The Seebeck coefficient is determined from silicon microchannel plates (Si MCPs) prepared by photo- assisted electrochemical etching at room temperature (25 ℃). The coefficient of the sample with a pore size of 5...The Seebeck coefficient is determined from silicon microchannel plates (Si MCPs) prepared by photo- assisted electrochemical etching at room temperature (25 ℃). The coefficient of the sample with a pore size of 5 × 5μm^2, spacing of 1 μm and thickness of about 150 μm is -852μV/K along the edge of the square pore. After doping with boron and phosphorus, the Seebeck coefficient diminishes to 256 μV/K and -117 μV/K along the edge of the square pore, whereas the electrical resistivity values are 7.5 × 10^-3 Ω·cm and 1.9 × 10^-3 Ω·cm, respectively. Our data imply that the Seebeck coefficient of the Si MCPs is related to the electrical resistivity and is consistent with that of bulk silicon. Based on the boron and phosphorus doped samples, a simple device is fabricated to connect the two type Si MCPs to evaluate the Peltier effect. When a proper current passes through the device, the Peltier effect is evidently observed. Based on the experimental data and the theoretical calculation, the estimated intrinsic figure of merit ZT of the unicouple device and thermal conductivity of the Si MCPs are 0.007 and 50 W/(m.K), respectively.展开更多
Thermoelectric air conditioning systems based on the Peltier effect had two modes:heating and cooling.In this work,the proposed design provides continuous improvement in COP from the first minute of operation.In cooli...Thermoelectric air conditioning systems based on the Peltier effect had two modes:heating and cooling.In this work,the proposed design provides continuous improvement in COP from the first minute of operation.In cooling mode,the coefficient of performance(COP)was 1.176 due to the techniques used in this device,and it increased to 1.24 in the last minute of operation.Concerning the steady-state scenario,from the first minute,the Qc was larger than the W for the entire duration of the operation.The output temperature reaches 18.97℃ ,and the temperature on the cold side reaches 4.96℃ in the fifteen minutes of operation.The cooling mood was checked in Iraq/Baghdad in October with a temperature of 31℃ .Furthermore,the heating mode was checked in December with a temperature of 22℃ .Due to the size of the component on the cold side being small compared with the size of the component on the heat side,it reached a steady state in 13 min.This means the COP in heating mode reached 1.01 in 14 min.Furthermore,due to the presence of a thermal insulator made inside the device to separate the cold side and the hot side,the difference in temperature causes a noticeable little ascent.This is why the COP increased because it kept the degree differences low.Performance enhancements were achieved by optimizing the behavior of thermoelectric materials.The device contains 3 Peltier elements,a water-cooled system with one Peltier,a heat sink,and a fan.The design of the dehumidification system addresses the humidity issue commonly associated with thermoelectric air conditioners.In this context,the results indicate that the humidity rates had decreased and the cooling rate had increased with these innovative techniques,and thus,excellent performance can be achieved even if the Seebeck coefficient is not at its highest based on the condition of providing the Peltier elements’reliability and optimal thermal performance for various applications requiring both cooling and heating functions.The insulation plays a critical role in maintaining the efficiency of the system,reducing energy consumption,and ensuring long-term functionality.The proposed system is valuable for devices or environments that demand precise and dual thermal control with minimal energy wastage.展开更多
The asymmetric thermo-physical mechanism of the resistance spot welding technique with intermediate frequency(2 kHz)and direct current(RSWIFDC)on the high strength aluminum(Al)alloy TL091 was studied here in view of t...The asymmetric thermo-physical mechanism of the resistance spot welding technique with intermediate frequency(2 kHz)and direct current(RSWIFDC)on the high strength aluminum(Al)alloy TL091 was studied here in view of the Peltier effect.On the basis of the analysis of the electrode cap surface erosion state and the shape-position of the nugget,it was concluded that asymmetric thermo-physical phenomenon occurred on both ends of the nugget,and even had an influence upon the shape-forming coefficient and the vertical position deviation of the nugget,and the erosion degree of the electrode caps.In this work,the relative thermo-physical model of the welding was established combined with the Peltier effect and the spot welding characteristics.Accordingly the relative welding phenomena,such as nugget center deviation and different erosion degree of the electrode cap surface,was explained clearly using the model related with the Peltier effect for the first time.This model provides important theoretical basis for future study and application of Al alloy spot welding,based on which,effective works may be done to promote the quality of the Al alloy welded joints and to obtain favorable control upon parameters of Al alloy welding for electrode caps.展开更多
基金Project supported by the Shanghai Fundamental Key Project(No.10JC1404600)the Shanghai Natural Science Foundation(No. 11ZR1411000)+3 种基金the Innovation Program of Shanghai Municipal Education Commission(No.09ZZ46)the International Collaboration Project(No.10520704400)the National Natural Science Foundation of China(Nos.60990312,61076060,61176108)the City University of Hong Kong Strategic Research Grant(SRG)(No.7008009).
