Objective The lack of clarity regarding the application performance of a hybrid operating room(HOR)and the uncertainty of surgical scheduling often lead to its inefficient application.This study aimed to review the cl...Objective The lack of clarity regarding the application performance of a hybrid operating room(HOR)and the uncertainty of surgical scheduling often lead to its inefficient application.This study aimed to review the clinical application of our neurosurgical HOR and propose a scale to score cases clearly.Methods We reviewed the operating procedures and duration of stay in 1865 HOR cases.The actual procedures of each case were summarized into 5 application types,and numerical assignment was used to distinguish the dependence of each type on our HOR:surgical procedures combined with interventional procedures(4 points,the highest dependence),surgical procedures combined with imaging procedures(3 points),interventional procedures(2 points),imaging procedures(1 point),and surgical procedures(0 points,the lowest dependence).Results A novel scale that could score 1865 cases into those 5 grades was developed.The percentages by grade were as follows:4 points,4.24%;3 points,4.88%;2 points,20.75%;1 point,69.38%;and 0 points,0.75%.The cumulative usage time was 4241.9 h,the duration of which was as follows:4 points,16.17%;3 points,15.50%;2 points,31.32%;1 point,35.62%;and 0 points,1.39%.Conclusions The HOR serves as a multifunctional room to treat neurosurgical diseases.The scale helps to quickly prioritize cases that rely more on HOR,providing guidelines for surgical scheduling.Although our HOR is unsuitable for emergency cases,it clearly shows the application performance of our HOR to provide a reference for promoting its efficient application.展开更多
The recently developed European flaw assessment procedure, structural integrity assessment procedure(SiNTAP) is applied to assessment for welded joints of the API 5L X65 pipeline steel with an assumed embedded flaw ...The recently developed European flaw assessment procedure, structural integrity assessment procedure(SiNTAP) is applied to assessment for welded joints of the API 5L X65 pipeline steel with an assumed embedded flaw and surface flaw at the weld toe. As one of the basic input data, fracture toughness crack tip opening displacement (CTOD) tests are conducted at 0℃ and performed according to the requirements of the standard of BS7448. For the heat affected zone (HAZ) specimens, the microstructure observation is performed to insure that the tip of the crack is located in the coarse grain zone. The result explains the dispersity of the test values. In structural integrity assessment procedure-fracture assessment diagram(SINTAP FAD) method, the failure curves of welded joints at level 1 and 3 are derived from the tensile test results. The results of the assessment show that all assessment points are located within the failure lines of analysis level 1 and 3. So the welded joint of the pipeline is safe. This study laid the foundation of application of SINTAP to pipeline structure assessment.展开更多
基金supported by the Technology Innovation Special Major Project of Hubei Province(grant number 2022BCA003).
文摘Objective The lack of clarity regarding the application performance of a hybrid operating room(HOR)and the uncertainty of surgical scheduling often lead to its inefficient application.This study aimed to review the clinical application of our neurosurgical HOR and propose a scale to score cases clearly.Methods We reviewed the operating procedures and duration of stay in 1865 HOR cases.The actual procedures of each case were summarized into 5 application types,and numerical assignment was used to distinguish the dependence of each type on our HOR:surgical procedures combined with interventional procedures(4 points,the highest dependence),surgical procedures combined with imaging procedures(3 points),interventional procedures(2 points),imaging procedures(1 point),and surgical procedures(0 points,the lowest dependence).Results A novel scale that could score 1865 cases into those 5 grades was developed.The percentages by grade were as follows:4 points,4.24%;3 points,4.88%;2 points,20.75%;1 point,69.38%;and 0 points,0.75%.The cumulative usage time was 4241.9 h,the duration of which was as follows:4 points,16.17%;3 points,15.50%;2 points,31.32%;1 point,35.62%;and 0 points,1.39%.Conclusions The HOR serves as a multifunctional room to treat neurosurgical diseases.The scale helps to quickly prioritize cases that rely more on HOR,providing guidelines for surgical scheduling.Although our HOR is unsuitable for emergency cases,it clearly shows the application performance of our HOR to provide a reference for promoting its efficient application.
基金This project is supported by National Natural Science Foundation of China(No.50375109).
文摘The recently developed European flaw assessment procedure, structural integrity assessment procedure(SiNTAP) is applied to assessment for welded joints of the API 5L X65 pipeline steel with an assumed embedded flaw and surface flaw at the weld toe. As one of the basic input data, fracture toughness crack tip opening displacement (CTOD) tests are conducted at 0℃ and performed according to the requirements of the standard of BS7448. For the heat affected zone (HAZ) specimens, the microstructure observation is performed to insure that the tip of the crack is located in the coarse grain zone. The result explains the dispersity of the test values. In structural integrity assessment procedure-fracture assessment diagram(SINTAP FAD) method, the failure curves of welded joints at level 1 and 3 are derived from the tensile test results. The results of the assessment show that all assessment points are located within the failure lines of analysis level 1 and 3. So the welded joint of the pipeline is safe. This study laid the foundation of application of SINTAP to pipeline structure assessment.