期刊文献+
共找到41篇文章
< 1 2 3 >
每页显示 20 50 100
Design of a Preamplifier Card for the Photomultiplier Tubes of a Gamma Camera 被引量:2
1
作者 Jorge Luis Domínguez Martínez 《Journal of Physical Science and Application》 2018年第1期46-54,共9页
The service provided by the GC(Gamma Cameras)in the Nuclear Medicine departments fails because of their breakdown,generally due to the associated electronics and not to the physical detection components.For this reaso... The service provided by the GC(Gamma Cameras)in the Nuclear Medicine departments fails because of their breakdown,generally due to the associated electronics and not to the physical detection components.For this reason,it was decided to develop an electronic system that allows the recovery and optimization of disused GC,starting with the design of the preamplifier for a PMT(photomultiplier tube).The circuit was designed and simulated and the list of components necessary for the construction of the preamplifier was generated,as well as the printed circuit board was designed for its assembly.By simulating the preamplifier this worked in linear mode.This determines that the amplitude of the output signal is proportional to the amount of charge delivered by the detector.This card allows an automatic adjustment of the signals of the PMT as do the modern GC. 展开更多
关键词 GAMMA camera NUCLEAR medicine photomultiplier tube PREAMPLIFIER CUBA
在线阅读 下载PDF
Silicon photomultiplier based scintillator thermal neutron detector for China Spallation Neutron Source(CSNS) 被引量:1
2
作者 岳秀萍 朱志甫 +11 位作者 唐彬 黄畅 于潜 陈少佳 王修库 许虹 周诗慧 蔡小杰 杨浩 万志勇 孙志嘉 刘云涛 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期35-41,共7页
The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors wi... The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS. 展开更多
关键词 neutron detector silicon photomultipliers(SiPMs) ^(6)LiF/ZnS(Ag) China Spallation Neutron Source(CSNS)
原文传递
High area and volumetric throughput parallel two-photon fluorescence microscopy using silicon photomultiplier arrays
3
作者 VINCENT D.CHING-ROA CHI Z.HUANG MICHAEL G.GIACOMELLI 《Photonics Research》 2025年第9期2704-2717,共14页
Two-photon fluorescence microscopy(TPFM)is widely used for imaging of biological tissue due to its robustness to scattering,high resolution,and ease of multiplexing fluorescent probes.However,TPFM volumetric imaging r... Two-photon fluorescence microscopy(TPFM)is widely used for imaging of biological tissue due to its robustness to scattering,high resolution,and ease of multiplexing fluorescent probes.However,TPFM volumetric imaging rates are typically low,limiting the ability to image whole cleared tissues and large surgical specimens.While innovations in TPFM technology,such as parallel-scanning,have drastically increased imaging speed,these improvements have typically focused on high frame rate,single field-of-view imaging rather than extending the area/volume imaging rate.In this work,we bridge the gap between high imaging speed and high area and volumetric imaging throughput by combining parallel scanning with tilted-plane strip-scanning using custom silicon photomultiplier(SiPM)tiled-array detectors.We demonstrate 200 MP/s with four spectral channels(800 MSpectra/s)and an effective area imaging speed of up to 52 mm^(2)∕s using four parallel beams.Custom detectors and lens array enable non-descanned imaging with minimal crosstalk combined with light collection efficiency comparable to a conventional single-point scanning TPFM.Finally,the low-cost of the custom detectors(∼$250 per channel)and the scalability of the detection optics allow for ease of spectral multiplexing. 展开更多
关键词 imaging biological tissue cleared tissues volumetric throughput surgical specimenswhile silicon photomultiplier arrays tilted plane strip scanning two photon fluorescence microscopy high area imaging
原文传递
Longitudinal combustion instability in a hypergolic liquid bipropellant combustor with single dual-swirl coaxial injector
4
作者 Wei CHU Kangkang GUO +3 位作者 Yiheng TONG Yongjie REN Boqi XU Wansheng NIE 《Chinese Journal of Aeronautics》 2025年第3期280-291,共12页
