期刊文献+
共找到327,926篇文章
< 1 2 250 >
每页显示 20 50 100
Development of an on-line measurement system for water-soluble organic matter in PM_(2.5) and its application in China 被引量:5
1
作者 Huiying Li Xiaofeng Huang +3 位作者 Liming Cao Yuhong Zhai Liwu Zeng Lingyan He 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第7期33-40,共8页
Water-soluble organic matter(WSOM) represents a critical fraction of fine particles(PM2.5)in the air, but its changing behaviors and formation mechanisms are not well understood yet, partly due to the lack of fast... Water-soluble organic matter(WSOM) represents a critical fraction of fine particles(PM2.5)in the air, but its changing behaviors and formation mechanisms are not well understood yet, partly due to the lack of fast techniques for the ambient measurements. In this study,a novel system for the on-line measurement of water-soluble components in PM2.5, the particle-into-liquid sampler(PILS)–Nebulizer–aerosol chemical speciation monitor(ACSM), was developed by combining a PILS, a nebulizer, and an ACSM. High time resolution concentrations of WSOM, sulfate, nitrate, ammonium, and chloride, as well as mass spectra, can be obtained with satisfied quality control results. The system was firstly applied in China for field measurement of WSOM. The mass spectrum of WSOM was found to resemble that of oxygenated organic aerosol, and WSOM agreed well with secondary inorganic ions. All evidence collected in the field campaign demonstrated that WSOM could be a good surrogate of secondary organic aerosol(SOA). The PILS–Nebulizer–ACSM system can thus be a useful tool for intensive study of WSOM and SOA in PM2.5. 展开更多
关键词 PM2.5 Water-soluble organic matter Secondary organic matter on-line measurement Mass spectrum
原文传递
On-Line Measurement of the Chemical Oxygen Demand in Wastewater in a Pulp and Paper Mill Using Near Infrared Spectroscopy 被引量:5
2
作者 John Dahlbacka Josefina Nystrom +2 位作者 Torgny Mossing Paul Geladi Tom Lillhonga 《Spectral Analysis Review》 2014年第4期19-25,共7页
Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts... Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy. 展开更多
关键词 Chemical Oxygen Demand (COD) Industrial Wastewater Near Infrared Spectroscopy (NIR) Multivariate Calibration on-line measurement
在线阅读 下载PDF
On-line Measurement of Water-Soluble Ions in Ambient Particles 被引量:5
3
作者 温天雪 王跃思 +1 位作者 张士昱 刘广仁 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2006年第4期586-592,共7页
Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-lin... Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-line the concentrations of water-soluble ions in ambient particles. Here, the general scheme of RCFP-IC is described and its basic performance is tested. The detection limit of RCFP-IC for SO4^2-, NO3^-, NO2^-, Cl^- and F- is below 0.3μg m^-3. The collection efficiency of RCFP-IC increases rapidly with increasing sized particles. For particles larger than 300 nm, the collection efficiency approaches 100%. The precision of RCFP-IC is more than 90% over 28 repetitions. The response of RCFP-IC is very sensitive and no obvious cross-pollution is found during measurement. A comparison of RCFP-IC with an integrated filter measurement indicates that the measurement of RCFP-IC is comparable in both laboratory experiments and field observations. The results of the field experiment prove that RCFP-IC is an effective on-line monitoring system and is helpful in source apportionment and pollution episode monitoring. 展开更多
关键词 RCFP-IC water-soluble ions on-line basic performance field observation
在线阅读 下载PDF
A METHOD OF ON-LINE MEASUREMENT FOR THE FREQUENCY RESPONSE AND IMPULSE RESPONSE FUNCTIONS OF MULTIVARIATE SYSTEM
4
作者 汪凤泉 韩晓林 吴慧新 《Journal of Southeast University(English Edition)》 EI CAS 1993年第1期95-101,共7页
In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capa... In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capacity of therestraint to the identification error caused by the non-random D.C.drift of the mul-ti-input excitation with the ORRS in the multivariate system is also discussed.Thevalidity of the method described in this paper is proved by the modelling tests of themulti-plate rotor system. 展开更多
关键词 on-line IDENTIFICATION multi-point EXCITATION ORTHOGONAL reciprocal repeated SEQUENCE VIBRATION measurement
在线阅读 下载PDF
On-line measurement of electrical variables of the transducer during ultrasonic welding and cutting
5
作者 闫久春 刘井权 杨士勤 《China Welding》 EI CAS 2002年第2期133-137,共5页
