The neutral particle analyzer(NPA)is one of the crucial diagnostic devices in a Tokamak facility.The stripping unit is one of the main parts of the NPA.A windowless gas-stripping room with two differential pipes has b...The neutral particle analyzer(NPA)is one of the crucial diagnostic devices in a Tokamak facility.The stripping unit is one of the main parts of the NPA.A windowless gas-stripping room with two differential pipes has been constructed in a parallel electric and magnetic fields(E//B)NPA.The pressure distributions in the stripping chamber are simulated by ANSYS Fluent together with MolFlow+.Based on the pressure distributions obtained from the simulation,the stripping efficiency of the E//B NPA is studied using GEANT4.Hadron reaction physics is modified to track the charge state of each particle in a cross-section-based method in GEANT4.The transmission rates(R)and stripping efficiencies f_(+1)are examined for particle energies ranging from 20 to 200 keV with the input pressure(P_(0)),ranging from 20 to 400 Pa.According to the combined global efficiency,R×f_(+1),P_(0)=240 Pa is obtained as the optimum pressure for the maximum global efficiency in the incident energy range investigated.展开更多
An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of ...An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.展开更多
The pitch angle distributions of ions and electrons can be affected by various processes;thus,they can serve as an important indicator of the physical mechanisms driving the dynamics of space plasmas.From observations...The pitch angle distributions of ions and electrons can be affected by various processes;thus,they can serve as an important indicator of the physical mechanisms driving the dynamics of space plasmas.From observations from the Mars Ion and Neutral Particle Analyzer onboard the Tianwen-1 orbiter,we calculated the pitch angle distributions of protons in the Martian induced magnetosphere by using information from the magnetohydrodynamically simulated magnetic field,and we statistically analyzed the spatial occurrence pattern of different types of pitch angle distributions.Even though no symmetrical features were seen in the dataset,we found the dominance of the field-aligned distribution type over the energy range from 188 to 6232 eV.Maps of the occurrence rate showed the preferential presence of a trapped-like distribution at the lower altitudes of the surveyed nightside region.Although our results are more or less restricted by the adopted magnetic field,they indicate the complexity of the near-Mars proton pitch angle distributions and infer the possibility of wave–particle interactions in the Martian induced magnetosphere.展开更多
Particle density is an important physical property of atmospheric particles. The information on high time-resolution size-resolved particle density is essential for understanding the atmospheric physical and chemical ...Particle density is an important physical property of atmospheric particles. The information on high time-resolution size-resolved particle density is essential for understanding the atmospheric physical and chemical aging processes of aerosols particles. In the present study, a centrifugal particle mass analyzer (CPMA) combined with a differential mobility analyzer (DMA) was deployed to determine the size-resolved effective density of 50 to 350 nm particles at a rural site of Beijing during summer 2016. The measured particle effective densities decreased with increasing particle sizes and ranged from 1.43 to 1.55 g/cm3, on average. The effective particle density distributions were dominated by a mode peaked at around 1.5 g/cm3 for 50 to 350 nm particles. Extra modes with peaks at 1.0, 0.8, and 0.6 g/cm3 for 150, 240, and 350 nm particles, which might be freshly emitted soot particles, were observed during intensive primary emissions episodes. The particle effective densities showed a diurnal variation pattern, with higher values during daytime. A case study showed that the effective density of Aitken mode particles during the new particle formation (NPF) event decreased considerably, indicating the significant contribution of organics to new particle growth.展开更多
It is a great challenge to find effective atomizing technology for reducing industrial pollution; the twin-fluid atomizing nozzle has drawn great attention in this field recently. Current studies on twin-fluid nozzles...It is a great challenge to find effective atomizing technology for reducing industrial pollution; the twin-fluid atomizing nozzle has drawn great attention in this field recently. Current studies on twin-fluid nozzles mainly focus on droplet breakup and single droplet characteristics. Research relating to the influences of structural parameters on the droplet diameter characteristics in the flow field is scarcely available. In this paper, the influence of a self-excited vibrating cavity structure on droplet diameter characteristics was investigated. Twin-fluid atomizing tests were performed by a self-built open atomizing test bench, which was based on a phase Doppler particle analyzer(PDPA). The atomizing flow field of the twin-fluid nozzle with a self-excited vibrating cavity and its absence were tested and analyzed. Then the atomizing flow field of the twin-fluid nozzle with different self-excited vibrating cavity structures was investigated.The experimental results show that the structural parameters of the self-excited vibrating cavity had a great effect on the breakup of large droplets. The Sauter mean diameter(SMD) increased with the increase of orifice diameter or orifice depth. Moreover, a smaller orifice diameter or orifice depth was beneficial to enhancing the turbulence around the outlet of nozzle and decreasing the SMD. The atomizing performance was better when the orifice diameter was2.0 mm or the orifice depth was 1.5 mm. Furthermore, the SMD increased first and then decreased with the increase of the distance between the nozzle outlet and self-excited vibrating cavity, and the SMD of more than half the atomizing flow field was under 35 μm when the distance was 5.0 mm. In addition, with the increase of axial and radial distance from the nozzle outlet, the SMD and arithmetic mean diameter(AMD) tend to increase. The research results provide some design parameters for the twin-fluid nozzle, and the experimental results could serve as a beneficial supplement to the twin-fluid nozzle study.展开更多
