Rapid screening of inorganic arsenic(iAs)in groundwater used for drinking by hundreds of millions of mostly rural residents worldwide is crucial for health protection.Most commercial field test kits are based on the G...Rapid screening of inorganic arsenic(iAs)in groundwater used for drinking by hundreds of millions of mostly rural residents worldwide is crucial for health protection.Most commercial field test kits are based on the Gutzeit reaction that uses mercury-based reagents for color development,an environmental concern that increasingly limits its utilization.This study further improves the Molybdenum Blue(MB)colorimetric method to allow for faster screening with more stable reagents.More importantly,a portable three-channel colorimeter is developed for screening iAs relative to the WHO drinking water guideline value(10μg/L).Adding the reducing reagents in sequence not only prolongs the storage time to>7 days,but also accelerates the color development time to 6 min in conjunction with lowering the H_(2)SO_(4) concentration in chromogenic reagents.The optimal pH ranges from 1.2 to 1.3 and is achieved by acidifying groundwater to 1%(V/V)HCl.With detection limits of 3.7μg/L for inorganic arsenate(iAs(V))and 3.8μg/L for inorganic arsenite(iAs(Ⅲ)),testing groundwater with-10μg/L of As has a precision<20%.The method works well for a range of phosphate concentrations of 48-950μg/L(0.5-10μmol/L).Concentrations of total_iAs(6-300μg/L),iAs(V)(6-230μg/L)and iAs(Ⅲ)(0-170μg/L)for 14 groundwater samples from Yinchuan Plain,Pearl River Delta,and Jianghan Plain,are in excellent agreements(linear regression slope:0.969-1.029)with the benchmark methods.The improved chemistry here lays the foundation for the MB colorimetric method to become a commercially viable screening tool,with further engineering and design improvement of the colorimeter.展开更多
Acrylamide(AA)is a neurotoxin and carcinogen that formed during the thermal food processing.Conventional quantification techniques are difficult to realize on-site detection of AA.Herein,a flower-like bimetallic FeCu ...Acrylamide(AA)is a neurotoxin and carcinogen that formed during the thermal food processing.Conventional quantification techniques are difficult to realize on-site detection of AA.Herein,a flower-like bimetallic FeCu nanozyme(FeCuzyme)sensor and portable platform were developed for naked-eye and on-site detection of AA.The FeCuzyme was successfully prepared and exhibited flower-like structure with 3D catalytic centers.Fe/Cu atoms were considered as active center and ligand frameworks were used as cofactor,resulting in collaborative substrate-binding features and remarkably peroxidase-like activity.During the catalytic process,the 3,3′,5,5′-tetrame-thylbenzidine(TMB)oxidation can be quenched by glutathione(GSH),and then restored after thiolene Michael addition reaction between GSH and AA.Given the“on–off–on”effect for TMB oxidation and high PODlike activity,FeCuzyme sensor exhibited a wide linear relationship from 0.50 to 18.00μM(R^(2)=0.9987)and high sensitivity(LOD=0.2360μM)with high stability.The practical application of FeCuzyme sensor was successfully validated by HPLC method.Furthermore,a FeCuzyme portable platform was designed with smartphone/laptop,and which can be used for naked-eye and on-site quantitative determination of AA in real food samples.This research provides a way for rational design of a novel nanozyme-based sensing platform for AA detection.展开更多
To accomplish on-site separation, preconcentration and cold storage of highly volatile organic compounds(VOCs) from water samples as well as their rapid transportation to laboratory, a high-throughput miniaturized pur...To accomplish on-site separation, preconcentration and cold storage of highly volatile organic compounds(VOCs) from water samples as well as their rapid transportation to laboratory, a high-throughput miniaturized purge-and-trap(μP&T) device integrating semiconductor refrigeration storage was developed in this work. Water samples were poured into the purge vessels and purged with purified air generated by an air pump. The VOCs in water samples were then separated and preconcentrated with sorbent tubes. After their complete separation and preconcentration, the tubes were subsequently preserved in the semiconductor refrigeration unit of the μP&T device. Notably, the high integration, small size, light weight, and low power consumption of the device makes it easy to be hand-carried to the field and transport by drone from remote locations, significantly enhancing the flexibility of field sampling. The performances of the device were evaluated by comparing analytical figures of merit for the detection of four cyclic volatile methylsiloxanes(cVMSs) in water. Compared to conventional collection and preservation methods, our proposed device preserved the VOCs more consistently in the sorbent tubes, with less than 5% loss of all analytes, and maintained stability for at least 20 days at 4℃. As a proof-of-concept,10 municipal wastewater samples were pretreated using this device with recoveries ranging from 82.5% to 99.9% for the target VOCs.展开更多
One of the primary tasks of earthquake early warning(EEW)systems is to predict potential earthquake damage rapidly and accurately.Cumulative absolute velocity(CAV),Arias intensity(I_(A)),and spectrum intensity(SI)are ...One of the primary tasks of earthquake early warning(EEW)systems is to predict potential earthquake damage rapidly and accurately.Cumulative absolute velocity(CAV),Arias intensity(I_(A)),and spectrum intensity(SI)are important parameters for measuring ground motion intensity and assessing earthquake damage.Due to the limited available information in EEW,CAV,I_(A),and SI cannot be accurately predicted using traditional EEW methods.In this paper,we propose an end-to-end deep learning-based Ground motion Intensity prediction Network(ENGINet)for on-site EEW.The aim of the ENGINet is to predict CAV,I_(A),and SI rapidly and reliably.ENGINet is based on a convolutional neural network and recurrent neural network.The inputs of the network are three-component acceleration records,three-component velocity records,and three-component displacement records obtained by a single station.The results from the test dataset show that at 3 s after the P-wave arrival,compared with the baseline models and other traditional methods,ENGINet has better performance in predicting CAV,I_(A),and SI.Our results indicate that ENGINet can quickly and accurately predict CAV,I_(A),and SI to some extent and has good potential in EEW efforts.展开更多