A measurement system for high power electrical variables with ultrasonic frequency was established. It can measure the effective values of the voltage and the current, the active power, the phase difference of voltage... A measurement system for high power electrical variables with ultrasonic frequency was established. It can measure the effective values of the voltage and the current, the active power, the phase difference of voltage and current, the frequency of the transducer during ultrasonic welding and cutting. In sampling circuits of the system, the measured current is sensed by using a no capacitance and no inductance precision resistor and is treated with a difference amplifier, the measured voltage is processed by using a proportional amplifier. For achieving good amplitude frequency characteristics and rapid measurement of high frequency signals, the resistors, capacitors and amplifiers used in the system are rationally selected. Calibrating experiments show that relative errors are less than 1% for voltage and current effective values and less than 2.5% for active power, and absolute errors are ±1 Hz for frequency and ±1.7° for phase difference of voltage and current in the range of 17~23 kHz . 展开更多
关键词 ultrasonic welding ultrasonic cutting on line measurement electrical variables
在线阅读 下载PDF
Novel Optical Fiber Gas Sensor for On-line Measurement of Methane
6
作者 WANGShu-tao CHERen-sheng +1 位作者 LIUJin WANGYu-tian 《Semiconductor Photonics and Technology》 CAS 2004年第2期141-144,共4页
Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measu... Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measurement is presented in this paper. In order to eliminate the noise, the ratio of the fundamental and second-harmonic signals is used. The mathematical model of gas concentration harmonic measurement is built up.The detection result of methane concentration is also shown. Experiments have proved a sensitivity of 28×10-6. 展开更多
关键词 Gas sensor METHANE MODULATION Harmonic measurement
在线阅读 下载PDF
On-Line Measurement Method for Diameter and Roundness Error of Balls 被引量:6
7
作者 Yindi Cai Bo Xie +1 位作者 Siying Ling Kuang-Chao Fan 《Nanomanufacturing and Metrology》 2020年第3期218-227,共10页
This paper presents an on-line measurement method for the diameter and roundness error of balls.An easy-installation rotary scanning system,which integrates the principles of the diameter and the roundness measurement... This paper presents an on-line measurement method for the diameter and roundness error of balls.An easy-installation rotary scanning system,which integrates the principles of the diameter and the roundness measurements,is constructed.The rotary scanning system consists of a rotary stage,a linear stage,and two sensors with a什at probe.Two sensors are initially installed on the linear stage and contact each other.The outputs of two sensors are reset to zero at first.The ball is then mounted on the rotary stage and positioned between two flat probes.The variations of the diameter and the roundness error of the ball at each angular position can be directly recorded by two sensors when the ball is rotated by the rotary stage.Substituting the outputs of two sensors into the proposed mathematical models,the diameter and roundness error can be evaluated.The effects of the alignment error induced by the spindle error of the rotary stage and the titling error and the eccentric error of the ball on the measurement accuracy can be self-separated in the proposed on-line measurement method.A series of experiments are carried out to verify the effectiveness and the capability of the proposed on-line measurement method and the designed rotary scanning system.The designed system is easy to construct both in the laboratory environment and the factory field. 展开更多
关键词 on-line measurement DIAMETER Roundness error Alignment error
原文传递
Development of an automatic measurement system using atmospheric pressure photoionization ultrahigh-resolution mass spectrometry and application for on-line analysis of particulate matter
8
作者 Yayuan Dong Ranran Liu +4 位作者 Ling Xie Xiaole Pan Yele Sun Lin Wu ZifaWang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2024年第4期516-530,共15页
On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real tim... On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real time.Here we describe the development and application of an automatic measurement system that incorporates PM_(2.5)sampling,thermal desorption,atmospheric pressure photoionization,and UHRMS analysis.Molecular formulas of detected organic compounds were deducted from the accurate(±10 ppm)molecular weights obtained at a mass resolution of 100,000,allowing the identification of small organic compounds in PM_(2.5).Detection efficiencies of 28 standard compounds were determined and we found a high sensitivity and selectivity towards organic amines with limits of detection below 10 pg.As a proof of principle,PM_(2.5)samples