期刊文献+
共找到5,502篇文章
< 1 2 250 >
每页显示 20 50 100
Phase sensitivity of a lossy truncated SU(1,1)interferometer with double-port homodyne detection
1
作者 Yu-Wei Xiao Yue Ji +2 位作者 Jia-Yi Wei Jian-Dong Zhang Li-Li Hou 《Chinese Physics B》 2026年第1期467-472,共6页
We theoretically investigate the phase sensitivity of a truncated SU(1,1)interferometer fed with a two-mode coherent state and employing double-port homodyne detection.On the one hand,we analytically demonstrate that ... We theoretically investigate the phase sensitivity of a truncated SU(1,1)interferometer fed with a two-mode coherent state and employing double-port homodyne detection.On the one hand,we analytically demonstrate that the two-mode coherent state provides better phase sensitivity than the single-mode coherent state.In addition,we show that the doubleport homodyne detection is a quasi-optimal measurement.For a bright coherent-state input,the sensitivity of this scheme saturates the phase-sensitivity bound determined by the quantum Fisher information.On the other hand,we quantitatively illustrate the advantage of double-port homodyne detection over the single-port scheme under ideal conditions and in the presence of photon loss,respectively.Furthermore,our analysis indicates that the scheme we propose is robust against photon loss. 展开更多
关键词 quantum-enhanced interferometer parameter estimation homodyne detection
原文传递
Direct position determination based on rotating single-baseline interferometer for multiple time-frequency aliased sources
2
作者 Yuan ZHANG Guizhou WU +2 位作者 Fucheng GUO Zihan YAO Min ZHANG 《Chinese Journal of Aeronautics》 2026年第2期389-401,共13页
Rotating Single-Baseline Interferometer(RSBI)systems have attracted considerable attention for Direct Position Determination(DPD)due to their simplicity and high localization accuracy.Nevertheless,the growing complexi... Rotating Single-Baseline Interferometer(RSBI)systems have attracted considerable attention for Direct Position Determination(DPD)due to their simplicity and high localization accuracy.Nevertheless,the growing complexity of electromagnetic environments has led to scenarios with multiple time-frequency aliased sources,rendering conventional DPD methods for RSBI systems ineffective.Previous studies have predominantly concentrated on deploying antenna arrays and applying related signal-processing techniques for localization.Typically,these approaches necessitate that the number of physical antennas exceeds the number of sources.For RSBI systems already in practical operation,this would entail the installation of additional physical antennas,which implies equipment recycling and hardware upgrades.In numerous cases,such modifications are unfeasible.This paper proposes a novel Relative Offset-based Direct Position Determination(RO-DPD)method for RSBI systems that can handle multiple time-frequency aliased sources.The proposed method overcomes the challenge of simultaneous positioning without requiring hardware modifications by leveraging time accumulation and algorithmic enhancements.The implementation of the method involves three key steps.Firstly,the rotation of the interferometer is synthesized into a virtual Uniform Circular Array(UCA).Secondly,a novel estimation variable,termed relative offset,is introduced.The variable serves as an intermediate parameter to establish correlation equations between the positions of multiple time-frequency aliased sources and the intercepted signals.Thirdly,the relative offset model in the UCA is transformed into a virtual Uniform Linear Array(ULA)model,from which the cost function can be derived via the Spatial Smoothing(SS)MUSIC algorithm.Theoretical analysis and simulation results verify the effectiveness of the proposed method.Compared with traditional approaches,the RO-DPD method maintains the low complexity of RSBI systems while demonstrating robust performance in complex electromagnetic environments. 展开更多
关键词 Rotating single-baseline interferometer Direct position determination Uniform circular array Array processing
原文传递
Multiparameter hierarchical sensitivity analysis of tilt-to-length coupling noise in Taiji science interferometer
3
作者 Fei Xie Xiaodong Peng +2 位作者 Wenlin Tang Mengyuan Zhao Xiaoshan Ma 《Chinese Physics B》 2026年第1期399-408,共10页
