The service provided by the GC(Gamma Cameras)in the Nuclear Medicine departments fails because of their breakdown,generally due to the associated electronics and not to the physical detection components.For this reaso...The service provided by the GC(Gamma Cameras)in the Nuclear Medicine departments fails because of their breakdown,generally due to the associated electronics and not to the physical detection components.For this reason,it was decided to develop an electronic system that allows the recovery and optimization of disused GC,starting with the design of the preamplifier for a PMT(photomultiplier tube).The circuit was designed and simulated and the list of components necessary for the construction of the preamplifier was generated,as well as the printed circuit board was designed for its assembly.By simulating the preamplifier this worked in linear mode.This determines that the amplitude of the output signal is proportional to the amount of charge delivered by the detector.This card allows an automatic adjustment of the signals of the PMT as do the modern GC.展开更多
The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors wi...The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.展开更多
Two-photon fluorescence microscopy(TPFM)is widely used for imaging of biological tissue due to its robustness to scattering,high resolution,and ease of multiplexing fluorescent probes.However,TPFM volumetric imaging r...Two-photon fluorescence microscopy(TPFM)is widely used for imaging of biological tissue due to its robustness to scattering,high resolution,and ease of multiplexing fluorescent probes.However,TPFM volumetric imaging rates are typically low,limiting the ability to image whole cleared tissues and large surgical specimens.While innovations in TPFM technology,such as parallel-scanning,have drastically increased imaging speed,these improvements have typically focused on high frame rate,single field-of-view imaging rather than extending the area/volume imaging rate.In this work,we bridge the gap between high imaging speed and high area and volumetric imaging throughput by combining parallel scanning with tilted-plane strip-scanning using custom silicon photomultiplier(SiPM)tiled-array detectors.We demonstrate 200 MP/s with four spectral channels(800 MSpectra/s)and an effective area imaging speed of up to 52 mm^(2)∕s using four parallel beams.Custom detectors and lens array enable non-descanned imaging with minimal crosstalk combined with light collection efficiency comparable to a conventional single-point scanning TPFM.Finally,the low-cost of the custom detectors(∼$250 per channel)and the scalability of the detection optics allow for ease of spectral multiplexing.展开更多
Self-excited longitudinal combustion instabilities were investigated in a hypergolic liquid bipropellant combustor, which applied single dual-swirl coaxial injector. Hot-fire tests were conducted for four different in...Self-excited longitudinal combustion instabilities were investigated in a hypergolic liquid bipropellant combustor, which applied single dual-swirl coaxial injector. Hot-fire tests were conducted for four different injector geometries, while extensive tests on injection conditions were carried out for each injector geometry. The synchronous measurement of the pressure and heat release rate was applied, successfully capturing the process of the pressure and heat release rate enhanced coupling and developing into in-phase oscillation. By calculating Rayleigh index at the head and middle section of the chamber, it is shown that Rayleigh index of the middle section is even higher than that of the head, indicating a long heat release zone. When the combustion instability occurs, the pressure in propellant manifolds also oscillates with the same frequency and lags behind the oscillation in the combustor. Compared to the oscillation in the outer injector manifold, the oscillation in the inner injector manifold shows a higher correlation with that in the chamber in amplitude and phase. Based on numerical simulations of the multiphase cold flow inside the injector and combustion process in the chamber, it is found that injector geometries affect longitudinal combustion instability by changing spray cone angle. The spray with small cone angle is more sensitive to the modulation of longitudinal pressure wave in combustion simulations, which is more likely to excite the longitudinal combustion instability. Meanwhile, the combustion instability may be related to the pulsating coherent structure generated by the spray fluctuation, which is determined by injection conditions. Besides, a positive feedback closed-loop system associated with the active fluctuation and passive oscillation of the spray is believed to excite and sustain the longitudinal combustion instability.展开更多
Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency...Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency, high position resolution,and large-area splicing, and can well meet the requirement of large area neutron detection for neutron diffractometers. An engineering detector prototype based on a ~6LiF/ZnS(Ag) scintillation screen and SiPM array readout was fabricated for the General Purpose Powder Diffractometer of China Spallation Neutron Source(CSNS). The detector has an active area of 196 mm × 444 mm, with a pixel size of 4 mm × 4 mm. The key performances of the detector prototype were tested at the BL20 neutron beam line of CSNS. The test results show that the neutron detection efficiency of the detector was 32% and 42% at wavelengths of 1.4 ? and 2.8 ?, respectively. An interpolated neutron detection efficiency of 40.2% at a wavelength of 2 ? was obtained. The tested neutron efficiency non-uniformity of the detector was 10.2%, which is less than one-half that of the current general purpose powder diffractometer scintillator neutron detectors at CSNS. This work achieves, for the first time, an efficiency uniformity of < 11% in large-area mosaic neutron detectors, alongside significant advancements in electromagnetic interference immunity and cost-effectiveness.展开更多
Silicon photomultipliers (SiPMs) are a new generation of semiconductor-based photon counting devices with the merits of low weight, low power consumption and low voltage operation, promising to meet the needs of spa...Silicon photomultipliers (SiPMs) are a new generation of semiconductor-based photon counting devices with the merits of low weight, low power consumption and low voltage operation, promising to meet the needs of space particle physics experiments. In this paper, comparative studies of SiPMs and traditional vacuum photomultiplier tubes (PMTs) have been performed regarding the basic properties of dark currents, dark counts and excess noise factors. The intrinsic optical erosstalk effect of SiPMs was evaluated.展开更多
To maximize signal collection in nonlinear optical microscopy,non-descanned epi-detection is generally adopted for in vivo imaging.However,because of severe scattering in biological samples,most of the emitted fluores...To maximize signal collection in nonlinear optical microscopy,non-descanned epi-detection is generally adopted for in vivo imaging.However,because of severe scattering in biological samples,most of the emitted fluorescence photons go beyond the collection angles of objectives and thus cannot be detected.Here,we propose an extended detection scheme to enhance the collection of scattered photons in nonlinear fluorescence microscopy using a silicon photomultiplier array ahead of the front apertures of objectives.We perform numerical simulations to demonstrate the enhanced fluorescence collection via extended epi-detection in the multi-photon fluorescence imaging of human skin and mouse brain through craniotomy windows and intact skulls.For example,with red fluorescence emission at a depth of 600μm in human skin,the increased collection can be as much as about 150%with a 10×,0.6-NA objective.We show that extended epi-detection is a generally applicable,feasible technique for use in nonlinear fluorescence microscopy to enhance signal detection.展开更多
We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By i...We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By improvement of the electromagnetic shielding and introduction of the self-differencing method, the dark counts(DCs) are cut down to ~1%. We further develop an ultra-stable PMT cooling subsystem and observe that the DC goes down by a factor of 3.9 each time the temperature drops 10°C. At -20°C it is reduced 400 times with respect to the room temperature(25°C), that is, it becomes only 2 counts per second, which is on par with the superconducting nanowire detectors. Meanwhile, despite a 50% loss, the detection efficiency is still 13%. Our detector is available for ultra-precise single-photon detection in environments with strong electromagnetic disturbances.展开更多
This work aims at developing compact readout electronics for a compact imaging detector module with silicon photomultiplier (SPM) array. The detector module consists of a LYSO crystal array coupling with a SensL’s ...This work aims at developing compact readout electronics for a compact imaging detector module with silicon photomultiplier (SPM) array. The detector module consists of a LYSO crystal array coupling with a SensL’s 4×4 SPM array. A compact multiplexed readout based on a discretized positioning circuit (DPC) was developed to reduce the readout channels from 16 to 4 outputs. Different LYSO crystal arrays of 4×4, 8×8 and 12×12 with pixel sizes of 3.2, 1.6 and 1.0 mm respectively, have been tested with the compact readout board using a 137 Cs source. The initial results show that the compact imaging detector module with the compact multiplexed readout could clearly resolve 1 mm×1 mm×10 mm LYSO scintillation crystal array except those at the edges. The detector’s intrinsic spatial resolution up to 1 mm can be achieved with the 3 mm×3 mm size SPMArray4 through light sharing and compact multiplexed readout. Our results indicate that this detector module is feasible for the development of high-resolution compact PET.展开更多
The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approx...The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approximately~1 mW/channel.Owing to its dual-path gain,the BETA chip is capable of resolving single photoelectrons(phes)with a signal-to-noise ratio(SNR)>5 while simultaneously achieving a dynamic range of~4000 phes.Thus,BETA can provide a cost-effective solution for the readout of SiPMs in space missions and other applications with a maximum rate below 10 kHz.In this study,we describe the key characteristics of the BETA ASIC and present an evaluation of the performance of its 16-channel version,which is implemented using 130 nm technology.The ASIC also contains two discriminators that can provide trigger signals with a time jitter down to 400 ps FWHM for 10 phes.The linearity error of the charge gain measurement was less than 2%for a dynamic range as large as 15 bits.展开更多