collected off-line in winter in the urban area of Beijing were analyzed using the Ionization Module and HRMS of the system.The automatic system was then applied to conduct on-line measurements during the summer time at a time resolution of 2 hr.The detected organic compounds comprised mainly CHON and CHN compounds below 350 m/z.Pronounced seasonal variations in elemental composition were observed with shorter carbon backbones and higher O/C ratios in summer than that in winter.This result is consistent with stronger photochemical reactions and thus a higher oxidation state of organics in summer.Diurnal variation in signal intensity of each formula provides crucial information to reveal its source and formation pathway.In summary,the automatic measurement system serves as an important tool for the on-line characterization and identification of organic species in PM_(2.5). 展开更多
关键词 PM_(2.5) Chemical composition on-line measurement technique High resolution mass spectrometry
原文传递
A review of the standardized measurement of the characteristics of graphene-based materials
9
作者 Zhang Donghui Li Wan +2 位作者 Ou Bingxian Wang Liangwang Ge Guanglu 《新型炭材料(中英文)》 北大核心 2026年第1期91-108,共18页
Standardization is necessary for the early industrialization of the new materials and technology.It is achieved by having agreed practices for the measurement of properties and other characteristics.The promising use ... Standardization is necessary for the early industrialization of the new materials and technology.It is achieved by having agreed practices for the measurement of properties and other characteristics.The promising use of graphene-based materials in fields like electronics,energy,and composites has resulted in standards for their nomenclature,the measurement of key characteristics,and their specification,etc.Among these,standards for measuring the key characteristics are crucial.The critical parameters are the number of layers,the type and concentration of defects and functional groups,elemental composition,sheet resistance,and carrier mobility.Standards for characterizing these have been analyzed by the International Organization for Standardization Technical Committee in ISO/TC229 and the International Electrotechnical Commission Technical Committee in IEC/TC113.These give details of applicable or preferred samples,the fundamental principles of the techniques,specific precautions,and points for attention in the relevant standards.The pivotal role of the ISO/TC229 and IEC/TC113 standards is considered and challenges and future trends are outlined. 展开更多
关键词 Nanotechnology Graphene-based materials measurement standards Critical characteristics Quality control
在线阅读 下载PDF
Comparison of three different instruments for vault measurements after implantable collamer lens implantation
10
作者 Bo-Liang Li Ming-Rui Cheng +6 位作者 Wei-Teng Chang Ya-Di Lei Guang-Han Xu Ming-Wei Li Zhi-Wei Mao Xun Chen Xiao-Ying Wang 《International Journal of Ophthalmology(English edition)》 2026年第3期475-482,共8页
AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)follow... AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)following implantable collamer lens(ICL)V4c implantation.METHODS:Vault measurements were acquired using three modalities:Pentacam,CASIA II AS-OCT,and UBM.Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices.The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient,intraclass correlation coefficient(ICC),and Bland-Altman plots.RESULTS:This retrospective study enrolled 210 myopic eyes of 210 patients(158 women and 52 men)who underwent ICL implantation:108 eyes had a myopic ICL V4c implanted,and 102 eyes had a toric ICL V4c implanted.The mean vault values measured by Pentacam,CASIA II,and UBM were 452.64±204.20μm,538.57±203.54μm,and 560.95±227.54μm,respectively,with statistically significant differences among the three groups(P<0.05).Pearson correlation analysis showed strong positive correlations between vault values measured by different instruments(all P<0.001).ICC results indicated good consistency among the three measurement modalities(all P<0.001).Stratified analysis revealed that when the vault value was≤250μm,the correlation and consistency of measurements across the three instruments were lower than those in the medium and high vault subgroups.CONCLUSION:Vault values measured by Pentacam are lower than those obtained by CASIA II and UBM,with UBM yielding the highest mean vault values.Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency.Pentacam and CASIA II demonstrate the highest consistency in vault measurement.Notably,when the vault value is≤250μm,the consistency between Pentacam and the other two instruments decreases significantly. 展开更多