Tilt-to-length(TTL)coupling noise is a critical issue in space-based gravitational wave detection due to its complex dependence on multiple interacting factors,which complicates the identification of dominant paramete... Tilt-to-length(TTL)coupling noise is a critical issue in space-based gravitational wave detection due to its complex dependence on multiple interacting factors,which complicates the identification of dominant parameters.To address this challenge,we develop a simulation model of the Taiji scientific interferometer,generating noise datasets under multiparameter conditions.Given the uniqueness of the telescope as well as the convergence behavior of the algorithm,the analysis is structured hierarchically:(i)the telescope level and(ii)the optical bench level.A hierarchical framework combining XGBoost and SHapley Additive exPlanations(SHAP)values is employed to model the intricate relationships between parameters and TTL coupling noise,supplemented by sensitivity analysis.Our results identify pointing jitter and telescope radius as the dominant parameters at the telescope level,while the angles of the plane mirrors and beam splitters are most influential at the optical bench level.The parameter space is reduced from 86 dimensions to 14 dimensions without sacrificing model accuracy.This approach offers actionable insights for optimizing the Taiji interferometer design. 展开更多
关键词 space-based gravitational wave detection intrasatellite science interferometer tilt-to-length coupling noise sensitivity analysis
原文传递
A near-infrared all-fiber mode monitor based on the mini-two-path Mach-Zehnder interferometer
4
作者 ZHU Xiao-Jun LIU Yu +5 位作者 WU Yue ZHUANG Hao-Ran SUN Dan SHI Yue-Chun CAO Juan YANG Yong-Jie 《红外与毫米波学报》 北大核心 2025年第3期352-357,共6页
A novel near-infrared all-fiber mode monitor based on a mini-two-path Mach-Zehnder interferometer(MTP-MZI)is proposed.The MTP-MZI mode monitor is created by fusing a section of(no-core fiber,NCF)and a(single-mode fibe... A novel near-infrared all-fiber mode monitor based on a mini-two-path Mach-Zehnder interferometer(MTP-MZI)is proposed.The MTP-MZI mode monitor is created by fusing a section of(no-core fiber,NCF)and a(single-mode fiber,SMF)together with an optical fiber fusion splicer,establishing two distinct centimeter-level optical transmission paths.Since the high-order modes in NCF transmit near-infrared light more sensitively to curvature-induced energy leakage than the fundamental mode in SMF,the near-infrared high-order mode light leaks out of NCF when the curvature changes,causing the MTP-MZI transmission spectrum to change.By ana⁃lyzing the relationship between the curvature,transmission spectrum,and spatial frequency spectrum,the modes involved in the interference can be studied,thereby revealing the mode transmission characteristics of near-infra⁃red light in optical fibers.In the verification experiments,higher-order modes were excited by inserting a novel hollow-core fiber(HCF)into the MTP-MZI.When the curvature of the MTP-MZI changes,the near-infrared light high-order mode introduced into the device leaks out,causing the transmission spectrum to return to its origi⁃nal state before bending and before the HCF was spliced.The experimental results demonstrate that the MTP-MZI mode monitor can monitor the fiber modes introduced from the external environment,providing both theoretical and experimental foundations for near-infrared all-fiber mode monitoring in optical information systems. 展开更多
关键词 near-infrared mode monitor Mach-Zehnder interferometer two-path structure all-fiber-format
在线阅读 下载PDF
Direction finding for wideband signal and multi-target with interferometer
5
作者 PENG Bo SUN Jikang LI Chao 《Journal of Systems Engineering and Electronics》 2025年第5期1132-1139,共8页
