Three-dimensional Computational Fluid Dynamics Modeling of Two-phase Flow in a Structured Packing Column 被引量:4
1
作者 张小斌 姚蕾 +1 位作者 邱利民 张学军 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第9期959-966,共8页
Characterizing the complex two-phase hydrodynamics in structured packed columns requires a power- ful modeling tool. The traditional two-dimensional model exhibits limitations when one attempts to model the de- tailed... Characterizing the complex two-phase hydrodynamics in structured packed columns requires a power- ful modeling tool. The traditional two-dimensional model exhibits limitations when one attempts to model the de- tailed two-phase flow inside the columns. The present paper presents a three-dimensional computational fluid dy- namics (CFD) model to simulate the two-phase flow in a representative unit of the column. The unit consists of an CFD calculations on column packed with Flexipak 1Y were implemented within the volume of fluid (VOF) mathe- matical framework. The CFD model was validated by comparing the calculated thickness of liquid film with the available experimental data. Special attention was given to quantitative analysis of the effects of gravity on the hy- drodynamics. Fluctuations in the liquid mass flow rate and the calculated pressure drop loss were found to be quali- tatively in agreement with the experimental observations. 展开更多
关键词 structured packing column two-phase flow computational fluid dynamics THREE-DIMENSION
在线阅读 下载PDF
Torsionally Coupled Response Control of Offshore Platform Structures Using Circular Tuned Liquid Column Dampers 被引量:2
2
作者 霍林生 李宏男 《海洋工程:英文版》 EI 2004年第2期173-183,共11页
In this paper, the control performance is investigated of Circular Tuned Liquid Column Dampers (CTLCD) over torsional response of offshore platform structures excited by ground motions. Based on the equation of motion... In this paper, the control performance is investigated of Circular Tuned Liquid Column Dampers (CTLCD) over torsional response of offshore platform structures excited by ground motions. Based on the equation of motion for the CTLCD-structure system, the optimal control parameters of CTLCD are given through some derivations on the supposition that the ground motion is a stochastic process. The influence of systematic parameters on the equivalent damping ratio of the structures is analyzed with purely torsional vibration and translational-torsional coupled vibration, respectively. The results show that the Circular Tuned Liquid Column Damper (CTLCD) is an effective torsional response control device. 展开更多
关键词 circular tuned liquid column dampers offshore platform vibration control seismic response eccentric structures
在线阅读 下载PDF
New Factor to Characterize Mechanism of “Strong Column-Weak Beam” of RC Frame Structures 被引量:2
3
作者 李心霞 公茂盛 +1 位作者 韩庆华 谢礼立 《Transactions of Tianjin University》 EI CAS 2015年第6期484-491,共8页
Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To ... Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the "strong column-weak beam" failure mode under the excitation of strong ground motions. The limit values of column-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values. 展开更多
关键词 RC frame structure strong column-weak beam limit value of column-beam relative factor moment magnification factor at column end
在线阅读 下载PDF
Finite Element Analysis of the Influence of End Grouting Defects in Grouted Sleeve on the Structural Performance of Precast Reinforced Concrete Columns
4
作者 Shuoting Xiao Nikita Igorevich Fomin +1 位作者 Kirill Anatolyevich Khvostunkov Chong Liu 《Computer Modeling in Engineering & Sciences》 2025年第12期2821-2847,共27页
Precast concrete structures have gained popularity due to their advantages.However,the seismic performance of their connection joints remains an area of ongoing research and improvement.Grouted Sleeve Connection(GSC)o... Precast concrete structures have gained popularity due to their advantages.However,the seismic performance of their connection joints remains an area of ongoing research and improvement.Grouted Sleeve Connection(GSC)offers a solution for connecting reinforcements in precast components,but their vulnerability to internal defects,such as construction errors and material variability,can significantly impact performance.This article presents a finite element analysis(FEA)to evaluate the impact of internal grouting defects in GSC on the structural performance of precast reinforced concrete columns.Four finite elementmodels representing GSC with varying degrees of defects were used to investigate the effects on mechanical properties,including bearing capacity,stress-deformation behavior,and stiffness degradation.The study highlights the significant impact of internal grouting defects on the mechanical performance of GSC,with findings indicating a decrease in stiffness,increased plastic deformation,and reduced energy dissipation as the proportion of internal defects rises.The analysis reveals that the internal defects in GSC act as stress concentration points,leading to early crack formation and accelerated damage under cyclic loading.By improving construction quality and reducing the prevalence of grouting defects,the adverse effects on the performance of GSC can be mitigated.Compared to defect-free specimens,those with defects of 30%exhibited a 31.23%reduction in horizontal bearing capacity,highlighting the importance of minimizing defects in practical engineering applications. 展开更多