关键词 implantable collamer lens vault measurement scheimpflug tomography anterior segment optical coherence tomography ultrasound biomicroscopy measurement consistency
原文传递
Exploring recent breakthroughs in robotic biomechanical and electrophysiological measurement tools
11
作者 Hui-Yao Shi Si Tang +3 位作者 Jia-Lin Shi Peng Yu Chan-Min Su Lian-Qing Liu 《Biomedical Engineering Communications》 2026年第1期35-47,共13页
Single-cell biomechanics and electrophysiology measuring tools have transformed biological research over the last few decades,which enabling a comprehensive and nuanced understanding of cellular behavior and function.... Single-cell biomechanics and electrophysiology measuring tools have transformed biological research over the last few decades,which enabling a comprehensive and nuanced understanding of cellular behavior and function.Despite their high-quality information content,these single-cell measuring techniques suffer from laborious manual processing by highly skilled workers and extremely low throughput(tens of cells per day).Recently,numerous researchers have automated the measurement of cell mechanical and electrical signals through robotic localization and control processes.While these efforts have demonstrated promising progress,critical challenges persist,including human dependency,learning complexity,in-situ measurement,and multidimensional signal acquisition.To identify key limitations and highlight emerging opportunities for innovation,in this review,we comprehensively summarize the key steps of robotic technologies in single-cell biomechanics and electrophysiology.We also discussed the prospects and challenges of robotics and automation in biological research.By bridging gaps between engineering,biology,and data science,this work aims to stimulate interdisciplinary research and accelerate the translation of robotic single-cell technologies into practical applications in the life sciences and medical fields. 展开更多
关键词 BIOMECHANICS ELECTROPHYSIOLOGY micro-nano manipulation automated cell measurement ROBOTICS
在线阅读 下载PDF
Development of laser absorption technique for temperature measurements and CO_(2)dissociation studies over 3000-6000 K
12
作者 Tielou LIU Dong HE +5 位作者 Zheng QU Renjie LI Fei LI Juchun DING Ting SI Xisheng LUO 《Science China(Technological Sciences)》 2026年第2期68-80,共13页
Accurate temperature measurement is a crucial step in predicting and managing the aerodynamic heating during Mars entry and Earth reentry.These processes often occur at extremely high temperatures and pose challenges ... Accurate temperature measurement is a crucial step in predicting and managing the aerodynamic heating during Mars entry and Earth reentry.These processes often occur at extremely high temperatures and pose challenges for quantitative measurements.A 1-μs time-resolved laser absorption technique was developed for simultaneous and time-dependent temperature and CO-concentration measurements over 3000-6000 K by adopting the P(0,21)and P(2,15)lines.To achieve quantitative measurement,the line strengths and Ar-broadening parameters were calibrated within 3030-5980 K.A“W”-shaped path-amplified strategy was used to increase the absorption features of the two lines during the calibration process.Validation experiments were conducted at 3040-5970 K to verify the accuracy of the technique.The new technique was then applied for simultaneous and time-resolved temperature and CO-concentration measurements during the CO_(2)dissociation process to further demonstrate the feasibility of the developed technique.The temperature-dependent CO_(2)absorption cross-sections at line centers of the two lines were calibrated within 2040-5870 K.The CO_(2)absorption interferences were quantified and subtracted from the measured laser absorbances.The measured results(referring to temperature and CO concentration)were generally consistent with the predictions from the kinetics mechanisms in the literature,highlighting the applicability of the developed technique for temperature measurements and CO_(2)dissociation studies within the investigated temperature range. 展开更多
关键词 TDLAS high-temperature measurement shock tube CO_(2)dissociation
原文传递
Wall-shear stress measurement via oil-film interferometry being enhanced by quasi-bivariate variational mode decomposition
13
作者 Yi ZHANG Chong PAN +3 位作者 Chunpeng LI Hao LIN Hui GUO Jinjun WANG 《Science China(Technological Sciences)》 2026年第2期1-18,共18页