The integration of Global Navigation Satellite System(GNSS)technology into railway train control systems is a crucial step toward achieving the vision of a digital railway.Traditional train control systems undergo ext...The integration of Global Navigation Satellite System(GNSS)technology into railway train control systems is a crucial step toward achieving the vision of a digital railway.Traditional train control systems undergo extensive in-house tests and prolonged field tests for certification and approval before operational deployment,leading to high costs,delays,and operational disruptions.This paper introduces a GNSS-based train control localization framework which eliminates the need for on-site testing by leveraging train movement dynamics and 3D environment modeling to create a zero on-site testing platform.The proposed framework simulates train movement and the surrounding 3D environment using collected railway line location data and environmental attributes to generate realistic multipath signals and obscuration effects.This approach enables comprehensive laboratory-based case studies for train localization,reducing the huge amount test of needed for physical field trials.The framework is established in house,using the data collected at the Test Base of China Academy of Railway Sciences(Circular Railway).Results from the open area and cutting environment tests demonstrate high localization accuracy repeatability within the simulated environment,validating the feasibility and effectiveness of zero on-site testing for GNSS-based train control systems.This research highlights the potential of GNSS simulation platforms in enhancing cost efficiency,operational safety,and accuracy for future digital railways.展开更多
Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSP...Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSPS and Cry1Ab/Ac was proposed and combined with a lateral flow immunochromatographic assay,named“Dual-RPA-LFD”,to visualize the dual detection of genetically modified(GM)crops.In which,the herbicide tolerance gene CP4-EPSPS and the insect resistance gene Cry1Ab/Ac were selected as targets taking into account the current status of the most widespread application of insect resistance and herbicide tolerance traits and their stacked traits.Gradient diluted plasmids,transgenic standards,and actual samples were used as templates to conduct sensitivity,specificity,and practicality assays,respectively.The constructed method achieved the visual detection of plasmid at levels as low as 100 copies,demonstrating its high sensitivity.In addition,good applicability to transgenic samples was observed,with no cross-interference between two test lines and no influence from other genes.In conclusion,this strategy achieved the expected purpose of simultaneous detection of the two popular targets in GM crops within 20 min at 37°C in a rapid,equipmentfree field manner,providing a new alternative for rapid screening for transgenic assays in the field.展开更多
The preparation of large crystals is highly important for the characterization and application of a newly found structure but remains a challenge for one-dimensional(1D)C_(60) polymers.In this work,we successfully fab...The preparation of large crystals is highly important for the characterization and application of a newly found structure but remains a challenge for one-dimensional(1D)C_(60) polymers.In this work,we successfully fabricated a 1D C_(60) polymer crystal via on-site annealing of a millimeter-sized C_(60) molecular crystal withα-Li_(3)N at 500°C and ambient pres�sure.Characterizations show that the C_(60) cages in the crystal have been efficiently connected,forming 1D chains along the<110>direction in an orthorhombic 3D structure.At the same time,the crystal maintains a morphology similar to that of the pristine C_(60)crystal,providing opportunities for characterization of all the facets of the crystal via Raman spectroscopy and thus suggesting the formation mechanism of such crystals.展开更多
BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent stud...BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent studies suggest that MOSE by the endoscopist may be an excellent alternative to rapid on-site evaluation,and some classi-fications have been published.Few studies have assessed the adequacy of histologic cores in MOSE during endoscopic ultrasound-guided fine-needle aspiration/biopsy(EUS-FNA/FNB).AIM To evaluate the performance of MOSE during EUS-FNA/FNB.METHODS This multicentric prospective study was conducted in 16 centers in 3 countries(Egypt,Iraq,and Morocco)and included 1108 patients with pancreatic,biliary,or gastrointestinal pathology who were referred for EUS examination.We prospectively analyzed the MOSE in 1008 patients with available histopathological reports according to 2 classifications to determine the adequacy of the histological core samples.Data management and analysis were performed using a Statistical Package for Social Sciences(SPSS)version 27.RESULTS A total of 1074 solid lesions were biopsied in 1008 patients with available cytopathological reports.Mean age was 59 years,and 509 patients(50.5%)were male.The mean lesion size was 38 mm.The most frequently utilized needles were FNB-Franseen(74.5%)and 22 G(93.4%),with a median of 2 passes.According to 2 classifications,618 non-bloody cores(61.3%)and 964 good samples(95.6%)were adequate for histological evaluation.The overall diagnostic yield of cytopathology was 95.5%.The cytological examination confirmed the diagnosis of malignancy in 861 patients(85.4%),while 45 samples(4.5%)were inconclusive.Post-procedural adverse events occurred in 33 patients(3.3%).Statistical analysis showed a difference between needle types(P=0.035)with a high sensitivity of FNB(97%).The analysis of the relationship between the MOSE-score and the final diagnosis showed a significant difference between the different scores of the MOSE(P<0.001).CONCLUSION MOSE is a simple method that allows endoscopists to increase needle passes to improve sample quality.There is significantly higher FNB sensitivity and cytopathology diagnostic yield with good MOSE cores.展开更多
Endoscopic ultrasound (EUS) has become an essential tool for the study of pancreatic diseases. Specifically, EUS plays a pivotal role evaluating patients with a known or suspected pancreatic mass. In this setting, dif...Endoscopic ultrasound (EUS) has become an essential tool for the study of pancreatic diseases. Specifically, EUS plays a pivotal role evaluating patients with a known or suspected pancreatic mass. In this setting, differential diagnosis remains a clinical challenge. EUS-guided fine-needle aspiration (FNA) and fine-needle biopsy (FNB) have been proven to be safe and useful tools in this setting. EUS-guided FNA and FNB, by obtaining cytological and/or histological samples, are able to diagnose pancreatic lesions with high sensitivity and specificity. In this context, several methodological features, trying to increase the diagnostic yield of EUS-guided FNA and FNB, have been evaluated. In this review, we focus on the role of rapid on-site evaluation (ROSE). From data reported in the literature, ROSE may increase diagnostic yield of EUS-FNA specimens by 10%-30%, and thus, diagnostic accuracy. However, we should point out that many recent studies have reported adequacy rates of > 90% without ROSE, indicating that, perhaps, at high-volume centers, ROSE may not be indispensable to achieve excellent results. The use of ROSE can be considered important during the learning curve of EUS-FNA, and also in hospital with diagnostic accuracy rates < 90%.展开更多