The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction te...The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction techniques.Therefore,it is critical to measure the muon beam characteristics.We set up a muon beam monitor(MBM),where scintillating fibers woven in a cross shape were coupled to silicon photomultipliers to measure the spatial profile and timing structure of the extracted muon beam for the COMET.The MBM detector was tested successfully with a proton beamline at the China Spallation Neutron Source and took data with good performance in the commissioning run.The development of the MBM,including its mechanical structure,electronic readout,and beam measurement results,are discussed.展开更多
The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore ...The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements.展开更多
The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a conti...The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a continuous low-resistance cap layer and integrated quenching resisters in epitaxial silicon layer, which makes it possible to increase microcell density or reduce microcell size, thus obtaining large dynamic range and high photon detection efficiency(PDE) simultaneously. Results published show that the EQR SiPM with N-on-P diode configuration had relatively low PDE at peak wavelength of 480 nm as 16%. This paper reported the EQR SiPM with P-on-N diode configuration having active area of 3 × 3 mm^2 and cell density of 10,000/mm^2(total 90,000 pixels). It was characterized with gain of 2E5, dark count rate of 7 MHz, crosstalk of 7%, dynamic range of 85,000 pixels, overall recovery time of 32 ns at room temperature and over-voltage of 3.5 V. The improved PDE at peak wavelength of 420 nm was 30%.展开更多
With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system ac...With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system achieved by fieldprogrammable gate array-based charge-to-digital converter(FPGA-QDC)technology was built and developed.The FEE consists of an analog board and FPGA board.The analog board incorporates commercial amplifiers,resistors,and capacitors.The FPGA board is composed of a low-cost FPGA.The electronics performance of the FEE was evaluated in terms of noise,linearity,and uniformity.A positron emission tomography(PET)detector with three different readout configurations was designed to validate the readout capability of the FEE for SiPM-based detectors.The PET detector was made of a 15×15 lutetium–yttrium oxyorthosilicate(LYSO)crystal array directly coupled with a SiPM array detector.The experimental results show that FEE can process dual-polarity charge signals from the SiPM detectors.In addition,it shows a good energy resolution for 511-keV gamma photons under the dual-end readout for the LYSO crystal array irradiated by a Na-22 source.Overall,the FEE based on FPGA-QDC shows promise for application in SiPM-based radiation detectors.展开更多
Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The pre...Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The preamplifier demonstrated a good gain stability,bandwidth of 426 MHz,baseline noise level ofσ≈0.6 mV,dynamic range of up to170 mV of the input signal amplitude,good time resolution of 20 ps,and it can be comprehensively applied to SiPMs.Adopting pole-zero-cancelation in the preamplifier reduces both the rise and fall times of the SiPM signal,which can significantly improve the time resolution and reduce the pile-up when using a large SiPM or an array of SiPMs.Various combinations of the preamplifier and several types of SiPMs demonstrated time resolutions better than 50 ps for most cases;when the number of detected photons was larger than 60,a time resolution of approximately 25 ps was achieved.展开更多
This paper proposes two optimal designs of single photon avalanche diodes(SPADs) minimizing dark count rate(DCR). The first structure is introduced as p^+/pwell/nwell, in which a specific shallow pwell layer is added ...This paper proposes two optimal designs of single photon avalanche diodes(SPADs) minimizing dark count rate(DCR). The first structure is introduced as p^+/pwell/nwell, in which a specific shallow pwell layer is added between p^+and nwell layers to decrease the electric field below a certain threshold. The simulation results show on average 19.7%and 8.5% reduction of p^+/nwell structure’s DCR comparing with similar previous structures in different operational excess bias and temperatures respectively. Moreover, a new structure is introduced as n+/nwell/pwell, in which a specific shallow nwell layer is added between n+and pwell layers to lower the electric field below a certain threshold. The simulation results show on average 29.2% and 5.5% decrement of p^+/nwell structure’s DCR comparing with similar previous structures in different operational excess bias and temperatures respectively. It is shown that in higher excess biases(about 6 volts), the n+/nwell/pwell structure is proper to be integrated as digital silicon photomultiplier(dSiPM) due to low DCR. On the other hand, the p^+/pwell/nwell structure is appropriate to be utilized in dSiPM in high temperatures(above 50?C) due to lower DCR value.展开更多
