PCBs pollutants are measured on tidal-flat sediments of Yangtze estuary by a high resolution capillary column gas chromatography ( HP6890 ) equipped with an 63Ni electron capture detector ( ECD ). The concentration te...PCBs pollutants are measured on tidal-flat sediments of Yangtze estuary by a high resolution capillary column gas chromatography ( HP6890 ) equipped with an 63Ni electron capture detector ( ECD ). The concentration tendency of PCBs is Phragmites zone > Scirpus zone > bare mudflats. There are linear relations between PCBs and TOC and > 63μm grain size percentage ( in volume ). The low chlorinated congeners may be more important than the high chlorinated congeners in this area. PCBs prefer to accumulate in the sediments near sewage outlets and Phragmites zone. The sediments’ PCBs pollution ( 10.7 ~ 28.6 ng/g, dry weight ) in the Yangtze estuary tidal-flat is less serious than that of the most of other areas in the world .But the detected ratio is 100%, even the Jiuduansha shoal has detected PCBs, so much attention should be paid to this area for PCBs.展开更多
Three extraction techniques have been recently used for the quantitative extraction of semi-volatile organic pollutants in sediments, i.e. accelerated solvent extraction (ASE), microwave assisted extraction (MAE) ...Three extraction techniques have been recently used for the quantitative extraction of semi-volatile organic pollutants in sediments, i.e. accelerated solvent extraction (ASE), microwave assisted extraction (MAE) and ultrasonic assisted extraction (UAE). However, their extraction efficiencies have rarely been quantitatively compared using rigorous mathematical methods. In this paper, one-way analysis of variance (ANOVA) was employed to evaluate the performance of ASE, MAE and UAE in the overall extraction of PCBs, DDTs and HCHs by analysis of their recoveries from the Standard Reference Material IAEA-417, a sediment sample certified by many international laboratories. Conclusions were drawn at a significance level of P〈 0.05. No significant differences were found among the mean values for method recoveries using ASE, MAE and UAE. The mean values for real recoveries using ASE and MAE were nearly identical, but the real recovery using UAE was much lower. The concentrations of all PCBs, DDTs and HCHs except for CB52 and o,p'-DDT using UAE were the lowest. Comparing the results obtained using ASE with MAE, the concentrations of CB28, CB52, CB138, ct-HCH, [3-HCH, p,p'-DDE and p,p'-DDD were nearly identical, while the concentrations of other compounds were significantly different. Based on the low recoveries, it was concluded that UAE is a relatively inefficient extraction method, while ASE and MAE are equivalent methods. Taking into consideration the relative standard deviation (RSD) values, solvent volume, extraction time, and purchasing costs of the apparatus, MAE was considered superior to ASE for extraction of PCBs, DDTs and HCHs.展开更多
Few studies have dealt on the evaluation of volatilization and decomposition reactions of dioxins from sediment by oxygen free pyrolysis. In this study, the performance of pyrolysis on the removal of dioxins from sedi...Few studies have dealt on the evaluation of volatilization and decomposition reactions of dioxins from sediment by oxygen free pyrolysis. In this study, the performance of pyrolysis on the removal of dioxins from sediment was investigated. Dioxin concentrations of the raw sediment and the solid residues after pyrolysis were analyzed at different conditions. Results showed a removal efficiency of 99.9999% for total dioxins at 800℃ and retention time of 30 min. All the polychlorinated dibenzo-furans (PCDFs) have been removed and were not formed in the solid residues at the retention time range of 30-90 min at 800℃. Close to 100% removal of polychlorinated dibenzo-p-dioxins (PCDDs) was also achieved. Only trace PCDDs were detected in the solid yields at a retention time of 60 min. The highest removal efficiency of polychlorinated biphenyls (PCBs) was more than 99.9994% at a retention time of 30 min. During cooling period following pyrolysis, however, the concentration of total dioxins in solid residues increased 130 times as compared to that of the raw sediment under air atmosphere. This confirmed that some complex reactions do occur to form PCDD/Fs and PCBs from 800 to 400℃ in the presence of oxygen. Oxygen-free atmosphere therefore can prevent formation of dioxin during thermal process thus generating clean solid residues.展开更多
基金supported by the National Natural Science Fund of China (No.49871068 and No.40131020)
文摘PCBs pollutants are measured on tidal-flat sediments of Yangtze estuary by a high resolution capillary column gas chromatography ( HP6890 ) equipped with an 63Ni electron capture detector ( ECD ). The concentration tendency of PCBs is Phragmites zone > Scirpus zone > bare mudflats. There are linear relations between PCBs and TOC and > 63μm grain size percentage ( in volume ). The low chlorinated congeners may be more important than the high chlorinated congeners in this area. PCBs prefer to accumulate in the sediments near sewage outlets and Phragmites zone. The sediments’ PCBs pollution ( 10.7 ~ 28.6 ng/g, dry weight ) in the Yangtze estuary tidal-flat is less serious than that of the most of other areas in the world .But the detected ratio is 100%, even the Jiuduansha shoal has detected PCBs, so much attention should be paid to this area for PCBs.
