A simulation model of shipboard low voltage molded case circuit breaker (MCCB) is developed based on power system simulation software PSCAD/EMTDC. The motion characteristic of the magnetic instantaneous acting trip ba...A simulation model of shipboard low voltage molded case circuit breaker (MCCB) is developed based on power system simulation software PSCAD/EMTDC. The motion characteristic of the magnetic instantaneous acting trip based on electromagnetic characteristic analysis and Cassie arc model are applied into the simulation model to describe the dynamic behavior of the MCCB during short-circuit protection. The results of short-circuit interruption experiments verify the simulation model. It demonstrates that the simulation model has good prospect in optimizing the design and protection performance of MCCB.展开更多
In order to analyze the performances of directly-driven permanent magnet synchronous generator wind turbine (PMSG) connecting to the grid, photovoltaic array and microtubine, dynamic models of them are established. Th...In order to analyze the performances of directly-driven permanent magnet synchronous generator wind turbine (PMSG) connecting to the grid, photovoltaic array and microtubine, dynamic models of them are established. The validity of the established models and proposed control strategies are demonstrated by simulation system under the software package PSCAD/EMTDC.展开更多
More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in o...More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.展开更多
文摘A simulation model of shipboard low voltage molded case circuit breaker (MCCB) is developed based on power system simulation software PSCAD/EMTDC. The motion characteristic of the magnetic instantaneous acting trip based on electromagnetic characteristic analysis and Cassie arc model are applied into the simulation model to describe the dynamic behavior of the MCCB during short-circuit protection. The results of short-circuit interruption experiments verify the simulation model. It demonstrates that the simulation model has good prospect in optimizing the design and protection performance of MCCB.
文摘In order to analyze the performances of directly-driven permanent magnet synchronous generator wind turbine (PMSG) connecting to the grid, photovoltaic array and microtubine, dynamic models of them are established. The validity of the established models and proposed control strategies are demonstrated by simulation system under the software package PSCAD/EMTDC.
文摘More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.