Spray atomization of liquid fuel plays an important role in droplet evaporation,combustible mixture formation and subsequent combustion process.Well-atomized liquid spray contributes to high fuel efficiency and low po...Spray atomization of liquid fuel plays an important role in droplet evaporation,combustible mixture formation and subsequent combustion process.Well-atomized liquid spray contributes to high fuel efficiency and low pollutant emissions.Gasoline direct injection(GDI)has been recognized as one of the most effective ways to improve fuel atomization.As a special direct injection method,the air-assisted direct injection utilizes high-speed flow of high-pressure air at the injector exit to assist liquid fuel injection and promote spray atomization at a low injection pressure.This injection method has excellent application potential and advantages for high performance and lightweight engines.In this study,the hollow cone spray emerging from an air-assisted injector was studied in a constant volume chamber with the ambient pressures ranging from 5 kPa to 300 kPa.External macro characteristics of spray were obtained using high speed backlit imaging.Phase Doppler particle analyzer(PDPA)was utilized to study the microcosmic spray characteristics.The results show that under the flash boiling condition,the spray will generate a strong flash boiling point which causes the cone shape spray to expand both inwards and outwards.The axisymmetric inward expansion would converge together and form a lathy aggregation area below the nozzle and the axisymmetric outward expansion greatly increases the spray width.The sauter mean diameter(SMD)of flash boiling condition can be reduced to 5μm compared to the level close to 10μm in the non-flash boiling condition.展开更多
Recently, the demand for REEs (rare earth elements) has been heavily increasing, as they are used in many high-tech products (e.g., because of their specific magnetic behavior). As a result, the supply situation f...Recently, the demand for REEs (rare earth elements) has been heavily increasing, as they are used in many high-tech products (e.g., because of their specific magnetic behavior). As a result, the supply situation for REEs is worsening and the world market is depending on Chinese exports, so that it may be worthwhile to recycle e-waste (electronic waste) in European countries. This article describes an analytical method to analyze REEs in different kinds of e-waste with the help of a simultaneous ICP-OES (ICP optical emission spectrometer). The task is challenging because samples show significant differences in terms of major, minor and trace element concentrations. Depending on the field of application, the level of matrix elements and target elements differs completely, resulting in a wide variety of spectral interferences. The method presented in this article allows an accurate quantification of REEs as well as a high sample throughput. In addition to REEs, other elements of economic interest can be determined in the same way. The development of a sample preparation process is another important issue and considered as well.展开更多
In a gas/particle two-phase test facility, a three-component particle-dynamics anemometer was used to measure the characteristics of gas/particle two-phase flows in a 29 megawatt (MW) pulverized coal industrial boiler...In a gas/particle two-phase test facility, a three-component particle-dynamics anemometer was used to measure the characteristics of gas/particle two-phase flows in a 29 megawatt (MW) pulverized coal industrial boiler equipped with a new type of swirling pulverized coal burner. The distributions of three-dimensional gas/particle velocity, particle volume flux, and particle size distribution were measured under different working conditions. The mean axial velocity and the particle volume flux in the central region of the burner outlet were found to be negative. This indicated that a central recirculation zone was formed in the center of the burner. In the central recirculation zone, the absolute value of the mean axial velocity and the particle volume flux increased when the external secondary air volume increased. The size of the central reflux zone remained stable when the air volume ratio changed. Along the direction of the jet, the peak value formed by the tertiary air gradually moved toward the center of the burner. This tertiary air was mixed with the peak value formed by the air in the adiabatic combustion chamber after the cross-section of x/d = 0.7. Large particles were concentrated near the wall area, and the particle size in the recirculation zone was small.展开更多
基金This work was supported by the National MCF Energy R&D Program of China(No.MOST 2018YFE0310200)the National Natural Science Foundation of China(Nos.11805138 and 11705242)the Fundamental Research Funds For the Central Universities(Nos.YJ201820 and YJ201954)。
文摘The neutral particle analyzer(NPA)is one of the crucial diagnostic devices in a Tokamak facility.The stripping unit is one of the main parts of the NPA.A windowless gas-stripping room with two differential pipes has been constructed in a parallel electric and magnetic fields(E//B)NPA.The pressure distributions in the stripping chamber are simulated by ANSYS Fluent together with MolFlow+.Based on the pressure distributions obtained from the simulation,the stripping efficiency of the E//B NPA is studied using GEANT4.Hadron reaction physics is modified to track the charge state of each particle in a cross-section-based method in GEANT4.The transmission rates(R)and stripping efficiencies f_(+1)are examined for particle energies ranging from 20 to 200 keV with the input pressure(P_(0)),ranging from 20 to 400 Pa.According to the combined global efficiency,R×f_(+1),P_(0)=240 Pa is obtained as the optimum pressure for the maximum global efficiency in the incident energy range investigated.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(No.2018YFE0310200)National Natural Science Foundation of China(Nos.11705242,11805138 and 12175156)the Fundamental Research Funds for the Central Universities in China(Nos.YJ201820 and YJ201954)。
文摘An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.
