The asymmetric dual-three phase BLDC motor has two sets of stator windings,in which the back EMF coefficients are different.This paper takes advantage of the asymmetric dual-three phase BLDC motor’s structural featur...The asymmetric dual-three phase BLDC motor has two sets of stator windings,in which the back EMF coefficients are different.This paper takes advantage of the asymmetric dual-three phase BLDC motor’s structural features and proposes a new method for the accelerated problem of the BLDC motor operating in the high speed and the constant electromagnetic power.The dual phase windings of the BLDC motor are integrated into the circuit in the starting stage.When the motor’s back EMF value is equal to the terminal voltage value,switch off a set of RST three phase windingswhose back EMF coefficient is bigger and make the other set of stator windingUVWwith smaller back EMF coefficient continue to operate under the rated power.As the motor rotor speed continues to increase,the electromagnetic torque remains unchanged.By using the peak current control strategy,we can deduce that the phase current of the UVW three-phase winding is twice the RSTthree-phase windingwhen the asymmetric dual-three phase BLDC motor operates at high speed and constant power.展开更多
The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases...The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases. As a result, the safety operation of the switches is damaged greatly. A novel solution to improve over-current protection with constant peak current limitation is proposed by inducing synchronous slope compensation into the current limit function instead of the original constant voltage. The design principle and method of the protection circuit based on a UC3846 PWM controller for the interleaved dual-forward converter is presented. Experimental results are given to verify the analysis.展开更多
为提高峰值电流模式PCM(peak current mode)控制非理想Buck变换器输出端的启动速度和抗负载冲击能力,提出1种基于可变输出电容的混合补偿方案。该方案在保证环路稳定性和动态响应性能的同时实现了输出电容和环路补偿参数可同步切换。建...为提高峰值电流模式PCM(peak current mode)控制非理想Buck变换器输出端的启动速度和抗负载冲击能力,提出1种基于可变输出电容的混合补偿方案。该方案在保证环路稳定性和动态响应性能的同时实现了输出电容和环路补偿参数可同步切换。建立PCM控制非理想Buck变换器的完整小信号模型,分析系统的开环传递函数受到不同输出电容参数对补偿网络的影响,并进行合理的环路补偿设计。仿真结果表明,补偿后的系统在不同条件变化下,穿越频率和相位裕度都能保持在10 kHz(1/20 fsw)和70°左右。设计输出电容参数和补偿参数同步切换电路,搭建15 W实验样机,实验结果进一步验证了所提方案的可行性。展开更多
基金This work was supported in part by the National Natural Science Foundation of China under Grant 61773006。
文摘The asymmetric dual-three phase BLDC motor has two sets of stator windings,in which the back EMF coefficients are different.This paper takes advantage of the asymmetric dual-three phase BLDC motor’s structural features and proposes a new method for the accelerated problem of the BLDC motor operating in the high speed and the constant electromagnetic power.The dual phase windings of the BLDC motor are integrated into the circuit in the starting stage.When the motor’s back EMF value is equal to the terminal voltage value,switch off a set of RST three phase windingswhose back EMF coefficient is bigger and make the other set of stator windingUVWwith smaller back EMF coefficient continue to operate under the rated power.As the motor rotor speed continues to increase,the electromagnetic torque remains unchanged.By using the peak current control strategy,we can deduce that the phase current of the UVW three-phase winding is twice the RSTthree-phase windingwhen the asymmetric dual-three phase BLDC motor operates at high speed and constant power.
文摘The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases. As a result, the safety operation of the switches is damaged greatly. A novel solution to improve over-current protection with constant peak current limitation is proposed by inducing synchronous slope compensation into the current limit function instead of the original constant voltage. The design principle and method of the protection circuit based on a UC3846 PWM controller for the interleaved dual-forward converter is presented. Experimental results are given to verify the analysis.