A“cloud-edge-end”collaborative system architecture is adopted for real-time security management of power system on-site work,and mobile edge computing equipment utilizes lightweight intelligent recognition algorithm...A“cloud-edge-end”collaborative system architecture is adopted for real-time security management of power system on-site work,and mobile edge computing equipment utilizes lightweight intelligent recognition algorithms for on-site risk assessment and alert.Owing to its lightweight and fast speed,YOLOv4-Tiny is often deployed on edge computing equipment for real-time video stream detection;however,its accuracy is relatively low.This study proposes an improved YOLOv4-Tiny algorithm based on attention mechanism and optimized training methods,achieving higher accuracy without compromising the speed.Specifically,a convolution block attention module branch is added to the backbone network to enhance the feature extraction capability and an efficient channel attention mechanism is added in the neck network to improve feature utilization.Moreover,three optimized training methods:transfer learning,mosaic data augmentation,and label smoothing are used to improve the training effect of this improved algorithm.Finally,an edge computing equipment experimental platform equipped with an NVIDIA Jetson Xavier NX chip is established and the newly developed algorithm is tested on it.According to the results,the speed of the improved YOLOv4-Tiny algorithm in detecting on-site dress code compliance datasets is 17.25 FPS,and the mean average precision(mAP)is increased from 70.89%to 85.03%.展开更多
Approximately 94 to 220 million people worldwide are at risk of drinking well water containing arsenic > 10 μg/L, the WHO guideline value. To identify non-compliant domestic wells, assess health risks and reduce e...Approximately 94 to 220 million people worldwide are at risk of drinking well water containing arsenic > 10 μg/L, the WHO guideline value. To identify non-compliant domestic wells, assess health risks and reduce exposure, accurate and rapid on-site inorganic arsenic screening methods are desirable because all domestic wells worldwide need to be tested.Here, the principles, advantages and limitations of commonly used colorimetry, electrochemistry, and biosensing methods are critically reviewed, with the performance compared with laboratory-based benchmark methods. Most commercial kits are based on the classic Gutzeit reaction. Despite being semi-quantitative, the more recent and more expensive products display improved and acceptable accuracy and shorter testing time (~10 min). Carried out by trained professionals, electrochemical methods are also feasible for on-site analysis, although miniaturization is desirable yet challenging. Biosensing using whole bacterial cells or bio-engineered materials such as aptamers is promising, if incorporated with function specific nanomaterials and biomaterials. Since arsenic is frequently found as arsenite in reducing groundwater and subject to oxidation during sampling, transportation and storage, on-site separation and sample preservation are feasible but the specific methods should be chosen based on sample matrix and tested before use. To eliminate arsenic exposure among hundreds of millions of mostly rural residents worldwide, we call for concerted efforts in research community and regulatory authority to develop accurate, rapid, and affordable tests for on-site screening and monitoring of arsenic in drinking water. Access to affordable testing will benefit people who are socioeconomically disadvantaged.展开更多
Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluat...Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluation(MOSE)performed by an endoscopist was introduced as an alternative to rapid on-site cytologic evaluation to increase the diagnostic yield of EUS-FNB.The MOSE of the biopsy can estimate the adequacy of the sample directly by the macroscopic evaluation of the core tissue obtained from EUS-FNB.Isolated pancreatic tuberculosis is extremely rare and difficult to diagnose because of its non-specific signs and symptoms.Therefore,this challenging diagnosis is based on endoscopy,imaging,and the bacteriological and histological examination of tissue biopsies.This uncommon presentation of tuberculosis can be revealed as pancreatic mass mimicking cancer.EUS-FNB can be very useful in providing a valuable histopathological diagnosis.A calcified lesion with a cheesy core in MOSE must be suggestive of tuberculosis,leading to the request of the GeneXpert,which can detect Mycobacterium tuberculosis deoxyribonucleic acid and resistance to rifampicin.A decent diagnostic strategy is crucial to prevent unnecessary surgical resection and to supply conservative management with antitubercular therapy.展开更多
On-site programming big data refers to the massive data generated in the process of software development with the characteristics of real-time,complexity and high-difficulty for processing.Therefore,data cleaning is e...On-site programming big data refers to the massive data generated in the process of software development with the characteristics of real-time,complexity and high-difficulty for processing.Therefore,data cleaning is essential for on-site programming big data.Duplicate data detection is an important step in data cleaning,which can save storage resources and enhance data consistency.Due to the insufficiency in traditional Sorted Neighborhood Method(SNM)and the difficulty of high-dimensional data detection,an optimized algorithm based on random forests with the dynamic and adaptive window size is proposed.The efficiency of the algorithm can be elevated by improving the method of the key-selection,reducing dimension of data set and using an adaptive variable size sliding window.Experimental results show that the improved SNM algorithm exhibits better performance and achieve higher accuracy.展开更多
