A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field duri...A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation.展开更多
The response and performance of radiation detectors for accurate measurements and effective use for radiological safety in medical, industrial, and nuclear sectors are based on the optimal use, maintenance, repair and...The response and performance of radiation detectors for accurate measurements and effective use for radiological safety in medical, industrial, and nuclear sectors are based on the optimal use, maintenance, repair and calibration of radiation monitoring instruments in a secondary standard dosimetry laboratory. In Nigeria, the suboptimal performances of these instruments are attributed to inadequate maintenance practices, insufficient calibration, and limited awareness of proper equipment handling for optimal use. This study assesses the current practices related to the optimal use, maintenance, repair, and calibration of radiation detection equipment across Nigeria’s six geopolitical zones. Using a cross-sectional survey approach, data were collected from Ninety (90) radiation monitoring equipment operators, Radiation Safety Officers, and frontline responders to evaluate their knowledge, awareness, and practices concerning equipment usage, operation, storage, handling, and calibration. The findings reveal significant gaps in knowledge of usage (trained is 43.2%, not trained is 56.8%) and inconsistencies in maintenance practices (as indicated by the regression analysis (β = 0.51, p < 0.01), particularly regarding specialized instruments such as the PackEye, Mobile Detection System (MDS), Radionuclide Identifinder (RID), and Personal Radiation Detectors (PRD). While there is high awareness of the need for regular calibration and handling training, the lack of standardized protocols and training alignment poses challenges to the effective use of these instruments. This study underscores the importance of comprehensive training programs, standardized maintenance protocols, and enhanced awareness initiatives to optimize the usage, performance and safety of radiation monitoring instruments in Nigeria.展开更多
Objective:To evaluate the effectiveness of quality nursing in the management of reusable instruments in the Central Sterile Supply Department(CSSD).Methods:Eleven nurses from the CSSD department were selected from Jan...Objective:To evaluate the effectiveness of quality nursing in the management of reusable instruments in the Central Sterile Supply Department(CSSD).Methods:Eleven nurses from the CSSD department were selected from January to October 2024,and quality nursing activities were implemented in the management of reusable instruments.The completion of quality indicators was analyzed.The instrument quality management scores,department satisfaction,and nurses’professional ability scores before and after nursing management were compared.Results:After nursing intervention,the qualified rates of initial cleaning and final cleaning of sterilization instruments were 99.66%and 100%,respectively.The qualified rate of packaging was 99.97%,the wet package rate was 0.1‰,the loading qualified rate was 99.88%,and the qualified rate of distribution was 99.99%.After nursing intervention,the nurses’instrument quality management scores,department satisfaction,and nurses’professional ability scores were all higher than those before nursing intervention(P<0.05).Conclusion:Quality nursing activities can improve the cleaning,packaging,and sterilization qualified rates of reusable instruments in the CSSD,enhance the effect of instrument quality management,obtain higher department satisfaction from nurses,cultivate their professional abilities,and possess significant nursing management advantages.展开更多
This editorial introduces a special issue dedicated to the technical advancements in medical imaging.Medical imaging is an essential component of modern medicine,enabling the detection and analysis of structures and f...This editorial introduces a special issue dedicated to the technical advancements in medical imaging.Medical imaging is an essential component of modern medicine,enabling the detection and analysis of structures and functions within the human body.Among the key imaging modalities are X‐ray,ultrasound,computed tomography(CT),magnetic resonance imaging(MRI),positron emission tomography(PET),and single‐photon emission computed tomography.Each of these technologies plays a vital role in diagnostics and research,and their continued development drives progress in diagnostic imaging and related disciplines.展开更多
This paper introduces the key design aspects of automotive center console instrument systems,including hardware architecture,ergonomics,antenna layout,etc.It elaborates on the application and advantages of various adv...This paper introduces the key design aspects of automotive center console instrument systems,including hardware architecture,ergonomics,antenna layout,etc.It elaborates on the application and advantages of various advanced technologies,such as 3D printing and dual-color injection molding.Additionally,it discusses advancements in structural design,as well as future challenges and the trend of multidisciplinary collaborative innovation.展开更多