Characterized by high accuracy and operational simplicity,oil-film interferometry(OFI)has served as an effective wall-shear stress(WSS)measurement technique over the past decades.It utilizes the monochromatic light in... Characterized by high accuracy and operational simplicity,oil-film interferometry(OFI)has served as an effective wall-shear stress(WSS)measurement technique over the past decades.It utilizes the monochromatic light interference principle to measure the temporal variation of oil-film thickness caused by WSS,and calculates time-averaged WSS based on the variation of interference fringe width.However,small-scale noise,which is caused by defects on the target surface,ambient dust,and local oil-film non-uniformity,contaminates the interference fringe patterns and directly increases the measurement uncertainty.One practical way is to apply denoising methods to improve the accuracy of identifying the centroids of fringes.In the present study,quasi-bivariate variational mode decomposition(QBVMD)is proposed as a self-adaptive denoising method to remove small-scale noise.Since no characteristic information of fringe patterns is required in the QBVMD-based denoising method,it has higher accuracy and lower uncertainty than the conventional OFI denoising methods,which need to pre-set the mask signal or the bandpass frequency,i.e.,cross-correlation or spectral filtering.Thus,it facilitates the automatic identification of time-varying inhomogeneous fringes.Two sets of experiments,i.e.,WSS measurement on either a canonical flat-plate turbulent boundary layer(TBL)or a TBL perturbed by micro vortex generators(MVG),were conducted to validate the applicability of this QBVMD-OFI method.The former experiment shows that the accuracy of QBVMD-OFI is equivalent to near-wall high-resolution particle image velocimetry,and is considerably higher than that of a dual hot-film sensor.As for the latter,QBVMD-OFI provides sufficient spatial resolution to resolve fine WSS structures generated by MVG. 展开更多
关键词 wall-shear stress measurement oil-film interferometry turbulent boundary layer micro vortex generator
原文传递
Advances and Prospects in Body-Size Measurement of Sheep:From 2D Vision to 3D Reconstruction and 2D-3D Fusion
14
作者 DAI Weijiao LIANG Yudongchen +5 位作者 ZHOU Yong YAO Chao ZHANG Cheng SONG Yongjian LI Guoliang TIAN Fang 《智慧农业(中英文)》 2026年第1期120-147,共28页
[Significance]In alignment with the national germplasm security strategy,current research efforts are accelerating the adoption of precision breeding in sheep.Within the whole-genome selection,accurate phenotyping of ... [Significance]In alignment with the national germplasm security strategy,current research efforts are accelerating the adoption of precision breeding in sheep.Within the whole-genome selection,accurate phenotyping of body morphometrics is critical for assessing growth performance and breeding value.Traditional manual measurements are inefficient,prone to human error,and may cause stress to sheep,limiting their suitability for precision sheep management.By summarizing the applications of sheep body size measurement technologies and analyzing their development directions,this paper provides theoretical references and practical guidance for the research and application of non contact sheep body size measurement.[Progress]This review synthesizes progress across three principal methodological paradigms:two-dimensional(2D)image-based techniques,three-dimensional(3D)point cloud-based approaches,and integrated 2D-3D fusion systems.2D methods,employing either handcrafted geometric features or deep learning-based keypoint detector algorithms,are cost-effective and operationally simple but sensitive to variation in imaging conditions and unable to capture critical circumference metrics.3D point-cloud approaches enable precise reconstruction of full animal morphology,supporting comprehensive body-size acquisition with higher accuracy,yet face challenges including high hardware costs,complex data workflows,and sensitivity to posture variability.Hybrid 2D-3D fusion systems combine semantic richness from RGB imagery with geometric completeness from point clouds.Having been effectively validated in other livestock specise,e.g.,cattle and pigs,these fusion systems have demonstrated excellent performance,providing important technical references and practical insights for sheep body size measurement.