关键词 Precast concrete structures column grouted sleeve connections(GSC) seismic performance internal defects finite element analysis(FEA) mechanical properties
在线阅读 下载PDF
Study of Suitability of Out-of-Codes Tall Slab-Column and Shearwall Structure 被引量:1
5
作者 GUO Nan ZHAO Tingting LIN Yiying 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2012年第6期1014-1022,共9页
The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-colu... The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-column and shearwall structure in the practical engineering,the key parameters of slab-column and shearwall structure and frame-shearwall structure such as deflection,punching shear behavior,story drift and capability curve were worked out by static plastic analysis,elastic-plastic time history analysis and pushover analysis,then the suitability of out-of-codes tall slab-column and shearwall structure was evaluated.The results show that the out-of-codes tall slab-column and shearwall structure studies could satisfy the require of deflection and punching shear behavior,the story drift under 7 degree expected rare earthquake waves could satisfy the limit value in the codes and the seismic design spectrum was crossed by the capability curve of the structure and the structure could not collapse.The conclusion is that slab-column and shearwall structure with reasonable design built in Ⅱ soil site of intensity 7 seismic fortification zone can be designed higher than the limit height in the codes. 展开更多
关键词 slab-column and shearwall structure finite element analysis SUITABILITY out-of-codes
在线阅读 下载PDF
Pressure drop of structured packing in pilot column and comparison to common correlations
6
作者 Emil Madsen Randi Neerup +3 位作者 Arne Gladis Jens K.Jørsboe Nicolas von Solms Philip L.Fosbøl 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第12期281-291,共11页
Packed columns are widely used in the chemical industry such as absorption,stripping,distillation,and extraction in the production of e.g.organic chemicals,and pharmaceuticals.Pressure loss and pressure drop correlati... Packed columns are widely used in the chemical industry such as absorption,stripping,distillation,and extraction in the production of e.g.organic chemicals,and pharmaceuticals.Pressure loss and pressure drop correlations are of special interest when it comes to the hydrodynamic properties of a column.The pressure loss across the column is of interest in the design phase when the size of the blower to drive the gas stream through the column has to be decided.The loading point and flooding point are also influenced by the pressure loss and the area of operation is determined from these points.This work examines four different correlations on pressure drop.The correlations are(i)Ergun’s equation(1952),(ii)an improved version of Ergun’s equation by Stichlmair,Bravo,and Fair(1989),(iii)an equation developed by Billet and Schultes(1999),and(iv)an equation by Rocha,Bravo,and Fair(1993).The complexity of the correlations is increasing in the mentioned order,Ergun’s equation being the simplest one.This study investigates if the more complicated correlations give better predictions to pressure drop in packed columns.This is determined by comparing the correlations to experimental data for pressure drop in a packed column with 8.2 m of structured packing using water as the liquid and atmospheric air as the gas.Seven experiments were carried out for determining the pressure drop in the column with liquid flows varying from 0 to 500 kg·h^(-1).At constant liquid flow,the gas flow was varied from approximately 10 to 70 kg·h^(-1).The pressure drop across the non-wetted column was best described by the correlation by Rocha et al.while the pressure drop for liquid flows from 100 to 500 kg·h^(-1)was,in general,best described by Stichlmair’s equation.For an irrigated column,the highest deviation was a predicted pressure drop 69.6%lower than measured.The best prediction was 0.1%higher than the measured.This study shows,surprisingly,that for a system of water and atmospheric air,complicated correlations on pressure drop determination do not provide better estimates than simple equations. 展开更多
关键词 Pressure drop correlations Packed columns structured packing Fluid dynamics
在线阅读 下载PDF
Research on the structural design and the shock-resistant performance of the steel beam-concrete column frame structure
7
作者 WANG Qiao 《International English Education Research》 2019年第2期56-59,共4页