A rapid and simple liquid chromatography method with on-line solid phase extraction was developed and validated for the quantitative determination of cyclophosphamide in rat plasma.The plasma sample was first extracte...A rapid and simple liquid chromatography method with on-line solid phase extraction was developed and validated for the quantitative determination of cyclophosphamide in rat plasma.The plasma sample was first extracted on an Acclaim? Polar Advantage II C18 guard column(PA II C18,10 mm×4.6 mm,5 μm),which was also the on-line Extraction Cartridge SPE column,by washing with 100% H2O for 1 min.The extracted sample was then eluted onto a PA II C18 column(150 mm×4.6 mm,5 μm) and separated by isocratic elution with acetonitrile-water(40:60,v/v).The mobile phase was run at a flow rate of 1.0 mL/min,and the UV detector was set at 195 nm.Retention time of cyclophosphamide was 4.3 min and the total run-time was 6 min.The linear range of the standard curve was from 1.0 to 200 μg/mL(r2 = 0.9999),and the limits of quantification and detection were 1.0 μg/mL(RSD10%,n = 5) and 0.3 μg/mL(RSD13%,n = 5),respectively.Both intra-and inter-day variations were less than 5.6%.The developed method can be used for the therapeutic drug monitoring of cyclophosphamide in the clinic.展开更多
This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te...This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate.展开更多
The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sens...The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sensor (AE) with motor current sensor was presented. The parallel communication between control system of machine tools, the monitoring intelligent system,and several decision-making systems for identifying tool cutting state was established It can auto - matically select the sensor way ,monitoring mode and identifying method in machining process- ing so as to build a successful and effective intelligent system for on -line and real-time moni- toring cutting tool states in FMS.展开更多
The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through...The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through on-line solution and off-line aging treatment but decreases after off-line solution treatment. By X-ray diffractometry, optical microscopy, differential thermal analysis, scanning electron microscopy and X-ray energy dispersive spectroscopy, it is found that the microstructures of the die-cast AZ91D magnesium alloy before and after on-line solution and off-line aging are similar, consisting of α-Mg and β-Al12Mg17. The precipitation of Al element is prevented by on-line solution so that the effect of solid solution strengthening is enhanced. The β-Al12Mg17 phases precipitate from supersaturated Mg solid solution after off-line aging treatment, and lead to microstructure refinement of AZ91D alloy, so the effect of precipitation hardening is enhanced. The β-Al12Mg17 phases dissolve in the substructure after off-line solution treatment, which leads to that the grain boundary strengthening phase is reduced significantly and the hardness of die cast AZ91D is reduced.展开更多
We have developed an on-line detection method using acridine orange as the fluorescence probe and applied this method to rapidly identify active compounds in herbal medicines. This on-line method was equipped with a h...We have developed an on-line detection method using acridine orange as the fluorescence probe and applied this method to rapidly identify active compounds in herbal medicines. This on-line method was equipped with a high-performance liquid chromatography tandem diode array detector, electrospray ionization-ion-trap time-of-flight mass spectrometry and DNA- acridine orange fluorescence detection (HPLC-DAD-MSn-DNA-AO-FLD). A large amount of information could be simultaneously obtained during one run, which included HPLC fingerprint, ultraviolet spectra, total ion chromatograms, MSn data of high-resolution mass spectrometry and activity profile of each compound binding with DNA. The method also provided information on structureactivity relationships and mechanism of interaction. We used this on-line method to identify five DNA-binding activity components from Lithospermum erythrorhizon sample for the first time. The result showed that the parent nucleus of shikonin derivatives could bind with DNA. The structure-activity relationship showed that the parent nucleus of shikonin derivatives plays a major role in DNA binding, not the carboxyl group on the side chain. This simple, rapid, high precision and good stability on-line method should be useful for compound separation, structural identification and screening of DNA-binding compounds in herbal medicines.展开更多
A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The te...A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The technique can detect breakage of drills having diameter over 0.8mm,turning cutter crack of area over 0.2mm,and the ultimate wear.The principle,system construction,experimental method and result of the technique are discussed.The ratio of success in detection approaches 96% or higher.展开更多
基金Reactor Pressure Boundary Materials Project !under the Nuclear R & D Program by MOST in Korea.