Self-excited longitudinal combustion instabilities were investigated in a hypergolic liquid bipropellant combustor, which applied single dual-swirl coaxial injector. Hot-fire tests were conducted for four different in... Self-excited longitudinal combustion instabilities were investigated in a hypergolic liquid bipropellant combustor, which applied single dual-swirl coaxial injector. Hot-fire tests were conducted for four different injector geometries, while extensive tests on injection conditions were carried out for each injector geometry. The synchronous measurement of the pressure and heat release rate was applied, successfully capturing the process of the pressure and heat release rate enhanced coupling and developing into in-phase oscillation. By calculating Rayleigh index at the head and middle section of the chamber, it is shown that Rayleigh index of the middle section is even higher than that of the head, indicating a long heat release zone. When the combustion instability occurs, the pressure in propellant manifolds also oscillates with the same frequency and lags behind the oscillation in the combustor. Compared to the oscillation in the outer injector manifold, the oscillation in the inner injector manifold shows a higher correlation with that in the chamber in amplitude and phase. Based on numerical simulations of the multiphase cold flow inside the injector and combustion process in the chamber, it is found that injector geometries affect longitudinal combustion instability by changing spray cone angle. The spray with small cone angle is more sensitive to the modulation of longitudinal pressure wave in combustion simulations, which is more likely to excite the longitudinal combustion instability. Meanwhile, the combustion instability may be related to the pulsating coherent structure generated by the spray fluctuation, which is determined by injection conditions. Besides, a positive feedback closed-loop system associated with the active fluctuation and passive oscillation of the spray is believed to excite and sustain the longitudinal combustion instability. 展开更多
关键词 Longitudinal combustion instability Dual-swirl coaxial injector Unsymmetrical Dimethylhydrazine/Nitrogen Tetroxide(UDMH/NTO) photomultiplier Tubes(PMT) Spray fluctuation Pressure wave Modulation
原文传递
A large-area scintillation neutron detector based on WLSF and SiPM readout
5
作者 Xiao-Hu Wang Yang-Tu Lu +4 位作者 Bin Tang Xiu-Ku Wang Shao-Jia Chen Ze-Ren Li Zhi-Jia Sun 《Chinese Physics B》 2025年第6期192-197,共6页
Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency... Position-sensitive neutron detectors play an important role in neutron scattering studies. Detectors based on ~6LiF/ZnS(Ag) scintillator and wave-shifting fiber have the advantages of high neutron detection efficiency, high position resolution,and large-area splicing, and can well meet the requirement of large area neutron detection for neutron diffractometers. An engineering detector prototype based on a ~6LiF/ZnS(Ag) scintillation screen and SiPM array readout was fabricated for the General Purpose Powder Diffractometer of China Spallation Neutron Source(CSNS). The detector has an active area of 196 mm × 444 mm, with a pixel size of 4 mm × 4 mm. The key performances of the detector prototype were tested at the BL20 neutron beam line of CSNS. The test results show that the neutron detection efficiency of the detector was 32% and 42% at wavelengths of 1.4 ? and 2.8 ?, respectively. An interpolated neutron detection efficiency of 40.2% at a wavelength of 2 ? was obtained. The tested neutron efficiency non-uniformity of the detector was 10.2%, which is less than one-half that of the current general purpose powder diffractometer scintillator neutron detectors at CSNS. This work achieves, for the first time, an efficiency uniformity of < 11% in large-area mosaic neutron detectors, alongside significant advancements in electromagnetic interference immunity and cost-effectiveness. 展开更多
关键词 scintillation neutron detector silicon photomultiplier position sensitive neutron detector
原文传递
Comparative studies of silicon photomultipliers and traditional vacuum photomultiplier tubes 被引量:3
6
作者 石峰 吕军光 +24 位作者 卢红 王焕玉 马宇蒨 胡涛 周莉 蔡啸 孙丽君 俞伯祥 方建 谢宇广 安正华 王志刚 高旻 李新乔 徐岩冰 王平 孙希磊 章爱武 薛镇 刘宏邦 王晓东 赵小芸 郑阳恒 孟祥承 王辉 《Chinese Physics C》 SCIE CAS CSCD 2011年第1期50-55,共6页
