硅凝胶襻板式人工晶状体在YAG激光晶状体囊膜切开术后迟发性后脱位(英文)
1
作者 KI Papageorgiou A Ioannidis +1 位作者 AJ Sinha PS Andreou 《国际眼科杂志》 CAS 2006年第6期1249-1251,共3页
目的:观察白内障手术植入硅凝胶襻板式人工晶状体的稳定性,分析其偏心和后脱位的相关原因。方法-结果:我们报道了3例顺利行白内障超声乳化并硅凝胶襻板式人工晶状体植入手术的患者,在术后发生人工晶状体后脱位。1例出现在因高度前囊收... 目的:观察白内障手术植入硅凝胶襻板式人工晶状体的稳定性,分析其偏心和后脱位的相关原因。方法-结果:我们报道了3例顺利行白内障超声乳化并硅凝胶襻板式人工晶状体植入手术的患者,在术后发生人工晶状体后脱位。1例出现在因高度前囊收缩行扇形晶状体前囊切开术后4a,另2例分别出现在晶状体后囊切开术后早期和术后3mo。3者均在顺利行晶状体后囊切开术后发生脱离。患者均无外伤病史或其他促发事件。结论:硅凝胶襻板式人工晶状体似乎由于较差的囊粘附性易于脱位,因为它们仅是通过襻的纤维变性融合而固定。如果前囊或后囊破裂,囊收缩产生的力量可以导致放射状撕裂的扩展,进而引起植入晶状体的后脱位。尽管其他类型人工晶状体在这方面优于硅凝胶襻板式人工晶状体,但是已植入此种人工晶状体,在进行YAG激光晶状体囊切开术时,告知他们潜在人工晶状体后脱位风险是术后早期或晚期并发症是非常重要的。 展开更多
关键词 硅凝胶襻板式人工晶状体 YAG激光 囊膜切开术 后脱位
暂未订购
The influence of a modified haptic on preventing toric IOL rotation in high rotation risk eyes
2
作者 Shuyu Liu Chao Chen +6 位作者 Jitong Zhou Kaiwen Cheng Yu Du Jiaqi Meng Yi Lu Wenwen He Xiangjia Zhu 《Advances in Ophthalmology Practice and Research》 2026年第1期50-55,共6页
Purposes:To evaluate the rotational stability and astigmatic correction of a C-loop frosted haptic toric intraocular lens(IOL)compared with a plate-haptic toric IOL with/without capsular tension ring(CTR)implantation ... Purposes:To evaluate the rotational stability and astigmatic correction of a C-loop frosted haptic toric intraocular lens(IOL)compared with a plate-haptic toric IOL with/without capsular tension ring(CTR)implantation in cataractous eyes with high rotation risk due to large white-to-white(WTW)distance.Methods:This retrospective cohort study included 90 cataractous eyes with WTW>11.8 mm,which received implantation of either a C-loop frosted haptic toric IOL(Group ZCU),a plate-haptic toric IOL(Group 709),or a plate-haptic toric IOL with CTR(Group 709+CTR).IOL rotation and residual astigmatism were assessed one month postoperatively.Results:Group ZCU demonstrated significantly better rotational stability,with a mean rotation of 1.87°±1.03°,compared to 4.63°±2.12°in Group 709 and 4.13°±1.86°in Group 709+CTR(both P<0.05).Residual astigmatism was also significantly lower in Group ZCU(0.36±0.26 D),compared to Group 709(0.54±0.43 D)and Group 709+CTR(0.65±0.27 D;both P<0.05).A positive correlation between WTW and IOL rotation was found in Group 709(r=0.419,P=0.021)and Group 709+CTR(r=0.403,P=0.027),but not in Group ZCU(r=-0.180,P=0.341).Lens thickness and WTW were identified as independent predictors of rotation in Group 709,whereas only WTW was significant in Group 709+CTR.Conclusions:In eyes with high rotation risk due to large WTW(>11.8 mm),the ZCU IOL exhibits superior rotational stability and astigmatic correction compared to the 709 IOL,regardless of whether CTR is used. 展开更多
关键词 White-to-white Toric intraocular lens Rotational stability C-loop frosted haptic plate-haptic