The steel beam-concrete column(RCS)frame structure is composed of the reinforced concrete columns and the steel beams,which is a composite structure with the superior performances.This kind of the frame structure has ... The steel beam-concrete column(RCS)frame structure is composed of the reinforced concrete columns and the steel beams,which is a composite structure with the superior performances.This kind of the frame structure has been rapidly developed and widely used in the field of the civil engineering because of its high building applicability,the fast construction speed,the low cost of the foundation and the good mechanical properties.Various kinds of the large-span,heavy-load and high-rise buildings emerge in endlessly,and the requirement for the structural performance is becoming higher and higher.The reinforced concrete column-steel beam composite frame structure is a high-performance structural system with the broad development prospects in China because of its good mechanical performance,durability,fire resistance and the building use space. 展开更多
关键词 Steel beam-concrete column FRAME structure CONFIGURATION design shock-resistant PERFORMANCE
在线阅读 下载PDF
Micro-column enhanced boiling structure and its ramification
8
作者 汤勇 陆龙生 +1 位作者 袁冬 苏达士 《Journal of Central South University》 SCIE EI CAS 2008年第S2期222-227,共6页
Enhanced boiling experiments of two different enhanced structures were carried out in a thermosyphon loop evaporator chamber. One was micro-columns array structure (MCAS), which was fabricated on copper plate surface ... Enhanced boiling experiments of two different enhanced structures were carried out in a thermosyphon loop evaporator chamber. One was micro-columns array structure (MCAS), which was fabricated on copper plate surface with interaction high speed wire electrode discharge machining (HS-WEDM). The other was the ramification of MCAS, named micro-column-array and sintered-copper compound structure (MSCS), which was fabricated with sintered method on micro-column array structure. Considering the wall superheat and critical heat flux (CHF), comparisons were made between them. The results show that both MCAS and MSCS can enhance the boiling heat transfer. It is also found that the enhanced boiling heat transfer ability of MSCS is changed obviously while the porosity of the sintered copper layer is changed. 展开更多
关键词 ENHANCED BOILING micro-column structure ENHANCED heat transfer
在线阅读 下载PDF
Research and Application on Machining Accuracy Control Technology and Installation Construction Points of Steel Structure Box Column
9
作者 LIUWei 《外文科技期刊数据库(文摘版)工程技术》 2022年第3期173-178,共6页
Through a series of steel column processing control measures, such as automatic cutting and blanking, U-shaped assembly, BOX assembly, CO2 backing weld, submerged arc automatic welding, the construction accuracy of la... Through a series of steel column processing control measures, such as automatic cutting and blanking, U-shaped assembly, BOX assembly, CO2 backing weld, submerged arc automatic welding, the construction accuracy of large steel box column is improved. Through the construction accuracy control of key process of box column on-site installation, the accurate positioning and installation of steel box column is ensured. The welding deformation problem is well solved through the verification of the solid engineering construction. This experience has a great reference value for steel box column processing and construction accuracy control. 展开更多
关键词 steel structure box column welding distortion installation of steel columns accuracy control
原文传递
Analysis of nonlinear stability and post-buckling for Euler-type beam-column structure
10
作者 朱媛媛 胡育佳 程昌钧 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2011年第6期719-728,共10页
Based on the assumption of finite deformation, the Hamilton variational principle is extended to a nonlinear elastic Euler-type beam-column structure located on a nonlinear elastic foundation. The corresponding three-... Based on the assumption of finite deformation, the Hamilton variational principle is extended to a nonlinear elastic Euler-type beam-column structure located on a nonlinear elastic foundation. The corresponding three-dimensional (3D) mathematical model for analyzing the nonlinear mechanical behaviors of structures is established, in which the effects of the rotation inertia and the nonlinearity of material and geometry are considered. As an application, the nonlinear stability and the post-buckling for a linear elastic beam with the equal cross-section located on an elastic foundation are analyzed. One end of the beam is fully fixed, and the other end is partially fixed and subjected to an axial force. A new numerical technique is proposed to calculate the trivial solution, bifurcation points, and bifurcation solutions by the shooting method and the Newton- Raphson iterative method. The first and second bifurcation points and the corresponding bifurcation solutions are calculated successfully. The effects of the foundation resistances and the inertia moments on the bifurcation points are considered. 展开更多
关键词 beam-column structure Hamilton variational principle nonlinear stability shooting method Newton-Raphson iterative method POST-BUCKLING
在线阅读 下载PDF
Barrier Structure Design for Fattening Pigs in Large-scale Pig House with Fermentation Bed 被引量:1
11
作者 刘波 唐建阳 +2 位作者 蓝江林 史怀 李兆龙 《Agricultural Science & Technology》 CAS 2014年第12期2249-2252,2270,共5页