文摘A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation.
文摘The response and performance of radiation detectors for accurate measurements and effective use for radiological safety in medical, industrial, and nuclear sectors are based on the optimal use, maintenance, repair and calibration of radiation monitoring instruments in a secondary standard dosimetry laboratory. In Nigeria, the suboptimal performances of these instruments are attributed to inadequate maintenance practices, insufficient calibration, and limited awareness of proper equipment handling for optimal use. This study assesses the current practices related to the optimal use, maintenance, repair, and calibration of radiation detection equipment across Nigeria’s six geopolitical zones. Using a cross-sectional survey approach, data were collected from Ninety (90) radiation monitoring equipment operators, Radiation Safety Officers, and frontline responders to evaluate their knowledge, awareness, and practices concerning equipment usage, operation, storage, handling, and calibration. The findings reveal significant gaps in knowledge of usage (trained is 43.2%, not trained is 56.8%) and inconsistencies in maintenance practices (as indicated by the regression analysis (β = 0.51, p < 0.01), particularly regarding specialized instruments such as the PackEye, Mobile Detection System (MDS), Radionuclide Identifinder (RID), and Personal Radiation Detectors (PRD). While there is high awareness of the need for regular calibration and handling training, the lack of standardized protocols and training alignment poses challenges to the effective use of these instruments. This study underscores the importance of comprehensive training programs, standardized maintenance protocols, and enhanced awareness initiatives to optimize the usage, performance and safety of radiation monitoring instruments in Nigeria.
文摘Objective:To evaluate the effectiveness of quality nursing in the management of reusable instruments in the Central Sterile Supply Department(CSSD).Methods:Eleven nurses from the CSSD department were selected from January to October 2024,and quality nursing activities were implemented in the management of reusable instruments.The completion of quality indicators was analyzed.The instrument quality management scores,department satisfaction,and nurses’professional ability scores before and after nursing management were compared.Results:After nursing intervention,the qualified rates of initial cleaning and final cleaning of sterilization instruments were 99.66%and 100%,respectively.The qualified rate of packaging was 99.97%,the wet package rate was 0.1‰,the loading qualified rate was 99.88%,and the qualified rate of distribution was 99.99%.After nursing intervention,the nurses’instrument quality management scores,department satisfaction,and nurses’professional ability scores were all higher than those before nursing intervention(P<0.05).Conclusion:Quality nursing activities can improve the cleaning,packaging,and sterilization qualified rates of reusable instruments in the CSSD,enhance the effect of instrument quality management,obtain higher department satisfaction from nurses,cultivate their professional abilities,and possess significant nursing management advantages.
文摘This editorial introduces a special issue dedicated to the technical advancements in medical imaging.Medical imaging is an essential component of modern medicine,enabling the detection and analysis of structures and functions within the human body.Among the key imaging modalities are X‐ray,ultrasound,computed tomography(CT),magnetic resonance imaging(MRI),positron emission tomography(PET),and single‐photon emission computed tomography.Each of these technologies plays a vital role in diagnostics and research,and their continued development drives progress in diagnostic imaging and related disciplines.
文摘This paper introduces the key design aspects of automotive center console instrument systems,including hardware architecture,ergonomics,antenna layout,etc.It elaborates on the application and advantages of various advanced technologies,such as 3D printing and dual-color injection molding.Additionally,it discusses advancements in structural design,as well as future challenges and the trend of multidisciplinary collaborative innovation.
