The electrochemical behavior of the medical Stainless steel 317L which is used as in vivo fixation materials has been investigated at different passivated states in several candidate-testing solutions. The potentiodyn...The electrochemical behavior of the medical Stainless steel 317L which is used as in vivo fixation materials has been investigated at different passivated states in several candidate-testing solutions. The potentiodynamic scanning polarizaion technique was employed to measure the polarizaion curves of 317L in 0.9%NaCl solution at 37℃. The results showed that the electrochemical behaviorin 0.9% NaCl solution at 37℃ and in 2% NaCl solotion at 30℃ can be better used to detect and evaluate passivated states and corrosionresistance of 317L. In addition,the pitting potential Eb can be used as a criterion and itS lower limit could be 0.85 V(SEC) for this system.展开更多
文摘The electrochemical behavior of the medical Stainless steel 317L which is used as in vivo fixation materials has been investigated at different passivated states in several candidate-testing solutions. The potentiodynamic scanning polarizaion technique was employed to measure the polarizaion curves of 317L in 0.9%NaCl solution at 37℃. The results showed that the electrochemical behaviorin 0.9% NaCl solution at 37℃ and in 2% NaCl solotion at 30℃ can be better used to detect and evaluate passivated states and corrosionresistance of 317L. In addition,the pitting potential Eb can be used as a criterion and itS lower limit could be 0.85 V(SEC) for this system.