[Objective] The large-scale single-column fattening pig house with fermen- tation bed could hold 1 500 heads of fattening pigs. Since the number of pigs in piggery is too large, the management is difficult. The behavi... [Objective] The large-scale single-column fattening pig house with fermen- tation bed could hold 1 500 heads of fattening pigs. Since the number of pigs in piggery is too large, the management is difficult. The behavior of feeding, drinking, movement, sleeping, fighting of pigs is difficult to handle. The pigs cannot be man- aged well, resulting in the enhanced weakness of piglets, enhanced illness of weak pigs and missing treatment of ill pigs. The management for the pig populations is not satisfactory, and thus, it is needed to improve timely. [Method] The barriers for the fattening pigs in the large-scale pig house with fermentation bed were designed. The single management for single fattening pig was proposed. The large-scale fat- tening pig house was divided into 8 regions. Among them, 4 regions were located in both sides of the fermentation bed. Their main function was to separate ill, weak, small and bad pigs. In addition, the main column was divided into 4 gradual barri- ers. They were used to separate different-size fattening pigs. In view of manage- ment, the different-type pigs were managed dividedly with the gradual barriers. The equally-sized pigs were concentrated into one column. The ill, weak, small and bad pigs were isolated into barriers. Thus, the dynamic management was adopted. Until the fattening pigs grew up to 75 kg and their health was stable, the barriers among the columns were canceled to mix the pigs again and guarantee the pigs more gymnastic space. [Result] This design would improve the disease resistance of ill pigs, health status of weak pigs and management level of pig populations. This study would also provide a basis for the healthy running of large-scale fattening pig house with fermentation bed. [Conclusion] The pig-raising model with fermentation bed would improve the environment of pig house and the welfare of pigs. In addi- tion, the performance of pigs and quality of pork were also improved. The fermen- tation bed had an obvious advantage in safety and economics, and it had a broad application prospect. 展开更多
关键词 Fermentation bed Fattening pigs' management Gradual columns for raising pigs structure of barriers
在线阅读 下载PDF
Study on semi-active control of mega-sub controlled structure by MR damper subject to random wind loads 被引量:6
12
作者 Qin Xiangjun Zhang Xun'an Sheldon Cherry 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2008年第3期285-294,共10页
The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing ... The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing the control effectiveness in mega-frame buildings. In this paper, a dynamic equation and method to assemble parameter matrixes for a mega-sub controlled structure under random wind loads is presented. Semi-active control using magnetorheological dampers for the MSCS under random wind loads is investigated, and is compared with a corresponding system without dampers. A parametric study of the relative stiffness ratio and relative mass ratio between the mega-frame and the substructures, as well as the additional column stiffness ratio that influences the response control effectiveness of the MSCS, is discussed. The studies reveal, for the first time, that different control mechanisms exist. The results indicate that the proposed structure employing semi-active control can offer an effective control mechanism. Guidelines for selecting parameters are provided based on the analytical study. 展开更多
关键词 mega-sub controlled structure (MSCS) semi-active control magnetorheological damper relative stiffness ratio relative mass ratio additional column stiffness ratio wind load
在线阅读 下载PDF
Comparison of Gas Distribution Properties of Conventional and High Capacity Structured Packings 被引量:2
13
作者 Zarko Olujie 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第5期726-732,共7页
This paper presents the results of an experimental study carried out using large scale equipment to observe the effect of geometry on gas distribution properties of a high capacity corrugated sheet structured packing ... This paper presents the results of an experimental study carried out using large scale equipment to observe the effect of geometry on gas distribution properties of a high capacity corrugated sheet structured packing (Montz-pak B 1-250M) and to compare it with that of its conventional counterpart (Montz-pak B1-250). Although the high capacity packing exhibits a significantly lower overall pressure drop, the gas distribution performance is similar to that of the conventional packing, and in both cases consistently good one. 展开更多
关键词 packed columns structured packing high capacity gas distribution
在线阅读 下载PDF
Optimization of Isolation Structure Under Wind Load Excitation and Experimental Study of the Wind Resistant Bearing 被引量:1
14
作者 吴应雄 黄净 +2 位作者 颜桂云 颜学渊 吕加成 《Journal of Shanghai Jiaotong university(Science)》 EI 2016年第6期719-728,共10页