We study the dynamical energy equipartition properties in the integrable Toda model with additional uniform or disordered on-site energies by extensive numerical simulations. The total energy is initially equidistribu...We study the dynamical energy equipartition properties in the integrable Toda model with additional uniform or disordered on-site energies by extensive numerical simulations. The total energy is initially equidistributed among some of the lowest frequency linear modes. For the Toda model with uniform on-site potentials, the energy spectrum keeps its profile nearly unchanged in a relatively short time scale. On a much longer time scale, the energies of tail modes increase slowly with time. Energy equipartition is far away from being attached in our studied time scale. For the Toda model with disordered on-site potentials, the energy transfers continuously to the high frequency modes and eventually towards energy equipartition. We further perform a systematic study of the equipartition time teq depending on the energy density ε and the nonlinear parameter α in the thermodynamic limit for the Toda model with disordered on-site potentials. We find teq∝ (1/ε)^a(1/α)^b, where b≈ 2a. The values of a and b are increased when increasing the strengths of disordered on-site potentials or decreasing the number of initially excited modes.展开更多
Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve...Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve of a train,the speed of which is over200km/h.Nevertheless the method has two limitations,one is large field-〇f-view(FO V),the other is calibration time.Hence portable calibration equipment,easy-t〇-build target and rapid calibration algorithm are required to complete the calibration.In this paper,a new rapid on-site calibration method with large FOV based on binocular stereo vision is proposed.To address these issues,a light target has been designed,the rail coordinate system(RCS)is represented by40fixed retroreflective points on the target,and they are utilized to calibrate the parameters of two cameras.In addition,two cameras merely capture a single image of the target simultaneously,and the intrinsic and extrinsic parameters of the cameras can be calculated rapidly.To testify the proposed method,the experiments have been conducted and the results reveal that the accuracy can reach+1mm,which can meet the measurement requirement.展开更多
According to different testing purposes, methods and available environmental conditions, the seismograph testing can be divided into laboratory and on-site testing, respectively. The testing of the seismograph's k...According to different testing purposes, methods and available environmental conditions, the seismograph testing can be divided into laboratory and on-site testing, respectively. The testing of the seismograph's key parameters and other concerning technical specifications are well described in guide documents(China Earthquake Administration, 2017). This includes seismometer sensitivity, linearity and clip levels based on the shake table test, as well as the seismometer natural period, damping constant based on electrical calibration(Wang Guangfu,1986; Ple?inger A.,1993) and instrumental self-noise collocation estimation(Holcomb L.G., 1989; Sleeman R. et al., 2006). However, with the development of seismic observation technology, many new requirements for the performance evaluation of seismographs have been put forward, and new testing items and methods have emerged.展开更多
Approximately 20% of homes nationwide use an on-site treatment system as a form of household wastewater management. However, approximately 10% to 20% of on-site treatment systems malfunction each year, many of which h...Approximately 20% of homes nationwide use an on-site treatment system as a form of household wastewater management. However, approximately 10% to 20% of on-site treatment systems malfunction each year, many of which have either failed or exceeded the soil’s long-term acceptance rate (LTAR), causing environmental and human health risks. The objective of this field study was to evaluate the effects of soil condition (e.g., wet and dry) and product architecture type [i.e., chamber, gravel-less-pipe (GLP), polystyrene-aggregate, and pipe-and-aggregate] on in-product solution storage and biomat thickness in a profile-limited soil in northwest Arkansas under increased loading rates and to estimate the LTAR for each product. During Phase I of this study (March 13 to October 4, 2013), effluent loading rates were approximately doubled, while rates were approximately quadrupled during Phase II (October 8, 2013 to May 29, 2014), from the maximum allowable loading rate for each product. The pipe-and-tire-chip, 46-cm-wide trench pipe-and-gravel, and the 25-cm diameter GLP products had the greatest (p < 0.001), while the 31-cm-width and the 5.4-m-long chambers had the lowest (p < 0.001) in-product solution storage during wet-soil conditions of Phase I monitoring. The 25-cm diameter GLP product had the greatest (p < 0.001), while the 61-cm-width, 5.4-m-long chamber had the lowest (p < 0.001) in-product solution storage during Phase II. Results of this study indicate that some alternative products may be able to effectively handle effluent loading rates in excess of those currently allowed by the State of Arkansas. Further research will be required to confirm these interpretations.展开更多
The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nu...The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary γ-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation.展开更多
A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to fur...A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to further diagnose and locate the potential problem of the cable system. This paper presents the experience of the present authors carrying out the cable test. Following a brief introduction to the experiment equipments and physical connections, the paper analyses the data collected from the testing, including PD pulse shape analysis, frequency spectrum analysis and phase resolved PD pattern analysis. Associated with PD propagation direction identification, PD source diagnosis and localisation was made. Four different types of sensors, which were adapted during the testing, are shown to have different frequency bandwidths and performed differently. Aider comparing the parameters of the sensor and the PD signals detected by individual sensor, optimal PD monitoring bandwidth for cable system is suggested.展开更多
基金the National Key R&D Program of China(No.2021YFA0715900)the National Natural Science Foundation of China(No.41831279)+2 种基金the Shenzhen Key Laboratory of Precision Measurement and Early Warning Technology for Urban Environmental Health Risks(No.ZDSYS20220606100604008)the Guangdong Province Bureau of Education(No.2020KCXTD006)the Guangdong Provincial Key Laboratory of Soil and Groundwater Pollution Control(No.2023B1212060002).