Silicon photomultipliers (SiPMs) are a new generation of semiconductor-based photon counting devices with the merits of low weight, low power consumption and low voltage operation, promising to meet the needs of spa... Silicon photomultipliers (SiPMs) are a new generation of semiconductor-based photon counting devices with the merits of low weight, low power consumption and low voltage operation, promising to meet the needs of space particle physics experiments. In this paper, comparative studies of SiPMs and traditional vacuum photomultiplier tubes (PMTs) have been performed regarding the basic properties of dark currents, dark counts and excess noise factors. The intrinsic optical erosstalk effect of SiPMs was evaluated. 展开更多
关键词 silicon photomultiplier SIPM PMT dark current dark counts excess noise factor
原文传递
Enhanced collection of scattered photons in nonlinear fluorescence microscopy by extended epi-detection with a silicon photomultiplier array 被引量:2
7
作者 Ruheng SHI Cheng JIN +1 位作者 Chi LIU Lingjie KONG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2021年第10期1289-1298,共10页
To maximize signal collection in nonlinear optical microscopy,non-descanned epi-detection is generally adopted for in vivo imaging.However,because of severe scattering in biological samples,most of the emitted fluores... To maximize signal collection in nonlinear optical microscopy,non-descanned epi-detection is generally adopted for in vivo imaging.However,because of severe scattering in biological samples,most of the emitted fluorescence photons go beyond the collection angles of objectives and thus cannot be detected.Here,we propose an extended detection scheme to enhance the collection of scattered photons in nonlinear fluorescence microscopy using a silicon photomultiplier array ahead of the front apertures of objectives.We perform numerical simulations to demonstrate the enhanced fluorescence collection via extended epi-detection in the multi-photon fluorescence imaging of human skin and mouse brain through craniotomy windows and intact skulls.For example,with red fluorescence emission at a depth of 600μm in human skin,the increased collection can be as much as about 150%with a 10×,0.6-NA objective.We show that extended epi-detection is a generally applicable,feasible technique for use in nonlinear fluorescence microscopy to enhance signal detection. 展开更多
关键词 Extended epi-detection Enhanced collection Nonlinear fluorescence microscopy Silicon photomultiplier array
原文传递
Ultralow-noise single-photon detection based on precise temperature controlled photomultiplier with enhanced electromagnetic shielding 被引量:1
8
作者 Mingyu Wang Zhengyong Li +4 位作者 Yanhui Cai Yi Zhang Xiangkong Zhan Haiyang Wang Chongqing Wu 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第10期7-10,共4页
We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By i... We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By improvement of the electromagnetic shielding and introduction of the self-differencing method, the dark counts(DCs) are cut down to ~1%. We further develop an ultra-stable PMT cooling subsystem and observe that the DC goes down by a factor of 3.9 each time the temperature drops 10°C. At -20°C it is reduced 400 times with respect to the room temperature(25°C), that is, it becomes only 2 counts per second, which is on par with the superconducting nanowire detectors. Meanwhile, despite a 50% loss, the detection efficiency is still 13%. Our detector is available for ultra-precise single-photon detection in environments with strong electromagnetic disturbances. 展开更多
关键词 PMT Ultralow-noise single-photon detection based on precise temperature controlled photomultiplier with enhanced electromagnetic shielding
原文传递
Design and development of compact readout electronics with silicon photomultiplier array for a compact imaging detector
9
作者 张晓慧 漆玉金 赵翠兰 《Chinese Physics C》 SCIE CAS CSCD 2012年第10期973-978,共6页