The method of collaborative work between steel plate anti-wind bearing(AWB) and rubber isolation bearing is proposed to study the vibration reduction effect of isolation structure under stronger wind load,and the func... The method of collaborative work between steel plate anti-wind bearing(AWB) and rubber isolation bearing is proposed to study the vibration reduction effect of isolation structure under stronger wind load,and the function mechanism is explained.Based on a practical project,three kinds of schemes with different isolation layers are put forward,the finite element software ETABS is used for time history analysis,and comparison is made on the seismic response of different isolated structure and aseismic structure.Comparison result shows that the isolation layer with rubber bearing and AWB can work reasonably,but further optimization on the designed parameters is needed.Moreover,the design value of horizontal bearing capacity of lead rubber bearing(LRB) is appropriate to be close to the seismic isolation layer under wind load excitation.Finally,numerical simulation and comparative analysis of shear test of the AWB are conducted.With a very small yield displacement and yield strength over 80% of the set of horizontal bearing capacity,the AWB is validated to satisfy the working conditions which provide the horizontal bearing capacity under normal operating conditions and designed earthquake.The AWB yields and malfunctions,when the maximum displacement is less than the displacement of the isolation layer. 展开更多
关键词 isolation structure column top isolation anti-wind-bearing(AWB) numerical simulation shear test
原文传递
Achievements of Truss Models for Reinforced Concrete Structures 被引量:2
15
作者 P. G. Papadopoulos H. Xenidis +3 位作者 P. Lazaridis A. Diamantopoulos P. Lambrou Y. Arethas 《Open Journal of Civil Engineering》 2012年第3期125-131,共7页
Achievements are presented for truss models of RC structures developed in previous years: 1. Two constitutive models, biaxial and triaxial, are based on regular trusses, with bars obeying nonlinear uniaxial σ-ε laws... Achievements are presented for truss models of RC structures developed in previous years: 1. Two constitutive models, biaxial and triaxial, are based on regular trusses, with bars obeying nonlinear uniaxial σ-ε laws of material under simulation;both models have been compared with test results and show a dependence of Poisson ratio on curvature of σ-ε law. 2. A truss finite element has been used in the nonlinear static and dynamic analysis of plane RC frames;it has been compared with test results and describes, in a simple way, the formation of plastic hinges. 3. Thanks to the very simple geometry of a truss, the equilibrium equations can be easily written and the stiffness matrix can be easily updated, both with respect to the deformed truss, within each step of a static incremental loading or within each time step of a dynamic analysis, so that to take into account geometric nonlinearities. So the confinement of a RC column is interpreted as a structural stability effect of concrete. And a significant role of the transverse reinforcement is revealed, that of preventing, by its close spacing and sufficient amount, the buckling of inner longitudinal concrete struts, which would lead to a global instability of the RC column. 4. The proposed truss model is statically indeterminate, so it exhibits some features, which are not met by the “strut-and-tie” model. 展开更多
关键词 Reinforced CONCRETE structure TRUSS Model CONSTITUTIVE Law Material and Geometric NONLINEARITIES CONCRETE Cracking Reinforcement Yield CONCRETE ULTIMATE Compressive Strength Plastic HINGE RC column Confinement Buckling of Inner CONCRETE Struts Global Instability
在线阅读 下载PDF
PERFORMANCE OF MELLAPAK 350Y CORRUGATED SHEET STRUCTURED PACKING AT ELEVATED PRESSURE 被引量:2
16
作者 陈江波 唐忠利 +4 位作者 王广全 刘春江 袁希钢 K.T.Yu 余国琮 《化工学报》 EI CAS CSCD 北大核心 2004年第2期335-336,共2页
关键词 高压 压力差 HETP Mellapak 350Y型波纹规整填料 分离性能 分离塔 传质过程
在线阅读 下载PDF
Liquefaction evaluation of dam foundation soils considering overlying structure
17
作者 Gang Wang Xing Wei Hanlong Liu 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第2期226-232,共7页
The liquefaction analysis procedure conducted at a dam foundation associated with a layer of liquefiablesand is presented. In this case, the effects of the overlying dam and an embedded diaphragm wall onliquefaction p... The liquefaction analysis procedure conducted at a dam foundation associated with a layer of liquefiablesand is presented. In this case, the effects of the overlying dam and an embedded diaphragm wall onliquefaction potential of foundation soils are considered. The analysis follows the stress-based approachwhich compares the earthquake-induced cyclic stresses with the cyclic resistance of the soil, and thecyclic resistance of the sand under complex stress condition is the key issue. Comprehensive laboratorymonotonic and cyclic triaxial tests are conducted to evaluate the static characteristics, dynamic characteristicsand the cyclic resistance against liquefaction of the foundation soils. The distribution of thefactor of safety considering liquefaction is given. It is found that the zones beneath the dam edges andnear the upstream of the diaphragm wall are more susceptible to liquefaction than in free field, whereasthe zone beneath the center of the dam is less susceptible to liquefaction than in free field. According tothe results, the strategies of ground improvement are proposed to mitigate the liquefaction hazards. 2015 Institute of Rock and Soil Mechanics, Chinese Academy of Sciences. Production and hosting byElsevier B.V. All rights reserved. 展开更多