According to the measurement principle of the traditional interferometer,a narrowband signal model is established and used,however,for wideband signals or multiple signals,this model is invalid.For the problems of dir... According to the measurement principle of the traditional interferometer,a narrowband signal model is established and used,however,for wideband signals or multiple signals,this model is invalid.For the problems of direction finding with interferometer for wideband signals and multiple signals scene,a frequency domain phase interferometer is proposed and the concrete implementation scheme is given.The proposed method computes the phase difference in frequency domain,and finds multi-target results with judging the spectrum amplitude changing,and uses the frequency phase difference to compute the arrival angle.Theoretical analysis and simulation results show that the proposed method effectively solves the problem of the angle estimation with phase interferometer for wideband signals,and has good performance in multiple signals scene with nonoverlapping spectrum or partially overlapping.In addition,the wider the signal bandwidth,the better direction finding performance of this algorithm. 展开更多
关键词 phase interferometer wideband signal direction finding multi-signal direction finding frequency domain interferometer
在线阅读 下载PDF
Signal estimation bias in x-ray dark-field imaging using dual phase grating interferometer
6
作者 Zhi-Li Wang Zun Zhang +1 位作者 Heng Chen Xin Ge 《Chinese Physics B》 2025年第3期550-558,共9页
In x-ray dark-field imaging using dual phase grating interferometer,multi-contrast signals are extracted from a set of acquired phase-stepping data by using the least-squares fitting algorithm.The extracted mean inten... In x-ray dark-field imaging using dual phase grating interferometer,multi-contrast signals are extracted from a set of acquired phase-stepping data by using the least-squares fitting algorithm.The extracted mean intensity,amplitude and visibility signals may be intrinsically biased.However,it is still unclear how large these biases are and how the data acquisition parameters influence the biases in the extracted signals.This work set out to address these questions.Analytical expressions of the biases of the extracted signals were theoretically derived by using a second-order Taylor series expansion.Extensive numerical simulations were performed to validate the theoretical results.It is illustrated that while the estimated mean intensity signal is always unbiased,the estimated amplitude and visibility signals are both positively biased.While the biases of the estimated amplitude signals are proportional to the inverse of the total number of phase steps,the biases of the estimated visibility signals are inversely proportional to the product of the total number of phase steps and the mean number of photons counted per phase step.Meanwhile,it is demonstrated that the dependence of the biases on the mean visibility is quite different from that of Talbot-Lau interferometer due to the difference in the intensity model.We expect that these results can be useful for data acquisition optimizations and interpretation of x-ray dark-field images. 展开更多
关键词 x-ray imaging dual phase grating interferometer dark-field imaging signal bias
原文传递
Temporal SU(1,1) Interferometer Based on Four- Wave Mixing Time Lens and Its Applications in Ultrafast Time-Frequency Manipulation
7
作者 Tianyu Liu Zepeng Liu 《Journal of Electronic Research and Application》 2025年第4期327-336,共10页
Temporal optics,which enables lossless manipulation of ultrafast pulses,offers a new dimension for the regulation of quantum optical fields.In this paper,we established a temporal Fourier transform(TF)system based on ... Temporal optics,which enables lossless manipulation of ultrafast pulses,offers a new dimension for the regulation of quantum optical fields.In this paper,we established a temporal Fourier transform(TF)system based on a four-wave mixing(FWM)time lens and constructed a full quantum theoretical model for the resulting temporal SU(1,1)interferometer.This interferometer has high temporal resolution,can impose interference in both time and frequency domains,and is sensitive to the phase derivative.By introducing linear time-varying phase modulation,we achieved sub-picosecond precision in temporal autocorrelation measurements and generatedan optical frequency comb with a fixed interval based on a feedback iteration mechanism.Theoretical analysis revealsthe crucial regulatory role of time-frequency coupling in quantum interference,providing novel solutions for ultrafast quantum imaging,temporal mode encoding,and the generation of optical frequency quantization. 展开更多