An OH radical measurement instrument based on Fluorescence Assay by Gas Expansion(FAGE)has been developed in our laboratory.Ambient air is introduced into a low-pressure fluorescence cell through a pinhole aperture ...An OH radical measurement instrument based on Fluorescence Assay by Gas Expansion(FAGE)has been developed in our laboratory.Ambient air is introduced into a low-pressure fluorescence cell through a pinhole aperture and irradiated by a dye laser at a high repetition rate of 8.5 k Hz.The OH radical is both excited and detected at 308 nm using A-X(0,0)band.To satisfy the high efficiency needs of fluorescence collection and detection,a 4-lens optical system and a self-designed gated photomultiplier(PMT)is used,and gating is actualized by switching the voltage applied on the PMT dynodes.A micro channel photomultiplier(MCP)is also prepared for fluorescence detection.Then the weak signal is accumulated by a photon counter in a specific timing.The OH radical excitation spectrum range in the wavelength of 307.82–308.2 nm is detected and the excited line for OH detection is determined to be Q1(2)line.The calibration of the FAGE system is researched by using simultaneous photolysis of H2O and O2.The minimum detection limit of the instrument using gated PMT is determined to be 9.4×10~5molecules/cm^3,and the sensitivity is 9.5×10^(-7)cps/(OH·cm^(-3)),with a signal-to-noise ratio of 2 and an integration time of 60 sec,while OH detection limit and the detection sensitivity using MCP is calculated to be 1.6×10~5molecules/cm^3and 2.3×10^(-6)cps/(OH·cm^(-3)).The laboratory OH radical measurement is carried out and results show that the proposed system can be used for atmospheric OH radical measurement.展开更多
A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Li...A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Linux+Apache+MySQL+PHP(LAMP)server and focuses on modularization and architecture separation.It covers all the testing stages for the 20-inch photomultiplier tubes(PMTs)at JUNO and provides its users with data storage,analysis,and visualization services.Based on the successful use of the system in the 20-inch PMT testing program,its design approach and construction elements can be extended to other projects.展开更多
Preliminary results of recent experiments performed within the Mather-type 112.5 J plasma focus device are presented. The ion beams from the focus device operated with deuterium filling at 1 mbar were registered using...Preliminary results of recent experiments performed within the Mather-type 112.5 J plasma focus device are presented. The ion beams from the focus device operated with deuterium filling at 1 mbar were registered using CR-39 solid state nuclear track detectors (SSNTD) and a Faraday cup detector for time-resolved measurements. The time-resolved neutron emission from the focus region measurements was detected with a photomultiplier tube (IP-28) optically coupled with a plastic scintillator NE 102.展开更多
The detection of low-level light is a key technology in various experimental scientific studies. As a photon detector, the silicon photomultiplier (SiPM) has gradually become an alternative to the photomultiplier tu...The detection of low-level light is a key technology in various experimental scientific studies. As a photon detector, the silicon photomultiplier (SiPM) has gradually become an alternative to the photomultiplier tube (PMT) in many applications in high-energy physics, astroparticle physics, and medical imaging because of its high photon detection efficiency (PDE), good resolution for single-photon detection, insensitivity to magnetic field, low operating voltage, compactness, and low cost. However, primarily because of the geometric fill factor, the PDE of most SiPMs is not very high; in particular, for those SiPMs with a high density of micro cells, the effective area is small, and the bandwidth of the light response is narrow. As a building block of the SiPM, the concept of the backside-illuminated avalanche drift detector (ADD) was first proposed by the Max Planck Institute of Germany eight years ago; the ADD is promising to have high PDE over the full energy range of optical photons, even ultraviolet light and X-ray light, and because the avalanche multiplication region is very small, the ADD is beneficial for the fabrication of large-area SiPMs. However, because of difficulties in design and fabrication, no significant progress had been made, and the concept had not yet been verified. In this paper, preliminary results in the design, fabrication, and performance of a backside-illuminated ADD are reported; the difficulties in and limitations to the backside-illuminated ADD are analyzed.展开更多
文摘The service provided by the GC(Gamma Cameras)in the Nuclear Medicine departments fails because of their breakdown,generally due to the associated electronics and not to the physical detection components.For this reason,it was decided to develop an electronic system that allows the recovery and optimization of disused GC,starting with the design of the preamplifier for a PMT(photomultiplier tube).The circuit was designed and simulated and the list of components necessary for the construction of the preamplifier was generated,as well as the printed circuit board was designed for its assembly.By simulating the preamplifier this worked in linear mode.This determines that the amplitude of the output signal is proportional to the amount of charge delivered by the detector.This card allows an automatic adjustment of the signals of the PMT as do the modern GC.