This work aims at developing compact readout electronics for a compact imaging detector module with silicon photomultiplier (SPM) array. The detector module consists of a LYSO crystal array coupling with a SensL’s ... This work aims at developing compact readout electronics for a compact imaging detector module with silicon photomultiplier (SPM) array. The detector module consists of a LYSO crystal array coupling with a SensL’s 4×4 SPM array. A compact multiplexed readout based on a discretized positioning circuit (DPC) was developed to reduce the readout channels from 16 to 4 outputs. Different LYSO crystal arrays of 4×4, 8×8 and 12×12 with pixel sizes of 3.2, 1.6 and 1.0 mm respectively, have been tested with the compact readout board using a 137 Cs source. The initial results show that the compact imaging detector module with the compact multiplexed readout could clearly resolve 1 mm×1 mm×10 mm LYSO scintillation crystal array except those at the edges. The detector’s intrinsic spatial resolution up to 1 mm can be achieved with the 3 mm×3 mm size SPMArray4 through light sharing and compact multiplexed readout. Our results indicate that this detector module is feasible for the development of high-resolution compact PET. 展开更多
关键词 position readout electronics silicon photomultiplier array compact imaging detector
原文传递
Low-power SiPM readout BETA ASIC for space applications
10
作者 Anand Sanmukh Sergio Gómez +9 位作者 Albert Comerma Joan Mauricio Rafel Manera Andreu Sanuy Daniel Guberman Roger Catala Albert Espinya Marina Orta Oscar de la Torre David Gascon 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期153-169,共17页
The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approx... The BETA application-specific integrated circuit(ASIC)is a fully programmable chip designed to amplify,shape and digitize the signal of up to 64 Silicon photomultiplier(SiPM)channels,with a power consumption of approximately~1 mW/channel.Owing to its dual-path gain,the BETA chip is capable of resolving single photoelectrons(phes)with a signal-to-noise ratio(SNR)>5 while simultaneously achieving a dynamic range of~4000 phes.Thus,BETA can provide a cost-effective solution for the readout of SiPMs in space missions and other applications with a maximum rate below 10 kHz.In this study,we describe the key characteristics of the BETA ASIC and present an evaluation of the performance of its 16-channel version,which is implemented using 130 nm technology.The ASIC also contains two discriminators that can provide trigger signals with a time jitter down to 400 ps FWHM for 10 phes.The linearity error of the charge gain measurement was less than 2%for a dynamic range as large as 15 bits. 展开更多
关键词 Radiation detectors Silicon photomultipliers Photon sensors Front-end electronics Mixed-mode ASICs Space technology
在线阅读 下载PDF
Development of a scintillating-fiber-based beam monitor for the coherent muon-to-electron transition experiment
11
作者 Yu Xu Yun-Song Ning +7 位作者 Zhi-Zhen Qin Yao Teng Chang-Qing Feng Jian Tang Yu Chen Yoshinori Fukao Satoshi Mihara Kou Oishi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期156-164,共9页
The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction te... The coherent muon-to-electron transition(COMET)experiment is a leading experiment for the coherent conversion of μ^(-)N→e^(-)N using a high-intensity pulsed muon beamline,produced using innovative slow-extraction techniques.Therefore,it is critical to measure the muon beam characteristics.We set up a muon beam monitor(MBM),where scintillating fibers woven in a cross shape were coupled to silicon photomultipliers to measure the spatial profile and timing structure of the extracted muon beam for the COMET.The MBM detector was tested successfully with a proton beamline at the China Spallation Neutron Source and took data with good performance in the commissioning run.The development of the MBM,including its mechanical structure,electronic readout,and beam measurement results,are discussed. 展开更多
关键词 Beam instrumentation Profile monitor Scintillating fiber Silicon photomultipliers
在线阅读 下载PDF
Test system of the front-end readout for an application-specific integrated circuit for the water Cherenkov detector array at the large high-altitude air shower observatory 被引量:5
12
作者 Er-Lei Chen Lei Zhao +4 位作者 Li Yu Jia-Jun Qin Yu Liang Shu-Bin Liu Qi An 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第6期140-149,共10页