关键词 Temporal SU(1 1)interferometer Four-wave mixing time lens Optical frequency comb Temporal optics
在线阅读 下载PDF
Space-Borne Interferometers to Detect Thousands of Memory Signals Emitted by Stellar-Mass Binary Black Holes
8
作者 Shaoqi Hou Zhi-Chao Zhao +1 位作者 Zhoujian Cao Zong-Hong Zhu 《Chinese Physics Letters》 2025年第10期323-330,共8页
The gravitational memory effect manifests gravitational nonlinearity,degenerate vacua,and asymptotic symmetries;its detection is considered challenging.We propose using a space-borne interferometer to detect memory si... The gravitational memory effect manifests gravitational nonlinearity,degenerate vacua,and asymptotic symmetries;its detection is considered challenging.We propose using a space-borne interferometer to detect memory signals from stellar-mass binary black holes(BBHs),typically targeted by ground-based detectors.We use DECIGO detector as an example.Over 5 years,DECIGO is estimated to detect approximately 2,036 memory signals(SNRs>3)from stellar-mass BBHs.Simulations used frequency-domain memory waveforms for direct SNR estimation.Predictions utilized a GWTC-3 constrained BBH population model(Power law+Peak mass,DEFAULT spin,Madau-Dickinson merger rate).The analysis used conservative lower merger rate limits and considered orbital eccentricity.The high detection rate stems from strong memory signals within DECIGO’s bandwidth and the abundance of stellar-mass BBHs.This substantial and conservative detection count enables statistical use of the memory effect for fundamental physics and astrophysics.DECIGO exemplifies that space interferometers may better detect memory signals from smaller mass binaries than their typical targets.Detectors in lower frequency bands are expected to find strong memory signals from∼10^(4)M⊙binaries. 展开更多
关键词 space borne interferometer detect memory signals gravitational memory effect decigo detector binary black holes bbhs typically stellar mass binary black holes signal noise ratio
原文传递
Research on a compact and high sensitivity gas pressure sensor based on fiber Fabry-Pérot interferometer and Bragg grating
9
作者 LIU Qinpeng XING Meihua +2 位作者 YANG Di LIU Bo YAN Cheng 《Optoelectronics Letters》 2025年第6期321-327,共7页
A compact and highly sensitive gas pressure and temperature sensor based on Fabry-Pérot interferometer(FPI)and fiber Bragg grating(FBG)is proposed and demonstrated experimentally in this paper.The theoretical mod... A compact and highly sensitive gas pressure and temperature sensor based on Fabry-Pérot interferometer(FPI)and fiber Bragg grating(FBG)is proposed and demonstrated experimentally in this paper.The theoretical model for pressure and temperature sensing is established.Building on this foundation,a novel micro silicon cavity sensor structure sensitive to pressure is devised downstream of an FBG.The concept of separate measurement and the mechanisms enhancing pressure sensitivity are meticulously analyzed,and the corresponding samples are fabricated.The experimental results indicate that the pressure sensitivity of the sensor is-747.849 nm/MPa in 0—100 k Pa and its linearity is 99.7%and it maintains good stability in 150 min.The sensor offers the advantages of compact size,robust construction,easy fabrication,and high sensitivity,making it potentially valuable for micro-pressure application. 展开更多
关键词 fiber bragg grating fbg gas pressure sensor temperature sensor separate measurement fiber Bragg grating fiber Fabry P rot interferometer theoretical model pressure temperature sensing micro silicon cavity sensor structure
原文传递
Integrating optical and radiofrequency interferometry for enhanced phase sensing
10
作者 Ruimin Jie Zhaopeng Zhang +1 位作者 Chen Zhu Jie Huang 《Advanced Photonics Nexus》 2026年第1期111-121,共11页