[Conclusions and Prospects]Firstly,future research should focus on constructing large-scale,high-quality datasets for sheep body size measurement that encompass diverse breeds,growth stages,and environmental conditions,thereby enhancing model robustness and generalization.Secondly,the development of lightweight artificial intelligence models is essential.Techniques such as model compression,quantization,and algorithmic optimization can substantially reduce computational complexity and storage requirements,facilitating deployment in resource-constrained environments.Thirdly,the 3D point cloud processing pipeline should be streamlined to improve the efficiency of data acquisition,filtering,registration,and segmentation,while promoting the integration of low-cost,high-resilience vision systems into practical farming scenarios.Fourthly,specific emphasis should be placed on improving the accuracy of curved-dimensional measurements,such as chest circumference,abdominal circumference,and shank circumference,through advances in pose standardization,refined 3D segmentation strategies,and multimodal data fusion.Finally,the cross-fertilization of sheep body size measurement technologies with analogous methods for other livestock species offers a promising pathway for mutual learning and collaborative innovation,accelerating the industrialization of automated sheep morphometric systems and supporting the development of intelligent,data-driven pasture management practices. 展开更多
关键词 smart breeding computer vision image recognition three-dimensional reconstruction 2D-3D body measurement
在线阅读 下载PDF
Integrated N_(2)-Ar measurements of trace extraterrestrial samples
15
作者 Fei Su XuHang Zhang +5 位作者 ChuanTong Zhang YouJuan Li ZiHeng Liu JianNan Li HeJiu Hui HuaiYu He 《Earth and Planetary Physics》 2026年第1期22-29,共8页
As one of the major volatile components in extraterrestrial materials,nitrogen(N_(2))isotopes serve not only as tracers for the formation and evolution of the solar system,but also play a critical role in assessing pl... As one of the major volatile components in extraterrestrial materials,nitrogen(N_(2))isotopes serve not only as tracers for the formation and evolution of the solar system,but also play a critical role in assessing planetary habitability and the search for extraterrestrial life.The integrated measurement of N_(2)and argon(Ar)isotopes by using noble gas mass spectrometry represents a state-of-the-art technique for such investigations.To support the growing demands of planetary science research in China,we have developed a high-efficiency,high-precision method for the integrated analysis of N_(2)and Ar isotopes.This was achieved by enhancing gas extraction and purification systems and integrating them with a static noble gas mass spectrometer.This method enables integrated N_(2)-Ar isotope measurements on submilligram samples,significantly improving sample utilization and reducing the impact of sample heterogeneity on volatile analysis.The system integrates CO_(2)laser heating,a modular two-stage Zr-Al getter pump,and a CuO furnace-based purification process,effectively reducing background levels(N_(2)blank as low as 0.35×10^(−6)cubic centimeters at standard temperature and pressure[ccSTP]).Analytical precision is ensured through calibration with atmospheric air and CO corrections.To validate the reliability of the method,we performed N_(2)-Ar isotope analyses on the Allende carbonaceous chondrite,one of the most extensively studied meteorites internationally.The measured N_(2)concentrations range from 19.2 to 29.8 ppm,withδ15N values between−44.8‰and−33.0‰.Concentrations of 40Ar,36Ar,and 38Ar are(12.5-21.1)×10^(−6)ccSTP/g,(90.9-150.3)×10^(−9)ccSTP/g,and(19.2-30.7)×10^(−9)ccSTP/g,respectively.These values correspond to cosmic-ray exposure ages of 4.5-5.7 Ma,consistent with previous reports.Step-heating experiments further reveal distinct release patterns of N and Ar isotopes,as well as their associations with specific mineral phases in the meteorite.In summary,the combined N_(2)-Ar isotopic system offers significant advantages for tracing volatile sources in extraterrestrial materials and will provide essential analytical support for upcoming Chinese planetary missions,such as Tianwen-2. 展开更多
关键词 integrated N_(2)-Ar measurement noble gas mass spectrometer extraterrestrial samples
在线阅读 下载PDF
Suppression of Dry-Coupled Rubber Layer Interference in Ultrasonic Thickness Measurement:A Comparative Study of Empirical Mode Decomposition Variants
16
作者 Weichen Wang Shaofeng Wang +4 位作者 Wenjing Liu Luncai Zhou Erqing Zhang Ting Gao Grigory Petrishin 《Structural Durability & Health Monitoring》 2026年第1期302-316,共15页