基金the National Natural Science Foundation of China(Grant Nos.11875273,U1832111,61964001,and 12275049)the Science Foundation of Guangdong Province of China(Grant No.2020B1515120025)+3 种基金the Neutron Physics Laboratory Funding of China Academy of Engineering Physics(Grant No.2018BC03)the General Project of Jiangxi Province Key Research and Development Program(Grant No.20212BBG73012)the Key Scientific Research Projects of Henan Higher Education Institutions(Grant Nos.23A490002 and 24A490001)the Engineering Research Center of Nuclear Technology Application(Grant No.HJSJYB2021-4)。
文摘The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.
基金National Institute of Biomedical Imaging and Bioengineering(R21-EB032839)National Cancer Institute(R37-CA258376)。
文摘Two-photon fluorescence microscopy(TPFM)is widely used for imaging of biological tissue due to its robustness to scattering,high resolution,and ease of multiplexing fluorescent probes.However,TPFM volumetric imaging rates are typically low,limiting the ability to image whole cleared tissues and large surgical specimens.While innovations in TPFM technology,such as parallel-scanning,have drastically increased imaging speed,these improvements have typically focused on high frame rate,single field-of-view imaging rather than extending the area/volume imaging rate.In this work,we bridge the gap between high imaging speed and high area and volumetric imaging throughput by combining parallel scanning with tilted-plane strip-scanning using custom silicon photomultiplier(SiPM)tiled-array detectors.We demonstrate 200 MP/s with four spectral channels(800 MSpectra/s)and an effective area imaging speed of up to 52 mm^(2)∕s using four parallel beams.Custom detectors and lens array enable non-descanned imaging with minimal crosstalk combined with light collection efficiency comparable to a conventional single-point scanning TPFM.Finally,the low-cost of the custom detectors(∼$250 per channel)and the scalability of the detection optics allow for ease of spectral multiplexing.
基金support from the National Natural Science Foundation of China(No.12002386).
文摘Self-excited longitudinal combustion instabilities were investigated in a hypergolic liquid bipropellant combustor, which applied single dual-swirl coaxial injector. Hot-fire tests were conducted for four different injector geometries, while extensive tests on injection conditions were carried out for each injector geometry. The synchronous measurement of the pressure and heat release rate was applied, successfully capturing the process of the pressure and heat release rate enhanced coupling and developing into in-phase oscillation. By calculating Rayleigh index at the head and middle section of the chamber, it is shown that Rayleigh index of the middle section is even higher than that of the head, indicating a long heat release zone. When the combustion instability occurs, the pressure in propellant manifolds also oscillates with the same frequency and lags behind the oscillation in the combustor. Compared to the oscillation in the outer injector manifold, the oscillation in the inner injector manifold shows a higher correlation with that in the chamber in amplitude and phase. Based on numerical simulations of the multiphase cold flow inside the injector and combustion process in the chamber, it is found that injector geometries affect longitudinal combustion instability by changing spray cone angle. The spray with small cone angle is more sensitive to the modulation of longitudinal pressure wave in combustion simulations, which is more likely to excite the longitudinal combustion instability. Meanwhile, the combustion instability may be related to the pulsating coherent structure generated by the spray fluctuation, which is determined by injection conditions. Besides, a positive feedback closed-loop system associated with the active fluctuation and passive oscillation of the spray is believed to excite and sustain the longitudinal combustion instability.
基金Project supported by the National Natural Science Foundation of China (Grant No. 12275181)Guangdong Basic and Applied Basic Research Foundation (Grant No. 2022B1515120071)+1 种基金Promotion Project of Scientific Research Capability of Key Construction Disciplines in Guangdong Province (Grant No. 2022ZDJS118)Natural Science Foundation of Top Talent SZTU (Grant No. GDRC202205)。
文摘Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency, high position resolution,and large-area splicing, and can well meet the requirement of large area neutron detection for neutron diffractometers. An engineering detector prototype based on a ~6LiF/ZnS(Ag) scintillation screen and SiPM array readout was fabricated for the General Purpose Powder Diffractometer of China Spallation Neutron Source(CSNS). The detector has an active area of 196 mm × 444 mm, with a pixel size of 4 mm × 4 mm. The key performances of the detector prototype were tested at the BL20 neutron beam line of CSNS. The test results show that the neutron detection efficiency of the detector was 32% and 42% at wavelengths of 1.4 ? and 2.8 ?, respectively. An interpolated neutron detection efficiency of 40.2% at a wavelength of 2 ? was obtained. The tested neutron efficiency non-uniformity of the detector was 10.2%, which is less than one-half that of the current general purpose powder diffractometer scintillator neutron detectors at CSNS. This work achieves, for the first time, an efficiency uniformity of < 11% in large-area mosaic neutron detectors, alongside significant advancements in electromagnetic interference immunity and cost-effectiveness.