The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore ... The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements. 展开更多
关键词 Time and charge measurement photomultiplier tube (PMT) Water CHERENKOV detector ARRAY Inter-integrated CIRCUIT Application-specific integrated CIRCUIT Test system
在线阅读 下载PDF
EQR SiPM with P-on-N diode configuration 被引量:4
13
作者 Jian-Quan Jia Jia-Li Jiang +2 位作者 Kun Liang Ru Yang De-Jun Han 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第8期19-25,共7页
The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a conti... The silicon photomultiplier(SiPM) with epitaxial quenching resistor(EQR) is an emerging and developing technology that has recently attracted the interest from the research community. It has characteristics of a continuous low-resistance cap layer and integrated quenching resisters in epitaxial silicon layer, which makes it possible to increase microcell density or reduce microcell size, thus obtaining large dynamic range and high photon detection efficiency(PDE) simultaneously. Results published show that the EQR SiPM with N-on-P diode configuration had relatively low PDE at peak wavelength of 480 nm as 16%. This paper reported the EQR SiPM with P-on-N diode configuration having active area of 3 × 3 mm^2 and cell density of 10,000/mm^2(total 90,000 pixels). It was characterized with gain of 2E5, dark count rate of 7 MHz, crosstalk of 7%, dynamic range of 85,000 pixels, overall recovery time of 32 ns at room temperature and over-voltage of 3.5 V. The improved PDE at peak wavelength of 420 nm was 30%. 展开更多
关键词 Silicon photomultiplier Epitaxial quenching P-on-N DIODE Characteristics
在线阅读 下载PDF
Design and development of multi-channel front end electronics based on dual-polarity charge-to-digital converter for SiPM detector applications 被引量:5
14
作者 Yu‑Ying Li Chang‑Yu Li Kun Hu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第2期1-12,共12页
With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system ac... With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system achieved by fieldprogrammable gate array-based charge-to-digital converter(FPGA-QDC)technology was built and developed.The FEE consists of an analog board and FPGA board.The analog board incorporates commercial amplifiers,resistors,and capacitors.The FPGA board is composed of a low-cost FPGA.The electronics performance of the FEE was evaluated in terms of noise,linearity,and uniformity.A positron emission tomography(PET)detector with three different readout configurations was designed to validate the readout capability of the FEE for SiPM-based detectors.The PET detector was made of a 15×15 lutetium–yttrium oxyorthosilicate(LYSO)crystal array directly coupled with a SiPM array detector.The experimental results show that FEE can process dual-polarity charge signals from the SiPM detectors.In addition,it shows a good energy resolution for 511-keV gamma photons under the dual-end readout for the LYSO crystal array irradiated by a Na-22 source.Overall,the FEE based on FPGA-QDC shows promise for application in SiPM-based radiation detectors. 展开更多
关键词 Readout electronics Charge measurement Radiation detector Silicon photomultiplier Field-programmable gate array
在线阅读 下载PDF
Design and performance of a high-speed and low-noise preamplifier for SiPM 被引量:5
15
作者 Xi‑Yang Wang Hong‑Yu Zhang +4 位作者 De‑Qing Fang Wan‑Bing He Xiao‑Long Wang Qi‑Bin Zheng Shi‑Ming Zou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第11期93-102,共10页
Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The pre... Considering the R&D for upgrading the K^(0)_(L) andμdetectors in the Belle II experiment using a scintillator and silicon pho-tomultiplier(SiPM),we designed a compact high-speed and low-noise preamplifier.The preamplifier demonstrated a good gain stability,bandwidth of 426 MHz,baseline noise level ofσ≈0.6 mV,dynamic range of up to170 mV of the input signal amplitude,good time resolution of 20 ps,and it can be comprehensively applied to SiPMs.Adopting pole-zero-cancelation in the preamplifier reduces both the rise and fall times of the SiPM signal,which can significantly improve the time resolution and reduce the pile-up when using a large SiPM or an array of SiPMs.Various combinations of the preamplifier and several types of SiPMs demonstrated time resolutions better than 50 ps for most cases;when the number of detected photons was larger than 60,a time resolution of approximately 25 ps was achieved. 展开更多
