期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Willis covered stent in the treatment of a recurrent blood blister-like aneurysm after pipeline implementation:A case report 被引量:2
1
作者 Yu Fu Feng Fan +1 位作者 Jing Li Sheng Guan 《Journal of Interventional Medicine》 2023年第2期96-98,共3页
Blood blister-like aneurysms(BBAs)are fragile and difficult to treat.However,the optimal treatment has yet to be determined.Pipeline embolization devices and Willis covered stent implementation are still controversial... Blood blister-like aneurysms(BBAs)are fragile and difficult to treat.However,the optimal treatment has yet to be determined.Pipeline embolization devices and Willis covered stent implementation are still controversial strategies for treating BBA.Herein,we report a case of recurrent BBA successfully treated with a Willis covered stent.A long-term follow-up angiography after the procedure indicated complete occlusion of the aneurysm.This case demonstrates the safety and efficacy of applying the Wills cover stent in the treatment of recurrent BBA after Pipeline implantation. 展开更多
关键词 Blood blister-like aneurysm Endovascular therapy pipeline embolization device Willis covered stent
暂未订购
Pipeline versus Tubridge in the treatment of unruptured posterior circulation aneurysms 被引量:2
2
作者 Hengwei Jin Jian Lv +3 位作者 Xiangyu Meng Xinke Liu Hongwei He Youxiang Li 《Chinese Neurosurgical Journal》 CAS CSCD 2023年第4期251-257,共7页
Background To compare the safety and efficacy of pipeline embolization device(PED)and Tubridge flow diverter(TFD)for unruptured posterior circulation aneurysms.Methods Posterior aneurysm patients treated with PED or T... Background To compare the safety and efficacy of pipeline embolization device(PED)and Tubridge flow diverter(TFD)for unruptured posterior circulation aneurysms.Methods Posterior aneurysm patients treated with PED or TFD between January,2019,and December,2021,were retrospectively reviewed.Patients’demographics,aneurysm characteristics,treatment details,complications,and follow-up information were collected.The procedural-related complications and angiographic and clinical outcome were compared.Results A total of 107 patients were involved;PED was applied for 55 patients and TFD for 52 patients.A total of 9(8.4%)procedural-related complications occurred,including 4(7.3%)in PED group and 5(9.6%)in TFD group.During a mean of 10.3-month angiographic follow-up for 81 patients,complete occlusion was achieved in 35(85.4%)patients in PED group and 30(75.0%)in TFD group.The occlusion rate of PED group is slightly higher than that of TFD group.A mean of 25.0-month clinical follow-up for 107 patients showed that favorable clinical outcome was achieved in 53(96.4%)patients in PED group and 50(96.2%)patients in TFD group,respectively.No statistical difference was found in terms of procedural-related complications(p=0.737),occlusion rate(p=0.241),and favorable clinical outcome(0.954)between groups.Conclusions The current study found no difference in complication,occlusion,and clinical outcome between PED and TFD for unruptured PCAs. 展开更多
关键词 pipeline embolization device Tubridge flow diverter Posterior circulation aneurysm
原文传递
Pipeline for previously stented basilar trunk aneurysm:a case focusing on how the pipeline should be deployed
3
作者 Fei Liang Yupeng Zhang +2 位作者 Yuntao Di Feng Guo Chuhan Jiang 《Chinese Neurosurgical Journal》 CSCD 2019年第1期56-59,共4页
Background:Recurrent,previously stented basilar trunk aneurysms pose significant challenges to either microsurgical clipping or traditional endovascular treatment.We here presented an intriguing case that was successf... Background:Recurrent,previously stented basilar trunk aneurysms pose significant challenges to either microsurgical clipping or traditional endovascular treatment.We here presented an intriguing case that was successfully treated by the pipeline embolization device(PED;ev3/Covidien Neurovascular,Irvine,California,USA).Case presentation:A 62-year-old male found a recurrent aneurysm,which had been treated with coiling and stentassisted coiling before.The patient came to our center seeking for a third treatment.In our center,a single PED and additional coils were used to treat this refractory aneurysm.The whole length of the PED was delicately implanted in the previous Enterprise stent(Cordis Corporation,Miami FL,USA),which resembled the double-layer flow diverter FRED(Microvention,Tustin,California,USA).The inflow zone of the aneurysmal sac was further coiled considering that this aneurysm had ruptured.No procedure-related complications occurred.Follow-up angiogram at 6 months indicated that the intractable aneurysm was completely occluded and the patient was free from any neurologic deficit.Conclusions:This is a case that adds knowledge to improve the poor performance of flow diverters in previously stented aneurysms.However,future studies with larger group of patients are needed to further test the safety and efficacy of this technique. 展开更多
关键词 Previously stented aneurysm Basilar artery pipeline embolization device
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部