基金Supported by National High Technology Research and Development Program of China (2007AA12Z133)
文摘Silicon photomultipliers (SiPMs) are a new generation of semiconductor-based photon counting devices with the merits of low weight, low power consumption and low voltage operation, promising to meet the needs of space particle physics experiments. In this paper, comparative studies of SiPMs and traditional vacuum photomultiplier tubes (PMTs) have been performed regarding the basic properties of dark currents, dark counts and excess noise factors. The intrinsic optical erosstalk effect of SiPMs was evaluated.
基金Project supported by the National Natural Science Foundation of China(Nos.61831014 and 61771287)the Tsinghua University Initiative Scientific Research Program,China(No.20193080076)the Graduate Education Innovation Grants,Tsinghua University,China(No.201905J003)。
文摘To maximize signal collection in nonlinear optical microscopy,non-descanned epi-detection is generally adopted for in vivo imaging.However,because of severe scattering in biological samples,most of the emitted fluorescence photons go beyond the collection angles of objectives and thus cannot be detected.Here,we propose an extended detection scheme to enhance the collection of scattered photons in nonlinear fluorescence microscopy using a silicon photomultiplier array ahead of the front apertures of objectives.We perform numerical simulations to demonstrate the enhanced fluorescence collection via extended epi-detection in the multi-photon fluorescence imaging of human skin and mouse brain through craniotomy windows and intact skulls.For example,with red fluorescence emission at a depth of 600μm in human skin,the increased collection can be as much as about 150%with a 10×,0.6-NA objective.We show that extended epi-detection is a generally applicable,feasible technique for use in nonlinear fluorescence microscopy to enhance signal detection.
基金supported by the National Natural Science Foundation of China(Nos.11574026 and 11274037)the Program for New Century Excellent Talents in University,MOE of China(No.NCET-12-0765)the Foundation for the Author of National Excellent Doctoral Dissertation,China(No.201236)
文摘We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By improvement of the electromagnetic shielding and introduction of the self-differencing method, the dark counts(DCs) are cut down to ~1%. We further develop an ultra-stable PMT cooling subsystem and observe that the DC goes down by a factor of 3.9 each time the temperature drops 10°C. At -20°C it is reduced 400 times with respect to the room temperature(25°C), that is, it becomes only 2 counts per second, which is on par with the superconducting nanowire detectors. Meanwhile, despite a 50% loss, the detection efficiency is still 13%. Our detector is available for ultra-precise single-photon detection in environments with strong electromagnetic disturbances.
基金Supported by National Natural Science Foundation of China (10875162, 1105209)
文摘This work aims at developing compact readout electronics for a compact imaging detector module with silicon photomultiplier (SPM) array. The detector module consists of a LYSO crystal array coupling with a SensL’s 4×4 SPM array. A compact multiplexed readout based on a discretized positioning circuit (DPC) was developed to reduce the readout channels from 16 to 4 outputs. Different LYSO crystal arrays of 4×4, 8×8 and 12×12 with pixel sizes of 3.2, 1.6 and 1.0 mm respectively, have been tested with the compact readout board using a 137 Cs source. The initial results show that the compact imaging detector module with the compact multiplexed readout could clearly resolve 1 mm×1 mm×10 mm LYSO scintillation crystal array except those at the edges. The detector’s intrinsic spatial resolution up to 1 mm can be achieved with the 3 mm×3 mm size SPMArray4 through light sharing and compact multiplexed readout. Our results indicate that this detector module is feasible for the development of high-resolution compact PET.
基金support from Grant PID2020-116075GB-C21funded by MCIN/AEI/10.13039/501100011033+1 种基金by“ERDF A way of making Europe”under Grant PID2020-116075GB-C21They also acknowledge financial support from the State Agency for Research of the Spanish Ministry of Science and Innovation through the“Unit of Excellence Maria de Maeztu 2020-2023”award to the Institute of Cosmos Sciences(CEX2019-000918-M)。
文摘The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approximately~1 mW/channel.Owing to its dual-path gain,the BETA chip is capable of resolving single photoelectrons(phes)with a signal-to-noise ratio(SNR)>5 while simultaneously achieving a dynamic range of~4000 phes.Thus,BETA can provide a cost-effective solution for the readout of SiPMs in space missions and other applications with a maximum rate below 10 kHz.In this study,we describe the key characteristics of the BETA ASIC and present an evaluation of the performance of its 16-channel version,which is implemented using 130 nm technology.The ASIC also contains two discriminators that can provide trigger signals with a time jitter down to 400 ps FWHM for 10 phes.The linearity error of the charge gain measurement was less than 2%for a dynamic range as large as 15 bits.