基金supported by the National Natural Science Foundation of China(Grant No.42241143)the pre-research projects on Civil Aerospace Technologies(No.D020104)funded by the China National Space Administration.
文摘The pitch angle distributions of ions and electrons can be affected by various processes;thus,they can serve as an important indicator of the physical mechanisms driving the dynamics of space plasmas.From observations from the Mars Ion and Neutral Particle Analyzer onboard the Tianwen-1 orbiter,we calculated the pitch angle distributions of protons in the Martian induced magnetosphere by using information from the magnetohydrodynamically simulated magnetic field,and we statistically analyzed the spatial occurrence pattern of different types of pitch angle distributions.Even though no symmetrical features were seen in the dataset,we found the dominance of the field-aligned distribution type over the energy range from 188 to 6232 eV.Maps of the occurrence rate showed the preferential presence of a trapped-like distribution at the lower altitudes of the surveyed nightside region.Although our results are more or less restricted by the adopted magnetic field,they indicate the complexity of the near-Mars proton pitch angle distributions and infer the possibility of wave–particle interactions in the Martian induced magnetosphere.
基金supported by the following projects:the National Key R&D(Research and Development)Program of China(No.2016YFC0202800:Task 1)the National Natural Science Foundation of China(Nos.41475127,41571130021)the framework research program on ‘Photochemical smog in China’ financed by the Swedish Research Council(No.639-2013-6917)
文摘Particle density is an important physical property of atmospheric particles. The information on high time-resolution size-resolved particle density is essential for understanding the atmospheric physical and chemical aging processes of aerosols particles. In the present study, a centrifugal particle mass analyzer (CPMA) combined with a differential mobility analyzer (DMA) was deployed to determine the size-resolved effective density of 50 to 350 nm particles at a rural site of Beijing during summer 2016. The measured particle effective densities decreased with increasing particle sizes and ranged from 1.43 to 1.55 g/cm3, on average. The effective particle density distributions were dominated by a mode peaked at around 1.5 g/cm3 for 50 to 350 nm particles. Extra modes with peaks at 1.0, 0.8, and 0.6 g/cm3 for 150, 240, and 350 nm particles, which might be freshly emitted soot particles, were observed during intensive primary emissions episodes. The particle effective densities showed a diurnal variation pattern, with higher values during daytime. A case study showed that the effective density of Aitken mode particles during the new particle formation (NPF) event decreased considerably, indicating the significant contribution of organics to new particle growth.