关键词 LIQUEFACTION Overlying structure DAM Stone columns
在线阅读 下载PDF
The Coupling Effect of Spatial Reticulated Shell Structure with Cables
18
作者 马骏 周岱 符旭晨 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第1期52-56,共5页
The spatial reticulated shell structure with cables (RSC) is a kind of coupling working system, which consists of flexible cables, reticulated shell structure (RS) and tower columns. The dynamic analysis of RSC based ... The spatial reticulated shell structure with cables (RSC) is a kind of coupling working system, which consists of flexible cables, reticulated shell structure (RS) and tower columns. The dynamic analysis of RSC based on the coupling model was carried out. Three kinds of elements such as the spatial bar element, cable element and beam element were introduced to analyze the reticulated shell, cable and tower column respectively. Furthermore, such parameter influences as structural boundary conditions, grid configuration, the span-to-depth ratio and the arrangement of cable system upon structural dynamics were analyzed. The structural vibration modes can be divided into four groups based on some numerical examples. And the frequencies in the same group are very close while the frequencies in different groups are different from each other obviously. It is clear that the sequence of the appearance of the each mode group heavily depends on the comparative stiffness of the tower column system, RS and cables. 展开更多
关键词 reticulated shell structure CABLE tower column coupling effect vibration mode
在线阅读 下载PDF
Structural Analysis Programme Based on the Equivalent Column's Method
19
作者 Hulea Radu Parv Bianca Nicoreac Monica Petrina Tudor 《Journal of Civil Engineering and Architecture》 2012年第2期244-250,共7页
The focus of this article is to accomplish a program using MatLab software, which will determine the global behavior of the structure, the stress, stability and frequency of the tall building with "n" levels. The pr... The focus of this article is to accomplish a program using MatLab software, which will determine the global behavior of the structure, the stress, stability and frequency of the tall building with "n" levels. The program starts with the global analyses based on the equivalent column theory. The central core consists of reinforced concrete shear walls of the elevator's tubes and of the staircase, design to resist the lateral loads. Applying the equivalent column' s theory, the bracing system will be replaced by an equivalent column, considered to be a vertical cantilever fixed at the base and the loads will be applied in the shear center axis. The program using mathematical and physical relations, has as input dates the geometrical and stiffness characteristics of the plan of the building and as output dates the critical load, the fundamental frequency, the maximum stresses and deformations of the structure. 展开更多
关键词 Tall structure equivalent column central core.
在线阅读 下载PDF
Effects of partial structural damage in the dynamic characteristics of an existing RC building
20
作者 Fuat Aras 《Earthquake Engineering and Engineering Vibration》 2025年第3期781-793,共13页
Reinforced concrete buildings may experience partial damage after earthquakes or some human-induced actions.A decision about the future of those buildings requires detailed analyses,while determining the dynamic chara... Reinforced concrete buildings may experience partial damage after earthquakes or some human-induced actions.A decision about the future of those buildings requires detailed analyses,while determining the dynamic characteristics of a real building in its pre-and post-event situations can guide the analysis.Hence,this study was planned to monitor the dynamic response of an existing six-story,reinforced concrete building with regard to structural damage.The modal characteristics of the original building were initially determined by the use of operational modal analysis.Next,three steps of progressive structural damage were applied to the building.The first damage level peeled off the clear cover of a beam and three columns on a corner of the building’s ground floor.whereas the second and third levels completely razed the damaged columns.Operational modal analysis was repeated at each damage stage to extract the frequencies and detailed mode shapes.Moreover,numerical models based on the finite element method were constructed to confirm the obtained experimental findings.The well-agreed experimental and numerical findings revealed the damage sensitivity of the building’s dynamic response.The quantified amount of frequency change favored a retrofit of the partially damaged buildings rather than their replacement. 展开更多
关键词 operational modal analysis dynamic analysis structural damage column loss ambient vibration survey