基金supported in part by Fundamental Research Funds for the Central Universities(23xkjc017)at Sun Yat-sen Universitythe National Natural Science Foundation of China(No.12075326)JSPS KAKENHI(No.22H00139)。
文摘The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction techniques.Therefore,it is critical to measure the muon beam characteristics.We set up a muon beam monitor(MBM),where scintillating fibers woven in a cross shape were coupled to silicon photomultipliers to measure the spatial profile and timing structure of the extracted muon beam for the COMET.The MBM detector was tested successfully with a proton beamline at the China Spallation Neutron Source and took data with good performance in the commissioning run.The development of the MBM,including its mechanical structure,electronic readout,and beam measurement results,are discussed.
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(KJCX2-YW-N27)the CAS Center for Excellence in Particle Physics(CCEPP)
文摘The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements.
基金supported by the National Natural Science Foundation of China(Nos.61534005,11475025 and 11375029)
文摘The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a continuous low-resistance cap layer and integrated quenching resisters in epitaxial silicon layer, which makes it possible to increase microcell density or reduce microcell size, thus obtaining large dynamic range and high photon detection efficiency(PDE) simultaneously. Results published show that the EQR SiPM with N-on-P diode configuration had relatively low PDE at peak wavelength of 480 nm as 16%. This paper reported the EQR SiPM with P-on-N diode configuration having active area of 3 × 3 mm^2 and cell density of 10,000/mm^2(total 90,000 pixels). It was characterized with gain of 2E5, dark count rate of 7 MHz, crosstalk of 7%, dynamic range of 85,000 pixels, overall recovery time of 32 ns at room temperature and over-voltage of 3.5 V. The improved PDE at peak wavelength of 420 nm was 30%.
基金supported by the Natural Science Foundation of Shandong Province (No. ZR2022QA039)the Program of Qilu Young Scholars of Shandong University
文摘With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system achieved by fieldprogrammable gate array-based charge-to-digital converter(FPGA-QDC)technology was built and developed.The FEE consists of an analog board and FPGA board.The analog board incorporates commercial amplifiers,resistors,and capacitors.The FPGA board is composed of a low-cost FPGA.The electronics performance of the FEE was evaluated in terms of noise,linearity,and uniformity.A positron emission tomography(PET)detector with three different readout configurations was designed to validate the readout capability of the FEE for SiPM-based detectors.The PET detector was made of a 15×15 lutetium–yttrium oxyorthosilicate(LYSO)crystal array directly coupled with a SiPM array detector.The experimental results show that FEE can process dual-polarity charge signals from the SiPM detectors.In addition,it shows a good energy resolution for 511-keV gamma photons under the dual-end readout for the LYSO crystal array irradiated by a Na-22 source.Overall,the FEE based on FPGA-QDC shows promise for application in SiPM-based radiation detectors.
基金This work was partially supported by the National Key R&D Program of China(No.2022YFA1601903)the National Natural Science Foundation of China(Nos.11925502,11961141003,and 12175041)the Strategic Priority Research Program of the CAS(No.XDB34030000).
文摘Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The preamplifier demonstrated a good gain stability,bandwidth of 426 MHz,baseline noise level ofσ≈0.6 mV,dynamic range of up to170 mV of the input signal amplitude,good time resolution of 20 ps,and it can be comprehensively applied to SiPMs.Adopting pole-zero-cancelation in the preamplifier reduces both the rise and fall times of the SiPM signal,which can significantly improve the time resolution and reduce the pile-up when using a large SiPM or an array of SiPMs.Various combinations of the preamplifier and several types of SiPMs demonstrated time resolutions better than 50 ps for most cases;when the number of detected photons was larger than 60,a time resolution of approximately 25 ps was achieved.
