期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Detection and Genesis Analysis of Cracks in Prestressed Box Girder of a Certain Project
1
作者 Mingnan Ji 《World Journal of Engineering and Technology》 2024年第4期1075-1082,共8页
This paper introduces a crack detection example of the prestressed box girder in a certain project. The morphology of the box girder cracks was surveyed and mapped. The length, width, and depth of the cracks were insp... This paper introduces a crack detection example of the prestressed box girder in a certain project. The morphology of the box girder cracks was surveyed and mapped. The length, width, and depth of the cracks were inspected, and the strength and reinforcement configuration of the components were tested. The test results indicate that the strength and reinforcement configuration of the inspected components meet the design requirements. The crack at the end of the top plate of the box girder is a local compressive crack at the anchorage end. The width and length of the crack on the bottom surface of the top plate are not significant, and the depth is relatively shallow. Judging from the crack morphology, this crack is identified as a temperature crack. Additionally, based on the treatment measures for cracks of different widths, the treatment measures for the cracks of the components in this project are derived, providing a reference basis for similar projects in the future. 展开更多
关键词 prestressed box girder Crack Detection Cause Analysis Treatment Measures
在线阅读 下载PDF
Finite element failure analysis of continuous prestressed concrete box girders 被引量:4
2
作者 张峰 李术才 +2 位作者 李树忱 叶见曙 雷笑 《Journal of Southeast University(English Edition)》 EI CAS 2009年第2期236-240,共5页
In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a... In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a finite failure analysis method for predicting behaviors of box girders is developed. A degenerated solid shell element is used to simulate box girders and material nonlinearity is considered. Since pre-stressed concrete box girders usually have a large number of curve prestressed tendons, a type of combined element is presented to simulate the prestressed tendons of box girders, and then the number of elements can be significantly reduced. The analytical results are compared with full-scale failure test results. The comparison shows that the presented method can be effectively applied to the failure analysis of in-situ continuous prestressed concrete box girders, and it also shows that the studied old bridge still has enough load carrying capacity. 展开更多
关键词 full-scale failure test prestressed concrete box girder finite element analysis combined element prestressed tendon load carrying capacity
在线阅读 下载PDF
Discussion on Detection and Evaluation of Simply Supported Prestressed Concrete Small Box Girder Bridge After a Fire
3
作者 Qing Yang Jiang Feng 《Journal of Architectural Research and Development》 2024年第2期108-113,共6页
The article takes a simply supported prestressed concrete small box girder bridge project as an example for inspection and evaluation after a fire incident.This includes appearance detection,concrete color hardness de... The article takes a simply supported prestressed concrete small box girder bridge project as an example for inspection and evaluation after a fire incident.This includes appearance detection,concrete color hardness detection,concrete strength detection,concrete surface damage layer detection,reinforcement protective layer detection,and concrete carbonation detection.It is hoped that this analysis can be used as a reference for the detection and evaluation of future bridge projects with fire incidents to smoothen its subsequent repair and maintenance. 展开更多
关键词 prestressed concrete box girder Simply supported small box girder Fire damage Concrete testing Reinforcement testing
在线阅读 下载PDF
Discussion on Application of Construction Technology of Cast-in-Place Box Girder
4
作者 ZHANG Qi 《外文科技期刊数据库(文摘版)工程技术》 2021年第4期774-786,共13页
Combined with the construction of prestressed continuous box girder of Bailongjiang super large bridge in Xiazongjiaba of WJSJ2 contract section of G8513 Pingliang to Mianyang national expressway and Wudu to Jiuzhaigo... Combined with the construction of prestressed continuous box girder of Bailongjiang super large bridge in Xiazongjiaba of WJSJ2 contract section of G8513 Pingliang to Mianyang national expressway and Wudu to Jiuzhaigou (Ganchuan boundary), this paper analyzed the application of prestressed continuous box girder support formwork design, concrete pouring technology, prestressed steel tendon tension sequence and vacuum assisted grouting technology. 展开更多
关键词 prestressed continuous box girder bracket formwork tension vacuum grouting application of constr
原文传递
上一页 1 下一页 到第