Interferometry is a crucial investigative technique used across diverse fields to achieve highprecision measurements.It works by analyzing the phase difference between two interfering waves,which results from variatio... Interferometry is a crucial investigative technique used across diverse fields to achieve highprecision measurements.It works by analyzing the phase difference between two interfering waves,which results from variations in optical path lengths within an interferometer.We introduce a novel method for directly measuring changes in the phase difference within an optical interferometer,importantly,with the added advantage of a controllable enhancement factor.This approach is achieved through a two-step process:first,the optical phase difference is encoded into a sub-GHz radiofrequency(RF)signal using microwave-photonic manipulation;then,RF interferometry-assisted phase amplification is implemented at the destructive interference point.In our experiments,we demonstrate a phase sensitivity of 2.14 rad∕nm operating at 140 MHz using a miniature in-fiber Fabry-Pérot interferometer for sub-nanometer displacement sensing,which reveals a sensitivity magnification factor of 258.6.With further refinement,we anticipate that even higher enhancement factors can be achieved,paving the way for the development of cost-effective,ultrasensitive interferometry-based instruments for high-precision optical measurements. 展开更多
关键词 fiber-optic interferometer microwave photonics interferometRY phase sensing radiofrequency interferometry
在线阅读 下载PDF
MATHEMATICAL MODEL OF ~4He QUANTUM INTERFEROMETER GYROSCOPE 被引量:5
11
作者 郑睿 赵伟 +2 位作者 刘建业 谢征 冯铭瑜 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2012年第4期360-366,共7页
The mathematical model of 4He quantum interferometer gyroscope is presented. The model includes the driven equation, the current equation and the position equation. Therefore, it can sufficiently describe the gyro- sc... The mathematical model of 4He quantum interferometer gyroscope is presented. The model includes the driven equation, the current equation and the position equation. Therefore, it can sufficiently describe the gyro- scope system. The driven equation shows the thermally driven gyroscope can work for a long time but the pres- sure driven one cannot. From the current equation, the superfluid currents passing through the weak link contain the AC currents which show the rotation flux, and other currents caused by drive. As shown in the position equa- tion, the displacement of diaphragm is the only detectable parameter in the gyroscope system. The model is tested by the simulations based on experimental parameters, and can be used to research performance of the gyroscope and analyse the gyroscope error. 展开更多
关键词 4He quantum interferometer gyroscope mathematical model pressure drive thermal drive
在线阅读 下载PDF
Fourier Spectrometer based on Wide-range and Phase-locked Michelson Interferometer with Femtosecond Laser Excitation
12
作者 王自鑫 谢向生 +1 位作者 邓俊祺 周建英 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第1期1-4,I0001,共5页
A wide-range and phase-locked Michelson interferometer technique is described. This technique combined with femtosecond laser is used to measure the spectrum of the rare-earth ion Nd:YVO4, which presents very high si... A wide-range and phase-locked Michelson interferometer technique is described. This technique combined with femtosecond laser is used to measure the spectrum of the rare-earth ion Nd:YVO4, which presents very high signal to noise ratio of interferometric intensity output and higher spectral resolution than traditional grating spectrophotometer. 展开更多
关键词 Wide-ranged and phase-locked Michelson interferometer Fourier spectrometer Femtosecond laser High signal to noise ratio High resolution
在线阅读 下载PDF
Electro-Optical Effect Measurement of Thin-Film Material Using PM Fiber Mach-Zehnder Interferometer 被引量:1
13
作者 屠晓光 赵雷 +4 位作者 陈平 陈少武 左玉华 余金中 王启明 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2007年第7期1012-1016,共5页
A polarization-maintaining (PM) fiber Mach-Zehnder (MZ) interferometer has been established to measure the EO effect of very thin film materials with optical anisotropy. Unlike a common MZ interferometer, all the ... A polarization-maintaining (PM) fiber Mach-Zehnder (MZ) interferometer has been established to measure the EO effect of very thin film materials with optical anisotropy. Unlike a common MZ interferometer, all the components are connected via polarization-maintaining fibers. At the same time, a polarized DFB laser with a maximum power output of 10mW is adopted as the light source to induce a large extinction ratio. Here,we take it to determine the electro-optical coefficients of a very thin superlattice structure with GaAs, KTP, and GaN as comparative samples. The measured EO coefficients show good comparability with the others. 展开更多