基金National Natural Science Foundation of China(Grant No.81072612)the Natural Science Foundation of Beijing(Grant No.7102107)+1 种基金the Open Foundation of State Key Laboratory of Natural and Biomimetic Drugs(Grant No.K20110109)Specialized Research Fund for the Doctoral Program of Higher Education(Grant No.20110001110021)
文摘A rapid and simple liquid chromatography method with on-line solid phase extraction was developed and validated for the quantitative determination of cyclophosphamide in rat plasma.The plasma sample was first extracted on an Acclaim? Polar Advantage II C18 guard column(PA II C18,10 mm×4.6 mm,5 μm),which was also the on-line Extraction Cartridge SPE column,by washing with 100% H2O for 1 min.The extracted sample was then eluted onto a PA II C18 column(150 mm×4.6 mm,5 μm) and separated by isocratic elution with acetonitrile-water(40:60,v/v).The mobile phase was run at a flow rate of 1.0 mL/min,and the UV detector was set at 195 nm.Retention time of cyclophosphamide was 4.3 min and the total run-time was 6 min.The linear range of the standard curve was from 1.0 to 200 μg/mL(r2 = 0.9999),and the limits of quantification and detection were 1.0 μg/mL(RSD10%,n = 5) and 0.3 μg/mL(RSD13%,n = 5),respectively.Both intra-and inter-day variations were less than 5.6%.The developed method can be used for the therapeutic drug monitoring of cyclophosphamide in the clinic.
文摘This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate.
文摘The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sensor (AE) with motor current sensor was presented. The parallel communication between control system of machine tools, the monitoring intelligent system,and several decision-making systems for identifying tool cutting state was established It can auto - matically select the sensor way ,monitoring mode and identifying method in machining process- ing so as to build a successful and effective intelligent system for on -line and real-time moni- toring cutting tool states in FMS.
基金Projects (2011BAE22B01, 2011BAE22B06) supported by the National Key Technologies R&D Program During the 12th Five-Year Plan Period of ChinaProject (2010NC018) supported by the Innovation Fund of Inner Mongolia University of Science and Technology, China
文摘The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through on-line solution and off-line aging treatment but decreases after off-line solution treatment. By X-ray diffractometry, optical microscopy, differential thermal analysis, scanning electron microscopy and X-ray energy dispersive spectroscopy, it is found that the microstructures of the die-cast AZ91D magnesium alloy before and after on-line solution and off-line aging are similar, consisting of α-Mg and β-Al12Mg17. The precipitation of Al element is prevented by on-line solution so that the effect of solid solution strengthening is enhanced. The β-Al12Mg17 phases precipitate from supersaturated Mg solid solution after off-line aging treatment, and lead to microstructure refinement of AZ91D alloy, so the effect of precipitation hardening is enhanced. The β-Al12Mg17 phases dissolve in the substructure after off-line solution treatment, which leads to that the grain boundary strengthening phase is reduced significantly and the hardness of die cast AZ91D is reduced.
基金Peking University Comprehensive Platform for Innovative Drug Research and Development(Grant No.2009ZX--09301--010)
文摘We have developed an on-line detection method using acridine orange as the fluorescence probe and applied this method to rapidly identify active compounds in herbal medicines. This on-line method was equipped with a high-performance liquid chromatography tandem diode array detector, electrospray ionization-ion-trap time-of-flight mass spectrometry and DNA- acridine orange fluorescence detection (HPLC-DAD-MSn-DNA-AO-FLD). A large amount of information could be simultaneously obtained during one run, which included HPLC fingerprint, ultraviolet spectra, total ion chromatograms, MSn data of high-resolution mass spectrometry and activity profile of each compound binding with DNA. The method also provided information on structureactivity relationships and mechanism of interaction. We used this on-line method to identify five DNA-binding activity components from Lithospermum erythrorhizon sample for the first time. The result showed that the parent nucleus of shikonin derivatives could bind with DNA. The structure-activity relationship showed that the parent nucleus of shikonin derivatives plays a major role in DNA binding, not the carboxyl group on the side chain. This simple, rapid, high precision and good stability on-line method should be useful for compound separation, structural identification and screening of DNA-binding compounds in herbal medicines.
文摘A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The technique can detect breakage of drills having diameter over 0.8mm,turning cutter crack of area over 0.2mm,and the ultimate wear.The principle,system construction,experimental method and result of the technique are discussed.The ratio of success in detection approaches 96% or higher.