 Jingcheng Shang Chao Mei +5 位作者 Shengzhi Zhao Yizhou Liu Kejian Yang Chun Wang Tao Li Tianli Feng 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2023年第1期107-113,共7页
We firstly report a 2-μm all-fiber nonlinear pulse compressor based on two pieces of normal dispersion fiber(NDF),which enables a high-power scaling ability of watt-level and a high pulse compression ratio of 13.7.Wi... We firstly report a 2-μm all-fiber nonlinear pulse compressor based on two pieces of normal dispersion fiber(NDF),which enables a high-power scaling ability of watt-level and a high pulse compression ratio of 13.7.With the NDFbased all-fiber nonlinear pulse compressor,the 450-fs laser pulses with a repetition rate of 101.4 MHz are compressed to 35.1 fs,corresponding to a 5.2 optical oscillation cycle at the 2-μm wavelength region.The output average power reaches 1.28 W,which is believed to be the highest value never achieved from the previous 2-μm all-fiber nonlinear pulse compressors with a high pulse repetition rate above 100 MHz.The dynamic evolution of the ultrafast pulse inside the all-fiber nonlinear pulse compressor is numerically analyzed,matching well with the experimental results. 展开更多
关键词 few-optical-cycle pulses high pulse repetition rate nonlinear pulse compression
原文传递
Effect of dilution rate on dynamic and steady-state biofilm characteristics during phenol biodegradation by immobilized Pseudomonas desmolyticum cells in a pulsed plate bioreactor
19
作者 Veena Bangalore Rangappa Vidya Shetty Kodialbail Saidutta Malur Bharthaiyengar 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2016年第4期81-89,共9页
Pulsed plate bioreactor (PPBR) is a biofilm reactor which has been proven to be very efficient in phenol biodegradation. The present paper reports the studies on the effect of dilution rate on the physical, chemical... Pulsed plate bioreactor (PPBR) is a biofilm reactor which has been proven to be very efficient in phenol biodegradation. The present paper reports the studies on the effect of dilution rate on the physical, chemical and morphological characteristics of biofilms formed by the cells of Pseudomonas desmolyticum on granular activated carbon (GAC) in PPBR during biodegradation of phenol. The percentage degradation of phenol decreased from 99% to 73% with an increase in dilution rate from 0.33 h^-1 to 0.99 h^-1 showing that residence time in the reactor governs the phenol removal efficiency rather than the external mass transfer limitations. Lower dilution rates favor higher production of biomass, extracellular polymeric substances (EPS) as well as the protein, carbohydrate and humic substances content of EPS. Increase in dilution rate leads to decrease in biofilm thickness, biofilm dry density, and attached dry biomass, transforming the biofilm from dense, smooth compact structure to a rough and patchy structure. Thus, the performance of PPBR in terms of dynamic and steady-state biofilm characteristics associated with phenol biodegradation is a strong function of dilution rate. Operation of PPBR at lower dilution rates is recommended for continuous biological treatment of wastewaters for phenol removal. 展开更多
关键词 Biofilm Exopolymeric substances PhenolDilution rate pulsed plate bioreactor
原文传递
A compact Tirsapphire femtosecond pulse amplifier without stretcher at high repetition rate
20
作者 程光华 于连君 +3 位作者 王屹山 刘青 陈国夫 赵卫 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第4期225-227,共3页
We report a simple approach to amplify Ti:sapphire femtosecond pulses to moderate energy levels by a chirped regenerative amplifier. The seed pulses are broaden naturally because of the material dispersion of system c... We report a simple approach to amplify Ti:sapphire femtosecond pulses to moderate energy levels by a chirped regenerative amplifier. The seed pulses are broaden naturally because of the material dispersion of system components in regenerative cavity. The off-focusing Ti:sapphire crystal avoids effectively the optical damage. It sustains amplification over a wavelength range from 775 nm to more than 810 nm with a birefringent filter and an oscillation bandwidth of 7.7 nm, and produces 2.1 ps chirped output pulse energy of 100 uJ at 1.1-mJ pumping energy. This system shows good performances in stability and efficiency with the benefits of two thin-film polarizers and TEMoo mode pumping laser. 展开更多
关键词 A compact Tirsapphire femtosecond pulse amplifier without stretcher at high repetition rate it on with of high Ti 米米 into from THAN have
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部