基金Supported by the National High Technology Research and Development Program of China (No. 2007AA09Z126)the Marine Science Foundation for Young Scholars of SOA (No. 2011519)Marine Commonwealth Scientific Support Fund of SOA (Nos. 201005034, 201105013)
文摘Three extraction techniques have been recently used for the quantitative extraction of semi-volatile organic pollutants in sediments, i.e. accelerated solvent extraction (ASE), microwave assisted extraction (MAE) and ultrasonic assisted extraction (UAE). However, their extraction efficiencies have rarely been quantitatively compared using rigorous mathematical methods. In this paper, one-way analysis of variance (ANOVA) was employed to evaluate the performance of ASE, MAE and UAE in the overall extraction of PCBs, DDTs and HCHs by analysis of their recoveries from the Standard Reference Material IAEA-417, a sediment sample certified by many international laboratories. Conclusions were drawn at a significance level of P〈 0.05. No significant differences were found among the mean values for method recoveries using ASE, MAE and UAE. The mean values for real recoveries using ASE and MAE were nearly identical, but the real recovery using UAE was much lower. The concentrations of all PCBs, DDTs and HCHs except for CB52 and o,p'-DDT using UAE were the lowest. Comparing the results obtained using ASE with MAE, the concentrations of CB28, CB52, CB138, ct-HCH, [3-HCH, p,p'-DDE and p,p'-DDD were nearly identical, while the concentrations of other compounds were significantly different. Based on the low recoveries, it was concluded that UAE is a relatively inefficient extraction method, while ASE and MAE are equivalent methods. Taking into consideration the relative standard deviation (RSD) values, solvent volume, extraction time, and purchasing costs of the apparatus, MAE was considered superior to ASE for extraction of PCBs, DDTs and HCHs.
基金The New Energy and Industrial Technology Development Organization of Japan
文摘Few studies have dealt on the evaluation of volatilization and decomposition reactions of dioxins from sediment by oxygen free pyrolysis. In this study, the performance of pyrolysis on the removal of dioxins from sediment was investigated. Dioxin concentrations of the raw sediment and the solid residues after pyrolysis were analyzed at different conditions. Results showed a removal efficiency of 99.9999% for total dioxins at 800℃ and retention time of 30 min. All the polychlorinated dibenzo-furans (PCDFs) have been removed and were not formed in the solid residues at the retention time range of 30-90 min at 800℃. Close to 100% removal of polychlorinated dibenzo-p-dioxins (PCDDs) was also achieved. Only trace PCDDs were detected in the solid yields at a retention time of 60 min. The highest removal efficiency of polychlorinated biphenyls (PCBs) was more than 99.9994% at a retention time of 30 min. During cooling period following pyrolysis, however, the concentration of total dioxins in solid residues increased 130 times as compared to that of the raw sediment under air atmosphere. This confirmed that some complex reactions do occur to form PCDD/Fs and PCBs from 800 to 400℃ in the presence of oxygen. Oxygen-free atmosphere therefore can prevent formation of dioxin during thermal process thus generating clean solid residues.