关键词 Silicon photomultiplier High-speed amplifier Low noise High time resolution
在线阅读 下载PDF
Dark count rate and band to band tunneling optimization for single photon avalanche diode topologies 被引量:2
16
作者 Taha Haddadifam Mohammad Azim Karami 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第6期458-464,共7页
This paper proposes two optimal designs of single photon avalanche diodes(SPADs) minimizing dark count rate(DCR). The first structure is introduced as p^+/pwell/nwell, in which a specific shallow pwell layer is added ... This paper proposes two optimal designs of single photon avalanche diodes(SPADs) minimizing dark count rate(DCR). The first structure is introduced as p^+/pwell/nwell, in which a specific shallow pwell layer is added between p^+and nwell layers to decrease the electric field below a certain threshold. The simulation results show on average 19.7%and 8.5% reduction of p^+/nwell structure’s DCR comparing with similar previous structures in different operational excess bias and temperatures respectively. Moreover, a new structure is introduced as n+/nwell/pwell, in which a specific shallow nwell layer is added between n+and pwell layers to lower the electric field below a certain threshold. The simulation results show on average 29.2% and 5.5% decrement of p^+/nwell structure’s DCR comparing with similar previous structures in different operational excess bias and temperatures respectively. It is shown that in higher excess biases(about 6 volts), the n+/nwell/pwell structure is proper to be integrated as digital silicon photomultiplier(dSiPM) due to low DCR. On the other hand, the p^+/pwell/nwell structure is appropriate to be utilized in dSiPM in high temperatures(above 50?C) due to lower DCR value. 展开更多
关键词 SINGLE-PHOTON AVALANCHE diode digital silicon photomultiplier DARK COUNT rate
原文传递
A hydroxyl radical detection system using gas expansion and fast gating laser-induced fluorescence techniques 被引量:1
17
作者 Hao Chen Renzhi Hu +7 位作者 Pinhua Xie Xingbiao Xing Liuyi Ling Zhiyan Li Fengyang Wang Yihui Wang Jianguo Liu Wenqing Liu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第3期190-200,共11页
An OH radical measurement instrument based on Fluorescence Assay by Gas Expansion(FAGE)has been developed in our laboratory.Ambient air is introduced into a low-pressure fluorescence cell through a pinhole aperture ... An OH radical measurement instrument based on Fluorescence Assay by Gas Expansion(FAGE)has been developed in our laboratory.Ambient air is introduced into a low-pressure fluorescence cell through a pinhole aperture and irradiated by a dye laser at a high repetition rate of 8.5 k Hz.The OH radical is both excited and detected at 308 nm using A-X(0,0)band.To satisfy the high efficiency needs of fluorescence collection and detection,a 4-lens optical system and a self-designed gated photomultiplier(PMT)is used,and gating is actualized by switching the voltage applied on the PMT dynodes.A micro channel photomultiplier(MCP)is also prepared for fluorescence detection.Then the weak signal is accumulated by a photon counter in a specific timing.The OH radical excitation spectrum range in the wavelength of 307.82–308.2 nm is detected and the excited line for OH detection is determined to be Q1(2)line.The calibration of the FAGE system is researched by using simultaneous photolysis of H2O and O2.The minimum detection limit of the instrument using gated PMT is determined to be 9.4×10~5molecules/cm^3,and the sensitivity is 9.5×10^(-7)cps/(OH·cm^(-3)),with a signal-to-noise ratio of 2 and an integration time of 60 sec,while OH detection limit and the detection sensitivity using MCP is calculated to be 1.6×10~5molecules/cm^3and 2.3×10^(-6)cps/(OH·cm^(-3)).The laboratory OH radical measurement is carried out and results show that the proposed system can be used for atmospheric OH radical measurement. 展开更多
