With the deepened transformation of China's power system, the stability and reliability of power utilization have been dramatically improved, but meter reading data acquisition does not keep pace with the times. With...With the deepened transformation of China's power system, the stability and reliability of power utilization have been dramatically improved, but meter reading data acquisition does not keep pace with the times. With the continuous maturity of low-voltage power line communication (PLC), this leads us to see hopes of using PLC technology to realize remote meter reading. In this paper, based on current PLC technology and combining domestic and foreign successful cases, a beneficial exploration and research is conducted from the composition and establishment of software and the design of software and protocol.展开更多
Since the Modbus RTU wired communication protocol of Siemens variable frequency motors is unstable and lacks a protection mechanism, there is a risk of user information leakage. Aiming at the problems of insufficient ...Since the Modbus RTU wired communication protocol of Siemens variable frequency motors is unstable and lacks a protection mechanism, there is a risk of user information leakage. Aiming at the problems of insufficient flexibility of traditional defense methods and poor defense effects, The present work proposed a new dual detection method based on MODBUS RTU, which combines the dual monitoring mechanism of “Address Resolution Protocol (ARP) request detection” and “ARP response detection”. In order to improve detection efficiency, two real-time updated linear tables are introduced, which can effectively deal with the three ARP spoofing methods of updating the ARP buffer. Based on the analysis of the hidden dangers of the Modbus RTU wired communication protocol, a wired connection between the S7-1200 PLC and the variable frequency motor was established, and a real experimental platform was constructed to demonstrate the attack. The intensity of ARP attacks has gradually increased over time. Through comparative experiments with traditional defense methods, it is proved that the algorithm enhances the protocol mechanism in principle, and is more flexible and reliable than traditional methods.展开更多
文摘With the deepened transformation of China's power system, the stability and reliability of power utilization have been dramatically improved, but meter reading data acquisition does not keep pace with the times. With the continuous maturity of low-voltage power line communication (PLC), this leads us to see hopes of using PLC technology to realize remote meter reading. In this paper, based on current PLC technology and combining domestic and foreign successful cases, a beneficial exploration and research is conducted from the composition and establishment of software and the design of software and protocol.
文摘Since the Modbus RTU wired communication protocol of Siemens variable frequency motors is unstable and lacks a protection mechanism, there is a risk of user information leakage. Aiming at the problems of insufficient flexibility of traditional defense methods and poor defense effects, The present work proposed a new dual detection method based on MODBUS RTU, which combines the dual monitoring mechanism of “Address Resolution Protocol (ARP) request detection” and “ARP response detection”. In order to improve detection efficiency, two real-time updated linear tables are introduced, which can effectively deal with the three ARP spoofing methods of updating the ARP buffer. Based on the analysis of the hidden dangers of the Modbus RTU wired communication protocol, a wired connection between the S7-1200 PLC and the variable frequency motor was established, and a real experimental platform was constructed to demonstrate the attack. The intensity of ARP attacks has gradually increased over time. Through comparative experiments with traditional defense methods, it is proved that the algorithm enhances the protocol mechanism in principle, and is more flexible and reliable than traditional methods.