文摘Rapid screening of inorganic arsenic(iAs)in groundwater used for drinking by hundreds of millions of mostly rural residents worldwide is crucial for health protection.Most commercial field test kits are based on the Gutzeit reaction that uses mercury-based reagents for color development,an environmental concern that increasingly limits its utilization.This study further improves the Molybdenum Blue(MB)colorimetric method to allow for faster screening with more stable reagents.More importantly,a portable three-channel colorimeter is developed for screening iAs relative to the WHO drinking water guideline value(10μg/L).Adding the reducing reagents in sequence not only prolongs the storage time to>7 days,but also accelerates the color development time to 6 min in conjunction with lowering the H_(2)SO_(4) concentration in chromogenic reagents.The optimal pH ranges from 1.2 to 1.3 and is achieved by acidifying groundwater to 1%(V/V)HCl.With detection limits of 3.7μg/L for inorganic arsenate(iAs(V))and 3.8μg/L for inorganic arsenite(iAs(Ⅲ)),testing groundwater with-10μg/L of As has a precision<20%.The method works well for a range of phosphate concentrations of 48-950μg/L(0.5-10μmol/L).Concentrations of total_iAs(6-300μg/L),iAs(V)(6-230μg/L)and iAs(Ⅲ)(0-170μg/L)for 14 groundwater samples from Yinchuan Plain,Pearl River Delta,and Jianghan Plain,are in excellent agreements(linear regression slope:0.969-1.029)with the benchmark methods.The improved chemistry here lays the foundation for the MB colorimetric method to become a commercially viable screening tool,with further engineering and design improvement of the colorimeter.
基金supported by the National Natural Science Foundation of China(32060577 and 32360619)Natural Science Foundation of Jiangxi Province(20224ACB203016 and 20212BAB203034)the Open Project of China Food Flavor and Nutrition Health Innovation Center(CFC2023B-013).
文摘Acrylamide(AA)is a neurotoxin and carcinogen that formed during the thermal food processing.Conventional quantification techniques are difficult to realize on-site detection of AA.Herein,a flower-like bimetallic FeCu nanozyme(FeCuzyme)sensor and portable platform were developed for naked-eye and on-site detection of AA.The FeCuzyme was successfully prepared and exhibited flower-like structure with 3D catalytic centers.Fe/Cu atoms were considered as active center and ligand frameworks were used as cofactor,resulting in collaborative substrate-binding features and remarkably peroxidase-like activity.During the catalytic process,the 3,3′,5,5′-tetrame-thylbenzidine(TMB)oxidation can be quenched by glutathione(GSH),and then restored after thiolene Michael addition reaction between GSH and AA.Given the“on–off–on”effect for TMB oxidation and high PODlike activity,FeCuzyme sensor exhibited a wide linear relationship from 0.50 to 18.00μM(R^(2)=0.9987)and high sensitivity(LOD=0.2360μM)with high stability.The practical application of FeCuzyme sensor was successfully validated by HPLC method.Furthermore,a FeCuzyme portable platform was designed with smartphone/laptop,and which can be used for naked-eye and on-site quantitative determination of AA in real food samples.This research provides a way for rational design of a novel nanozyme-based sensing platform for AA detection.
基金the National Natural Science Foundation of China (No. 22306146)the PhD Scientific Research Startup Foundation of Xihua University (No. RX2200002003) for their financial support。
文摘To accomplish on-site separation, preconcentration and cold storage of highly volatile organic compounds(VOCs) from water samples as well as their rapid transportation to laboratory, a high-throughput miniaturized purge-and-trap(μP&T) device integrating semiconductor refrigeration storage was developed in this work. Water samples were poured into the purge vessels and purged with purified air generated by an air pump. The VOCs in water samples were then separated and preconcentrated with sorbent tubes. After their complete separation and preconcentration, the tubes were subsequently preserved in the semiconductor refrigeration unit of the μP&T device. Notably, the high integration, small size, light weight, and low power consumption of the device makes it easy to be hand-carried to the field and transport by drone from remote locations, significantly enhancing the flexibility of field sampling. The performances of the device were evaluated by comparing analytical figures of merit for the detection of four cyclic volatile methylsiloxanes(cVMSs) in water. Compared to conventional collection and preservation methods, our proposed device preserved the VOCs more consistently in the sorbent tubes, with less than 5% loss of all analytes, and maintained stability for at least 20 days at 4℃. As a proof-of-concept,10 municipal wastewater samples were pretreated using this device with recoveries ranging from 82.5% to 99.9% for the target VOCs.
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant No.2024B08。
文摘One of the primary tasks of earthquake early warning(EEW)systems is to predict potential earthquake damage rapidly and accurately.Cumulative absolute velocity(CAV),Arias intensity(I_(A)),and spectrum intensity(SI)are important parameters for measuring ground motion intensity and assessing earthquake damage.Due to the limited available information in EEW,CAV,I_(A),and SI cannot be accurately predicted using traditional EEW methods.In this paper,we propose an end-to-end deep learning-based Ground motion Intensity prediction Network(ENGINet)for on-site EEW.The aim of the ENGINet is to predict CAV,I_(A),and SI rapidly and reliably.ENGINet is based on a convolutional neural network and recurrent neural network.The inputs of the network are three-component acceleration records,three-component velocity records,and three-component displacement records obtained by a single station.The results from the test dataset show that at 3 s after the P-wave arrival,compared with the baseline models and other traditional methods,ENGINet has better performance in predicting CAV,I_(A),and SI.Our results indicate that ENGINet can quickly and accurately predict CAV,I_(A),and SI to some extent and has good potential in EEW efforts.