关键词 OH radical Laser-induced fluorescence Fluorescence assay by gas expansion photomultiplier Photon counting
原文传递
Database system for managing 20,00020-inch PMTs at JUNO 被引量:1
18
作者 Jun Wang Nikolay Anfimov +16 位作者 Jing-Yuan Guo Yu Gu Hang Hu Min Li Qiu-Mei Ma Alexander Olshevskiy Zhao-Yuan Peng Zhong-Hua Qin Alexander Tietzsch Bjorn Wonsak Wei Wang Zhi-Min Wang Mei-Hang Xu Wan Xie Zheng-Yun You Hai-Qiong Zhang Rong Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第3期10-21,共12页
A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Li... A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Linux+Apache+MySQL+PHP(LAMP)server and focuses on modularization and architecture separation.It covers all the testing stages for the 20-inch photomultiplier tubes(PMTs)at JUNO and provides its users with data storage,analysis,and visualization services.Based on the successful use of the system in the 20-inch PMT testing program,its design approach and construction elements can be extended to other projects. 展开更多
关键词 LAMP photomultiplier tubes Jiangmen underground neutrino observatory Data visualization
在线阅读 下载PDF
Neutron and Ion Beams Emitted from Plasma Focus (112.5 J) Device
19
作者 G.M.EL-ARAGI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第1期1-5,共5页
Preliminary results of recent experiments performed within the Mather-type 112.5 J plasma focus device are presented. The ion beams from the focus device operated with deuterium filling at 1 mbar were registered using... Preliminary results of recent experiments performed within the Mather-type 112.5 J plasma focus device are presented. The ion beams from the focus device operated with deuterium filling at 1 mbar were registered using CR-39 solid state nuclear track detectors (SSNTD) and a Faraday cup detector for time-resolved measurements. The time-resolved neutron emission from the focus region measurements was detected with a photomultiplier tube (IP-28) optically coupled with a plastic scintillator NE 102. 展开更多
关键词 PLASMAS NEUTRON scintillator detectors photomultiplier FARADAY
在线阅读 下载PDF
Preliminary results for the design,fabrication,and performance of a backside-illuminated avalanche drift detector
20
作者 乔赟 梁琨 +1 位作者 陈文飞 韩德俊 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第10期619-625,共7页
The detection of low-level light is a key technology in various experimental scientific studies. As a photon detector, the silicon photomultiplier (SiPM) has gradually become an alternative to the photomultiplier tu... The detection of low-level light is a key technology in various experimental scientific studies. As a photon detector, the silicon photomultiplier (SiPM) has gradually become an alternative to the photomultiplier tube (PMT) in many applications in high-energy physics, astroparticle physics, and medical imaging because of its high photon detection efficiency (PDE), good resolution for single-photon detection, insensitivity to magnetic field, low operating voltage, compactness, and low cost. However, primarily because of the geometric fill factor, the PDE of most SiPMs is not very high; in particular, for those SiPMs with a high density of micro cells, the effective area is small, and the bandwidth of the light response is narrow. As a building block of the SiPM, the concept of the backside-illuminated avalanche drift detector (ADD) was first proposed by the Max Planck Institute of Germany eight years ago; the ADD is promising to have high PDE over the full energy range of optical photons, even ultraviolet light and X-ray light, and because the avalanche multiplication region is very small, the ADD is beneficial for the fabrication of large-area SiPMs. However, because of difficulties in design and fabrication, no significant progress had been made, and the concept had not yet been verified. In this paper, preliminary results in the design, fabrication, and performance of a backside-illuminated ADD are reported; the difficulties in and limitations to the backside-illuminated ADD are analyzed. 展开更多
关键词 avalanche drift detector silicon photomultiplier photon detection efficiency photon detector
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部