文摘The Seebeck coefficient is determined from silicon microchannel plates (Si MCPs) prepared by photo- assisted electrochemical etching at room temperature (25 ℃). The coefficient of the sample with a pore size of 5 × 5μm^2, spacing of 1 μm and thickness of about 150 μm is -852μV/K along the edge of the square pore. After doping with boron and phosphorus, the Seebeck coefficient diminishes to 256 μV/K and -117 μV/K along the edge of the square pore, whereas the electrical resistivity values are 7.5 × 10^-3 Ω·cm and 1.9 × 10^-3 Ω·cm, respectively. Our data imply that the Seebeck coefficient of the Si MCPs is related to the electrical resistivity and is consistent with that of bulk silicon. Based on the boron and phosphorus doped samples, a simple device is fabricated to connect the two type Si MCPs to evaluate the Peltier effect. When a proper current passes through the device, the Peltier effect is evidently observed. Based on the experimental data and the theoretical calculation, the estimated intrinsic figure of merit ZT of the unicouple device and thermal conductivity of the Si MCPs are 0.007 and 50 W/(m.K), respectively.
文摘Thermoelectric air conditioning systems based on the Peltier effect had two modes:heating and cooling.In this work,the proposed design provides continuous improvement in COP from the first minute of operation.In cooling mode,the coefficient of performance(COP)was 1.176 due to the techniques used in this device,and it increased to 1.24 in the last minute of operation.Concerning the steady-state scenario,from the first minute,the Qc was larger than the W for the entire duration of the operation.The output temperature reaches 18.97℃ ,and the temperature on the cold side reaches 4.96℃ in the fifteen minutes of operation.The cooling mood was checked in Iraq/Baghdad in October with a temperature of 31℃ .Furthermore,the heating mode was checked in December with a temperature of 22℃ .Due to the size of the component on the cold side being small compared with the size of the component on the heat side,it reached a steady state in 13 min.This means the COP in heating mode reached 1.01 in 14 min.Furthermore,due to the presence of a thermal insulator made inside the device to separate the cold side and the hot side,the difference in temperature causes a noticeable little ascent.This is why the COP increased because it kept the degree differences low.Performance enhancements were achieved by optimizing the behavior of thermoelectric materials.The device contains 3 Peltier elements,a water-cooled system with one Peltier,a heat sink,and a fan.The design of the dehumidification system addresses the humidity issue commonly associated with thermoelectric air conditioners.In this context,the results indicate that the humidity rates had decreased and the cooling rate had increased with these innovative techniques,and thus,excellent performance can be achieved even if the Seebeck coefficient is not at its highest based on the condition of providing the Peltier elements’reliability and optimal thermal performance for various applications requiring both cooling and heating functions.The insulation plays a critical role in maintaining the efficiency of the system,reducing energy consumption,and ensuring long-term functionality.The proposed system is valuable for devices or environments that demand precise and dual thermal control with minimal energy wastage.
文摘The asymmetric thermo-physical mechanism of the resistance spot welding technique with intermediate frequency(2 kHz)and direct current(RSWIFDC)on the high strength aluminum(Al)alloy TL091 was studied here in view of the Peltier effect.On the basis of the analysis of the electrode cap surface erosion state and the shape-position of the nugget,it was concluded that asymmetric thermo-physical phenomenon occurred on both ends of the nugget,and even had an influence upon the shape-forming coefficient and the vertical position deviation of the nugget,and the erosion degree of the electrode caps.In this work,the relative thermo-physical model of the welding was established combined with the Peltier effect and the spot welding characteristics.Accordingly the relative welding phenomena,such as nugget center deviation and different erosion degree of the electrode cap surface,was explained clearly using the model related with the Peltier effect for the first time.This model provides important theoretical basis for future study and application of Al alloy spot welding,based on which,effective works may be done to promote the quality of the Al alloy welded joints and to obtain favorable control upon parameters of Al alloy welding for electrode caps.