基金supported by the National Natural Science Foundation of China(62027809,U2268206,T2222015,U2468202).
文摘The integration of Global Navigation Satellite System(GNSS)technology into railway train control systems is a crucial step toward achieving the vision of a digital railway.Traditional train control systems undergo extensive in-house tests and prolonged field tests for certification and approval before operational deployment,leading to high costs,delays,and operational disruptions.This paper introduces a GNSS-based train control localization framework which eliminates the need for on-site testing by leveraging train movement dynamics and 3D environment modeling to create a zero on-site testing platform.The proposed framework simulates train movement and the surrounding 3D environment using collected railway line location data and environmental attributes to generate realistic multipath signals and obscuration effects.This approach enables comprehensive laboratory-based case studies for train localization,reducing the huge amount test of needed for physical field trials.The framework is established in house,using the data collected at the Test Base of China Academy of Railway Sciences(Circular Railway).Results from the open area and cutting environment tests demonstrate high localization accuracy repeatability within the simulated environment,validating the feasibility and effectiveness of zero on-site testing for GNSS-based train control systems.This research highlights the potential of GNSS simulation platforms in enhancing cost efficiency,operational safety,and accuracy for future digital railways.
基金supported by the Scientific and Innovative Action Plan of Shanghai(21N31900800)Shanghai Rising-Star Program(23QB1403500)+4 种基金the Shanghai Sailing Program(20YF1443000)Shanghai Science and Technology Commission,the Belt and Road Project(20310750500)Talent Project of SAAS(2023-2025)Runup Plan of SAAS(ZP22211)the SAAS Program for Excellent Research Team(2022(B-16))。
文摘Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSPS and Cry1Ab/Ac was proposed and combined with a lateral flow immunochromatographic assay,named“Dual-RPA-LFD”,to visualize the dual detection of genetically modified(GM)crops.In which,the herbicide tolerance gene CP4-EPSPS and the insect resistance gene Cry1Ab/Ac were selected as targets taking into account the current status of the most widespread application of insect resistance and herbicide tolerance traits and their stacked traits.Gradient diluted plasmids,transgenic standards,and actual samples were used as templates to conduct sensitivity,specificity,and practicality assays,respectively.The constructed method achieved the visual detection of plasmid at levels as low as 100 copies,demonstrating its high sensitivity.In addition,good applicability to transgenic samples was observed,with no cross-interference between two test lines and no influence from other genes.In conclusion,this strategy achieved the expected purpose of simultaneous detection of the two popular targets in GM crops within 20 min at 37°C in a rapid,equipmentfree field manner,providing a new alternative for rapid screening for transgenic assays in the field.
基金supported by the National Key R&D Program of China(2020YFA0711502)the National Natural Science Foundation of China(52325202,52202052,52373310)。
文摘The preparation of large crystals is highly important for the characterization and application of a newly found structure but remains a challenge for one-dimensional(1D)C_(60) polymers.In this work,we successfully fabricated a 1D C_(60) polymer crystal via on-site annealing of a millimeter-sized C_(60) molecular crystal withα-Li_(3)N at 500°C and ambient pres�sure.Characterizations show that the C_(60) cages in the crystal have been efficiently connected,forming 1D chains along the<110>direction in an orthorhombic 3D structure.At the same time,the crystal maintains a morphology similar to that of the pristine C_(60)crystal,providing opportunities for characterization of all the facets of the crystal via Raman spectroscopy and thus suggesting the formation mechanism of such crystals.
文摘BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent studies suggest that MOSE by the endoscopist may be an excellent alternative to rapid on-site evaluation,and some classi-fications have been published.Few studies have assessed the adequacy of histologic cores in MOSE during endoscopic ultrasound-guided fine-needle aspiration/biopsy(EUS-FNA/FNB).AIM To evaluate the performance of MOSE during EUS-FNA/FNB.METHODS This multicentric prospective study was conducted in 16 centers in 3 countries(Egypt,Iraq,and Morocco)and included 1108 patients with pancreatic,biliary,or gastrointestinal pathology who were referred for EUS examination.We prospectively analyzed the MOSE in 1008 patients with available histopathological reports according to 2 classifications to determine the adequacy of the histological core samples.Data management and analysis were performed using a Statistical Package for Social Sciences(SPSS)version 27.RESULTS A total of 1074 solid lesions were biopsied in 1008 patients with available cytopathological reports.Mean age was 59 years,and 509 patients(50.5%)were male.The mean lesion size was 38 mm.The most frequently utilized needles were FNB-Franseen(74.5%)and 22 G(93.4%),with a median of 2 passes.According to 2 classifications,618 non-bloody cores(61.3%)and 964 good samples(95.6%)were adequate for histological evaluation.The overall diagnostic yield of cytopathology was 95.5%.The cytological examination confirmed the diagnosis of malignancy in 861 patients(85.4%),while 45 samples(4.5%)were inconclusive.Post-procedural adverse events occurred in 33 patients(3.3%).Statistical analysis showed a difference between needle types(P=0.035)with a high sensitivity of FNB(97%).The analysis of the relationship between the MOSE-score and the final diagnosis showed a significant difference between the different scores of the MOSE(P<0.001).CONCLUSION MOSE is a simple method that allows endoscopists to increase needle passes to improve sample quality.There is significantly higher FNB sensitivity and cytopathology diagnostic yield with good MOSE cores.