文摘This paper proposes two optimal designs of single photon avalanche diodes(SPADs) minimizing dark count rate(DCR). The first structure is introduced as p^+/pwell/nwell, in which a specific shallow pwell layer is added between p^+and nwell layers to decrease the electric field below a certain threshold. The simulation results show on average 19.7%and 8.5% reduction of p^+/nwell structure’s DCR comparing with similar previous structures in different operational excess bias and temperatures respectively. Moreover, a new structure is introduced as n+/nwell/pwell, in which a specific shallow nwell layer is added between n+and pwell layers to lower the electric field below a certain threshold. The simulation results show on average 29.2% and 5.5% decrement of p^+/nwell structure’s DCR comparing with similar previous structures in different operational excess bias and temperatures respectively. It is shown that in higher excess biases(about 6 volts), the n+/nwell/pwell structure is proper to be integrated as digital silicon photomultiplier(dSiPM) due to low DCR. On the other hand, the p^+/pwell/nwell structure is appropriate to be utilized in dSiPM in high temperatures(above 50?C) due to lower DCR value.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. XDB05040200)the National Natural Science Foundation of China (Grant Nos. 91644107, 61575206, 41305139, 61108031)
文摘An OH radical measurement instrument based on Fluorescence Assay by Gas Expansion(FAGE)has been developed in our laboratory.Ambient air is introduced into a low-pressure fluorescence cell through a pinhole aperture and irradiated by a dye laser at a high repetition rate of 8.5 k Hz.The OH radical is both excited and detected at 308 nm using A-X(0,0)band.To satisfy the high efficiency needs of fluorescence collection and detection,a 4-lens optical system and a self-designed gated photomultiplier(PMT)is used,and gating is actualized by switching the voltage applied on the PMT dynodes.A micro channel photomultiplier(MCP)is also prepared for fluorescence detection.Then the weak signal is accumulated by a photon counter in a specific timing.The OH radical excitation spectrum range in the wavelength of 307.82–308.2 nm is detected and the excited line for OH detection is determined to be Q1(2)line.The calibration of the FAGE system is researched by using simultaneous photolysis of H2O and O2.The minimum detection limit of the instrument using gated PMT is determined to be 9.4×10~5molecules/cm^3,and the sensitivity is 9.5×10^(-7)cps/(OH·cm^(-3)),with a signal-to-noise ratio of 2 and an integration time of 60 sec,while OH detection limit and the detection sensitivity using MCP is calculated to be 1.6×10~5molecules/cm^3and 2.3×10^(-6)cps/(OH·cm^(-3)).The laboratory OH radical measurement is carried out and results show that the proposed system can be used for atmospheric OH radical measurement.
基金supported by the National Natural Science Foundation of China (No. 11675273)the Strategic Priority Research Program of the Chinese Academy of Sciences (No. XDA10011102)
文摘A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Linux+Apache+MySQL+PHP(LAMP)server and focuses on modularization and architecture separation.It covers all the testing stages for the 20-inch photomultiplier tubes(PMTs)at JUNO and provides its users with data storage,analysis,and visualization services.Based on the successful use of the system in the 20-inch PMT testing program,its design approach and construction elements can be extended to other projects.
文摘Preliminary results of recent experiments performed within the Mather-type 112.5 J plasma focus device are presented. The ion beams from the focus device operated with deuterium filling at 1 mbar were registered using CR-39 solid state nuclear track detectors (SSNTD) and a Faraday cup detector for time-resolved measurements. The time-resolved neutron emission from the focus region measurements was detected with a photomultiplier tube (IP-28) optically coupled with a plastic scintillator NE 102.
基金Project supported by the National Natural Science Foundation of China(Grant No.11005010)
文摘The detection of low-level light is a key technology in various experimental scientific studies. As a photon detector, the silicon photomultiplier (SiPM) has gradually become an alternative to the photomultiplier tube (PMT) in many applications in high-energy physics, astroparticle physics, and medical imaging because of its high photon detection efficiency (PDE), good resolution for single-photon detection, insensitivity to magnetic field, low operating voltage, compactness, and low cost. However, primarily because of the geometric fill factor, the PDE of most SiPMs is not very high; in particular, for those SiPMs with a high density of micro cells, the effective area is small, and the bandwidth of the light response is narrow. As a building block of the SiPM, the concept of the backside-illuminated avalanche drift detector (ADD) was first proposed by the Max Planck Institute of Germany eight years ago; the ADD is promising to have high PDE over the full energy range of optical photons, even ultraviolet light and X-ray light, and because the avalanche multiplication region is very small, the ADD is beneficial for the fabrication of large-area SiPMs. However, because of difficulties in design and fabrication, no significant progress had been made, and the concept had not yet been verified. In this paper, preliminary results in the design, fabrication, and performance of a backside-illuminated ADD are reported; the difficulties in and limitations to the backside-illuminated ADD are analyzed.