关键词 electro-optic effect polarization-maintaining fiber Mach-Zehnder interferometer
在线阅读 下载PDF
Elementary analysis of interferometers for wave particle duality test and the prospect of going beyond the complementarity principle 被引量:5
14
作者 李志远 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期202-214,共13页
A distinct method to show a quantum object behaving both as wave and as particle is proposed and described in some detail. We make a systematic analysis using the elementary methodology of quantum mechanics upon Young... A distinct method to show a quantum object behaving both as wave and as particle is proposed and described in some detail. We make a systematic analysis using the elementary methodology of quantum mechanics upon Young's two-slit interferometer and the Mach-Zehnder two-arm interferometer with the focus placed on how to measure the interference pattern (wave nature) and the which-way information (particle nature) of quantum objects. We design several schemes to simultaneously acquire the which-way information for an individual quantum object and the high-contrast interference pattern for an ensemble of these quantum objects by placing two sets of measurement instruments that are well separated in space and whose perturbation of each other is negligibly small within the interferometer at the same time. Yet, improper arrangement and cooperation of these two sets of measurement instruments in the interferometer would lead to failure of simultaneous observation of wave and particle behaviors. The internal freedoms of quantum objects could be harnessed to probe both the which-way information and the interference pattern for the center-of-mass motion. That quantum objects can behave beyond the wave-particle duality and the complementarity principle would stimulate new conceptual examination and exploration of quantum theory at a deeper level. 展开更多
关键词 wave-particle duality complementarity principle atom interferometer
原文传递
Simulation of distributed optical fiber disturbance detection system based on Sagnac/Mach-Zehnder interferometer and cross-correlation location 被引量:2
15
作者 方捻 李杰 +2 位作者 王陆唐 黄肇明 杨烨 《Journal of Shanghai University(English Edition)》 CAS 2011年第2期115-118,共4页
A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filte... A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations. 展开更多
关键词 Sagnac interferometer Mach-Zehnder interferometer distributed optical fiber disturbance detection system cross-correlation LOCATION
在线阅读 下载PDF
Experimental research on the feature of an x-ray Talbot–Lau interferometer versus tube accelerating voltage 被引量:3
16
作者 王圣浩 Margie P.Olbinado +7 位作者 Atsushi Momose 韩华杰 胡仁芳 王志立 高昆 张凯 朱佩平 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期673-678,共6页
X-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a con- ventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of sample... X-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a con- ventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of samples producing low absorption contrast, thus beating tremendous potential for future clinical diagnosis. In this work, by changing the accel- erating voltage of the x-ray tube from 35 kV to 45 kV, x-ray phase-contrast imaging of a test sample is performed at each integer value of the accelerating voltage to investigate the characteristic of an x-ray Talbot-Lau interferometer (located in the Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) versus tube voltage. Ex- perimental results and data analysis show that within a range this x-ray Talbot-Lau interferometer is not sensitive to the accelerating voltage of the tube with a constant fringe visibility of ~ 44%. This x-ray Talbot-Lau interferometer research demonstrates the feasibility of a new dual energy phase-contrast x-ray imaging strategy and the possibility to collect a refraction spectrum. 展开更多
关键词 x-ray Talbot-Lau interferometer x-ray imaging PHASE-CONTRAST tube accelerating voltage x-ray tube
原文传递
Ultrasonic sensitivity-improved fiber-optic Fabry-Perot interferometer using a beam collimator and its application for ultrasonic imaging of seismic physical models 被引量:3