文摘Endoscopic ultrasound (EUS) has become an essential tool for the study of pancreatic diseases. Specifically, EUS plays a pivotal role evaluating patients with a known or suspected pancreatic mass. In this setting, differential diagnosis remains a clinical challenge. EUS-guided fine-needle aspiration (FNA) and fine-needle biopsy (FNB) have been proven to be safe and useful tools in this setting. EUS-guided FNA and FNB, by obtaining cytological and/or histological samples, are able to diagnose pancreatic lesions with high sensitivity and specificity. In this context, several methodological features, trying to increase the diagnostic yield of EUS-guided FNA and FNB, have been evaluated. In this review, we focus on the role of rapid on-site evaluation (ROSE). From data reported in the literature, ROSE may increase diagnostic yield of EUS-FNA specimens by 10%-30%, and thus, diagnostic accuracy. However, we should point out that many recent studies have reported adequacy rates of > 90% without ROSE, indicating that, perhaps, at high-volume centers, ROSE may not be indispensable to achieve excellent results. The use of ROSE can be considered important during the learning curve of EUS-FNA, and also in hospital with diagnostic accuracy rates < 90%.
基金supported by the Science and technology project of State Grid Information&Telecommunication Group Co.,Ltd (SGTYHT/19-JS-218)
文摘A“cloud-edge-end”collaborative system architecture is adopted for real-time security management of power system on-site work,and mobile edge computing equipment utilizes lightweight intelligent recognition algorithms for on-site risk assessment and alert.Owing to its lightweight and fast speed,YOLOv4-Tiny is often deployed on edge computing equipment for real-time video stream detection;however,its accuracy is relatively low.This study proposes an improved YOLOv4-Tiny algorithm based on attention mechanism and optimized training methods,achieving higher accuracy without compromising the speed.Specifically,a convolution block attention module branch is added to the backbone network to enhance the feature extraction capability and an efficient channel attention mechanism is added in the neck network to improve feature utilization.Moreover,three optimized training methods:transfer learning,mosaic data augmentation,and label smoothing are used to improve the training effect of this improved algorithm.Finally,an edge computing equipment experimental platform equipped with an NVIDIA Jetson Xavier NX chip is established and the newly developed algorithm is tested on it.According to the results,the speed of the improved YOLOv4-Tiny algorithm in detecting on-site dress code compliance datasets is 17.25 FPS,and the mean average precision(mAP)is increased from 70.89%to 85.03%.
基金Support was provided by NSFC grants 41831279 and 41772265 to Yan Zhenggrant 2021YFA0715900 from the National Key Research and Development Program of China。
文摘Approximately 94 to 220 million people worldwide are at risk of drinking well water containing arsenic > 10 μg/L, the WHO guideline value. To identify non-compliant domestic wells, assess health risks and reduce exposure, accurate and rapid on-site inorganic arsenic screening methods are desirable because all domestic wells worldwide need to be tested.Here, the principles, advantages and limitations of commonly used colorimetry, electrochemistry, and biosensing methods are critically reviewed, with the performance compared with laboratory-based benchmark methods. Most commercial kits are based on the classic Gutzeit reaction. Despite being semi-quantitative, the more recent and more expensive products display improved and acceptable accuracy and shorter testing time (~10 min). Carried out by trained professionals, electrochemical methods are also feasible for on-site analysis, although miniaturization is desirable yet challenging. Biosensing using whole bacterial cells or bio-engineered materials such as aptamers is promising, if incorporated with function specific nanomaterials and biomaterials. Since arsenic is frequently found as arsenite in reducing groundwater and subject to oxidation during sampling, transportation and storage, on-site separation and sample preservation are feasible but the specific methods should be chosen based on sample matrix and tested before use. To eliminate arsenic exposure among hundreds of millions of mostly rural residents worldwide, we call for concerted efforts in research community and regulatory authority to develop accurate, rapid, and affordable tests for on-site screening and monitoring of arsenic in drinking water. Access to affordable testing will benefit people who are socioeconomically disadvantaged.
文摘Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluation(MOSE)performed by an endoscopist was introduced as an alternative to rapid on-site cytologic evaluation to increase the diagnostic yield of EUS-FNB.The MOSE of the biopsy can estimate the adequacy of the sample directly by the macroscopic evaluation of the core tissue obtained from EUS-FNB.Isolated pancreatic tuberculosis is extremely rare and difficult to diagnose because of its non-specific signs and symptoms.Therefore,this challenging diagnosis is based on endoscopy,imaging,and the bacteriological and histological examination of tissue biopsies.This uncommon presentation of tuberculosis can be revealed as pancreatic mass mimicking cancer.EUS-FNB can be very useful in providing a valuable histopathological diagnosis.A calcified lesion with a cheesy core in MOSE must be suggestive of tuberculosis,leading to the request of the GeneXpert,which can detect Mycobacterium tuberculosis deoxyribonucleic acid and resistance to rifampicin.A decent diagnostic strategy is crucial to prevent unnecessary surgical resection and to supply conservative management with antitubercular therapy.
基金supported by the National Key R&D Program of China(Nos.2018YFB1003905)the National Natural Science Foundation of China under Grant No.61971032,Fundamental Research Funds for the Central Universities(No.FRF-TP-18-008A3).