基金Supported by National Natural Science Foundation of China(Grant No.51705445)Hebei Provincial Natural Science Foundation of China,(Grant No.E2016203324)Open Foundation of the State Key Laboratory of Fluid Power and Mechatronic Systems of China(Grant No.GZKF-201714)
文摘It is a great challenge to find effective atomizing technology for reducing industrial pollution; the twin-fluid atomizing nozzle has drawn great attention in this field recently. Current studies on twin-fluid nozzles mainly focus on droplet breakup and single droplet characteristics. Research relating to the influences of structural parameters on the droplet diameter characteristics in the flow field is scarcely available. In this paper, the influence of a self-excited vibrating cavity structure on droplet diameter characteristics was investigated. Twin-fluid atomizing tests were performed by a self-built open atomizing test bench, which was based on a phase Doppler particle analyzer(PDPA). The atomizing flow field of the twin-fluid nozzle with a self-excited vibrating cavity and its absence were tested and analyzed. Then the atomizing flow field of the twin-fluid nozzle with different self-excited vibrating cavity structures was investigated.The experimental results show that the structural parameters of the self-excited vibrating cavity had a great effect on the breakup of large droplets. The Sauter mean diameter(SMD) increased with the increase of orifice diameter or orifice depth. Moreover, a smaller orifice diameter or orifice depth was beneficial to enhancing the turbulence around the outlet of nozzle and decreasing the SMD. The atomizing performance was better when the orifice diameter was2.0 mm or the orifice depth was 1.5 mm. Furthermore, the SMD increased first and then decreased with the increase of the distance between the nozzle outlet and self-excited vibrating cavity, and the SMD of more than half the atomizing flow field was under 35 μm when the distance was 5.0 mm. In addition, with the increase of axial and radial distance from the nozzle outlet, the SMD and arithmetic mean diameter(AMD) tend to increase. The research results provide some design parameters for the twin-fluid nozzle, and the experimental results could serve as a beneficial supplement to the twin-fluid nozzle study.
基金Supported by Beijing Institute of Technology Research Fund Program for Young Scholars(2019CX04-031)Foundation Research Funds of Ministry of Industry and Information Technology(JCKY2019602D018)。
文摘Spray atomization of liquid fuel plays an important role in droplet evaporation,combustible mixture formation and subsequent combustion process.Well-atomized liquid spray contributes to high fuel efficiency and low pollutant emissions.Gasoline direct injection(GDI)has been recognized as one of the most effective ways to improve fuel atomization.As a special direct injection method,the air-assisted direct injection utilizes high-speed flow of high-pressure air at the injector exit to assist liquid fuel injection and promote spray atomization at a low injection pressure.This injection method has excellent application potential and advantages for high performance and lightweight engines.In this study,the hollow cone spray emerging from an air-assisted injector was studied in a constant volume chamber with the ambient pressures ranging from 5 kPa to 300 kPa.External macro characteristics of spray were obtained using high speed backlit imaging.Phase Doppler particle analyzer(PDPA)was utilized to study the microcosmic spray characteristics.The results show that under the flash boiling condition,the spray will generate a strong flash boiling point which causes the cone shape spray to expand both inwards and outwards.The axisymmetric inward expansion would converge together and form a lathy aggregation area below the nozzle and the axisymmetric outward expansion greatly increases the spray width.The sauter mean diameter(SMD)of flash boiling condition can be reduced to 5μm compared to the level close to 10μm in the non-flash boiling condition.
文摘Recently, the demand for REEs (rare earth elements) has been heavily increasing, as they are used in many high-tech products (e.g., because of their specific magnetic behavior). As a result, the supply situation for REEs is worsening and the world market is depending on Chinese exports, so that it may be worthwhile to recycle e-waste (electronic waste) in European countries. This article describes an analytical method to analyze REEs in different kinds of e-waste with the help of a simultaneous ICP-OES (ICP optical emission spectrometer). The task is challenging because samples show significant differences in terms of major, minor and trace element concentrations. Depending on the field of application, the level of matrix elements and target elements differs completely, resulting in a wide variety of spectral interferences. The method presented in this article allows an accurate quantification of REEs as well as a high sample throughput. In addition to REEs, other elements of economic interest can be determined in the same way. The development of a sample preparation process is another important issue and considered as well.
基金This work was supported by National Key Research and Development Program of China(Grant No.2017YF C0212500).
文摘In a gas/particle two-phase test facility, a three-component particle-dynamics anemometer was used to measure the characteristics of gas/particle two-phase flows in a 29 megawatt (MW) pulverized coal industrial boiler equipped with a new type of swirling pulverized coal burner. The distributions of three-dimensional gas/particle velocity, particle volume flux, and particle size distribution were measured under different working conditions. The mean axial velocity and the particle volume flux in the central region of the burner outlet were found to be negative. This indicated that a central recirculation zone was formed in the center of the burner. In the central recirculation zone, the absolute value of the mean axial velocity and the particle volume flux increased when the external secondary air volume increased. The size of the central reflux zone remained stable when the air volume ratio changed. Along the direction of the jet, the peak value formed by the tertiary air gradually moved toward the center of the burner. This tertiary air was mixed with the peak value formed by the air in the adiabatic combustion chamber after the cross-section of x/d = 0.7. Large particles were concentrated near the wall area, and the particle size in the recirculation zone was small.