17
作者 Zhi-Hua Shao Xue-Guang Qiao +1 位作者 Feng-Yi Chen and Qiang-Zhou Rongt 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第9期128-136,共9页
An ultrasonic sensitivity-improved fiber-optic Fabry-Perot interferometer (FPI) is proposed and employed for ultra- sonic imaging of seismic physical models (SPMs). The FPI comprises a flexible ultra-thin gold fil... An ultrasonic sensitivity-improved fiber-optic Fabry-Perot interferometer (FPI) is proposed and employed for ultra- sonic imaging of seismic physical models (SPMs). The FPI comprises a flexible ultra-thin gold film and the end face of a graded-index multimode fiber (MMF), both of which are enclosed in a ceramic tube. The MMF in a specified length can collimate the diverged light beam and compensate for the light loss inside the air cavity, leading to an increased spectral fringe visibility and thus a steeper spectral slope. By using the spectral sideband filtering technique, the collimated FP1 shows an improved ultrasonic response. Moreover, two-dimensional images of two SPMs are achieved in air by recon- structing the pulse-echo signals through using the time-of-flight approach. The proposed sensor with easy fabrication and compact size can be a good candidate for high-sensitivity and high-precision nondestructive testing of SPMs. 展开更多
关键词 fiber-optic sensor Fabry-Perot interferometer seismic physical model
原文传递
ANALYSIS OF LOCATION ACCURACY FOR AN EMITTER USING SATELLITE-MOUNTED INTERFEROMETER 被引量:3
18
作者 周一宇 郭志刚 +1 位作者 陆伟宁 朱伟强 《Chinese Journal of Aeronautics》 SCIE EI CSCD 1998年第1期30-37,共8页
ANALYSISOFLOCATIONACCURACYFORANEMITTERUSINGSATELLITE┐MOUNTEDINTERFEROMETERZhouYiyu(周一宇),GuoZhigang(郭志刚)(Nati... ANALYSISOFLOCATIONACCURACYFORANEMITTERUSINGSATELLITE┐MOUNTEDINTERFEROMETERZhouYiyu(周一宇),GuoZhigang(郭志刚)(NationalUniversityofD... 展开更多
关键词 satellite attitude control positioning devices phase switching interferometers error ananlysis passive location
在线阅读 下载PDF
Recent Progress of the HL-2A Laser Interferometer 被引量:2
19
作者 周艳 邓中朝 +7 位作者 易江 李永高 李连才 郑玲 赵开君 杨青巍 丁玄同 段旭如 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期413-416,共4页
A new multi-channel far infrared (FIR) laser interferometer was built up and ap- plied to HL-2A. The unique feature of real-time heterodyne interferometer is the combination of high power radiation source (300 mW)... A new multi-channel far infrared (FIR) laser interferometer was built up and ap- plied to HL-2A. The unique feature of real-time heterodyne interferometer is the combination of high power radiation source (300 mW), lower noise room temperature detector (noise tempera- ture below 6000 K) with good spatial resolution of 7 cm. Various parameters are optimized for maximum laser output power. Zero crossings of the signals are counted with field programmable gate array (FPGA) digital circuitry yielding the resolution of 1/1000 fringe. The newly measured results including density fluctuation are also presented. 展开更多
关键词 FIR laser interferometer MEASUREMENT density fluctuation
在线阅读 下载PDF
Using a Mach–Zehnder interferometer to deduce nitrogen density mapping 被引量:2
20
作者 F.Boudaoud M.Lemerini 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期336-340,共5页
This work presents an optical method using the Mach–Zehnder interferometer. We especially diagnose a pure nitrogen gas subjected to a point to plane corona discharge, and visualize the density spatial map. The intere... This work presents an optical method using the Mach–Zehnder interferometer. We especially diagnose a pure nitrogen gas subjected to a point to plane corona discharge, and visualize the density spatial map. The interelectrode distance equals6 mm and the variation of the optical path has been measured at different pressures: 220 Torr, 400 Torr, and 760 Torr.The interferograms are recorded with a CCD camera, and the numerical analysis of these interferograms is assured by the inverse Abel transformation. The nitrogen density is extracted through the Gladstone–Dale relation. The obtained results are in close agreement with values available in the literature. 展开更多
关键词 Mach–Zehnder interferometer Gladstone–Dale equation Abel inversion corona discharge
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部