In dry-coupled ultrasonic thickness measurement,thick rubber layers introduce high-amplitude parasitic echoes that obscure defect signals and degrade thickness accuracy.Existing methods struggle to resolve overlap-pin... In dry-coupled ultrasonic thickness measurement,thick rubber layers introduce high-amplitude parasitic echoes that obscure defect signals and degrade thickness accuracy.Existing methods struggle to resolve overlap-ping echoes under variable coupling conditions and non-stationary noise.This study proposes a novel dual-criterion framework integrating energy contribution and statistical impulsivity metrics to isolate specimen re-flections from coupling-layer interference.By decomposing A-scan signals into Intrinsic Mode Functions(IMFs),the framework employs energy contribution thresholds(>85%)and kurtosis indices(>3)to autonomously select IMFs containing valid specimen echoes.Hybrid time-frequency thresholding further suppresses interference through amplitude filtering and spectral focusing.Experimental results demonstrate the framework’s robustness,achieving 92.3%thickness accuracy for 5 mm steel specimens with 5 mm rubber coupling,outperforming conventional methods by up to 18.7%.The dual-criterion approach reduces operator dependency by 37%and maintainsΔT<0.03 mm under surface roughness up to 6.3μm,offering a practical solution for industrial nondestructive testing with thick dry-coupled interfaces. 展开更多
关键词 Empirical mode decomposition complete ensemble EMD with adaptive noise(CEEMDAN) dry-coupled ultrasonic testing thickness measurement signal interference suppression
在线阅读 下载PDF
HALIMA:a hybrid array for lifetime measurement of neutron-rich nuclei at IMP
17
作者 Zi-Hao Jia Yong-De Fang +37 位作者 Si-Cheng Wang Wei Hua Hong-Yi Wu Guang-Xin Zhang Cen-Xi Yuan Zhi-Xuan Wang Jun-Hong Xu Jian-Hong Li Wen Liang Yu-Hong Tan Wen-Jun Pan Yu-Xuan Ren MKumar Raju Song Guo Guang-Shun Li Yun-Hua Qiang Min-Liang Liu Bing Ding Ming-Hui Huang Ning-Tao Zhang Bing-Shui Gao Peng Ma He-Run Yang Ruo-Fu Chen Hai-Xia Li Rong-Hua Li Xiu-Hua Wang Cui-Hong Chen Hai-Bo Yang Jian-Song Wang Xiao-Hui Sun Zhi-Huan Li Hui Hua Wei Wang Xin-Xing Xu Xiao-Hong Zhou Zai-Guo Gan Yu-Hu Zhang 《Nuclear Science and Techniques》 2026年第2期169-182,共14页
A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detecto... A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detectors and twenty fast Ce-doped Lanthanum Bromide[LaBr_(3)(Ce)]detectors shielded with CsI(Tl).HALIMA is further complemented by two ancillary detector systems:fission fragment(FF)detectors and β detectors.This configuration enables precise sub-nanosecond lifetime measurements using the fourfold FF/β-Ge-LaBr_(3)(Ce)-LaBr_(3)(Ce)coincidence technique.The performance and specifications of the detectors,associated electronics,and the data acquisition system are presented in detail.The advantage of FF selectivity is emphasized,which significantly enhances sensitivity to specific fission channels.Using this approach,the lifetimes of the nuclear excited states populated in the spontaneous fission of^(252)Cf were measured,showing good agreement with the established literature values. 展开更多
关键词 FFs/β-γrays coincidences SELECTIVITY Spontaneous fission LaBr_(3)(Ce) HPGE Solar cells Lifetime measurement
在线阅读 下载PDF
On-line measurement of temperature and water vapor in CH_4 /air premixed flame using near-infrared diode laser 被引量:5
18
作者 陶波 叶锡生 +2 位作者 胡志云 张立荣 刘晶儒 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第11期1098-1101,共4页
We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for t... We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for temperature measurements.The measurements are performed on a flat burner based on scannedwavelength direct absorption spectroscopy using two adjacent water lines at 7153.75 and 7154.35 cm 1.Real-time results are acquired using a data acquisition card with a Labview data processing program.The standard uncertainties of the temperature and water concentration measurements are 2.3% and 5.1%,respectively. 展开更多
关键词 Data acquisition Data handling Infrared lasers Semiconductor lasers Temperature measurement Uncertainty analysis Water absorption Water piping systems Water supply Water vapor
原文传递
Integrated On-line Instrumentation System of Magnetic Properties Measurement
19
作者 D.G.Park, Y.Y.Song. H.Song and J.H.Hong (Korea Atomic Energy Research Institute, Yusong P.O.Box 105, Taejon, 305-600 Korea) C.G.Kim (Department of Physics, Sun Moon Univ., Asan-si, Chungnam, 336840 Korea) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期248-249,共2页
A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field duri... A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation. 展开更多
关键词 line Integrated on-line Instrumentation System of Magnetic Properties measurement
在线阅读 下载PDF
On-line Temperature Rise Measurement of Submersible Motors
20
作者 王凤昌 刘宝廷 +1 位作者 宋黎明 姜思杰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1995年第1期47-49,共3页
A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put fo... A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put forward here. The design and some experimental results are given. 展开更多
关键词 ss: SUBMERSIBLE MOTOR TEMPERATURE RISE on-line measurement
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部