文摘On-site programming big data refers to the massive data generated in the process of software development with the characteristics of real-time,complexity and high-difficulty for processing.Therefore,data cleaning is essential for on-site programming big data.Duplicate data detection is an important step in data cleaning,which can save storage resources and enhance data consistency.Due to the insufficiency in traditional Sorted Neighborhood Method(SNM)and the difficulty of high-dimensional data detection,an optimized algorithm based on random forests with the dynamic and adaptive window size is proposed.The efficiency of the algorithm can be elevated by improving the method of the key-selection,reducing dimension of data set and using an adaptive variable size sliding window.Experimental results show that the improved SNM algorithm exhibits better performance and achieve higher accuracy.
基金supported by the National Natural Science Foundation of China(Grant Nos.11575087 and 11305045)the Fundamental Research Funds for the Central Universities,China(Grant No.2017B17114)
文摘We study the dynamical energy equipartition properties in the integrable Toda model with additional uniform or disordered on-site energies by extensive numerical simulations. The total energy is initially equidistributed among some of the lowest frequency linear modes. For the Toda model with uniform on-site potentials, the energy spectrum keeps its profile nearly unchanged in a relatively short time scale. On a much longer time scale, the energies of tail modes increase slowly with time. Energy equipartition is far away from being attached in our studied time scale. For the Toda model with disordered on-site potentials, the energy transfers continuously to the high frequency modes and eventually towards energy equipartition. We further perform a systematic study of the equipartition time teq depending on the energy density ε and the nonlinear parameter α in the thermodynamic limit for the Toda model with disordered on-site potentials. We find teq∝ (1/ε)^a(1/α)^b, where b≈ 2a. The values of a and b are increased when increasing the strengths of disordered on-site potentials or decreasing the number of initially excited modes.
基金National Science and Technology Major Project of China(No.2016ZX04003001)
文摘Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve of a train,the speed of which is over200km/h.Nevertheless the method has two limitations,one is large field-〇f-view(FO V),the other is calibration time.Hence portable calibration equipment,easy-t〇-build target and rapid calibration algorithm are required to complete the calibration.In this paper,a new rapid on-site calibration method with large FOV based on binocular stereo vision is proposed.To address these issues,a light target has been designed,the rail coordinate system(RCS)is represented by40fixed retroreflective points on the target,and they are utilized to calibrate the parameters of two cameras.In addition,two cameras merely capture a single image of the target simultaneously,and the intrinsic and extrinsic parameters of the cameras can be calculated rapidly.To testify the proposed method,the experiments have been conducted and the results reveal that the accuracy can reach+1mm,which can meet the measurement requirement.
基金sponsored by the Department of Earthquake Monitoring and Prediction,China Earthquake Administration
文摘According to different testing purposes, methods and available environmental conditions, the seismograph testing can be divided into laboratory and on-site testing, respectively. The testing of the seismograph's key parameters and other concerning technical specifications are well described in guide documents(China Earthquake Administration, 2017). This includes seismometer sensitivity, linearity and clip levels based on the shake table test, as well as the seismometer natural period, damping constant based on electrical calibration(Wang Guangfu,1986; Ple?inger A.,1993) and instrumental self-noise collocation estimation(Holcomb L.G., 1989; Sleeman R. et al., 2006). However, with the development of seismic observation technology, many new requirements for the performance evaluation of seismographs have been put forward, and new testing items and methods have emerged.
文摘Approximately 20% of homes nationwide use an on-site treatment system as a form of household wastewater management. However, approximately 10% to 20% of on-site treatment systems malfunction each year, many of which have either failed or exceeded the soil’s long-term acceptance rate (LTAR), causing environmental and human health risks. The objective of this field study was to evaluate the effects of soil condition (e.g., wet and dry) and product architecture type [i.e., chamber, gravel-less-pipe (GLP), polystyrene-aggregate, and pipe-and-aggregate] on in-product solution storage and biomat thickness in a profile-limited soil in northwest Arkansas under increased loading rates and to estimate the LTAR for each product. During Phase I of this study (March 13 to October 4, 2013), effluent loading rates were approximately doubled, while rates were approximately quadrupled during Phase II (October 8, 2013 to May 29, 2014), from the maximum allowable loading rate for each product. The pipe-and-tire-chip, 46-cm-wide trench pipe-and-gravel, and the 25-cm diameter GLP products had the greatest (p < 0.001), while the 31-cm-width and the 5.4-m-long chambers had the lowest (p < 0.001) in-product solution storage during wet-soil conditions of Phase I monitoring. The 25-cm diameter GLP product had the greatest (p < 0.001), while the 61-cm-width, 5.4-m-long chamber had the lowest (p < 0.001) in-product solution storage during Phase II. Results of this study indicate that some alternative products may be able to effectively handle effluent loading rates in excess of those currently allowed by the State of Arkansas. Further research will be required to confirm these interpretations.
文摘The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary γ-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation.
文摘A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to further diagnose and locate the potential problem of the cable system. This paper presents the experience of the present authors carrying out the cable test. Following a brief introduction to the experiment equipments and physical connections, the paper analyses the data collected from the testing, including PD pulse shape analysis, frequency spectrum analysis and phase resolved PD pattern analysis. Associated with PD propagation direction identification, PD source diagnosis and localisation was made. Four different types of sensors, which were adapted during the testing, are shown to have different frequency bandwidths and performed differently. Aider comparing the parameters of the sensor and the PD signals detected by individual sensor, optimal PD monitoring bandwidth for cable system is suggested.